966 resultados para High Resolution Mass Spectrometry
Resumo:
Gliomas are routinely graded according to histopathological criteria established by the World Health Organization. Although this classification can be used to understand some of the variance in the clinical outcome of patients, there is still substantial heterogeneity within and between lesions of the same grade. This study evaluated image-guided tissue samples acquired from a large cohort of patients presenting with either new or recurrent gliomas of grades II-IV using ex vivo proton high-resolution magic angle spinning spectroscopy. The quantification of metabolite levels revealed several discrete profiles associated with primary glioma subtypes, as well as secondary subtypes that had undergone transformation to a higher grade at the time of recurrence. Statistical modeling further demonstrated that these metabolomic profiles could be differentially classified with respect to pathological grading and inter-grade conversions. Importantly, the myo-inositol to total choline index allowed for a separation of recurrent low-grade gliomas on different pathological trajectories, the heightened ratio of phosphocholine to glycerophosphocholine uniformly characterized several forms of glioblastoma multiforme, and the onco-metabolite D-2-hydroxyglutarate was shown to help distinguish secondary from primary grade IV glioma, as well as grade II and III from grade IV glioma. These data provide evidence that metabolite levels are of interest in the assessment of both intra-grade and intra-lesional malignancy. Such information could be used to enhance the diagnostic specificity of in vivo spectroscopy and to aid in the selection of the most appropriate therapy for individual patients.
Resumo:
PURPOSE: To investigate the feasibility of high-resolution selective three-dimensional (3D) magnetic resonance coronary angiography (MRCA) in the evaluation of coronary artery stenoses. MATERIALS AND METHODS: In 12 patients with coronary artery stenoses, MRCA of the coronary artery groups, including the coronary segments with stenoses of 50% or greater based on conventional x-ray coronary angiography (CAG), was performed with double-oblique imaging planes by orienting the 3D slab along the major axis of each right coronary artery-left circumflex artery (RCA-LCX) group and each left main trunk-left anterior descending artery (LMT-LAD) group. Ten RCA-LCX and five LMT-LAD MR angiograms were obtained, and the results were compared with those of conventional x-ray angiography. RESULTS: Among 70 coronary artery segments expected to be covered, a total of 49 (70%) segments were fully demonstrated in diagnostic quality. The identification of segmental location of stenoses showed as high an accuracy as 96%. The retrospective analysis for stenosis of 50% or greater yielded the sensitivity, specificity, and accuracy of 80%, 85%, and 84%, respectively. CONCLUSION: Selective 3D MRCA has the potential for segment-by-segment evaluation of major portions of the right and left coronary arteries with high accuracy.
Resumo:
An active learning method is proposed for the semi-automatic selection of training sets in remote sensing image classification. The method adds iteratively to the current training set the unlabeled pixels for which the prediction of an ensemble of classifiers based on bagged training sets show maximum entropy. This way, the algorithm selects the pixels that are the most uncertain and that will improve the model if added in the training set. The user is asked to label such pixels at each iteration. Experiments using support vector machines (SVM) on an 8 classes QuickBird image show the excellent performances of the methods, that equals accuracies of both a model trained with ten times more pixels and a model whose training set has been built using a state-of-the-art SVM specific active learning method
Resumo:
The treatment of some cancer patients has shifted from traditional, non-specific cytotoxic chemotherapy to chronic treatment with molecular targeted therapies. Imatinib mesylate, a selective inhibitor of tyrosine kinases (TKIs) is the most prominent example of this new era and has opened the way to the development of several additional TKIs, including sunitinib, nilotinib, dasatinib, sorafenib and lapatinib, in the treatment of various hematological malignancies and solid tumors. All these agents are characterized by an important inter-individual pharmacokinetic variability, are at risk for drug interactions, and are not devoid of toxicity. Additionally, they are administered for prolonged periods, anticipating the careful monitoring of their plasma exposure via Therapeutic Drug Monitoring (TDM) to be an important component of patients' follow-up. We have developed a liquid chromatography-tandem mass spectrometry method (LC-MS/MS) requiring 100 microL of plasma for the simultaneous determination of the six major TKIs currently in use. Plasma is