998 resultados para LOW-DIMENSION
Resumo:
Background Formalised predialysis care has been shown to extend the wellness of individuals with advanced chronic kidney disease, slow disease progression and increase the uptake of home dialysis. Predialysis care, incorporating multidisciplinary input is also vital in delaying the onset of end-stage kidney disease and reducing hospital admissions; thereby decreasing financial demands on health budgets. Predialysis care should include comprehensive information provision and predialysis education. This empowers patients to choose self-care strategies and therapies.
Resumo:
This thesis presents the development of a rapid, sensitive and reproducible spectroscopic method for the detection of TNT in forensic and environmental applications. Simple nano sensors prepared by cost effective methods were utilized as sensitive platforms for the detection of TNT by surface enhanced Raman spectroscopy. The optimization of the substrate and the careful selection of a suitable recognition molecule contributed to the significant improvements of sensitive and selective targeting over current detection methods. The work presented in this thesis paves the way for effective detection and monitoring of explosives residues in law enforcement and environmental health applications.
Resumo:
INTRODUCTION Although the high heritability of BMD variation has long been established, few genes have been conclusively shown to affect the variation of BMD in the general population. Extreme truncate selection has been proposed as a more powerful alternative to unselected cohort designs in quantitative trait association studies. We sought to test these theoretical predictions in studies of the bone densitometry measures BMD, BMC, and femoral neck area, by investigating their association with members of the Wnt pathway, some of which have previously been shown to be associated with BMD in much larger cohorts, in a moderate-sized extreme truncate selected cohort (absolute value BMD Z-scores = 1.5-4.0; n = 344). MATERIALS AND METHODS Ninety-six tag-single nucleotide polymorphism (SNPs) lying in 13 Wnt signaling pathway genes were selected to tag common genetic variation (minor allele frequency [MAF] > 5% with an r(2) > 0.8) within 5 kb of all exons of 13 Wnt signaling pathway genes. The genes studied included LRP1, LRP5, LRP6, Wnt3a, Wnt7b, Wnt10b, SFRP1, SFRP2, DKK1, DKK2, FZD7, WISP3, and SOST. Three hundred forty-four cases with either high or low BMD were genotyped by Illumina Goldengate microarray SNP genotyping methods. Association was tested either by Cochrane-Armitage test for dichotomous variables or by linear regression for quantitative traits. RESULTS Strong association was shown with LRP5, polymorphisms of which have previously been shown to influence total hip BMD (minimum p = 0.0006). In addition, polymorphisms of the Wnt antagonist, SFRP1, were significantly associated with BMD and BMC (minimum p = 0.00042). Previously reported associations of LRP1, LRP6, and SOST with BMD were confirmed. Two other Wnt pathway genes, Wnt3a and DKK2, also showed nominal association with BMD. CONCLUSIONS This study shows that polymorphisms of multiple members of the Wnt pathway are associated with BMD variation. Furthermore, this study shows in a practical trial that study designs involving extreme truncate selection and moderate sample sizes can robustly identify genes of relevant effect sizes involved in BMD variation in the general population. This has implications for the design of future genome-wide studies of quantitative bone phenotypes relevant to osteoporosis.
Resumo:
This technical report describes a Light Detection and Ranging (LiDAR) augmented optimal path planning at low level flight methodology for remote sensing and sampling Unmanned Aerial Vehicles (UAV). The UAV is used to perform remote air sampling and data acquisition from a network of sensors on the ground. The data that contains information on the terrain is in the form of a 3D point clouds maps is processed by the algorithms to find an optimal path. The results show that the method and algorithm are able to use the LiDAR data to avoid obstacles when planning a path from a start to a target point. The report compares the performance of the method as the resolution of the LIDAR map is increased and when a Digital Elevation Model (DEM) is included. From a practical point of view, the optimal path plan is loaded and works seemingly with the UAV ground station and also shows the UAV ground station software augmented with more accurate LIDAR data.
