956 resultados para Irregular satellites


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Hall thrusters, such as Stationary Plasma Thruster (SPT), have been widely used on board modern satellites placed in geo-synchronows orbits for reasons such as orbit maintenance, repositioning and attitude control. In order to study the performance of the stationary plasma thruster, the thrust produced by it has been measured, using a thrust balance with strain gauge sensors under vacuum conditions, by activating the thruster. This activation of thruster has been carried out by switching ON and switching OFF of the necessary power supplies and control of other feed system such as the propellant flow in a particular sequence. Hitherto, these operations were done manually in the required sequence. This paper reports the attempt made to automate the sequential operation of the power supplies and the necessary control valves of the feed system using Intel 8051 microcontroller. This automation has made thrust measurements easier and more sophisticated.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The diversity in the morphology of the SAT-chromosomes of C. arietinum in different roots are analysed in the context of similar variations observed in the different cells of one of the roots. Intergrades between the two pairs of chromosomes with normal satellites and those with tandem ones were observed in anaphases. The differences in the number as well as the size of the SAT-grains of replicated chromosomes indicate that non-reciprocal translocations between sister chromosomes may be of parts of SAT-grains and not of entire ones.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A partially purified sheep liver enzyme that hydrolyzed dinucleotides at the pyrophosphate bond was obtained by solubilizing the 18,000g sediment with n-butanol and fractionating the solubilized enzyme with acetone. The enzyme activity when measured using FAD as substrate, (FAD → FMN + AMP), was optimal at pH 9.7 and temperatures between 30 °–36 ° and at 60 °. The rate of release of FMN with time occurred with an initial lag of 30 sec, a linear increase for 1 min, and a subsequent irregular rate. In the presence of orthophosphate (Pi; 10 μImage ), FMN was released at an uniformly continuous and enhanced rate. 32Pi was not incorporated into the substrate or products. Sodium arsenate counteracted the effects of Pi. The apparent Km and Vmax were 0.133 mImage and 100 units; and 0.133 mImage and 200 units, in the absence and presence of Pi, respectively. The temperature optimum was 42 ° in the presence of Pi.Negative cooperative interactions observed at low concentrations of FAD were abolished by the addition of Pi. The inhibition by AMP was sigmoid and Pi abolished this sigmoidal response. The enzyme hydrolyzed in addition to FAD, NAD+ and NADP+. Nucleoside triphosphates were potent inhibitors of the enzyme activity. The partial inhibition of the enzyme by o-phenanthroline and by p-hydroxymercuribenzoate could be reversed by Fe2+ ions and by reduced glutathione, respectively.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Based on the Aristotelian criterion referred to as 'abductio', Peirce suggests a method of hypothetical inference, which operates in a different way than the deductive and inductive methods. “Abduction is nothing but guessing” (Peirce, 7.219). This principle is of extreme value for the study of our understanding of mathematical self-similarity in both of its typical presentations: relative or absolute. For the first case, abduction incarnates the quantitative/qualitative relationships of a self-similar object or process; for the second case, abduction makes understandable the statistical treatment of self-similarity, 'guessing' the continuity of geometric features to the infinity through the use of a systematic stereotype (for instance, the assumption that the general shape of the Sierpiński triangle continuates identically into its particular shapes). The metaphor coined by Peirce, of an exact map containig itself the same exact map (a map of itself), is not only the most important precedent of Mandelbrot’s problem of measuring the boundaries of a continuous irregular surface with a logarithmic ruler, but also still being a useful abstraction for the conceptualisation of relative and absolute self-similarity, and its mechanisms of implementation. It is useful, also, for explaining some of the most basic geometric ontologies as mental constructions: in the notion of infinite convergence of points in the corners of a triangle, or the intuition for defining two parallel straight lines as two lines in a plane that 'never' intersect.