purified by protein precipitation and the supernatant is diluted in ammonium formate 20 mM (pH 4.0) 1:2. Reverse-phase chromatographic separation of TKIs is obtained using a gradient elution of 20 mM ammonium formate pH 2.2 and acetonitrile containing 1% formic acid, followed by rinsing and re-equilibration to the initial solvent composition up to 20 min. Analyte quantification, using matrix-matched calibration samples, is performed by electro-spray ionization-triple quadrupole mass spectrometry by selected reaction monitoring detection using the positive mode. The method was validated according to FDA recommendations, including assessment of extraction yield, matrix effects variability (<9.6%), overall process efficiency (87.1-104.2%), as well as TKIs short- and long-term stability in plasma. The method is precise (inter-day CV%: 1.3-9.4%), accurate (-9.2 to +9.9%) and sensitive (lower limits of quantification comprised between 1 and 10 ng/mL). This is the first broad-range LC-MS/MS assay covering the major currently in-use TKIs. It is an improvement over previous methods in terms of convenience (a single extraction procedure for six major TKIs, reducing significantly the analytical time), sensitivity, selectivity and throughput. It may contribute to filling the current knowledge gaps in the pharmacokinetics/pharmacodynamics relationships of the latest TKIs developed after imatinib and better define their therapeutic ranges in different patient populations in order to evaluate whether a systematic TDM-guided dose adjustment of these anticancer drugs could contribute to minimize the risk of major adverse reactions and to increase the probability of efficient, long lasting, therapeutic response.
Resumo:
The increasing number of bomb attacks involving improvised explosive devices, as well as the nature of the explosives, give rise to concern among safety and law enforcement agencies. The substances used in explosive charges are often everyday products diverted from their primary licit applications. Thus, reducing or limiting their accessibility for prevention purposes is difficult. Ammonium nitrate, employed in agriculture as a fertiliser, is used worldwide in small and large homemade bombs. Black powder, dedicated to hunting and shooting sports, is used illegally as a filling in pipe bombs causing extensive damage. If the main developments of instrumental techniques in explosive analysis have been constantly pushing the limits of detection, their actual contribution to the investigation of explosives in terms of source discrimination is limited. Forensic science has seen the emergence of a new technology, isotope ratio mass spectrometry (IRMS), that shows promising results. Its very first application in forensic science dates back to 1979. Liu et al. analysed cannabis plants coming from different countries [Liu et al. 1979]. This preliminary study highlighted its potential to discriminate specimens coming from different sources. Thirty years later, the keen interest in this new technology has given rise to a flourishing number of publications in forensic science. The countless applications of IRMS to a wide range of materials and substances attest to its success and suggest that the technique is ready to be used in forensic science. However, many studies are characterised by a lack of methodology and fundamental data. They have been undertaken in a top-down approach, applying this technique in an exploratory manner on a restricted sampling. This manner of procedure often does not allow the researcher to answer a number of questions, such as: do the specimens come from the same source, what do we mean by source or what is the inherent variability of a substance? The production of positive results has prevailed at the expense of forensic fundamentals. This research focused on the evaluation of the contribution of the information provided by isotopic analysis to the investigation of explosives. More specifically, this evaluation was based on a sampling of black powders and ammonium nitrate fertilisers coming from known sources. Not only has the methodology developed in this work enabled us to highlight crucial elements inherent to the methods themselves, but also to evaluate both the longitudinal and transversal variabilities of the information. First, the study of the variability of the profile over time was undertaken. Secondly, the variability of black powders and ammonium nitrate fertilisers within the same source and between different sources was evaluated. The contribution of this information to the investigation of explosives was then evaluated and discussed. --------------------------------------------------------------------------------------------------- Le nombre croissant d'attentats à la bombe impliquant des engins explosifs artisanaux, ainsi que la nature des charges explosives, constituent une préoccupation majeure pour les autorités d'application de la loi et les organismes