996 resultados para Image Contrast


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Methods are presented to map complex fiber architectures in tissues by imaging the 3D spectra of tissue water diffusion with MR. First, theoretical considerations show why and under what conditions diffusion contrast is positive. Using this result, spin displacement spectra that are conventionally phase-encoded can be accurately reconstructed by a Fourier transform of the measured signal's modulus. Second, studies of in vitro and in vivo samples demonstrate correspondence between the orientational maxima of the diffusion spectrum and those of the fiber orientation density at each location. In specimens with complex muscular tissue, such as the tongue, diffusion spectrum images show characteristic local heterogeneities of fiber architectures, including angular dispersion and intersection. Cerebral diffusion spectra acquired in normal human subjects resolve known white matter tracts and tract intersections. Finally, the relation between the presented model-free imaging technique and other available diffusion MRI schemes is discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PROPÒSIT: Estudiar l'efecte de la cirurgia LASIK en la llum dispersa i la sensibilitat al contrast. MÈTODES: Vint-i-vuit pacients van ser tractats amb LASIK. La qualitat visual es va avaluar abans de l'operació i dos mesos després. RESULTATS: La mitjana de llum dispersa i la sensibilitat al contrast abans de l'operació no va canviar en dos mesos després. Només un ull tenia un marcat augment en la llum dispersa. Nou ulls van presentar una lleugera disminució en la sensibilitat al contrast. S'han trobat dues complicacions. CONCLUSIÓ: Després de LASIK la majoria dels pacients (80%) no van tenir complicacions i van mantenir la seva qualitat visual. Uns pocs pacients (16%) van tenir una mica de qualitat visual disminuïda. Molt pocs (4%) van tenir complicacions clíniques amb disminució en la qualitat visual.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Iterative reconstruction (IR) techniques reduce image noise in multidetector computed tomography (MDCT) imaging. They can therefore be used to reduce radiation dose while maintaining diagnostic image quality nearly constant. However, CT manufacturers offer several strength levels of IR to choose from. PURPOSE: To determine the optimal strength level of IR in low-dose MDCT of the cervical spine. MATERIAL AND METHODS: Thirty consecutive patients investigated by low-dose cervical spine MDCT were prospectively studied. Raw data were reconstructed using filtered back-projection and sinogram-affirmed IR (SAFIRE, strength levels 1 to 5) techniques. Image noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were measured at C3-C4 and C6-C7 levels. Two radiologists independently and blindly evaluated various anatomical structures (both dense and soft tissues) using a 4-point scale. They also rated the overall diagnostic image quality using a 10-point scale. RESULTS: As IR strength levels increased, image noise decreased linearly, while SNR and CNR both increased linearly at C3-C4 and C6-C7 levels (P < 0.001). For the intervertebral discs, the content of neural foramina and dural sac, and for the ligaments, subjective image quality scores increased linearly with increasing IR strength level (P ≤ 0.03). Conversely, for the soft tissues and trabecular bone, the scores decreased linearly with increasing IR strength level (P < 0.001). Finally, the overall diagnostic image quality scores increased linearly with increasing IR strength level (P < 0.001). CONCLUSION: The optimal strength level of IR in low-dose cervical spine MDCT depends on the anatomical structure to be analyzed. For the intervertebral discs and the content of neural foramina, high strength levels of IR are recommended.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Atrial fibrillation (AF) is largely regarded to be initiated from left atrial (LA) dilatation, with subsequent dilatation of the right atrium (RA) in those who progress to chronic AF. We hypothesized that in adult patients with right-sided congenital heart disease (CHD) and AF, RA dilatation will predominate with subsequent dilatation of the left atrium, as a mirror image. METHODS: Adult patients with diagnosis of right-sided, ASD or left-sided CHD who had undergone an echocardiographic study and electrocardiographic recording in 2007 were included. RA and LA area were measured from the apical view. AF was diagnosed from a 12-lead electrocardiogram or Holter recording. A multivariate logistic regression model was used to identify predictors of AF and linear regression models were performed to measure relationship between RA and LA area and AF. RESULTS: A total of 291 patients were included in the study. Multivariate analysis showed that age (p=0.0001), RA (p=0.025) and LA area (p=0.0016) were significantly related to AF. In patients with pure left-sided pathologies, there was progressive and predominant LA dilatation that paralleled the development of AF from none to paroxysmal to chronic AF. In patients with pure right-sided pathologies, there was a mirror image of progressive and predominant RA dilatation with the development of AF. CONCLUSION: We observed a mirror image atrial dilatation in patients with right sided disease and AF. This may provide novel mechanistic insight as to the origin of AF in these patients and deserves further studying in the form of targeted electrophysiological studies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE: A right-to-left shunt can be identified by contrast transcranial Doppler ultrasonography (c-TCD) at rest and/or after a Valsalva maneuver (VM) or by arterial blood gas (ABG) measurement. We assessed the influence of controlled strain pressures and durations during VM on the right-to-left passage of microbubbles, on which depends the shunt classification by c-TCD, and correlated it with the right-to-left shunt evaluation by ABG measurements in stroke patients with patent foramen ovale (PFO). METHODS: We evaluated 40 stroke patients with transesophageal echocardiography-documented PFO. The microbubbles were recorded with TCD at rest and after 4 different VM conditions with controlled duration and target strain pressures (duration in seconds and pressure in cm H2O, respectively): V5-20, V10-20, V5-40, and V10-40. The ABG analysis was performed after pure oxygen breathing in 34 patients, and the shunt was calculated as percentage of cardiac output. RESULTS: Among all VM conditions, V5-40 and V10-40 yielded the greatest median number of microbubbles (84 and 95, respectively; P&lt;0.01). A significantly larger number of microbubbles were detected in V5-40 than in V5-20 (P&lt;0.001) and in V10-40 than in V10-20 (P&lt;0.01). ABG was not sensitive enough to detect a shunt in 31 patients. CONCLUSIONS: The increase of VM expiratory pressure magnifies the number of microbubbles irrespective of the strain duration. Because the right-to-left shunt classification in PFO is based on the number of microbubbles, a controlled VM pressure is advised for a reproducible shunt assessment. The ABG measurement is not sensitive enough for shunt assessment in stroke patients with PFO.