1000 resultados para Invasive mole (IM)
Resumo:
The clinical demand for a device to monitor Blood Pressure (BP) in ambulatory scenarios with minimal use of inflation cuffs is increasing. Based on the so-called Pulse Wave Velocity (PWV) principle, this paper introduces and evaluates a novel concept of BP monitor that can be fully integrated within a chest sensor. After a preliminary calibration, the sensor provides non-occlusive beat-by-beat estimations of Mean Arterial Pressure (MAP) by measuring the Pulse Transit Time (PTT) of arterial pressure pulses travelling from the ascending aorta towards the subcutaneous vasculature of the chest. In a cohort of 15 healthy male subjects, a total of 462 simultaneous readings consisting of reference MAP and chest PTT were acquired. Each subject was recorded at three different days: D, D+3 and D+14. Overall, the implemented protocol induced MAP values to range from 80 ± 6 mmHg in baseline, to 107 ± 9 mmHg during isometric handgrip maneuvers. Agreement between reference and chest-sensor MAP values was tested by using intraclass correlation coefficient (ICC = 0.78) and Bland-Altman analysis (mean error = 0.7 mmHg, standard deviation = 5.1 mmHg). The cumulative percentage of MAP values provided by the chest sensor falling within a range of ±5 mmHg compared to reference MAP readings was of 70%, within ±10 mmHg was of 91%, and within ±15mmHg was of 98%. These results point at the fact that the chest sensor complies with the British Hypertension Society (BHS) requirements of Grade A BP monitors, when applied to MAP readings. Grade A performance was maintained even two weeks after having performed the initial subject-dependent calibration. In conclusion, this paper introduces a sensor and a calibration strategy to perform MAP measurements at the chest. The encouraging performance of the presented technique paves the way towards an ambulatory-compliant, continuous and non-occlusive BP monitoring system.
Resumo:
Introduction: According to guidelines, patients with coronary artery disease (CAD) should undergo revascularization if myocardial ischemia is present. While coronary angiography (CXA) allows the morphological assessment of CAD, the fractional flow reserve (FFR) has proved to be a complementary invasive test to assess the functional significance of CAD, i.e. to detect ischemia. Perfusion Cardiac Magnetic Resonance (CMR) has turned out to be a robust non-invasive technique to assess myocardial ischemia. The objective: is to compare the cost-effectiveness ratio - defined as the costs per patient correctly diagnosed - of two algorithms used to diagnose hemodynamically significant CAD in relation to the pretest likelihood of CAD: 1) aCMRto assess ischemia before referring positive patients to CXA (CMR + CXA), 2) a CXA in all patients combined with a FFR test in patients with angiographically positive stenoses (CXA + FFR). Methods: The costs, evaluated from the health care system perspective in the Swiss, German, the United Kingdom (UK) and the United States (US) contexts, included public prices of the different tests considered as outpatient procedures, complications' costs and costs induced by diagnosis errors (false negative). The effectiveness criterion wasthe ability to accurately identify apatient with significantCAD.Test performancesused in the model were based on the clinical literature. Using a mathematical model, we compared the cost-effectiveness ratio for both algorithms for hypothetical patient cohorts with different pretest likelihood of CAD. Results: The cost-effectiveness ratio decreased hyperbolically with increasing pretest likelihood of CAD for both strategies. CMR + CXA and CXA + FFR were equally costeffective at a pretest likelihood of CAD of 62% in Switzerland, 67% in Germany, 83% in the UK and 84% in the US with costs of CHF 5'794, Euros 1'472, £ 2'685 and $ 2'126 per patient correctly diagnosed. Below these thresholds, CMR + CXA showed lower costs per patient correctly diagnosed than CXA + FFR. Implications for the health care system/professionals/patients/society These results facilitate decision making for the clinical use of new generations of imaging procedures to detect ischemia. They show to what extent the cost-effectiveness to diagnose CAD depends on the prevalence of the disease.
Resumo:
Lung cancer is the most frequent cause of superior vena cava (SVC) syndrome. Malignant SVC syndrome is generally considered a contraindication to curative resection, although palliative bypasses are done for symptoms that do not respond to medical therapy. However, a majority of patients with such advanced disease die of complications caused by the primary tumor rather than distant metastasis. We present the case of one patient with lung cancer invading the mediastinal structures. Combined resection and replacement of the SVC with a segment of Dacron vascular graft was performed. Postoperative survival time was 24 months.
