992 resultados para Estabilidade de tensão
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
A trial was carried out with the purpose of evaluating the effect of different management systems applied between the rows of rubber trees (Hevea brasiliensis) on the aggregate stability in water of Dark Red Latosol, with clayey texture from the Municipality of Jaboticabal (SP) and Yellow Red Podzolic, sandy/medium texture fromthe Municipality of Tabapua (SP). The treatments consisted of disk harrowing, Pueraria phaseoloides and mowing. The soil samples were withdrawn after seven years of application of these management systems from depths of 0-0.1, 0.1-0.2, 0.2-0.3, and 0.3-0.4 m. The stability of the aggregates was obtained in sieves with size classes of 8-4, 4-2, 2-1, 1-0.5, 0.5-0.125, and < 0.125 mm. The Pueraria phaseoloides gave a significant difference regarding the distribution of the aggregates on the superficial layer (10 cm) when compared to the other management systems, presenting a higher distribution of larger sized aggregates on the Dark Red Latosol. The tillage management for this same depth presented higher values of small sized aggregates on both soils. The organic matter on the soils showed a direct and significant relation to the stability of the larger sized aggregates and an inverse relation with the stability of the smaller sized aggregates.
Resumo:
Pós-graduação em Matemática Universitária - IGCE
Resumo:
This research evaluated the surgical stabilily in patients with mandibular prognathism and retrognathism in which was used sagital split technic to correct those detormities. Twelve patients were selected from the clinic of only one experienced surgeon. Six patients presenter a Class III 6 a Class II molar relationship. A comparative cefalometric analysis using linear and angular measurements was performed of pre-surgery, imediate pós-surgery and 1 year follow-up. The following conclusions were obtained. 1 The Dal Pont sagital split technic modified by Epker to correct mandibular prognathisn and retroghnatism is a stable technic and must be indicated to correct those deformities. 2 Small relapses are easily corrected by the post-surgical orthodontic treatment. 3 A small over correction is advised in cases of large mandibular advancements or set bascks. 4 In those cases which a large amount of mandibular retrusion on advancement need to be performed, a combination of maxillary and mandibular surgery should be used. Rigid fixation technic is also indicated in those cases
Resumo:
Pós-graduação em Engenharia Mecânica - FEB
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
When implants are installed immediately after tooth extraction may occur anchoring primary decreased, delay or failure of osseointegration process. This occurs because of the large interface between the surrounding walls of the socket and the surface of the implant. For reconstruction, replacement or filling of bone defects the solution can be obtained with the use of autogenous, heterogenous or allogeneic bone grafts. However, these grafts suffer certain drawbacks, particularly a high rate of donor site morbidity, limited amounts of available bone, and the additional operative time required for harvest. For these reasons, intensive efforts have been directed toward developing alternative substances for to either augment or substitute. In this paper, we will examine some of the commonly used materials : fibrin and calcium phosphate.
Resumo:
The association of mandibular distal extension removable partial dentures with an osteointegrated implant is a treatment option at hasn't been fully explored by modern rehabilitation dentistry yet. The objective of this study is to evaluate, by means of the bidimensional method of finite elements, the distribution of tension on the structures supporting the distal extension removable partial denture (DERPD), associated to a 10.0 x 3.75 mm osteointegrated implant with an ERA retention system, in alveolar ridges of different shapes. Eight models were created, representing, from a sagittal perspective: Model A (MA) – a half arch with a horizontal ridge without posterior support, with the presence of the lower left canine, and a conventional DERPD, with metallic support in the incisal aspect of this canine, as replacement for the first and second pre-molars and the first and second molars of the lower left half arch; Model B (MB) – similar to MA, but different because of the presence of a 3.75 x 10.00 mm implant with an associated ERA retention system in the posterior region of the DERPD base; Model C (MC) - similar to MA, however with a distally ascending ridge format; Model D (MD) – similar to MC, but different because there is an implant associated to a retention system; Model E (ME) - similar to MA, however with a distally descending ridge format; Model F (MF) – similar to ME, but ditfferent in the sense that there is an implant with an associated ERA retention system; Model G (MG) – similar to MA, however with a distally descending-ascending ridge format; Model H (MH) – similar to MG, but different in the sense that there is an implant with an associated ERA retention system. The finite element program ANSYS 9.0 was used to load the models with vertical forces of 50 N, on each cuspid tip. The format of distal descending edge (ME and MF) was that presented worse results, so in the models with conventional RPD as in the models with RPD associated to the implant and ERA system of retention, for the structures gingival mucosa and tooth support. 1) the distally descending ridge presented the most significant stress in the model with the conventional RPD (ME) or with a prosthesis associated to an implant (MF) and 2) the horizontal ridge (MB) provided more relief to the support structures, such as the tooth and the spongy bone, when there was an implant associated to an ERA retention system. The incorporation of the implants with the ERA system retention, in the posterior area of the toothless edge, it promotes larger stability and retention to PPREL, improving the patient's masticatory acting and, consequently, its comfort and function.
Resumo:
The objective was to evaluate the effect of thermocycling on the color variation of three different composite resins . We studied was Resin Enamel on 3 levels : ( Esthetic X , Opallis and Venus ) ; Resin Dentin in three levels : ( Esthetic X , Opallis and Venus ) and Thermocycling on level 1 : ( 3,000 cycles ) ; variable was the change of color gauged by spectrophotometry . 60 specimens , subdivided into 6 groups were made : GI - Esthetic X Enamel ; GII - Esthetic X dentin ; GIII - Opallis Enamel ; GIV - Opallis dentin ; GV - Enamel and GVI Venus - Venus dentin . The specimens were prepared with a matrix to standardize samples . The inserts of incrementally resins and polymerized with a halogen light Ultralux unit ( Dabi Atlante , Brazil ) with a power of 450mW / cm ² . After fabrication , underwent color reading with a UV Visible Spectrophotometer reflection , UV -2450 ( Shimadzu , Kyoto , Japan ) , with the changes calculated by the system CIE L * a * b * . Then isolates were stored in artificial saliva at 35 ° C ± 2 ° C during 3 months containers being subjected to the effects of thermal cycling for 3000 cycles over the range of 5C to 55C . Again subjected to chromatic evaluation. For the analysis of the results of color change of the studied resins was applied ANOVA two factors at 5 % . The results showed a statistically equal resins enamel GI and GV ( p = 0.79 ) ; the same was not observed for GI and G III resins , where the color change was higher for resin G III ( p = 0.0000002 ) . The same was observed between G III and GV , where the resin enamel G III showed a statistically superior to the color change ( p = 0.0000005 ) Average . Resins to dentin was there a statistical equality between the materials studied . We conclude that the resins studied change in color and resin enamel G III was the most suffered major color changes after aging by thermocycling .
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Conselho Nacional de Desevolvimento Científico e Tecnológico (CNPq)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)