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To investigate the potential of free-breathing 3D steady-state free precession (SSFP) imaging with radial k-space sampling for coronary MR-angiography (MRA), coronary projection MR-angiography and coronary vessel wall imaging. MATERIALS AND METHODS: A navigator-gated free-breathing T2-prepared 3D SSFP sequence (TR = 6.1 ms, TE = 3.0 ms, flip angle = 120 degrees, field-of-view = 360 mm(2)) with radial k-space sampling (384 radials) was implemented for coronary MRA. For projection coronary MRA, this sequence was combined with a 2D selective aortic spin tagging pulse. Coronary vessel wall imaging was performed using a high-resolution inversion-recovery black-blood 3D radial SSFP sequence (384 radials, TR = 5.3 ms, TE = 2.7 ms, flip angle = 55 degrees, reconstructed resolution 0.35 x 0.35 x 1.2 mm(3)) and a local re-inversion pulse. Six healthy volunteers (two for each sequence) were investigated. Motion artifact level was assessed by two radiologists. Results: In coronary MRA, the coronary lumen was displayed with a high signal and high contrast to the surrounding lumen. Projection coronary MRA demonstrated selective visualization of the coronary lumen while surrounding tissue was almost completely suppressed. In coronary vessel wall imaging, the vessel wall was displayed with a high signal when compared to the blood pool and the surrounding tissue. No visible motion artifacts were seen. Conclusion: 3D radial SSFP imaging enables coronary MRA, coronary projection MRA and coronary vessel wall imaging with a low motion artifact level.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: We are interested in the numerical simulation of the anastomotic region comprised between outflow canula of LVAD and the aorta. Segmenta¬tion, geometry reconstruction and grid generation from patient-specific data remain an issue because of the variable quality of DICOM images, in particular CT-scan (e.g. metallic noise of the device, non-aortic contrast phase). We pro¬pose a general framework to overcome this problem and create suitable grids for numerical simulations.Methods: Preliminary treatment of images is performed by reducing the level window and enhancing the contrast of the greyscale image using contrast-limited adaptive histogram equalization. A gradient anisotropic diffusion filter is applied to reduce the noise. Then, watershed segmentation algorithms and mathematical morphology filters allow reconstructing the patient geometry. This is done using the InsightToolKit library (www.itk.org). Finally the Vascular Model¬ing ToolKit (www.vmtk.org) and gmsh (www.geuz.org/gmsh) are used to create the meshes for the fluid (blood) and structure (arterial wall, outflow canula) and to a priori identify the boundary layers. The method is tested on five different patients with left ventricular assistance and who underwent a CT-scan exam.Results: This method produced good results in four patients. The anastomosis area is recovered and the generated grids are suitable for numerical simulations. In one patient the method failed to produce a good segmentation because of the small dimension of the aortic arch with respect to the image resolution.Conclusions: The described framework allows the use of data that could not be otherwise segmented by standard automatic segmentation tools. In particular the computational grids that have been generated are suitable for simulations that take into account fluid-structure interactions. Finally the presented method features a good reproducibility and fast application.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Evaluation of segmentation methods is a crucial aspect in image processing, especially in the medical imaging field, where small differences between segmented regions in the anatomy can be of paramount importance. Usually, segmentation evaluation is based on a measure that depends on the number of segmented voxels inside and outside of some reference regions that are called gold standards. Although some other measures have been also used, in this work we propose a set of new similarity measures, based on different features, such as the location and intensity values of the misclassified voxels, and the connectivity and the boundaries of the segmented data. Using the multidimensional information provided by these measures, we propose a new evaluation method whose results are visualized applying a Principal Component Analysis of the data, obtaining a simplified graphical method to compare different segmentation results. We have carried out an intensive study using several classic segmentation methods applied to a set of MRI simulated data of the brain with several noise and RF inhomogeneity levels, and also to real data, showing that the new measures proposed here and the results that we have obtained from the multidimensional evaluation, improve the robustness of the evaluation and provides better understanding about the difference between segmentation methods.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mosaics have been commonly used as visual maps for undersea exploration and navigation. The position and orientation of an underwater vehicle can be calculated by integrating the apparent motion of the images which form the mosaic. A feature-based mosaicking method is proposed in this paper. The creation of the mosaic is accomplished in four stages: feature selection and matching, detection of points describing the dominant motion, homography computation and mosaic construction. In this work we demonstrate that the use of color and textures as discriminative properties of the image can improve, to a large extent, the accuracy of the constructed mosaic. The system is able to provide 3D metric information concerning the vehicle motion using the knowledge of the intrinsic parameters of the camera while integrating the measurements of an ultrasonic sensor. The experimental results of real images have been tested on the GARBI underwater vehicle