Resumo:
Background: Non-invasive monitoring of respiratory muscle function is an area of increasing research interest, resulting in the appearance of new monitoring devices, one of these being piezoelectric contact sensors. The present study was designed to test whether the use of piezoelectric contact (non-invasive) sensors could be useful in respiratory monitoring, in particular in measuring the timing of diaphragmatic contraction.Methods: Experiments were performed in an animal model: three pentobarbital anesthetized mongrel dogs. The motion of the thoracic cage was acquired by means of a piezoelectric contact sensor placed on the costal wall. This signal is compared with direct measurements of the diaphragmatic muscle length, made by sonomicrometry. Furthermore, to assess the diaphragmatic function other respiratory signals were acquired: respiratory airflow and transdiaphragmatic pressure. Diaphragm contraction time was estimated with these four signals. Using diaphragm length signal as reference, contraction times estimated with the other three signals were compared with the contraction time estimated with diaphragm length signal.Results: The contraction time estimated with the TM signal tends to give a reading 0.06 seconds lower than the measure made with the DL signal (-0.21 and 0.00 for FL and DP signals, respectively), with a standard deviation of 0.05 seconds (0.08 and 0.06 for FL and DP signals, respectively). Correlation coefficients indicated a close link between time contraction estimated with TM signal and contraction time estimated with DL signal (a Pearson correlation coefficient of 0.98, a reliability coefficient of 0.95, a slope of 1.01 and a Spearman's rank-order coefficient of 0.98). In general, correlation coefficients and mean and standard deviation of the difference were better in the inspiratory load respiratory test than in spontaneous ventilation tests.Conclusion: The technique presented in this work provides a non-invasive method to assess the timing of diaphragmatic contraction in canines, using a piezoelectric contact sensor placed on the costal wall.
Resumo:
We describe a simple method to achieve both hemostasis and stabilization of the left anterior descending coronary artery during minimally invasive coronary artery bypass grafting. This technique allows the surgeon to perform a precise anastomosis of the left internal mammary artery to the target vessel on a beating heart.
Resumo:
BACKGROUND: Minimally invasive surgery (MIS) for late-presenting congenital diaphragmatic hernia (CDH) has been described previously, but few neonatal cases of CDH have been reported. This study aimed to report the multicenter experience of these rare cases and to compare the laparoscopic and thoracoscopic approaches. METHODS: Using MIS procedures, 30 patients (16 boys and 14 girls) from nine centers underwent surgery for CDH within the first month of life, 26 before day 5. Only one patient had associated malformations. There were 10 preterm patients (32-36 weeks of gestational age). Their weight at birth ranged from 1,800 to 3,800 g, with three patients weighing less than 2,600 g. Of the 30 patients, 18 were intubated at birth. RESULTS: The MIS procedures were performed in 18 cases by a thoracoscopic approach and in 12 cases by a laparoscopic approach. No severe complication was observed. For 20 patients, reduction of the intrathoracic contents was achieved easily with 15 thoracoscopies and 5 laparoscopies. In six cases, the reduction was difficult, proving to be impossible for the four remaining patients: one treated with thoracoscopy and three with laparoscopy. The reasons for the inability to reduce the thoracic contents were difficulty of liver mobilization (1 left CDH and 2 right CDH) and the presence of a dilated stomach in the thorax. Reductions were easier for cases of wide diaphragmatic defects using thoracoscopy. There were 10 conversions (5 laparoscopies and 5 thoracoscopies). The reported reasons for conversion were inability to reduce (n = 4), need for a patch (n = 5), lack of adequate vision (n = 4), narrow working space (n = 1), associated bowel malrotation (n = 1), and an anesthetic problem (n = 1). Five defects were too large for direct closure and had to be closed with a patch. Four required conversion, with one performed through video-assisted thoracic surgery. The recurrences were detected after two primer thoracoscopic closures, one of which was managed by successful reoperation using thoracoscopy. CONCLUSIONS: In the neonatal period, CDH can be safely closed using MIS procedures. The overall success rate in this study was 67%. The indication for MIS is not related to weeks of gestational age, to weight at birth (if >2,600 g), or to the extent of the immediate neonatal care. Patients with no associated anomaly who are hemodynamically stabilized can benefit from MIS procedures. Reduction of the herniated organs is easier using thoracoscopy. Right CDH, liver lobe herniation, and the need for a patch closure are the most frequent reasons for conversion.
Resumo:
We investigate the interface between trade and invasive species (IS) risk, focusing on the existing tariff escalation in agro-forestry product markets and its implication for IS risk. Tariff escalation in processed agro-forestry products exacerbates the risk of IS by biasing trade flows toward increased trade of primary commodity flows and against processed-product trade. We show that reducing tariff escalation by lowering the tariff on processed goods increases allocative efficiency and reduces the IS externality, a win-win situation. We also identify policy menus for trade reforms involving tariffs on both raw input and processed goods, leading to winwin situations.
Resumo:
This study reports the isolation and polymorphism characterization of four plastid indels and six nuclear microsatellite loci in the invasive plant Heracleum mantegazzianum. These markers were tested in 27 individuals from two distant H. mantegazzianum populations. Plastid indels revealed the presence of five chlorotypes while five nuclear microsatellite loci rendered polymorphism. Applications of these markers include population genetics and phylogeography of H. mantegazzianum. A very good transferability of markers to Heracleum sphondylium was demonstrated.