Resumo:
Background: The use of large-volume electrolyte balanced solutions as preparation for colonoscopy often results in poor patient compliance and acceptance. The tolerance, safety, and efficacy of high-versus low volume colon-cleansing methods as preparation for colonoscopy in children were compared by randomized operator-blinded trial. Methods: Twenty-nine children ages 3.6-14.6 years had either high-volume nasogastric balanced polyethylene glycol electrolyte lavage (20 ml/kg/h) until the effluent was clear (n = 15), or two oral doses of sodium phosphate solution (22.5-45 ml) separated by oral fluid intake (n = 14). Results: Both preparations were equally effective. The low-volume preparation was better tolerated and caused less discomfort that the high-volume preparation, judging by serial nurse observations. The incidence of abdominal symptoms, diarrhea, sleep disturbance, and vomiting was not significantly different between the two groups. Both groups had a small reduction in mean hematocrit and serum calcium levels. The sodium phosphate preparation caused increases in mean serum sodium concentrations from 140 to 145 mmol/L and serum phosphate concentrations from 1.41 to 2.53 mmol/L. Ten hours after the commencement of the preanesthetic fast, these concentrations had returned to normal. Conclusions: There are advantages in terms of tolerance, discomfort, and case of administration with acceptable colonic cleansing with the use of the less-invasive oral sodium phosphate low-volume colon-cleansing preparation in children. Safe use requires ensuring an adequate oral fluid intake during the preparation time and avoidance of use in patients with renal insufficiency.
Resumo:
We report the electrical conductivity between 2 and 300 K for LaNi1-xFexO3 across the composition-controlled metal-insulator (m-i) transition. Using a method first suggested by Mobius, we identify the critical concentration x(c) to be 0.3 for the m-i transition. The negative temperature coefficient of resistivity observed at low temperatures in the metallic phase follows a temperature dependence characteristic of disorder effects. The semiconducting compositions (x greater than or equal to 0.3) do not show a simple activation energy but exhibit variable-range hopping at high temperatures confirming that the m-i transition in this system is driven by increasing disorder effects.
Resumo:
An explicit near-optimal guidance scheme is developed for a terminal rendezvous of a spacecraft with a passive target in circular orbit around the earth. The thrust angle versus time profile for the continuous-thrust, constant-acceleration maneuver is derived, based on the assumption that the components of inertial acceleration due to relative position and velocity are negligible on account of the close proximity between the two spacecraft. The control law is obtained as a ''bilinear tangent law'' and an analytic solution to the state differential equations is obtained by expanding a portion of the integrand as an infinite series in time. A differential corrector method is proposed, to obtain real-time updates to the guidance parameters at regular time intervals. Simulation of the guidance scheme is carried out using the Clohessy-Wiltshire equations of relative motion as well as the inverse-square two-body equations of motion. Results for typical examples are presented.
Resumo:
Monitoring gas purity is an important aspect of gas recovery stations where air is usually one of the major impurities. Purity monitors of Katherometric type ate commercially available for this purpose. Alternatively, we discuss here a helium gas purity monitor based on acoustic resonance of a cavity at audio frequencies. It measures the purity by monitoring the resonant frequency of a cylindrical cavity filled with the gas under test and excited by conventional telephone transducers fixed at the ends. The use of the latter simplifies the design considerably. The paper discusses the details of the resonant cavity and the electronic circuit along with temperature compensation. The unit has been calibrated with helium gas of known purities. The unit has a response time of the order of 10 minutes and measures the gas purity to an accuracy of 0.02%. The unit has been installed in our helium recovery system and is found to perform satisfactorily.
Resumo:
D.C. electrical conductivity of polyaniline (33%,40%) blended with PMMA was measured from 5K to 300mK. The conductivity behaviour is consistent with fluctuation induced tunneling. Magneto-resistance (MR) was measured between 300K and 2K. From 20K to 2K, a large positive MR was observed. At 2K, for low magnetic fields (<1 Tesla), a deviation from the normal H-2 behaviour was observed.
Resumo:
Although a wide range of periodic surface nets can be grown on low index silicon surfaces, only a few of these have quasi-one dimensional symmetry. If high index silicon surfaces, such as (553) and (557), are used instead, the surface unit cell contains steps. It is possible to fabricate a number of quasi-one dimensional nanoline systems on the terraces and some of these have nested energy bands near the Fermi level. These nano-scale systems may support exotic many-electron states produced by enhanced electron correlations and a reduction in electron screening in one spatial dimension. In this paper, our groups' experimental and theoretical studies of nanolines phases, grown on both low index and vicinal silicon surfaces are reviewed. These studies give us insight into the electronic properties of artificial nanoline structures.