Relevância:

20.00% 20.00%

Publicador:

Resumo:

MRI tractography is the mapping of neural fiber pathways based on diffusion MRI of tissue diffusion anisotropy. Tractography based on diffusion tensor imaging (DTI) cannot directly image multiple fiber orientations within a single voxel. To address this limitation, diffusion spectrum MRI (DSI) and related methods were developed to image complex distributions of intravoxel fiber orientation. Here we demonstrate that tractography based on DSI has the capacity to image crossing fibers in neural tissue. DSI was performed in formalin-fixed brains of adult macaque and in the brains of healthy human subjects. Fiber tract solutions were constructed by a streamline procedure, following directions of maximum diffusion at every point, and analyzed in an interactive visualization environment (TrackVis). We report that DSI tractography accurately shows the known anatomic fiber crossings in optic chiasm, centrum semiovale, and brainstem; fiber intersections in gray matter, including cerebellar folia and the caudate nucleus; and radial fiber architecture in cerebral cortex. In contrast, none of these examples of fiber crossing and complex structure was identified by DTI analysis of the same data sets. These findings indicate that DSI tractography is able to image crossing fibers in neural tissue, an essential step toward non-invasive imaging of connectional neuroanatomy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract :This article examines the interplay of text and image in The Fairy Tales of Charles Perrault (1977), translated by Angela Carter and illustrated by Martin Ware, as a form of intersemiotic dialogue that sheds new light on Carter's work. It argues that Ware's highly original artwork based on the translation not only calls into question the association of fairy tales with children's literature (which still characterizes Carter's translation), but also captures an essential if heretofore neglected aspect of Carter's creative process, namely the dynamics between translating, illustrating and rewriting classic tales. Several elements from Ware's illustrations are indeed taken up and elaborated on in The Bloody Chamber and Other Stories (1979), the collection of "stories about fairy stories" that made Carter famous. These include visual details and strategies that she transposed to the realm of writing, giving rise to reflections on the relation between visuality and textuality.RésuméCet article considère l'interaction du texte et de l'image dans les contes de Perrault traduits par Angela Carter et illustrés par Martin Ware (The Fairy Tales of Charles Perrault, 1977) comme une forme de dialogue intersémiotique particulièrement productif. Il démontre que les illustrations originales de Ware ne mettent pas seulement en question l'assimilation des contes à la littérature de jeunesse (qui est encore la perspective adoptée par la traductrice dans ce livre), mais permettent aussi de saisir un aspect essentiel bien que jusque là ignoré du procession de création dans l'oeuvre de Carter, à savoir la dynamique qui lie la traduction, l'illustration et la réécriture des contes classiques. Plusieurs éléments des illustrations de Ware sont ainsi repris et élaborés dans The Bloody Chamber and Other Stories (1979), la collection de "stories about fairy stories" qui rendit Carter célèbre. La transposition de détails et de stratégies visuelles dans l'écriture donnent ainsi l'occasion de réflexions sur les rapports entre la visualité et la textualité.