871 resultados para International Association of Music Libraries, Archives and Domentation Centres


Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES: Leptin may be involved in the regulation of body weight, food intake, and energy expenditure. In view of a possible link between leptin concentrations and diabetes that has been suggested in obese rodents, we investigated the potential relationship between serum leptin concentrations and hyperglycaemia in French patients with morbid obesity. SUBJECTS: Fasting leptin concentrations were measured in 241 morbidly obese patients with various degrees of glucose tolerance in a cross-sectional study. RESULTS: Fasting serum leptin concentrations did not differ between normoglycaemia (NG, 61.5 +/- 24.0 ng/ml) and glucose intolerant morbidly obese subjects (IGT, 56.5 +/- 18.5 ng/ml) and were slightly lower in those with controlled diabetes (55.1 +/- 30.3 ng/ml, P = 0.06 when compared to NG subjects). In contrast, leptin concentrations were 30% lower in patients with poorly controlled diabetes (43.0 +/- 22.2 ng/ml, P = 0.001 vs NG subjects). Leptin concentrations were negatively correlated with fasting glucose in all groups combined (p = -0.24, P = 0.0001) and particularly in NIDDM subjects (p = 0.31, P = 0.0054). Although leptin concentrations were higher in women than in men, similar significant correlation with fasting glucose was found when females were analyzed separately. A positive correlation was found with BMI (p = 0.25, P = 0.0001) in all groups. Multivariate analysis revealed that fasting glucose was independently associated with serum leptin concentrations (F = 12.5, P = 0.0005). Sex, age, BMI, waist/hip ratio, fasting glucose and insulin, total cholesterol and triglycerides, tested in the model, explained 42% of the leptin variability in this population. CONCLUSIONS: Poorly controlled diabetes was accompanied by a significant reduction of serum leptin concentrations in morbidly obese subjects. We suggest that a relative leptin deficiency (lower than expected for the BMI) associated with insulin deficiency in this population might contribute to a vicious cycle maintaining (or even worsening) obesity itself and/or its metabolic complications.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Elevated urinary calcium excretion is associated with reduced bone mineral density. Population-based data on urinary calcium excretion are scarce. We explored the association of serum calcium and circulating levels of vitamin D (including 25(OH)D2 and 25(OH)D3) with urinary calcium excretion in men and women in a population-based study. Methods: We used data from the "Swiss Survey on Salt" conducted between 2010 and 2012 and including people aged 15 years and over. Twenty-four hour urine collection, blood analysis, clinical examination and anthropometric measures were collected in 11 centres from the 3 linguistic regions of Switzerland. Vitamin D was measured centrally using liquid chromatography - tandem mass spectrometry. Hypercalciuria was defined as urinary calcium excretion >0.1 mmol/kg/24h. Multivariable linear regression was used to explore factors associated with 24-hour urinary calcium excretion (mmol/24h) squared root transformed, taken as the dependant variable. Vitamin D was divided into monthspecific tertiles with the first tertile having the lowest value and the third tertile having the highest value. Results: The 669 men and 624 women had mean (SD) age of 49.2 (18.1) and 47 (17.9) years and a prevalence of hypercalciuria of 8.9% and 8.0%, respectively. In adjusted models, the association of urinary calcium excretion with protein-corrected serum calcium was (β coefficient } standard error, according to urinary calcium squared root transformed) 1.125 } 0.184 mmol/L per square-root (mmol/24h) (P<0.001) in women and 0.374 } 0.224 (P=0.096) in men. Men in the third month-specific vitamin D tertile had higher urinary calcium excretion than men in the first tertile (0.170 } 0.05 nmol/L per mmol/24h, P=0.001) and the corresponding association was 0.048 } 0.043, P= 0.272 in women. Conclusion: About one in eleven person has hypercalciuria in the Swiss population. The positive association of serum calcium with urinary calcium excretion was steeper in women than in men, independently of menopausal status. Circulating vitamin D was associated positively with urinary calcium excretion only in men. The reasons underlying the observed sex differences in the hormonal control of urinary calcium excretion need to be explored in further studies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