de sécurité. Les substances utilisées dans les charges explosives sont souvent des produits du quotidien, détournés de leurs applications licites. Par conséquent, réduire ou limiter l'accessibilité de ces produits dans un but de prévention est difficile. Le nitrate d'ammonium, employé dans l'agriculture comme engrais, est utilisé dans des petits et grands engins explosifs artisanaux. La poudre noire, initialement dédiée à la chasse et au tir sportif, est fréquemment utilisée comme charge explosive dans les pipe bombs, qui causent des dommages importants. Si les développements des techniques d'analyse des explosifs n'ont cessé de repousser les limites de détection, leur contribution réelle à l'investigation des explosifs est limitée en termes de discrimination de sources. Une nouvelle technologie qui donne des résultats prometteurs a fait son apparition en science forensique: la spectrométrie de masse à rapport isotopique (IRMS). Sa première application en science forensique remonte à 1979. Liu et al. ont analysé des plants de cannabis provenant de différents pays [Liu et al. 1979]. Cette étude préliminaire, basée sur quelques analyses, a mis en évidence le potentiel de l'IRMS à discriminer des spécimens provenant de sources différentes. Trente ans plus tard, l'intérêt marqué pour cette nouvelle technologie en science forensique se traduit par un nombre florissant de publications. Les innombrables applications de l'IRMS à une large gamme de matériaux et de substances attestent de son succès et suggèrent que la technique est prête à être utilisée en science forensique. Cependant, de nombreuses études sont caractérisées par un manque de méthodologie et de données fondamentales. Elles ont été menées sans définir les hypothèses de recherche et en appliquant cette technique de façon exploratoire sur un échantillonnage restreint. Cette manière de procéder ne permet souvent pas au chercheur de répondre à un certain nombre de questions, tels que: est-ce que deux spécimens proviennent de la même source, qu'entend-on par source ou encore quelle est l'intravariabilité d'une substance? La production de résultats positifs a prévalu au détriment des fondamentaux de science forensique. Cette recherche s'est attachée à évaluer la contribution réelle de l'information isotopique dans les investigations en matière d'explosifs. Plus particulièrement, cette évaluation s'est basée sur un échantillonnage constitué de poudres noires et d'engrais à base de nitrate d'ammonium provenant de sources connues. La méthodologie développée dans ce travail a permis non seulement de mettre en évidence des éléments cruciaux relatifs à la méthode d'analyse elle-même, mais également d'évaluer la variabilité de l'information isotopique d'un point de vue longitudinal et transversal. Dans un premier temps, l'évolution du profil en fonction du temps a été étudiée. Dans un second temps, la variabilité du profil des poudres noires et des engrais à base de nitrate d'ammonium au sein d'une même source et entre différentes sources a été évaluée. La contribution de cette information dans le cadre des investigations d'explosifs a ensuite été discutée et évaluée.
Resumo:
A sensitive and specific ultra performance liquid chromatography-tandem mass spectrometry method for the simultaneous quantification of nicotine, its metabolites cotinine and trans-3'-hydroxycotinine and varenicline in human plasma was developed and validated. Sample preparation was realized by solid phase extraction of the target compounds and of the internal standards (nicotine-d4, cotinine-d3, trans-3'-hydroxycotinine-d3 and CP-533,633, a structural analog of varenicline) from 0.5mL of plasma, using a mixed-mode cation exchange support. Chromatographic separations were performed on a hydrophilic interaction liquid chromatography column (HILIC BEH 2.1×100mm, 1.7μm). A gradient program was used, with a 10mM ammonium formate buffer pH 3/acetonitrile mobile phase at a flow of 0.4mL/min. The compounds were detected on a triple quadrupole mass spectrometer, operated with an electrospray interface in positive ionization mode and quantification was performed using multiple reaction monitoring. Matrix effects were quantitatively evaluated with success, with coefficients of variation inferior to 8%. The procedure was fully validated according to Food and Drug Administration guidelines and to Société Française des Sciences et Techniques Pharmaceutiques. The concentration range was 2-500ng/mL for nicotine, 1-1000ng/mL for cotinine, 2-1000ng/mL for trans-3'-hydroxycotinine and 1-500ng/mL for varenicline, according to levels usually measured in plasma. Trueness (86.2-113.6%), repeatability (1.9-12.3%) and intermediate precision (4.4-15.9%) were found to be satisfactory, as well as stability in plasma. The procedure was successfully used to quantify nicotine, its metabolites and varenicline in more than 400 plasma samples from participants in a clinical study on smoking cessation.
