980 resultados para Geostatistical inversion


Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Coronary in-stent restenosis cannot be directly assessed by magnetic resonance angiography (MRA) because of the local signal void of currently used stainless steel stents. The aim of this study was to investigate the potential of a new, dedicated, coronary MR imaging (MRI) stent for artifact-free, coronary MRA and in-stent lumen and vessel wall visualization. METHODS AND RESULTS: Fifteen prototype stents were deployed in coronary arteries of 15 healthy swine and investigated with a double-oblique, navigator-gated, free-breathing, T2-prepared, 3D cartesian gradient-echo sequence; a T2-prepared, 3D spiral gradient-echo sequence; and a T2-prepared, 3D steady-state, free-precession coronary MRA sequence. Furthermore, black-blood vessel wall imaging by a dual-inversion-recovery, turbo spin-echo sequence was performed. Artifacts of the stented vessel segment and signal intensities of the coronary vessel lumen inside and outside the stent were assessed. With all investigated sequences, the vessel lumen and wall could be visualized without artifacts, including the stented vessel segment. No signal intensity alterations inside the stent when compared with the vessel lumen outside the stent were found. CONCLUSIONS: The new, coronary MRI stent allows for completely artifact-free coronary MRA and vessel wall imaging.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The impact of topography and mixed pixels on L-band radiometric observations over land needs to be quantified to improve the accuracy of soil moisture retrievals. For this purpose, a series of simulations has been performed with an improved version of the soil moisture and ocean salinity (SMOS) end-to-end performance simulator (SEPS). The brightness temperature generator of SEPS has been modified to include a 100-m-resolution land cover map and a 30-m-resolution digital elevation map of Catalonia (northeast of Spain). This high-resolution generator allows the assessment of the errors in soil moisture retrieval algorithms due to limited spatial resolution and provides a basis for the development of pixel disaggregation techniques. Variation of the local incidence angle, shadowing, and atmospheric effects (up- and downwelling radiation) due to surface topography has been analyzed. Results are compared to brightness temperatures that are computed under the assumption of an ellipsoidal Earth.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Nucleotide composition analyses of bacterial genomes such as cumulative GC skew highlight the atypical, strongly asymmetric architecture of the recently published chromosome of Idiomarina loihiensis L2TR, suggesting that an inversion of a 600-kb chromosomal segment occurred. The presence of 3.4-kb inverted repeated sequences at the borders of the putative rearrangement supports this hypothesis. Reverting in silico this segment restores (1) a symmetric chromosome architecture; (2) the co-orientation of transcription of all rRNA operons with DNA replication; and (3) a better conservation of gene order between this chromosome and other gamma-proteobacterial ones. Finally, long-range PCRs encompassing the ends of the 600-kb segment reveal the existence of the reverted configuration but not of the published one. This demonstrates how cumulative nucleotide-skew analyses can validate genome assemblies.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Le syndrome de Brugada, une affection rythmique du sujet jeune potentiellement fatale, se manifeste sur l'ECG par un bloc de branche droit (BBD) complet, avec sus-décalage majeur du segment ST et inversion des ondes Τ de V1 à V3 appelé pattern de type 1. Cette présentation peut être intermittente. Les manifestations incomplètes du syndrome de Brugada sont appelées patterns de types 2 ou 3, et sont caractérisées par un BBD incomplet et un sus-décalage ST plus ou moins prononcé dans les dérivations V-, et V2 de l'ECG. Cette description, cependant, est aussi celle du BBD incomplet fréquemment rencontré chez les sujets jeunes, de moins de 40 ans, et présent dans 3% de la population. Bo nombre de ces sujets sont donc référés pour une recherche de syndrome de Brugada. Le but de cette thèse est donc d'évaluer de nouveaux critères permettant de discriminer les BBD incomplets, banals, des sujets porteurs d'un syndrome de Brugada de types 2 ou 3. Trente-huit patients avec un pattern de Brugada de types 2 et 3, référés pour un test médicamenteux utilisant un antiarythmique révélant un pattern de type 1 chez les sujets porteurs, ont été inclus dans l'étude. Avant le test médicamenteux, deux angles ont été mesurés sur les dérivations Vi et/ou V2 : a, l'angle entre une ligne verticale et la descente de l'onde r', et β, l'angle entre la montée de l'onde S et la descente de l'onde r'. Les mesure à l'état basai des deux angles, seules ou combinées avec la durée du QRS, on été comparées entre les patients avec une épreuve pharmacologique positive et ceux dont l'épreuve s'est révélée négative (i.e. servant de groupe contrôle car porteur d'un véritable BBD incomplet). Des courbes ROC ont été établies afin de déterminer les valeurs d'angles les plus discriminantes. La moyenne des angles β était significativement plus petite chez les 14 patients avec un test pharmacologique négatif comparé aux 24 patients avec un test positif. La valeur optimale pour l'angle β était de 58°, ce qui donnait une valeur prédictive positive de 73% et une valeur prédictive négative de 97% pour une conversion en pattern de type 1 lors du test pharmacologique. L'angle α était un peu moins sensible et spécifique que β. Quand les angles étaient combinés à la durée du QRS, on observait une discrète amélioration de la discrimination entre les deux populations. Notre travail permet donc, chez des patients suspects d'un syndrome de Brugada, de discriminer entre un BBD incomplet et les patterns de Brugada types 2 et 3 en utilisant un critère simple basé sur l'ECG de surface potentiellement applicable au lit du patient