INTRODUCTION: To report acute and late toxicities in patients with intermediate- and high-risk prostate cancer treated with combined high-dose-rate brachytherapy (HDR-B) and intensity-modulated radiation therapy (IMRT). MATERIALS AND METHODS: From March 2003 to September 2005, 64 men were treated with a single implant HDR-B with 21 Gy given in three fractions, followed by 50 Gy IMRT along with organ tracking. Median age was 66.1 years, and risk of recurrence was intermediate in 47% of the patients or high in 53% of the patients. Androgen deprivation therapy was received by 69% of the patients. Toxicity was scored according to the CTCAE version 3.0. Median follow-up was 3.1 years. RESULTS: Acute grade 3 genitourinary (GU) toxicity was observed in 7.8% of the patients, and late grades 3 and 4 GU toxicity was observed in 10.9% and 1.6% of the patients. Acute grade 3 gastrointestinal (GI) toxicity was experienced by 1.6% of the patients, and late grade 3 GI toxicity was absent. The urethral V(120) (urethral volume receiving &gt; or =120% of the prescribed HDR-B dose) was associated with acute (P=.047) and late &gt; or = grade 2 GU toxicities (P=.049). CONCLUSIONS: Late grades 3 and 4GU toxicity occurred in 10.9% and 1.6% of the patients after HDR-B followed by IMRT in association with the irradiated urethral volume. The impact of V(120) on GU toxicity should be validated in further studies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: The aim of this review was to systematically evaluate and compare the frequency of veneer chipping and core fracture of zirconia fixed dental prostheses (FOPS) and porcelain-fused-to-metal (PFM) FDPs and determine possible influencing factors. Materials and Methods: The SCOPUS database and International Association of Dental Research abstracts were searched for clinical studies involving zirconia and PFM FDPs. Furthermore, studies that were integrated into systematic reviews on PFM FDPs were also evaluated. The principle investigators of any clinical studies on zirconia FDPs were contacted to provide additional information. Based on the available information for each FOP, a data file was constructed. Veneer chipping was divided into three grades (grade 1 = polishing, grade 2 = repair, grade 3 = replacement). To assess the frequency of veneer chipping and possible influencing factors, a piecewise exponential model was used to adjust for a study effect. Results: None of the studies on PFM FDPs (reviews and additional searching) sufficiently satisfied the criteria of this review to be included. Thirteen clinical studies on zirconia FDPs and two studies that investigated both zirconia and PFM FDPs were identified. These studies involved 664 zirconia and 134 PFM FDPs at baseline. Follow-up data were available for 595 zirconia and 127 PFM FDPs. The mean observation period was approximately 3 years for both groups. The frequency of core fracture was less than 1% in the zirconia group and 0% in the PFM group. When all studies were included, 142 veneer chippings were recorded for zirconia FDPs (24%) and 43 for PFM FDPs (34%). However, the studies differed extensively with regard to veneer chipping of zirconia: 85% of all chippings occurred in 4 studies, and 43% of all chippings included zirconia FDPs. If only studies that evaluated both types of core materials were included, the frequency of chipping was 54% for the zirconia-supported FDPs and 34% for PFM FDPs. When adjusting the survival rate for the study effect, the difference between zirconia and PFM FDPs was statistically significant for all grades of chippings (P = .001), as well as for chipping grade 3 (P = .02). If all grades of veneer chippings were taken into account, the survival of PFM FDPs was 97%, while the survival rate of the zirconia FDPs was 90% after 3 years for a typical study. For both PFM and zirconia FDPs, the frequency of grades 1 and 2 veneer chippings was considerably higher than grade 3. Veneer chipping was significantly less frequent in pressed materials than in hand-layered materials, both for zirconia and PFM FDPs (P = .04). Conclusions: Since the frequency of veneer chipping was significantly higher in the zirconia FDPs than PFM FDPs, and as refined processing procedures have started to yield better results in the laboratory, new clinical studies with these new procedures must confirm whether the frequency of veneer chipping can be reduced to the level of PFM. Int J Prosthodont 2010;23:493-502

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Unless effective preventive strategies are implemented, aging of the population will result in a significant worsening of the heart failure (HF) epidemic. Few data exist on whether baseline electrocardiographic (ECG) abnormalities can refine risk prediction for HF. METHODS: We examined a prospective cohort of 2,915 participants aged 70 to 79 years without preexisting HF, enrolled between April 1997 and June 1998 in the Health, Aging, and Body Composition (Health ABC) study. Minnesota Code was used to define major and minor ECG abnormalities at baseline and at year 4 follow-up. Using Cox models, we assessed (1) the association between ECG abnormalities and incident HF and (2) the incremental value of adding ECG to the Health ABC HF Risk Score using the net reclassification index. RESULTS: At baseline, 380 participants (13.0%) had minor, and 620 (21.3%) had major ECG abnormalities. During a median follow-up of 11.4 years, 485 participants (16.6%) developed incident HF. After adjusting for the Health ABC HF Risk Score variables, the hazard ratio (HR) was 1.27 (95% CI 0.96-1.68) for minor and 1.99 (95% CI 1.61-2.44) for major ECG abnormalities. At year 4, 263 participants developed new and 549 had persistent abnormalities; both were associated with increased subsequent HF risk (HR 1.94, 95% CI 1.38-2.72 for new and HR 2.35, 95% CI 1.82-3.02 for persistent ECG abnormalities). Baseline ECG correctly reclassified 10.5% of patients with HF events, 0.8% of those without HF events, and 1.4% of the overall population. The net reclassification index across the Health ABC HF risk categories was 0.11 (95% CI 0.03-0.19). CONCLUSIONS: Among older adults, baseline and new ECG abnormalities are independently associated with increased risk of HF. The contribution of ECG screening for targeted prevention of HF should be evaluated in clinical trials.