Resumo:
Consumption of nicotine in the form of smokeless tobacco (snus, snuff, chewing tobacco) or nicotine-containing medication (gum, patch) may benefit sport practice. Indeed, use of snus seems to be a growing trend and investigating nicotine consumption amongst professional athletes is of major interest to sport authorities. Thus, a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the detection and quantification of nicotine and its principal metabolites cotinine, trans-3-hydroxycotinine, nicotine-N'-oxide and cotinine-N-oxide in urine was developed. Sample preparation was performed by liquid-liquid extraction followed by hydrophilic interaction chromatography-tandem mass spectrometry (HILIC-MS/MS) operated in electrospray positive ionization (ESI) mode with selective reaction monitoring (SRM) data acquisition. The method was validated and calibration curves were linear over the selected concentration ranges of 10-10,000 ng/mL for nicotine, cotinine, trans-3-hydroxycotinine and 10-5000 ng/mL for nicotine-N'-oxide and cotinine-N-oxide, with calculated coefficients of determination (R(2)) greater than 0.95. The total extraction efficiency (%) was concentration dependent and ranged between 70.4 and 100.4%. The lower limit of quantification (LLOQ) for all analytes was 10 ng/mL. Repeatability and intermediate precision were ?9.4 and ?9.9%, respectively. In order to measure the prevalence of nicotine exposure during the 2009 Ice Hockey World Championships, 72 samples were collected and analyzed after the minimum of 3 months storage period and complete removal of identification means as required by the 2009 International Standards for Laboratories (ISL). Nicotine and/or metabolites were detected in every urine sample, while concentration measurements indicated an exposure within the last 3 days for eight specimens out of ten. Concentrations of nicotine, cotinine, trans-3-hydroxycotinine, nicotine-N'-oxide and cotinine-N-oxide were found to range between 11 and 19,750, 13 and 10,475, 10 and 8217, 11 and 3396, and 13 and 1640 ng/mL, respectively. When proposing conservative concentration limits for nicotine consumption prior and/or during the games (50 ng/mL for nicotine, cotinine and trans-3-hydroxycotinine and 25 ng/mL for nicotine-N'-oxide and cotinine-N-oxide), about half of the hockey players were qualified as consumers. These findings significantly support the likelihood of extensive smokeless nicotine consumption. However, since such conclusions can only be hypothesized, the potential use of smokeless tobacco as a doping agent in ice hockey requires further investigation.
Resumo:
BACKGROUND: Epidermal growth factor receptor (EGFR) and its downstream factors KRAS and BRAF are mutated in several types of cancer, affecting the clinical response to EGFR inhibitors. Mutations in the EGFR kinase domain predict sensitivity to the tyrosine kinase inhibitors gefitinib and erlotinib in lung adenocarcinoma, while activating point mutations in KRAS and BRAF confer resistance to the anti-EGFR monoclonal antibody cetuximab in colorectal cancer. The development of new generation methods for systematic mutation screening of these genes will allow more appropriate therapeutic choices. METHODS: We describe a high resolution melting (HRM) assay for mutation detection in EGFR exons 19-21, KRAS codon 12/13 and BRAF V600 using formalin-fixed paraffin-embedded samples. Somatic variation of KRAS exon 2 was also analysed by massively parallel pyrosequencing of amplicons with the GS Junior 454 platform. RESULTS: We tested 120 routine diagnostic specimens from patients with colorectal or lung cancer. Mutations in KRAS, BRAF and EGFR were observed in 41.9%, 13.0% and 11.1% of the overall samples, respectively, being mutually exclusive. For KRAS, six types of substitutions were detected (17 G12D, 9 G13D, 7 G12C, 2 G12A, 2 G12V, 2 G12S), while V600E accounted for all the BRAF activating mutations. Regarding EGFR, two cases showed exon 19 deletions (delE746-A750 and delE746-T751insA) and another two substitutions in exon 21 (one showed L858R with the resistance mutation T590M in exon 20, and the other had P848L mutation). Consistent with earlier reports, our results show that KRAS and BRAF mutation frequencies in colorectal cancer were 44.3% and 13.0%, respectively, while EGFR mutations were detected in 11.1% of the lung cancer specimens. Ultra-deep amplicon pyrosequencing successfully validated the HRM results and allowed detection and quantitation of KRAS somatic mutations. CONCLUSIONS: HRM is a rapid and sensitive method for moderate-throughput cost-effective screening of oncogene mutations in clinical samples. Rather than Sanger sequence validation, next-generation sequencing technology results in more accurate quantitative results in somatic variation and can be achieved at a higher throughput scale.
