991 resultados para Length measurement


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The National Obesity Observatory has produced a new report - National Child Measurement Programme: Detailed Analysis of the 2006/07 National Dataset. The report highlights the usefulness of the NCMP for advancing our understanding of underweight, overweight and obesity in children. The report looks at the effects of socio-demographic and other factors on the reported prevalence of childhood obesity. It also identifies areas where improvements can be made, and where further analysis and investigation are required.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

QUESTIONS UNDER STUDY: To investigate if two distinct, commercially available embryo culture media have a different effect on birthweight and length of singleton term infants conceived after IVF-ICSI. METHODS: University hospital based cohort study. Between 1 January 2000 and 31 December 2004, patients conceiving through IVF-ICSI at the University Hospital, Lausanne have been allocated to two distinct embryo culture media. Only term singleton pregnancies were analysed (n = 525). Data analysis was performed according to two commercially available culture media: Vitrolife (n = 352) versus Cook (n = 173). Analysis was performed through linear regression adjusted for confounders. Media were considered equivalent if the 95% confidence interval lay between -150 g/+150 g. RESULTS: Length, gestational age and distribution of birthweight percentiles did not differ between groups (for both genders). Analysis of the whole cohort, adjusted for a subset of confounders, resulted in a statistically not different mean birthweight between the two groups (Vitrolife +37 g vs Cook, 95%CI: -46 g to 119 g) suggesting equivalence. Adjustment for an enlarged number of confounders in a subsample of patients (n = 258) also revealed no relevant mean birthweight difference of +71 g (95%CI: -45 g to 187 g) in favour of Vitrolife; however, lacking power to prove equivalence. CONCLUSIONS: Our data suggest that significant differences in birthweight due to these two distinct, commercially available embryo culture media are unlikely.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To investigate the genetic variation among Mycobacterium tuberculosis isolates in the East Azerbaijan Province of Iran and to evaluate the level of and risk factors for recent transmission of tuberculosis (TB), we performed IS6110-based restriction fragment length polymorphism analysis of strains, isolated from 105 patients during the period of September 2002 to March 2003 in TB centers and university hospitals of the province. Among 105 isolates, 81 different IS6110 patterns were found, of which 70 were observed only once and 11 were shared by two to eight isolates. Ninety-six isolates (91.4%) were found to have more than five copies of IS6110 and together with high patterns polymorphism, shows that IS6110-RFLP typing could be useful for studying the epidemiology of TB in Azerbaijan. The minimum estimated rate of recent transmission was 23%, suggesting that the degree of recent transmission in East Azerbaijan Province is relatively low. Clustering was not associated with age, sex or site of infection of TB but drug-resistant isolates were less likely to be clustered than sensitive isolates (p < 0.05).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The number of sequences generated by genome projects has increased exponentially, but gene characterization has not followed at the same rate. Sequencing and analysis of full-length cDNAs is an important step in gene characterization that has been used nowadays by several research groups. In this work, we have selected Schistosoma mansoni clones for full-length sequencing, using an algorithm that investigates the presence of the initial methionine in the parasite sequence based on the positions of alignment start between two sequences. BLAST searches to produce such alignments have been performed using parasite expressed sequence tags produced by Minas Gerais Genome Network against sequences from the database Eukaryotic Cluster of Orthologous Groups (KOG). This procedure has allowed the selection of clones representing 398 proteins which have not been deposited as S. mansoni complete CDS in any public database. Dedicated sequencing of 96 of such clones with reads from both 5' and 3' ends has been performed. These reads have been assembled using PHRAP, resulting in the production of 33 full-length sequences that represent novel S. mansoni proteins. These results shall contribute to construct a more complete view of the biology of this important parasite.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE: Intravoxel incoherent motion MRI has been proposed as an alternative method to measure brain perfusion. Our aim was to evaluate the utility of intravoxel incoherent motion perfusion parameters (the perfusion fraction, the pseudodiffusion coefficient, and the flow-related parameter) to differentiate high- and low-grade brain gliomas. MATERIALS AND METHODS: The intravoxel incoherent motion perfusion parameters were assessed in 21 brain gliomas (16 high-grade, 5 low-grade). Images were acquired by using a Stejskal-Tanner diffusion pulse sequence, with 16 values of b (0-900 s/mm(2)) in 3 orthogonal directions on 3T systems equipped with 32 multichannel receiver head coils. The intravoxel incoherent motion perfusion parameters were derived by fitting the intravoxel incoherent motion biexponential model. Regions of interest were drawn in regions of maximum intravoxel incoherent motion perfusion