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Smoking is a leading global cause of disease and mortality. We established the Oxford-GlaxoSmithKline study (Ox-GSK) to perform a genome-wide meta-analysis of SNP association with smoking-related behavioral traits. Our final data set included 41,150 individuals drawn from 20 disease, population and control cohorts. Our analysis confirmed an effect on smoking quantity at a locus on 15q25 (P = 9.45 x 10(-19)) that includes CHRNA5, CHRNA3 and CHRNB4, three genes encoding neuronal nicotinic acetylcholine receptor subunits. We used data from the 1000 Genomes project to investigate the region using imputation, which allowed for analysis of virtually all common SNPs in the region and offered a fivefold increase in marker density over HapMap2 (ref. 2) as an imputation reference panel. Our fine-mapping approach identified a SNP showing the highest significance, rs55853698, located within the promoter region of CHRNA5. Conditional analysis also identified a secondary locus (rs6495308) in CHRNA3.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Clinical practice guidelines have become an important source of information to support clinicians in the management of individual patients. However, current guideline methods have limitations that include the lack of separating the quality of evidence from the strength of recommendations. The Grading of Recommendations, Assessment, Development and Evaluation (GRADE) working group, an international collaboration of guideline developers, methodologists, and clinicians have developed a system that addresses these shortcomings. Core elements include transparent methodology for grading the quality of evidence, the distinction between quality of the evidence and strength of a recommendation, an explicit balancing of benefits and harms of health care interventions, an explicit recognition of the values and preferences that underlie recommendations. The GRADE system has been piloted in various practice settings to ensure that it captures the complexity involved in evidence assessment and grading recommendations while maintaining simplicity and practicality. Many guideline organizations and medical societies have endorsed the system and adopted it for their guideline processes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Genetic factors play a role in chronic obstructive pulmonary disease (COPD) but are poorly understood. A number of candidate genes have been proposed on the basis of the pathogenesis of COPD. These include the matrix metalloproteinase (MMP) genes which play a role in tissue remodelling and fit in with the protease--antiprotease imbalance theory for the cause of COPD. Previous genetic studies of MMPs in COPD have had inadequate coverage of the genes, and have reported conflicting associations of both single nucleotide polymorphisms (SNPs) and SNP haplotypes, plausibly due to under-powered studies. METHODS: To address these issues we genotyped 26 SNPs, providing comprehensive coverage of reported SNP variation, in MMPs- 1, 9 and 12 from 977 COPD patients and 876 non-diseased smokers of European descent and evaluated their association with disease singly and in haplotype combinations. We used logistic regression to adjust for age, gender, centre and smoking history. RESULTS: Haplotypes of two SNPs in MMP-12 (rs652438 and rs2276109), showed an association with severe/very severe disease, corresponding to GOLD Stages III and IV. CONCLUSIONS: Those with the common A-A haplotype for these two SNPs were at greater risk of developing severe/very severe disease (p = 0.0039) while possession of the minor G variants at either SNP locus had a protective effect (adjusted odds ratio of 0.76; 95% CI 0.61 - 0.94). The A-A haplotype was also associated with significantly lower predicted FEV1 (42.62% versus 44.79%; p = 0.0129). This implicates haplotypes of MMP-12 as modifiers of disease severity.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate the variability of bond strength test results of adhesive systems (AS) and to correlate the results with clinical parameters of clinical studies investigating cervical restorations. MATERIALS AND METHODS: Regarding the clinical studies, the internal database which had previously been used for a meta-analysis on cervical restorations was updated with clinical studies published between 2008 and 2012 by searching the PubMed and SCOPUS databases. PubMed and the International Association for Dental Research abstracts online were searched for laboratory studies on microtensile, macrotensile and macroshear bond strength tests. The inclusion criteria were (1) dentin, (2) testing of at least four adhesive systems, (3) same diameter of composite and (4) 24h of water storage