945 resultados para Good performance during a task
Resumo:
Tämä työ on tehty Lappeenrannan teknillisessä yliopistossa, meneillään olevan tuulivoimalasimulaattorin kehitystyön yhteydessä. Työssä käydään läpi simulaattorissa käytettyjen generaattorisillan ja verkkosillan säätöperiaatteita, tehdään katsaus siirtoverkon jännitevikoihin sekä tuulivoimalan toimintaan näissä vikatilanteissa. Työn varsinainen tutkimuskohde on verkkosillan säädön toiminnan simuloiminen siirtoverkon jännitevioissa ja säädön parannusehdotukset.
Resumo:
Six supercritical fluid extraction (SFE) methods were tested, by varying the following operational parameters: CO2 pressure, time and temperature of extraction, type and proportion of static modifier, and Hydromatrix®/sample rate into cell. Firstly, insecticide carbamates were extracted from spiked potatoes samples (fortification level of 0,5 mg.Kg-1) by using SPE procedures, and then final extracts were analyzed HPLC/fluorescence. Good performance was observed with SFE methods that operated with values of temperature and CO2 pressure of 50 ºC and 350 bar, respectively. Best efficiency was obtained when it was used acetonitrile as a modifier (3% on the cell volume), and Hydromatrix®/sample rate of 2:1. Static time was of 1 min; total extraction time was of 35 min; dynamic extraction was performed with 15 mL of CO2, and it was used methanol (2 mL) for the dissolution of the final residue. In such conditions, pesticide recoveries varied from 72 to 94%, depending on the analyzed compound. In higher extraction temperatures, a rapid degradation was observed for some compounds, such as aldicarb and carbaryl; presence of their metabolites was further confirmed by HPLC-APCI/MS in positive mode. Detection limits for chromatographic analysis varied from 0,2 to 1,3 ng.
Resumo:
Relevant aspects of proposed mechanisms of the chemiluminescent reaction of luminol are presented and commented to emphasize its perspectives for kinetic analysis. A careful search for analytical applications of this reaction is discussed in order to point out new trends of the studies. Kinetic analysis using the luminol reaction is proposed to be a very attractive due to the good performance of the reaction in analytical applications and the positive characteristics of kinetic analysis, such as low cost and sensibility. It is pointed out that kinetic analysis using the chemiluminescent reaction of luminol should be encouraged.
Resumo:
The central goal of food safety policy in the European Union (EU) is to protect consumer health by guaranteeing a high level of food safety throughout the food chain. This goal can in part be achieved by testing foodstuffs for the presence of various chemical and biological hazards. The aim of this study was to facilitate food safety testing by providing rapid and user-friendly methods for the detection of particular food-related hazards. Heterogeneous competitive time-resolved fluoroimmunoassays were developed for the detection of selected veterinary residues, that is coccidiostat residues, in eggs and chicken liver. After a simplified sample preparation procedure, the immunoassays were performed either in manual format with dissociation-enhanced measurement or in automated format with pre-dried assay reagents and surface measurement. Although the assays were primarily designed for screening purposes providing only qualitative results, they could also be used in a quantitative mode. All the developed assays had good performance characteristics enabling reliable screening of samples at concentration levels required by the authorities. A novel polymerase chain reaction (PCR)-based assay system was developed for the detection of Salmonella spp. in food. The sample preparation included a short non-selective pre-enrichment step, after which the target cells were collected with immunomagnetic beads and applied to PCR reaction vessels containing all the reagents required for the assay in dry form. The homogeneous PCR assay was performed with a novel instrument platform, GenomEra™, and the qualitative assay results were automatically interpreted based on end-point time-resolved fluorescence measurements and cut-off values. The assay was validated using various food matrices spiked with sub-lethally injured Salmonella cells at levels of 1-10 colony forming units (CFU)/25 g of food. The main advantage of the system was the exceptionally short time to result; the entire process starting from the pre-enrichment and ending with the PCR result could be completed in eight hours. In conclusion, molecular methods using state-of-the-art assay techniques were developed for food safety testing. The combination of time-resolved fluorescence detection and ready-to-use reagents enabled sensitive assays easily amenable to automation. Consequently, together with the simplified sample preparation, these methods could prove to be applicable in routine testing.