fraction and contralateral control regions. Statistical significance was assessed by using the Student t test. In addition, regions of interest were drawn around all whole tumors and were evaluated with the help of histograms. RESULTS: In the regions of maximum perfusion fraction, perfusion fraction was significantly higher in the high-grade group (0.127 ± 0.031) than in the low-grade group (0.084 ± 0.016, P < .001) and in the contralateral control region (0.061 ± 0.011, P < .001). No statistically significant difference was observed for the pseudodiffusion coefficient. The perfusion fraction correlated moderately with dynamic susceptibility contrast relative CBV (r = 0.59). The histograms of the perfusion fraction showed a "heavy-tailed" distribution for high-grade but not low-grade gliomas. CONCLUSIONS: The intravoxel incoherent motion perfusion fraction is helpful for differentiating high- from low-grade brain gliomas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tamoxifen (tam) is a widely used endocrine therapy in the treatment of early and advanced stage breast cancer in women and men. It is a pro-drug having weak affinity with the estrogen receptor and needs to be converted to its main metabolite, endoxifen (endox), to have full anticancer activity. Cytochrome 2D6 (CYP2D6) plays a major role in the metabolism of tamoxifen to endoxifen. It is genetically highly polymorphic and its activity influences profoundly the synthesis of endoxifen and potentially the efficacy of tamoxifen treatment. Genotyping is currently the most widely used approach in studies and also in clinical practice to categorize patients as poor- (PM), intermediate- (IM), extensive- (EM) and ultra rapid-metabolizers (UM). Some clinicians already use genotyping in order to tailor the endocrine therapy of their patients. Owing to the large inter-individual variations in concentrations of the active moitey due to genetic and non-genetic influences renders the predictive value of the test uncertain for an individual patient. A significant number of patients classified as EM or IM by genotyping have indeed relatively low endoxifen levels similar to PMs1. This suggests that genotyping is probably not the opti ma l meth o d f or predi cti ng end oxif en l evels.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The paper describes how to integrate audience measurement and site visibility as the main research approaches in outdoor advertising research in a single concept. Details are portrayed on how GPS is used on a large scale in Switzerland for mobility analysis and audience measurement. Furthermore, the development of a software solution is introduced that allows the integration of all mobility data and poster location information. Finally a model and its results is presented for the calculation of coverage of individual poster campaigns and for the calculation of the number of contacts generated by each billboard.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The blood pressure (BP), heart rate (HR), and humoral effects of single intravenous (i.v.) doses of the angiotensin-converting enzyme (ACE) inhibitor captopril was investigated in five normotensive healthy volunteers. Each subject received at 1-week intervals a bolus dose of either captopril (1, 5, and 25 mg) or its vehicle. The study was conducted in a single-blind fashion, and the order of treatment phases was randomized. The different doses of captopril had no acute effect on BP and HR. They induced a dose-dependent decrease in plasma ACE activity and plasma angiotensin II levels. The angiotensin-(1-8) octapeptide was isolated by solid-phase extraction and high-performance liquid chromatography (HPLC) prior to radioimmunoassay (RIA). All three doses of captopril reduced circulating angiotensin II levels within 15 min of drug administration. Only with the 25-mg dose was the angiotensin II concentration below the detection limit at 15 min and still significantly reduced 90 min after drug administration. Simultaneous and progressive decreases in plasma aldosterone levels were observed both with ACE inhibition and during vehicle injection, but the relative fall was more pronounced after captopril administration. No adverse reaction was noticed. These results demonstrate that captopril given parenterally blocks the renin-angiotensin system in a dose-dependent manner. Only with the dose of 25 mg was the inhibition of plasma-converting enzyme activity and the reduction of plasma angiotensin II sustained for at least 1 1/2 h.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aims  To investigate whether the predominant finding of generalized positive associations between self-rated motives for drinking alcohol and negative consequences of drinking alcohol are influenced by (i) using raw scores of motives that may weight inter-individual response behaviours too strongly, and (ii) predictor-criterion contamination by using consequence items where respondents attribute alcohol use as the cause. Design  Cross-sectional study within the European School Survey Project on Alcohol and other Drugs (ESPAD). Setting  School classes. Participants  Students, aged 13-16 (n = 5633). Measurements  Raw, rank and mean-variance standardized scores of the Drinking Motives Questionnaire-Revised (DMQ-R); four consequences: serious problems with friends, sexual intercourse regretted the next day, physical fights and troubles with the police, each itemized with attribution ('because of your alcohol use') and without. Findings  As found previously in the literature, raw scores for all drinking motives had positive associations with negative consequences of drinking, while transformed (rank or Z) scores showed a more specific pattern: external reinforcing motives (social, conformity) had negative and internal reinforcing motives (enhancement, coping) had non-significant or positive associations with negative consequences. Attributed consequences showed stronger associations with motives than non-attributed ones. Conclusion  Standard scoring of the Drinking Motives Questionnaire (Revised) fails to capture motives in a way that permits specific associations with different negative consequences to be identified, whereas use of rank or Z-scores does permit this. Use of attributed consequences overestimates the association with drinking motives.