prior to testing. The clinical outcome variables were retention loss, marginal discoloration, detectable margins, and a clinical index comprising the three parameters by weighing them. Linear mixed models which included a random study effect were calculated for both, the laboratory and the clinical studies. The variability was assessed by calculating a ratio of variances, dividing the variance among the estimated bonding effects obtained in the linear mixed models by the sum of all variance components estimated in these models. RESULTS: Thirty-two laboratory studies fulfilled the inclusion criteria comprising 183 experiments. Of those, 86 used the microtensile test evaluating 22 adhesive systems (AS). Twenty-seven used the macrotensile test with 17 AS, and 70 used the macroshear test with 24 AS. For 28 AS the results from clinical studies were available. Microtensile and macrotensile (Spearman rho=0.66, p=0.007) were moderately correlated and also microtensile and macroshear (Spearman rho=0.51, p=0.03) but not macroshear and macrotensile (Spearman rho=0.34, p=0.22). The effect of the adhesive system was significant for microtensile and macroshear (p<0.001) but not for macrotensile. The effect of the adhesive system could explain 36% of the variability of the microtensile test, 27% of the macrotensile and 33% of the macroshear test. For the clinical trials, about 49% of the variability of retained restorations could be explained by the adhesive system. With respect to the correlation between bond strength tests and clinical parameters, only a moderate correlation between micro- and macrotensile test results and marginal discoloration was demonstrated. However, no correlation between these tests and a retention loss or marginal integrity was shown. The correlation improved when more studies were included compared to assessing only one study. SIGNIFICANCE: The high variability of bond strength test results highlights the need to establish individual acceptance levels for a given test institute. The weak correlation of bond-strength test results with clinical parameters leads to the conclusion that one should not rely solely on bond strength tests to predict the clinical performance of an adhesive system but one should conduct other laboratory tests like tests on the marginal adaptation of fillings in extracted teeth and the retention loss of restorations in non-retentive cavities after artificial aging.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The objective of this work was to combine the advantages of the dried blood spot (DBS) sampling process with the highly sensitive and selective negative-ion chemical ionization tandem mass spectrometry (NICI-MS-MS) to analyze for recent antidepressants including fluoxetine, norfluoxetine, reboxetine, and paroxetine from micro whole blood samples (i.e., 10 microL). Before analysis, DBS samples were punched out, and antidepressants were simultaneously extracted and derivatized in a single step by use of pentafluoropropionic acid anhydride and 0.02% triethylamine in butyl chloride for 30 min at 60 degrees C under ultrasonication. Derivatives were then separated on a gas chromatograph coupled with a triple-quadrupole mass spectrometer operating in negative selected reaction monitoring mode for a total run time of 5 min. To establish the validity of the method, trueness, precision, and selectivity were determined on the basis of the guidelines of the "Société Française des Sciences et des Techniques Pharmaceutiques" (SFSTP). The assay was found to be linear in the concentration ranges 1 to 500 ng mL(-1) for fluoxetine and norfluoxetine and 20 to 500 ng mL(-1) for reboxetine and paroxetine. Despite the small sampling volume, the limit of detection was estimated at 20 pg mL(-1) for all the analytes. The stability of DBS was also evaluated at -20 degrees C, 4 degrees C, 25 degrees C, and 40 degrees C for up to 30 days. Furthermore, the method was successfully applied to a pharmacokinetic investigation performed on a healthy volunteer after oral administration of a single 40-mg dose of fluoxetine. Thus, this validated DBS method combines an extractive-derivative single step with a fast and sensitive GC-NICI-MS-MS technique. Using microliter blood samples, this procedure offers a patient-friendly tool in many biomedical fields such as checking treatment adherence, therapeutic drug monitoring, toxicological analyses, or pharmacokinetic studies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Nokia Push To Talk järjestelmä tarjoaa uuden kommunikointimetodin tavallisen puhelun oheen. Yksi tärkeimmistä uuden järjestelmän ominaisuuksista on puhelunmuodostuksen nopeus. Lisäksi järjestelmän tulee olla telekommunikaatiojärjestelmien yleisten periaatteiden mukainen, mahdollisimman stabiili ja skaalautuva, jotta järjestelmä olisi mahdollisimman vikasietoinen ja laajennettavissa. Diplomityön päätavoite on esitellä "C++"-tietokantakirjastojen suunnittelua ja testausta. Aluksi tutkitaan tietokantajärjestelmien problematiikkaa alkaen tietokantajärjestelmän valinnasta ja huomioiden erityisesti nopeuskriteerit. Sitten esitellään kaksi teknistä toteutusta kahta "C++"-tietokantakirjastoa varten ja pohditaan joitakin vaihtoehtoisia toteutustapoja.