Resumo:
This paper presents a new way for the construction of silver electrodes utilizing recordable CDs. The new electrodes were explored for the quantification of chloride (by potentiometry/FIA), cyanide (by amperometry/FIA) and for lead analysis (by square wave voltammetry). For the flowing measurements, a digital multimeter, connected to a microcomputer (via RS 232 interface) was used to collect directly the potential signal (for Cl- measurements) or to take the output signal from a potentiostat (for CN- measurements). The square wave voltammetry analysis was performed in a commercial instrument. The results shown good performance of the new electrodes and the detection limit (s/n = 3) attained for these three analytes were: 0.2, 50, and 200 µg L-1 for Pb2+, Cl-, and CN- respectively.
Resumo:
Research on limnology in southern Europe had achieved a notable presence in the international arena before the onset of the current dramatic cuts in public investment in science. We assessed the limnological research published in peer-reviewed journals by Spanish and Portuguese (i.e., Iberian) researchers during the decade prior to the economic recession (2000 to 2009). The Thompson Reuters Web of Knowledge database was used to retrieve all publications on limnology authored by researchers affiliated with Spanish or Portuguese institutions independently of the geographical setting of the study. The publishing pattern was characterised in terms of authors, journals, and citation statistics. In addition, a thematic characterisation of the research was performed by a manual assignation of several categorical descriptors combined with a blind word count analysis. Iberian researchers produced an annual mean of 278 papers on limnology. Papers were published in journals that had impact factors ranging from 0.1 to 31.4, with a mean of 2.0. Based on citations, the impact of the Iberian limnological research was not due to a few highly cited papers but rather to a wide number of publications; each paper received a mean of 8 citations. The Iberian limnological research involved up to 5460 researchers, with a mean of 4.3 authors per paper. The research largely focused on fluvial systems, with 47 % of total publications (2778) devoted to these ecosystems. There was a dominant focus on local, within-system aspects of study sites and the research was mostly restricted to the Iberian Peninsula; larger spatial scales of analysis (i.e., landscape, regional, or global) tended to be overlooked. Iberian research addressed fundamental (75 %) rather than applied (17 %) or methodological (5 %) questions and was vastly dominated by observational approaches (75 %). Interestingly, Iberian limnological research increased its scientific productivity during the analysed decade at a higher rate than its international counterpart (increase of 119 %). Overall, Iberian research on limnology appeared to be in good health during the analysed decade. Certain areas have been more studied than others, which opens opportunities to develop new research.
Resumo:
Synchronous machines with an AC converter are used mainly in large drives, for example in ship propulsion drives as well as in rolling mill drives in steel industry. These motors are used because of their high efficiency, high overload capacity and good performance in the field weakening area. Present day drives for electrically excited synchronous motors are equipped with position sensors. Most drives for electrically excited synchronous motors will be equipped with position sensors also in future. This kind of drives with good dynamics are mainly used in metal industry. Drives without a position sensor can be used e.g. in ship propulsion and in large pump and blower drives. Nowadays, these drives are equipped with a position sensor, too. The tendency is to avoid a position sensor if possible, since a sensor reduces the reliability of the drive and increases costs (latter is not very significant for large drives). A new control technique for a synchronous motor drive is a combination of the Direct Flux Linkage Control (DFLC) based on a voltage model and a supervising method (e.g. current model). This combination is called Direct Torque Control method (DTC). In the case of the position sensorless drive, the DTC can be implemented by using other supervising methods that keep the stator flux linkage origin centered. In this thesis, a method for the observation of the drift of the real stator flux linkage in the DTC drive is introduced. It is also shown how this method can be used as a supervising method that keeps the stator flux linkage origin centered in the case of the DTC. In the position sensorless case, a synchronous motor can be started up with the DTC control, when a method for the determination of the initial rotor position presented in this thesis is used. The load characteristics of such a drive are not very good at low rotational speeds. Furthermore, continuous operation at a zero speed and at a low rotational speed is not possible, which is partly due to the problems related to the flux linkage estimate. For operation in a low speed area, a stator current control method based on the DFLC modulator (DMCQ is presented. With the DMCC, it is possible to start up and operate a synchronous motor at a zero speed and at low rotational speeds in general. The DMCC is necessary in situations where high torque (e.g. nominal torque) is required at the starting moment, or if the motor runs several seconds at a zero speed or at a low speed range (up to 2 Hz). The behaviour of the described methods is shown with test results. The test results are presented for the direct flux linkage and torque controlled test drive system with a 14.5 kVA, four pole salient pole synchronous motor with a damper winding and electric excitation. The static accuracy of the drive is verified by measuring the torque in a static load operation, and the dynamics of the drive is proven in load transient tests. The performance of the drive concept presented in this work is sufficient e.g. for ship propulsion and for large pump drives. Furthermore, the developed methods are almost independent of the machine parameters.