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We report here results from detailed timing and spectral studies of the high mass X-ray binary pulsar 4U 1538-52 over several binary periods using observations made with the Rossi X-ray Timing Explorer (RXTE) and BeppoSAX satellites. Pulse timing analysis with the 2003 RXTE data over two binary orbits confirms an eccentric orbit of the system. Combining the orbitial parameters determined from this observation with the earlier measurements we did not find any evidence of orbital decay in this X-ray binary. We have carried out orbital phase resolved spectroscopy to measure changes in the spectral parameters with orbital phase, particularly the absorption column density and the iron line flux. The RXTE-PCA spectra in the 3-20 keV energy range were fitted with a power law and a high energy cut-off along with a Gaussian line at similar to 6.4 keV, whereas the BeppoSAX spectra needed only a power law and Gaussian emission line at similar to 6.4keV in the restricted energy range of 0.3-10.0 keV. An absorption along the line of sight was included for both the RXTE and BeppoSAX data. The variation of the free spectral parameters over the binary orbit was investigated and we found that the variation of the column density of absorbing material in the line of sight with orbital phase is in reasonable agreement with a simple model of a spherically symmetric stellar wind from the companion star.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper presents an analysis of solar radiation pressure induced coupled librations of gravity stabilized cylindrical spacecraft with a special reference to geostationary communication satellites. The Lagrangian approach is used to obtain the corresponding equations of motion. The solar induced torques are assumed to be free of librational angles and are represented by their Fourier expansion. The response and periodic solutions are obtained through linear and nonlinear analyses, using the method of harmonic balance in the latter case. The stability conditions are obtained using Routh-Hurwitz criteria. To establish the ranges of validity the analytic response is compared with the numerical solution. Finally, values of the system parameters are suggested to make the satellite behave as desired. Among these is a possible approach to subdue the solar induced roll resonance. It is felt that the approximate analysis presented here should significantly reduce the computational efforts involved in the design and stability analysis of the systems.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This article explains how Nono's Il canto sospeso (1956), for solo voices, choir and orchestra, is structured in a logic of counterbalances for each musical action, overlapping a harmonic or ‘intuitive’ geometry, with a contrasting or ‘anti-intuitive’ plot. Unlike the typical relationships with the golden ratio, found in many musical examples in which it appears ‘naturally’ (see Tatlow 2001), intervals in the prime numbers series here are perceived as ‘counter-rhythm’; as a form of a counterintuitive distribution, or, as Jameson (2003:vii) suggests, as “a very irregular way” of apparent distribution.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A two dimensional correlation experiment for the measurement of short and long range homo- and hetero- nuclear residual dipolar couplings (RDCs) from the broad and featureless proton NMR spectra including C-13 satellites is proposed. The method employs a single natural abundant C-13 spin as a spy nucleus to probe all the coupled protons and permits the determination of RDCs of negligible strengths. The technique has been demonstrated for the study of organic chiral molecules aligned in chiral liquid crystal, where additional challenge is to unravel the overlapped spectrum of enantiomers. The significant advantage of the method is demonstrated in better chiral discrimination using homonuclear RDCs as additional parameters. (C) 2010 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Although the first procedure in a seeing human eye using excimer laser was reported in 1988 (McDonald et al. 1989, O'Connor et al. 2006) just three studies (Kymionis et al. 2007, O'Connor et al. 2006, Rajan et al. 2004) with a follow-up over ten years had been published when this thesis was started. The present thesis aims to investigate 1) the long-term outcomes of excimer laser refractive surgery performed for myopia and/or astigmatism by photorefractive keratectomy (PRK) and laser-in situ- keratomileusis (LASIK), 2) the possible differences in postoperative outcomes and complications when moderate-to-high astigmatism is treated with PRK or LASIK, 3) the presence of irregular astigmatism that depend exclusively on the corneal epithelium, and 4) the role of corneal nerve recovery in corneal wound healing in PRK enhancement. Our results revealed that in long-term the number of eyes that achieved uncorrected visual acuity (UCVA)≤0.0 and ≤0.5 (logMAR) was higher after PRK than after LASIK. Postoperative stability was slightly better after PRK than after LASIK. In LASIK treated eyes the incidence of myopic regression was more pronounced when the intended correction was over >6.0 D and in patients aged <30 years.Yet the intended corrections in our study were higher for LASIK than for PRK eyes. No differences were found in percentages of eyes with best corrected visual acuity (BCVA) or loss of two or more lines of visual acuity between PRK and LASIK in the long-term. The postoperative long-term outcomes of PRK with two different delivery systems broad beam and scanning laser were compared and revealed no differences. Postoperative outcomes of moderate-to-high astigmatism yielded better results in terms of UCVA and less compromise or loss of two more lines of BCVA after LASIK that after PRK.Similar