Resumo:
The integration of geophysical data into the subsurface characterization problem has been shown in many cases to significantly improve hydrological knowledge by providing information at spatial scales and locations that is unattainable using conventional hydrological measurement techniques. The investigation of exactly how much benefit can be brought by geophysical data in terms of its effect on hydrological predictions, however, has received considerably less attention in the literature. Here, we examine the potential hydrological benefits brought by a recently introduced simulated annealing (SA) conditional stochastic simulation method designed for the assimilation of diverse hydrogeophysical data sets. We consider the specific case of integrating crosshole ground-penetrating radar (GPR) and borehole porosity log data to characterize the porosity distribution in saturated heterogeneous aquifers. In many cases, porosity is linked to hydraulic conductivity and thus to flow and transport behavior. To perform our evaluation, we first generate a number of synthetic porosity fields exhibiting varying degrees of spatial continuity and structural complexity. Next, we simulate the collection of crosshole GPR data between several boreholes in these fields, and the collection of porosity log data at the borehole locations. The inverted GPR data, together with the porosity logs, are then used to reconstruct the porosity field using the SA-based method, along with a number of other more elementary approaches. Assuming that the grid-cell-scale relationship between porosity and hydraulic conductivity is unique and known, the porosity realizations are then used in groundwater flow and contaminant transport simulations to assess the benefits and limitations of the different approaches.
Resumo:
A gas chromatographic-mass spectrometric method is presented which allows the determination of chlorzoxazone and 6-hydroxychlorzoxazone after derivatization with the reagent N-tert.-butyldimethylsilyl-N-methyltrifluoroacetamide. No interference was observed from endogenous compounds following the extraction of plasma samples from six different human subjects. The standard curves were linear over a working range of 20 to 4000 ng/ml and of 20 to 1000 ng/ml for chlorzoxazone and 6-hydroxychlorzoxazone, respectively. Recoveries ranged from 65 to 97% for the two compounds and intra- and inter-day coefficients of variation were always less than 9%. The limit of quantitation of the method was found to be 5 ng/ml for the two compounds, hence allowing its use for single low dose pharmacokinetics.
Resumo:
The most valuable pigment of the Roman wall paintings was the red color obtained from powdered cinnabar (Minium Cinnabaris pigment), the red mercury sulfide (HgS), which was brought from mercury (Hg) deposits in the Roman Empire. To address the question of whether sulfur isotope signatures can serve as a rapid method to establish the provenance of the red pigment in Roman frescoes, we have measured the sulfur isotope composition (delta(34) S value in parts per thousand VCDT) in samples of wall painting from the Roman city Aventicum (Avenches, Vaud, Switzerland) and compared them with values from cinnabar from European mercury deposits (Almaden in Spain, Idria in Slovenia, Monte Amiata in Italy, Moschellandsberg in Germany, and Genepy in France). Our study shows that the delta(34) S values of cinnabar from the studied Roman wall paintings fall within or near to the composition of Almaden cinnabar; thus, the provenance of the raw material may be deduced. This approach may provide information on provenance and authenticity in archaeological, restoration and forensic studies of Roman and Greek frescoes. Copyright (c) 2010 John Wiley & Sons, Ltd.