Resumo:
Melancholic depressive patients referred for ECT were randomized to receive either low dose (n = 20) or high dose (n = 20) stimulus applied bifrontotemporally. The two stimulus groups were comparable on the clinical variables. The EEG seizure was recorded on two channels (right and left frontal), digitized, coded and analyzed offline without knowledge of ECT parameters. EEG seizure was of comparable duration in the two stimulus (high dose and low dose) groups. A new composite measure, Strength-Symmetry-Index (SSI), based on strength and symmetry of seizure EEG was computed using fractal geometry. The SSI of the early-seizure was higher in the high dose than in the low dose ECT group. In a stepwise, logistic regression model, this variable contributed to 65% with correct classification of high dose and low dose ECT seizures.
Resumo:
The Taylor coefficients c and d of the EM form factor of the pion are constrained using analyticity, knowledge of the phase of the form factor in the time-like region, 4m(pi)(2) <= t <= t(in) and its value at one space-like point, using as input the (g - 2) of the muon. This is achieved using the technique of Lagrange multipliers, which gives a transparent expression for the corresponding bounds. We present a detailed study of the sensitivity of the bounds to the choice of time-like phase and errors present in the space-like data, taken from recent experiments. We find that our results constrain c stringently. We compare our results with those in the literature and find agreement with the chiral perturbation-theory results for c. We obtain d similar to O(10) GeV-6 when c is set to the chiral perturbation-theory values.
Resumo:
Total strain controlled low cycle fatigue tests on 316L(N) stainless steel have been conducted in air at various strain rates in the temperature range of 773-873 K to identify the operative time-dependent mechanisms and to understand their influence on the cyclic deformation and fracture behaviour of the alloy. The cyclic stress response at all the testing conditions was marked by an initial hardening followed by stress saturation. A negative strain rate stress response is observed under specific testing conditions which is attributed to dynamic strain ageing (DSA). Transmission electron microscopy studies reveal that there is an increase in the dislocation density and enhanced slip planarity in the DSA regime. Fatigue life is found to decrease with a decrease in strain rate. The degradation in fatigue resistance is attributed to the detrimental effects associated with DSA and oxidation. Quantitative measurement of secondary cracks indicate that both transgranular and intergranular cracking are accelerated predominantly under conditions conducive to DSA.
Resumo:
A common theme in many accounts of road safety and road use in low and middle income countries is a widespread lack of compliance with traffic laws and related legislation. A key element of the success of road crash prevention strategies in high income countries has been the achievement of safer road user behaviour through compliance with traffic laws. Deterrence-based approaches such as speed cameras and random breath testing, which rely on drivers making an assessment that they are likely to be caught if they offend, have been very effective in this regard. However, the long term success of (for example) drink driving legislation has been supported by drivers adopting a moral approach to compliance rather than relying solely on the intensity of police operations. For low and middle income countries such morally based compliance is important, since levels of police resourcing are typically much lower than in Western countries. In the absence of morally based compliance, it is arguable that the patterns of behaviours observed in low and middle income countries can be described as "pragmatic driving": compliance only when there is a high chance of being detected and fined, or where a crash might occur. The potential characteristics of pragmatic driving in the macro-, meso- and micro-context of driving and the enforcement approach that could address it are outlined, with reference to the limited existing information available.
Resumo:
At low temperature (below its freezing/melting temperature), liquid water under confinement is known to exhibit anomalous dynamical features. Here we study structure and dynamics of water in the grooves of a long DNA duplex using molecular dynamics simulations with TIP5P potential at low temperature. We find signatures of a dynamical transition in both translational and orientational dynamics of water molecules in both the major and the minor grooves of a DNA duplex. The transition occurs at a slightly higher temperature (TGL ≈ 255 K) than the temperature at which the bulk water is found to undergo a dynamical transition, which for the TIP5P potential is at 247 K. Groove water, however, exhibits markedly different temperature dependence of its properties from the bulk. Entropy calculations reveal that the minor groove water is ordered even at room temperature, and the transition at T ≈ 255 K can be characterized as a strong-to-strong dynamical transition. Confinement of water in the grooves of DNA favors the formation of a low density four-coordinated state (as a consequence of enthalpy−entropy balance) that makes the liquid−liquid transition stronger. The low temperature water is characterized by pronounced tetrahedral order, as manifested in the sharp rise near 109° in the O−O−O angle distribution. We find that the Adams−Gibbs relation between configurational entropy and translational diffusion holds quite well when the two quantities are plotted together in a master plot for different region of aqueous DNA duplex (bulk, major, and minor grooves) at different temperatures. The activation energy for the transfer of water molecules between different regions of DNA is found to be weakly dependent on temperature.