Resumo:
Les últimes dades de l'estudi europeu del 2014, sobre la violència de parella indiquen que gairebé 62 milions de dones europees, havien sofert actes de violència de gènere, entre els quals es destaca els relacionats amb la violència de parella (VP). Els maltractaments constitueixen un problema molt greu que genera al nostre país cada vegada més alarma social i més actuacions legals i professionals per fer-li front. El sistema de salut és, amb freqüència, el primer lloc al que les víctimes de violència domèstica acudeixen a la recerca d'assessorament i ajuda, sent aquest el motiu pel qual els professionals de la salut tenen un paper central per a la seva assistència. Aquests formen part implicada en el sistema de detecció, atenció i actuació. Per això, els plans d'estudi de Grau d'Infermeria recullen en el BOE la formació en VP des de l’àmbit universitari. L’objectiu del nostre estudi consisteix en la identificació de la percepció i dels coneixements en relació a la violència de parella dels estudiants del Grau d’Infermeria de la Universitat de Girona durant el curs acadèmic 2012-2013. Per a dur-lo a terme es va realitzar un anàlisi quantitatiu dels resultats a través de l’administració d’una enquesta sobre sis aspectes de la VP, l’enquesta incloïa el perfil demogràfic (sexe, edat i anys d'estudi) dels estudiants i les declaracions relatives a les seves percepcions i coneixements sobre la VP: causes d'abús; la identificació de les dones objecte de VP i del seus autors; creences de les infermeres; funcions perceptibles; i la preparació educativa. Els estudiants del Grau d’Infermeria mostren tenir un bon coneixement sobre les causes del abús en VP, així com una formació adequada. També cal destacar que un 54,42% dels alumnes enquestats es veuen capacitats per afrontar un cas de VP com a infermer/a. S’observa una millora de la formació educativa en el transcurs acadèmic. En 1r curs un 40,09% té una bona formació, aquest valor augmenta fins a un 56,58% a tercer curs, baixant lleugerament fins un 44,27% a 4rt curs. Els resultats obtinguts són semblats a estudis de mostres similars en estudiants d'infermeria de Memphis (EUA) i de la University of Southern Queensland (Austràlia) quant a coneixements i percepció sobre la VP. Encara que els resultats mostren un coneixement i una percepció sobre la VP adequada, destaquem que això no succeeix en gairebé un 40% dels enquestats. La introducció de matèries específiques sobre igualtat i sobre violència contra la dona en els plans d’estudis, pot esdevenir una mesura preventiva per revisar i corregir possibles mites i creences en VP. Per tant, és necessari millorar la formació del currículum en estudiants d'infermeria per la importància d'aquest greu problema de salut pública, donant major èmfasis en la satisfacció de les necessitats emocionals i en la comprensió dels diferents enfocaments en VP, especialment en mesures de prevenció i educació
Resumo:
This paper presents an easy and practical procedure to obtain silica-based C-8 type sorbents for use in solid-phase extraction. The materials are prepared by depositing poly(methyloctylsiloxane), PMOS, on the silica support. Two different treatments for immobilization were used: thermal treatment or gamma irradiation. Suitable recoveries were obtained after pre-concentration of dilute solutions, at the ng/L level, of a mixture of pesticides, indicating the good performance of the materials.