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Uncertainty quantification of petroleum reservoir models is one of the present challenges, which is usually approached with a wide range of geostatistical tools linked with statistical optimisation or/and inference algorithms. The paper considers a data driven approach in modelling uncertainty in spatial predictions. Proposed semi-supervised Support Vector Regression (SVR) model has demonstrated its capability to represent realistic features and describe stochastic variability and non-uniqueness of spatial properties. It is able to capture and preserve key spatial dependencies such as connectivity, which is often difficult to achieve with two-point geostatistical models. Semi-supervised SVR is designed to integrate various kinds of conditioning data and learn dependences from them. A stochastic semi-supervised SVR model is integrated into a Bayesian framework to quantify uncertainty with multiple models fitted to dynamic observations. The developed approach is illustrated with a reservoir case study. The resulting probabilistic production forecasts are described by uncertainty envelopes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

To improve the yield of the cytogenetic analysis in patients with acute nonlymphocytic leukemia (ANLL), six culture conditions for bone marrow or peripheral blood cells were tested in parallel. Two conditioned media (CM), phytohemagglutinin leukocyte PHA-LCM and 5637 CM, nutritive elements (NE), and methotrexate (MTX) cell synchronization were investigated in 14 patients presenting with either inv(16)/ t(16;16) (group 1, n = 9 patients) or t(15;17) (group 2, n = 5). The criteria used to identify the most favorable culture conditions were the mitotic index (MI), the morphological index (MorI), and the percentage of abnormal metaphases. In the presence of PHA-LCM and 5637 CM, the MI were significantly increased in group 2, whereas in the MTX conditions, MI remained very low in both groups. The values of the MorI did not reveal any significant changes in chromosome resolution between the conditions in either group. The addition of NE did not have a positive effect in quantity or quality of metaphases. Because of the variability of the response of leukemic cells to different stimulations in vitro, several culture conditions in parallel are required to ensure a satisfactory yield of the chromosome analysis in ANLL.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Quantification of short-echo time proton magnetic resonance spectroscopy results in >18 metabolite concentrations (neurochemical profile). Their quantification accuracy depends on the assessment of the contribution of macromolecule (MM) resonances, previously experimentally achieved by exploiting the several fold difference in T(1). To minimize effects of heterogeneities in metabolites T(1), the aim of the study was to assess MM signal contributions by combining inversion recovery (IR) and diffusion-weighted proton spectroscopy at high-magnetic field (14.1 T) and short echo time (= 8 msec) in the rat brain. IR combined with diffusion weighting experiments (with δ/Δ = 1.5/200 msec and b-value = 11.8 msec/μm(2)) showed that the metabolite nulled spectrum (inversion time = 740 msec) was affected by residuals attributed to creatine, inositol, taurine, choline, N-acetylaspartate as well as glutamine and glutamate. While the metabolite residuals were significantly attenuated by 50%, the MM signals were almost not affected (< 8%). The combination of metabolite-nulled IR spectra with diffusion weighting allows a specific characterization of MM resonances with minimal metabolite signal contributions and is expected to lead to a more precise quantification of the neurochemical profile.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Full signal intensity (1)H-[(13)C] NMR spectroscopy, combining a preceding (13)C-editing block based on an inversion BISEP (B(1)-insensitive spectral editing pulse) with a spin-echo coherence-based localization, was developed and implemented at 14.1 T. (13)C editing of the proposed scheme was achieved by turning on and off the (13)C adiabatic full passage in the (13)C-editing block to prepare inverted and noninverted (13)C-coupled (1)H coherences along the longitudinal axis prior to localization. The novel (1)H-[(13)C] NMR approach was applied in vivo under infusion of the glia-specific substrate [2-(13)C] acetate. Besides a approximately 50% improvement in sensitivity, spectral dispersion was enhanced at 14.1 T, especially for J-coupled metabolites such as glutamate and glutamine. A more distinct spectral structure at 1.9-2.2 ppm(parts per million) was observed, e.g., glutamate C3 showed a doublet pattern in both simulated (1)H spectrum and in vivo (13)C-edited (1)H NMR spectra. Besides (13)C time courses of glutamate C4 and glutamine C4, the time courses of glutamate C3 and glutamine C3 obtained by (1)H-[(13)C] NMR spectroscopy were reported for the first time. Such capability should greatly improve the ability to study neuron-glial metabolism using (1)H-observed (13)C-edited NMR spectroscopy.