961 resultados para LEACH Mobile Enhanced protocol
Resumo:
OBJECTIVE: To suggest criteria to guide protocol prescription in ramp treadmill testing, according to sex and age, based on velocity, inclination, and max VO2 reached by the population studied. METHODS: Prospective study describing heart rate (HR), time, velocity, inclination, and VO2 estimated at maximum effort of 1840 individuals from 4 to 79 years old, who performed a treadmill test (TT) according to the ramp protocol. A paired Student t test was used to assess the difference between predicted and reached max VO2, calculated according to the formulas of the "American College of Sports Medicine". RESULTS: Submaximal HR was surpassed in 90.1% of the examinations, with a mean time of 10.0±2.0 minute. Initial and peak inclination velocity of the exercise and max VO2 were inversely proportional to age and were greater in male patients. Predicted Max VO2 was significantly lower than that reached in all patients, except for female children and adolescents (age < 20 years old). CONCLUSION: Use of velocity, inclination, and maximum VO2 actually reached, as a criterion in prescribing the ramp protocol may help in the performance of exercise in treadmill testing. The ramp protocol was well accepted in all age groups and sexes with exercise time within the programmed 8 to 12 minutes.
Resumo:
Se propone sintetizar nuevos materiales como bloques de construcción de estructuras en escala nanometrica o micrométrica: nanotubos de carbono funcionalizados; nanopartículas metálicas; hidrogeles inteligentes; carbones mesoporosos. Con ellos se construiran interfaces solido/liquido estructuradas: multicapas autoensambladas, patrones micrométricos con heterogeneidad tridimensional y estructuras jerárquicas. Se estudiara el intercambio de especies móviles en las interfaces usando técnicas electroquímicas, espectroelectroquimicas, ópticas y de microscopia. De esta manera se podran controlar el intercambio en esa interface. En base a este conocimientos se desarrollaran aplicaciones tecnológicas tales como sensores de oligonucletidos, microceldas de combustible, arreglos de microelectrodos y supercapacitores.
Resumo:
Mobile embedded systems, wireless communication, real-time systems, real-time scheduling, communication protocols, cooperation, reliability and fault-tolerance, middleware
Resumo:
Background: The importance of measuring blood pressure before morning micturition and in the afternoon, while working, is yet to be established in relation to the accuracy of home blood pressure monitoring (HBPM). Objective: To compare two HBPM protocols, considering 24-hour ambulatory blood pressure monitoring (wakefulness ABPM) as gold-standard and measurements taken before morning micturition (BM) and in the afternoon (AM), for the best diagnosis of systemic arterial hypertension (SAH), and their association with prognostic markers. Methods: After undergoing 24-hour wakefulness ABPM, 158 participants (84 women) were randomized for 3- or 5-day HBPM. Two variations of the 3-day protocol were considered: with measurements taken before morning micturition and in the afternoon (BM+AM); and with post-morning-micturition and evening measurements (PM+EM). All patients underwent echocardiography (for left ventricular hypertrophy - LVH) and urinary albumin measurement (for microalbuminuria - MAU). Result: Kappa statistic for the diagnosis of SAH between wakefulness-ABPM and standard 3-day HBPM, 3-day HBPM (BM+AM) and (PM+EM), and 5-day HBPM were 0.660, 0.638, 0.348 and 0.387, respectively. The values of sensitivity of (BM+AM) versus (PM+EM) were 82.6% × 71%, respectively, and of specificity, 84.8% × 74%, respectively. The positive and negative predictive values were 69.1% × 40% and 92.2% × 91.2%, respectively. The comparisons of intraclass correlations for the diagnosis of LVH and MAU between (BM+AM) and (PM+EM) were 0.782 × 0.474 and 0.511 × 0.276, respectively. Conclusions: The 3 day-HBPM protocol including measurements taken before morning micturition and during work in the afternoon showed the best agreement with SAH diagnosis and the best association with prognostic markers.
Resumo:
Background: Despite the availability of guidelines for treatment of heart failure (HF), only a few studies have assessed how hospitals adhere to the recommended therapies. Objectives: Compare the rates of adherence to the prescription of angiotensin-converting enzyme inhibitor or angiotensin II receptor blockers (ACEI/ARB) at hospital discharge, which is considered a quality indicator by the Joint Commission International, and to the prescription of beta-blockers at hospital discharge, which is recommended by national and international guidelines, in a hospital with a case management program to supervise the implementation of a clinical practice protocol (HCP) and another hospital that follows treatment guidelines (HCG). Methods: Prospective observational study that evaluated patients consecutively admitted to both hospitals due to decompensated HF between August 1st, 2006, and December 31st, 2008. We used as comparing parameters the prescription rates of beta-blockers and ACEI/ARB at hospital discharge and in-hospital mortality. Results: We analyzed 1,052 patients (30% female, mean age 70.6 ± 14.1 years), 381 (36%) of whom were seen at HCG and 781 (64%) at HCP. The prescription rates of beta-blockers at discharge at HCG and HCP were both 69% (p = 0.458), whereas those of ACEI/ARB were 83% and 86%, respectively (p = 0.162). In-hospital mortality rates were 16.5% at HCP and 27.8% at HCG (p < 0.001). Conclusion: There was no difference in prescription rates of beta-blocker and ACEI/ARB at hospital discharge between the institutions, but HCP had lower in-hospital mortality. This difference in mortality may be attributed to different clinical characteristics of the patients in both hospitals.