Resumo:
In this work the separation of the chiral anesthetic compounds ketamine and bupivacaine was development using two chiral stationary phases (CSP). Ketamine enantiomers were well separate in the polysaccharide-based CSP (microcrystalline cellulose triacetate - MCTA) while bupivacaine in the tartardiamide-based CSP (Kromasil CHI-TBB). In both cases, the effect of temperature was investigated under analytical conditions. An improvement in the separation performance with temperature was observed. Thermodynamic parameters were evaluated by the van't Hoff plot. We concluded that enthalpic effects controlled the retention in these chiral columns. The enantiomers of ketamine and bupivacaine were separated under overloaded conditions with a good performance.
Resumo:
This paper presents an IR and Raman experiment executed during the teaching of the course "Chemical Bonds" for undergraduated students of Science and Technology and Chemistry at the Federal University of ABC, in order to facilitate and encourage the teaching and learning of group theory. Some key aspects of this theory are also outlined. We believe that student learning was more significant with the introduction of this experiment, because there was an increase in the discussions level and in the performance during evaluations. This work also proposes a multidisciplinary approach to include the use of quantum chemistry tools.
Resumo:
The DGT technique allows one to measure quantitatively free and labile metal species in aquatic systems. Nevertheless, for this approach, knowledge is required of the diffusion coefficients of the analytes in a diffusive layer. In this study, the diffusion coefficients of Hg(II), As(III), Mn(II), Mg(II), Cu(II), Cd(II) were determined in agarose gel and those of Ba(II), Cd(II), Cu(II), Mg(II), Mn(II) e Zn(II) in cellulose acetate membranes. These materials presented good performance and the reported results can be used as a data base for further DGT studies.
Resumo:
Electrodes modified with poly(5-amino-1-naphthol)/Prussian blue (poly(5-NH2-1-NAP)/PB) hybrid films are able to electrochemically reduce H2O2 in medium containing an excess of Na+ cations. This is an important advantage for biosensing applications over electrodes in which only conventionally (electro) deposited Prussian blue is present. Consequently, the aim of this work was to examine the application of templates of ordered arrays of colloidal poly(styrene) spheres (800, 450 and 100 nm in diameter) to produce inverse opal structures of poly(5-NH2-1-NAP)/PB hybrid platforms, in an effort to study the influence of the increase in surface area/volume ratio and higher exposition of the mediator active sites on material performance during H2O2 determination employing the different sized porous structures. Moreover, since the accentuated hydrophilic character of poly(5-NH2-1-NAP)/PB also allows H2O2 electrochemical reduction in inner active sites, issues concerning the amount of mediator electrodeposited on the electrode were also reflected in the observed results.
Resumo:
17α-methyltestosterone (17α-MT) is a hormone used in medicine and aquaculture which can be found in natural waters. It is considered an emerging organic pollutant and its accurate and precise analysis is required. Therefore, this study presents the in-house validation of a new voltammetric methodology for 17α-MT analysis in natural waters. A hanging mercury drop electrode and NaOH 5.0×10-3 mol L-1 solution as the electrolyte were employed in the voltammetric determinations. To confirm the presence of 17α-MT in water samples quantitative analysis was performed by ESI-MS/MS. The methodology exhibited good selectivity, linearity, accuracy (recovery of between 100.4 and 108.8%) and precision (RSDs for repeatability of 2.85% and for intermediate precision of 14.10%, with n = 5, respectively). LOD and LOQ were 3.07 µg L-1 and 10.78 µg L-1, respectively. The methodology was suitable for determination of 17α-MT in natural waters due to low-cost, good performance and no sample pre-treatment required.
Resumo:
This work describes the development of an alternative acetate bath for the electrochemical codeposition of Ni-Cu-Fe electrodes at low pH that is stable for several weeks and produces electrodes with good performance for chlor-alkali electrolysis. Physical characterization of the electrode surface was made using X ray absorption spectroscopy (XAS), scanning electron microscopy (SEM) and energy dispersive analysis (EDX). The evaluation of the material as electrocatalyst for the hydrogen evolution reaction (her) was carried out in brine solution (160 g L-1 NaCl + 150 g L-1 NaOH) at different temperatures through steady-state polarization curves. The Ni-Cu-Fe electrodes obtained with this bath have shown low overpotentials for the her, around 0.150 V at 353 K, and good stability under continuous long-term operation for 260 hours. One positive aspect of this cathode is that the polarization behavior of the material shows only one Tafel slope over the temperature range of 298 - 353 K.