stability for both procedures was revealed. Vector analysis showed that LASIK outcomes tended to be more accurate than PRK outcomes, yet no statistically differences were found. Irregular astigmatism secondary to recurrent corneal erosion due to map-dot-fingerprint was successfully treated with phototherapeutic keratectomy (PTK). Preoperative videokeratographies (VK) showed irregular astigmatism. However, postoperatively, all eyes showed a regular pattern. No correlation was found between pre- and postoperative VK patterns. Postoperative outcomes of late PRK in eyes originally subjected to LASIK showed that all (7/7) eyes achieved UCVA ≤0.5 at last follow-up (range 3 — 11 months), and no eye lost lines of BCVA. Postoperatively all eyes developed and initial mild haze (0.5 — 1) into the first month. Yet, at last follow-up 5/7 eyes showed a haze of 0.5 and this was no longer evident in 2/7 eyes. Based on these results, we demonstrated that the long-term outcomes after PRK and LASIK were safe and efficient, with similar stability for both procedures. The PRK outcomes were similar when treated by broad-beam or scanning slit laser. LASIK was better than PRK to correct moderate-to-high astigmatism, yet both procedures showed a tendency of undercorrection. Irregular astigmatism was proven to be able to depend exclusively from the corneal epithelium. If this kind of astigmatism is present in the cornea and a customized PRK/LASIK correction is done based on wavefront measurements an irregular astigmatism may be produced rather than treated. Corneal sensory nerve recovery should have an important role in the modulation of the corneal wound healing and post-operative anterior stromal scarring. PRK enhancement may be an option in eyes with previous LASIK after a sufficient time interval that in at least 2 years.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The title compound, C18H16N2O, crystallizes in the triclinic space group P1, with four independent molecules in the asymmetric unit wherein two molecules have an irregular -ac, -ac, +ap conformation (ap, antiperiplanar; ac, anticlinal), while the other molecules exhibit a different, +ac, +ac, +ap conformation. The planar (r.m.s. deviation = 0.006 A in each of the four molecules) quinoline ring systems of the four molecules are oriented at dihedral angles of 32.8 (2), 33.4 (2), 31.7 (2) and 32.3 (2)degrees with respect to the benzene rings. Intramolecular N-H...N interactions occur in all four independent molecules. The crystal packing is stabilized by intermolecular N-H...O and C-H...O hydrogen bonds, and are further consolidated by C-H...pi and pi-pi stacking interactions centroid-centroid distances = 3.728 (3), 3.722 (3), 3.758 (3) and 3.705 (3) A].

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Although the peptide Boc-Aibl-Ala2-Leu3- Aib4-Alas Leu'-Aib7-Ala8-Leu9-Aib'0-OMe [with a t-butoxycarbonyl(Boc) blocking group at the amino terminus, a methyl ester (OMe) at the carboxyl terminus, and four a-aminoisobutyric (Aib) residues] has a 3-fold repeat of residues, the helix formed by the peptide backbone is irregular. The carboxyl-terminal half assumes an at-helical form with torsion angles ) and r of approximately -60° and -45°, respectively, whereas the amino-terminal half is distorted by an insertion of a water molecule between the amide nitrogen of Ala5 [N(5)] and the carbonyl oxygen of Ala2 [0(2)]. The water molecule W(1) acts as a bridge by forming hydrogen bonds N(5).W(1) (2.93 A) and W(1)---0(2) (2.86 A). The distortion of the helix exposes the carbonyl oxygens of Aib' and Aib4 to the outside environment, with the consequence that the helix assumes an amphiphilic character despite having all apolar residues. Neighboring helices in the crystal run in antiparallel directions. On one side of a helix there are only hydrophobic contacts with efficient interdigitation of leucine side chains with those from the neighboring helix. On the other side of the helix there are hydrogen bonds between protruding carbonyl oxygens and four water molecules that separate two neighboring helices. Along the helix axis the helices bind head-to-tail with a direct hydrogen bond N(2)-0(9) (3.00 A). Crystals grown from methanol/water solution are in space group P2, with a = 15.778 ± 0.004 A, b = 11.228 ± 0.002 A, c = 18.415 ± 0.003 A, = 102.10 ± 0.02ur and two formula units per cell for C49HON1003 2H2OCH3OH. The overall agreement factorR is 7.5% for 3394 reflections observed with intensities >3a(F), and the resolution is 0.90 A.