Resumo:
Magdeburg, Univ., Fak. für Verfahrens- und Systemtechnik, Diss., 2010
Resumo:
Today, usability testing in the development of software and systems is essential. A stationary usability lab offers many different possibilities in the evaluation of usability, but it reaches its limits in terms of flexibility and the experimental conditions. Mobile usability studies consider consciously outside influences, and these studies require a specially adapted approach to preparation, implementation and evaluation. Using the example of a mobile eye tracking study the difficulties and the opportunities of mobile testing are considered.
Resumo:
Magdeburg, Univ., Fak. für Maschinenbau, Diss., 2014
Resumo:
Magdeburg, Univ., Fak. für Inf., Diss., 2014
Resumo:
Estudi realitzat a partir d’una estada al laboratori LSR (Logiciels, Systèmes, Réseaux) – IMAG a Grenoble, França, entre els mesos de setembre del 2005 i febrer del 2006. El grup de recerca Drakkar d’aquest laboratori va desenvolupar un nou mecanisme d’accés al medi per a xarxes d’àrea local sense fils (WLAN) anomenat Idle Sense. S’ha avaluat aquest mecanisme en entorns cel·lulars i s’ha comparat del seu comportament amb l’estàndard IEEE 802.11 DCF mitjançant la implementació en un simulador. En els entorns cel·lulars es troben condicions de transmissió molt allunyades de les ideals, i de les analitzades fins al moment, que consisteixen en escenaris formats per una única cel·la aïllada. Per aquest motiu, primer s’ha estudiat els mecanismes d’accés al medi d’Idle Sense en una cel·la i en condicions de transmissió adverses. Després, s’ha estudiat en entorns multicel·lulars, on les comunicacions entre estacions es veuen influenciades pel problema de solapament de cel·les i per les interferències provocades per les transmissions d’estacions d’altres cel·les. També s’ha comparat els resultats obtinguts amb el comportament d’IEEE 802.11 DCF i d’altres propostes de millora: Asymptotically Optimal Backoff (AOB) i Slow Decrease. Finalment, s’ha realitzat una modificació sobre Idle Sense, que s’ha anomenat Weighted Idle Sense, que resulta més adecuat per a treballar en xarxes d’àrea local sense fils en mode infraestructura.
Resumo:
En el perímetre del parc es troben gran nombre d’edificacions amb mancances de subministrament elèctric per la gran dispersió de la població de la comarca. L’objectiu d’aquest estudi és desenvolupar un protocol per determinar la viabilitat de l’energia fotovoltaica en edificis aïllats i aplicar-la de forma pilot a dos edificis gestionats pels responsables del Parc Natural de l’Alt Pirineu: el Centre de Logística i Manteniment (CLM) i el Refugi del Fornet. Aquests han estat escollits per la seva representativitat com a edificis aïllats de la xarxa elèctrica convencional. S’ha elaborat una metodologia pròpia, el Protocol d’instal·lació d’energia fotovoltaica en edificis aïllats de la xarxa elèctrica. S’ha realitzat una anàlisi de sensibilitats del dimensionat fotovoltaic davant la modificació de diversos paràmetres rellevants. Això ha permès determinar les característiques òptimes de viabilitat per als dos edificis en estudi i el cost de la instal·lació fotovoltaica (17.183€ el CLM i 164.815 € el Refugi del Fornet). Els resultats obtinguts en els dos edificis pilot han mostrat el gran cost relatiu entre l’energia fotovoltaica i l’energia elèctrica produïda a partir de combustibles fòssils.
Resumo:
En aquest projecte s'ha realitzat l'anàlisi, disseny i implementació d'un protocol de migració d'agents software basat en l'enviament del codi dels agents fragmentat en múltiples missatges. Aquest protocol es troba dins d'una arquitectura de migració multi-protocol per a la mobilitat d'agents entre plataformes JADE. Finalment, s'ha realitzat un estudi que compara el rendiment assolit pel protocol i les prestacions que aporta.