Resumo:
The aim of our study was to provide an innovative headspace-gas chromatography-mass spectrometry (HS-GC-MS) method applicable for the routine determination of blood CO concentration in forensic toxicology laboratories. The main drawback of the GC/MS methods discussed in literature for CO measurement is the absence of a specific CO internal standard necessary for performing quantification. Even if stable isotope of CO is commercially available in the gaseous state, it is essential to develop a safer method to limit the manipulation of gaseous CO and to precisely control the injected amount of CO for spiking and calibration. To avoid the manipulation of a stable isotope-labeled gas, we have chosen to generate in a vial in situ, an internal labeled standard gas ((13)CO) formed by the reaction of labeled formic acid formic acid (H(13)COOH) with sulfuric acid. As sulfuric acid can also be employed to liberate the CO reagent from whole blood, the procedure allows for the liberation of CO simultaneously with the generation of (13)CO. This method allows for precise measurement of blood CO concentrations from a small amount of blood (10 μL). Finally, this method was applied to measure the CO concentration of intoxicated human blood samples from autopsies.
Resumo:
Effective empirical treatment is of paramount importance to improve the outcome of patients with Staphylococcus aureus bacteraemia. We aimed to evaluate a PCR-based rapid diagnosis of methicillin resistance (GeneXpert MRSA) after early detection of S. aureus bacteraemia using matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS). Patients with a first episode of S. aureus bacteraemia identified using MALDI-TOF MS were randomized in a prospective interventional open study between October 2010 and August 2012. In the control group, antibiotic susceptibility testing was performed after MALDI-TOF MS identification on blood culture pellets. In the intervention group, a GeneXpert MRSA was performed after S. aureus identification. The primary outcome was the performance of GeneXpert MRSA directly on blood cultures. We then assessed the impact of early diagnosis of methicillin resistance on the empirical treatment. In all, 197 episodes of S. aureus bacteraemia were included in the study, of which 106 were included in the intervention group. Median time from MALDI-TOF MS identification to GeneXpert MRSA result was 97 min (range 25-250). Detection of methicillin resistance using GeneXpert MRSA had a sensitivity of 99% and a specificity of 100%. There was less unnecessary coverage of MRSA in the intervention group (17.1% versus 29.2%, p 0.09). GeneXpert MRSA was highly reliable in diagnosing methicillin resistance when performed directly on positive blood cultures. This could help to avoid unnecessary prescriptions of anti-MRSA agents and promote the introduction of earlier adequate coverage in unsuspected cases.
Resumo:
Introduction: Ethylglucuronide (EtG) is a direct and specific metabolite of ethanol. Its determination in hair is of increasing interest for detecting and monitoring alcohol abuse. The quantification of EtG in hair requires analytical methods showing highest sensitivity and specificity. We present a fully validated method based on gas chromatography-negative chemical ionization tandem mass spectrometry (GC-NCI-MS/MS). The method was validated using French Society of Pharmaceutical Sciences and Techniques (SFSTP) guidelines which are based on the determination of the total measurement error and accuracy profiles. Methods: Washed and powdered hair is extracted in water using an ultrasonic incubation. After purification by Oasis MAX solid phase extraction, the derivatized EtG is detected and quantified by GC-NCI-MS/MS method in the selected reaction monitoring mode. The transitions m/z 347 / 163 and m/z 347 / 119 were used for the quantification and identification of EtG. Four quality controls (QC) prepared with hair samples taken post mortem from 2 subjects with a known history of alcoholism were used. A proficiency test with 7 participating laboratories was first run to validate the EtG concentration of each QC sample. Considering the results of this test, these samples were then used as internal controls for validation of the method. Results: The mean EtG concentrations measured in the 4 QC were 259.4, 130.4, 40.8, and 8.4 pg/mg hair. Method validation has shown linearity between 8.4 and 259.4 pg/mg hair (r2 > 0.999). The lower limit of quantification was set up at 8.4 pg/mg. Repeatability and intermediate precision were found less than 13.2% for all concentrations tested. Conclusion: The method proved to be suitable for routine analysis of EtG in hair. GC-NCI-MS/MS method was then successfully applied to the analysis of EtG in hair samples collected from different alcohol consumers.