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Generation of raw materials for dry powder inhalers by different size reduction methods can be expected to influence physical and chemical properties of the powders. This can cause differences in particle size, size distribution, shape, crystalline properties, surface texture and energy. These physical properties of powders influence the behaviour of particles before and after inhalation. Materials with an amorphous surface have different surface energy compared to materials with crystalline surface. This can affect the adhesion and cohesion of particles. Changes in the surface nature of the drug particles results in a change in product performance. By stabilization of the raw materials the amorphous surfaces are converted into crystalline surfaces. The primary aim of the study was to investigate the influence of the surface properties of the inhalation particles on the quality of the product. The quality of the inhalation product is evaluated by measuring the fine particle dose (FPD). FDP is the total dose of particles with aerodynamic diameters smaller than 5,0 μm. The secondary aim of this study was to achieve the target level of the FPD and the stability of the FPD. This study was also used to evaluate the importance of the stabilization of the inhalation powders. The study included manufacturing and analysing drug substance 200 μg/dose inhalation powder batches using non-stabilized or stabilized raw materials. The inhaler formulation consisted of micronized drug substance, lactose <100μm and micronized lactose <10μm. The inhaler device was Easyhaler®. Stabilization of the raw materials was done in different relative humidity, temperature and time. Surface properties of the raw materials were studied by dynamic vapour sorption, scanning electron microscopy and three-point nitrogen adsorption technique. Particle size was studied by laser diffraction particle size analyzer. Aerodynamic particle size distribution from inhalers was measured by new generation impactor. Stabilization of all three raw materials was successful. A clear difference between nonstabilized and stabilized raw materials was achieved for drug substance and lactose <10μm. However for lactose <100μm the difference wasn’t as clear as wanted. The surface of the non-stabilized drug substance was more irregular and the particles had more roughness on the surface compared to the stabilized drug substances particles surface. The surface of the stabilized drug particles was more regular and smoother than non-stabilized. Even though a good difference between stabilized and non-stabilized raw materials was achieved, a clear evidence of the effect of the surface properties of the inhalation particles on the quality of the product was not observed. Stabilization of the raw materials didn’t lead to a higher FPD. Possible explanations for the unexpected result might be too rough conditions in the stabilization of the drug substance or smaller than wanted difference in the degree of stabilization of the main component of the product <100μm. Despite positive effects on the quality of the product were not seen there appears to be some evidence that stabilized drug substance results in smaller particle size of dry powder inhalers.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Basepair stacking calculations have been carried out to understand the conformational polymorphism of DNA and its sequence dependence. The recently developed self-consistent parameter set, which is specially suitable for describing irregular DNA structures, has been used to describe the geometry of a basepair doublet. While for basepairs without any propeller, the favourable stacking patterns do not appear to have very strong features, much more noticeable sequence dependent stacking patterns emerge once a propeller is applied to the basepairs. The absolute minima for most sequences occurs for a doublet geometry close to the B-DNA fibre models. Hence in the B-DNA region, no strong sequence dependent features are found, but the range of doublet geometries observed in the crystal structures generally lie within the low energy contours, obtained from stacking energy calculations. The doublet geometry corresponding to the A-DNA fibre model is not energetically favourable for the purine-pyrimidine sequences, which prefer small roll angle values when the slide has a large negative value as in A-DNA. However positive roll with large negative slide is allowed for GG, GA, AG and the pyrimidine-purine steps. This is consistent with the observed geometries of various steps in A-DNA crystals. Thus the general features of the basepair doublets predicted from these theoretical studies agree very well with the results from crystal structure analysis. However, since most sequences show an overall preference for B-type doublet geometry, the B --> A transition for random sequence DNA cannot be explained on the basis of basepair stacking interactions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A method was developed for relative radiometric calibration of single multitemporal Landsat TM image, several multitemporal images covering each others, and several multitemporal images covering different geographic locations. The radiometricly calibrated difference images were used for detecting rapid changes on forest stands. The nonparametric Kernel method was applied for change detection. The accuracy of the change detection was estimated by inspecting the image analysis results in field. The change classification was applied for controlling the quality of the continuously updated forest stand information. The aim was to ensure that all the manmade changes and any forest damages were correctly updated including the attribute and stand delineation information. The image analysis results were compared with the registered treatments and the stand information base. The stands with discrepancies between these two information sources were recommended to be field inspected.