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Several methods have been suggested to estimate non-linear models with interaction terms in the presence of measurement error. Structural equation models eliminate measurement error bias, but require large samples. Ordinary least squares regression on summated scales, regression on factor scores and partial least squares are appropriate for small samples but do not correct measurement error bias. Two stage least squares regression does correct measurement error bias but the results strongly depend on the instrumental variable choice. This article discusses the old disattenuated regression method as an alternative for correcting measurement error in small samples. The method is extended to the case of interaction terms and is illustrated on a model that examines the interaction effect of innovation and style of use of budgets on business performance. Alternative reliability estimates that can be used to disattenuate the estimates are discussed. A comparison is made with the alternative methods. Methods that do not correct for measurement error bias perform very similarly and considerably worse than disattenuated regression

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of our study was to provide an innovative headspace-gas chromatography-mass spectrometry (HS-GC-MS) method applicable for the routine determination of blood CO concentration in forensic toxicology laboratories. The main drawback of the GC/MS methods discussed in literature for CO measurement is the absence of a specific CO internal standard necessary for performing quantification. Even if stable isotope of CO is commercially available in the gaseous state, it is essential to develop a safer method to limit the manipulation of gaseous CO and to precisely control the injected amount of CO for spiking and calibration. To avoid the manipulation of a stable isotope-labeled gas, we have chosen to generate in a vial in situ, an internal labeled standard gas ((13)CO) formed by the reaction of labeled formic acid formic acid (H(13)COOH) with sulfuric acid. As sulfuric acid can also be employed to liberate the CO reagent from whole blood, the procedure allows for the liberation of CO simultaneously with the generation of (13)CO. This method allows for precise measurement of blood CO concentrations from a small amount of blood (10 μL). Finally, this method was applied to measure the CO concentration of intoxicated human blood samples from autopsies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the accounting literature, interaction or moderating effects are usually assessed by means of OLS regression and summated rating scales are constructed to reduce measurement error bias. Structural equation models and two-stage least squares regression could be used to completely eliminate this bias, but large samples are needed. Partial Least Squares are appropriate for small samples but do not correct measurement error bias. In this article, disattenuated regression is discussed as a small sample alternative and is illustrated on data of Bisbe and Otley (in press) that examine the interaction effect of innovation and style of use of budgets on performance. Sizeable differences emerge between OLS and disattenuated regression

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction : Le monitoring de la tension artérielle à domicile est recommandé par plusieurs guidelines et a été montré être faisable chez la personne âgée. Les manomètres au poignet ont récemment été proposés pour la mesure de la tension artérielle à domicile, mais leur précision n'a pas été au préalable évaluée chez les patients âgés. Méthode : Quarante-huit participants (33 femmes et 15 hommes, moyenne d'âge 81.3±8.0 ans) ont leur tension artérielle mesurée avec un appareil au poignet avec capteur de position et un appareil au bras dans un ordre aléatoire et dans une position assise. Résultats : Les moyennes de mesures de tension artérielle étaient systématiquement plus basses avec l'appareil au poignet par rapport à celui du bras pour la pression systolique (120.1±2.2 vs. 130.5±2.2 mmHg, P < 0.001, moyenneidéviation standard) et pour la pression diastolique (66.011.3 vs. 69.7±1.3 mmHg, P < 0.001). De plus, une différence de lOmmHg ou plus grande entre l'appareil au bras et au poignet était observée dans 54.2 et 18,8% des mesures systoliques et diastoliques respectivement. Conclusion : Comparé à l'appareil au bras, l'appareil au poignet avec capteur de position sous-estimait systématiquement aussi bien la tension artérielle systolique que diastolique. L'ampleur de la différence est cliniquement significative et met en doute l'utilisation de l'appareil au poignet pour monitorer la tension artérielle chez la personne âgée. Cette étude indique le besoin de valider les appareils de mesures de la tension artérielle dans tous les groupes d'âge, y compris les personnes âgées.