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The combination of cardiac viability and functional information enhances the identification of different heart tissues in the setting of ischemic heart disease. A method has recently been proposed for obtaining black-blood delayed-enhancement (DE) viability images using the stimulated-echo acquisition mode (STEAM) MRI pulse sequence in a single short breathhold. The method was validated against conventional inversion-recovery (IR) DE images for identifying regions of myocardial infarction (MI). The method was based on the acquisition of three consecutive images of the same anatomical slice. One image has T(1)-weighted contrast in which infarction appears bright. The two other images are used to construct an anatomical image of the heart, which is combined with the first image to produce a black-blood viability image. However, using appropriate modulation and demodulation frequencies, the latter two images bear useful information about myocardial deformation that results in a cardiac strain-encoding (SENC) functional image. In this work, a method is proposed for obtaining three consecutive SENC images in a single acquisition that can be combined to produce a composite image of the heart, which shows both functional and viability information. The proposed technique reduces scan time by one-half, compared with separate acquisitions of functional and viability images, and alleviates misregistration problems caused by separate breathholds.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We have developed a processing methodology that allows crosshole ERT (electrical resistivity tomography) monitoring data to be used to derive temporal fluctuations of groundwater electrical resistivity and thereby characterize the dynamics of groundwater in a gravel aquifer as it is infiltrated by river water. Temporal variations of the raw ERT apparent-resistivity data were mainly sensitive to the resistivity (salinity), temperature and height of the groundwater, with the relative contributions of these effects depending on the time and the electrode configuration. To resolve the changes in groundwater resistivity, we first expressed fluctuations of temperature-detrended apparent-resistivity data as linear superpositions of (i) time series of riverwater-resistivity variations convolved with suitable filter functions and (ii) linear and quadratic representations of river-water-height variations multiplied by appropriate sensitivity factors; river-water height was determined to be a reliable proxy for groundwater height. Individual filter functions and sensitivity factors were obtained for each electrode configuration via deconvolution using a one month calibration period and then the predicted contributions related to changes in water height were removed prior to inversion of the temperature-detrended apparent-resistivity data. Applications of the filter functions and sensitivity factors accurately predicted the apparent-resistivity variations (the correlation coefficient was 0.98). Furthermore, the filtered ERT monitoring data and resultant time-lapse resistivity models correlated closely with independently measured groundwater electrical resistivity monitoring data and only weakly with the groundwater-height fluctuations. The inversion results based on the filtered ERT data also showed significantly less inversion artefacts than the raw data inversions. We observed resistivity increases of up to 10% and the arrival time peaks in the time-lapse resistivity models matched those in the groundwater resistivity monitoring data.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

AIMS: Although the coronary artery vessel wall can be imaged non-invasively using magnetic resonance imaging (MRI), the in vivo reproducibility of wall thickness measures has not been previously investigated. Using a refined magnetization preparation scheme, we sought to assess the reproducibility of three-dimensional (3D) free-breathing black-blood coronary MRI in vivo. METHODS AND RESULTS: MRI vessel wall scans parallel to the right coronary artery (RCA) were obtained in 18 healthy individuals (age range 25-43, six women), with no known history of coronary artery disease, using a 3D dual-inversion navigator-gated black-blood spiral imaging sequence. Vessel wall scans were repeated 1 month later in eight subjects. The visible vessel wall segment and the wall thickness were quantitatively assessed using a semi-automatic tool and the intra-observer, inter-observer, and inter-scan reproducibilities were determined. The average imaged length of the RCA vessel wall was 44.5+/-7 mm. The average wall thickness was 1.6+/-0.2 mm. There was a highly significant intra-observer (r=0.97), inter-observer (r=0.94), and inter-scan (r=0.90) correlation for wall thickness (all P<0.001). There was also a significant agreement for intra-observer, inter-observer, and inter-scan measurements on Bland-Altman analysis. The intra-class correlation coefficients for intra-observer (r=0.97), inter-observer (r=0.92), and inter-scan (r=0.86) analyses were also excellent. CONCLUSION: The use of black-blood free-breathing 3D MRI in conjunction with semi-automated analysis software allows for reproducible measurements of right coronary arterial vessel-wall thickness. This technique may be well-suited for non-invasive longitudinal studies of coronary atherosclerosis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: Acute myeloid leukemia (AML) with inv(3)(q21q26.2)/t(3;3)(q21;q26.2) [inv(3)/t(3;3)] is recognized as a distinctive entity in the WHO classification. Risk assignment and clinical and genetic characterization of AML with chromosome 3q abnormalities other than inv(3)/t(3;3) remain largely unresolved. PATIENTS AND METHODS: Cytogenetics, molecular genetics, therapy response, and outcome analysis were performed in 6,515 newly diagnosed adult AML patients. Patients were treated on Dutch-Belgian Hemato-Oncology Cooperative Group/Swiss Group for Clinical Cancer Research (HOVON/SAKK; n = 3,501) and German-Austrian Acute Myeloid Leukemia Study Group (AMLSG; n = 3,014) protocols. EVI1 and MDS1/EVI1 expression was determined by real-time quantitative polymerase chain reaction. RESULTS: 3q abnormalities were detected in 4.4% of AML patients (288 of 6,515). Four distinct groups were defined: A: inv(3)/t(3;3), 32%; B: balanced t(3q26), 18%; C: balanced t(3q21), 7%; and D: other 3q abnormalities, 43%. Monosomy 7 was the most common additional aberration in groups (A), 66%; (B), 31%; and (D), 37%. N-RAS mutations and dissociate EVI1 versus MDS1/EVI1 overexpression were associated with inv(3)/t(3;3). Patients with inv(3)/t(3;3) and balanced t(3q21) at diagnosis presented with higher WBC and platelet counts. In multivariable analysis, only inv(3)/t(3;3), but not t(3q26) and t(3q21), predicted reduced relapse-free survival (hazard ratio [HR], 1.99; P < .001) and overall survival (HR, 1.4; P = .006). This adverse prognostic impact of inv(3)/t(3;3) was enhanced by additional monosomy 7. Group D 3q aberrant AML also had a poor outcome related to the coexistence of complex and/or monosomal karyotypes and cryptic inv(3)/t(3;3). CONCLUSION: Various categories of 3q abnormalities in AML can be distinguished according to their clinical, hematologic, and genetic features. AML with inv(3)/t(3;3) represents a distinctive subgroup with unfavorable prognosis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this study was to evaluate a free-breathing three-dimensional (3D) dual inversion-recovery (DIR) segmented k-space gradient-echo (turbo field echo [TFE]) imaging sequence at 3T for the quantification of aortic vessel wall dimensions. The effect of respiratory motion suppression on image quality was tested. Furthermore, the reproducibility of the aortic vessel wall measurements was investigated. Seven healthy subjects underwent 3D DIR TFE imaging of the aortic vessel wall with and without respiratory navigator. Subsequently, this sequence with respiratory navigator was performed twice in 10 healthy subjects to test its reproducibility. The signal-to-noise (SNR), contrast-to-noise ratio (CNR), vessel wall sharpness, and vessel wall volume (VWV) were assessed. Data were compared using the paired t-test, and the reproducibility of VWV measurements was evaluated using intraclass correlation coefficients (ICCs). SNR, CNR, and vessel wall sharpness were superior in scans performed with respiratory navigator compared to scans performed without. The ICCs concerning intraobserver, interobserver, and interscan reproducibility were excellent (0.99, 0.94, and 0.95, respectively). In conclusion, respiratory motion suppression substantially improves image quality of 3D DIR TFE imaging of the aortic vessel wall at 3T. Furthermore, this optimized technique with respiratory motion suppression enables assessment of aortic vessel wall dimensions with high reproducibility.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We report here on the growth of NiFe2O4 epitaxial thin films of different thickness (3 nm ¿ t ¿ 32 nm) on single crystalline substrates having spinel (MgAl2O4) or perovskite (SrTiO3) structure. Ultrathin films, grown on any of those substrates, display a huge enhancement of the saturation magnetization: we will show that partial cationic inversion may account for this enhancement, although we will argue that suppression of antiparallel collinear spin alignment due to size-effects cannot be excluded. Besides, for thicker films, the magnetization of films on MAO is found to be similar to that of bulk ferrite; in contrast, the magnetization of films on STO is substantially lower than bulk. We discuss on the possible mechanisms leading to this remarkable difference of magnetization.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

High optical power density of 0.5 mW/cm2, external quantum efficiency of 0.1%, and population inversion of 7% are reported from Tb+-implanted silicon-rich silicon nitride/oxide light emitting devices. Electrical and electroluminescence mechanisms in these devices were investigated. The excitation cross section for the 543 nm Tb3+ emission was estimated under electrical pumping, resulting in a value of 8.2 × 10−14 cm2, which is one order of magnitude larger than one reported for Tb3+:SiO2 light emitting devices. These results demonstrate the potentiality of Tb+-implanted silicon nitride material for the development of integrated light sources compatible with Si technology.