845 resultados para Device fabrication


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Electrodeposition from a lyotropic liquid crystal template medium was used to produce nanostructured platinum microelectrodes with high specific surface area and high mass transport efficiency. Compared to polished and conventional platinized microelectrodes, well-ordered nanostructured platinum microelectrodes exhibited enhanced electrocatalytic properties for oxygen and ascorbic acid, whilst well-ordered nanostructured platinum microelectrodes offered improved electrocatalytic properties for oxygen reduction compared to disordered nanostructured platinum microelectrodes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Self-assembly of monodisperse, silica-encapsulated, face-centered tetragonal FePt nanoparticles forms closely packed 2D arrays (see figure). Placing monodisperse FePt nanoparticles in silica nanocapsules allows the transition from a disordered face-centered cubic phase to a ferromagnetic crystalline face-centered tetragonal structure at elevated temperature without severe sintering. These materials are potential candidates for the generation of ultrahigh-density magnetic recording media.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This RTD project, 2007-2009, is partly funded by the European Commission, in Framework Programme 6. It aims to assist elderly people for living well, independently and at case. ENABLE will provide a number of services for elderly people based on the new technology provided by mobile phones. The project is developing a Wrist unit with both integrated and external sensors, and with a radio frequency link to a mobile phone. Dedicated ENABLE software running on the wrist unit and mobile phone makes these services fully accessible for the elderly users. This paper outlines the fundamental motivation and the approach which currently is undertaken in order to collect the more detailed user needs and requirements. The general architecture and the design of the ENABLE system are outlined.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cooled infrared filters have been used in pressure modulation and filter radiometry to measure the dynamics, temperature distribution and concentrations of atmospheric elements in various satellite radiometers. Invariably such instruments use precision infrared bandpass filters and coatings for spectral selction, often operating at cryogenic temperatures. More recent developments in the use of spectrally-selective cooled detectors in focal plane arrays have simplified the optical layout and reduced the component count of radiometers but have placed additional demands on both the spectral and physical performance requirements of the filters. This paper describes and contrasts the more traditional radiometers using discrete detectors with those which use focal plane detector array technology, with particular emphasis on the function of the filters and coatings in the two cases. Additionally we discuss the spectral techniques and materials used to fabricate infrared coatings and filters for use in space optics, and give examples of their application in the fabrication of some demanding long wavelength dichroics and filters. We also discuss the effects of the space environment on the stability and durability of high performance infrared filters and materials exposed to low Earth orbit for 69 months on the NASA Long Duration Exposure Facility (LDEF).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The fabrication and characterization of micromachined reduced-height air-filled rectangular waveguide components suitable for integration is reported in this paper. The lithographic technique used permits structures with heights of up to 100 μm to be successfully constructed in a repeatable manner. Waveguide S-parameter measurements at frequencies between 75-110 GHz using a vector network analyzer demonstrate low loss propagation in the TE10 mode reaching 0.2 dB per wavelength. Scanning electron microscope photographs of conventional and micromachined waveguides show that the fabrication technique can provide a superior surface finish than possible with commercially available components. In order to circumvent problems in efficiently coupling free-space propagating beams to the reduced-height G-band waveguides, as well as to characterize them using quasi-optical techniques, a novel integrated micromachined slotted horn antenna has been designed and fabricated, E-, H-, and D-plane far-field antenna pattern measurements at different frequencies using a quasi-optical setup show that the fabricated structures are optimized for 180-GHz operation with an E-plane half-power beamwidth of 32° elevated 35° above the substrate, a symmetrical H-plane pattern with a half-power beamwidth of 23° and a maximum D-plane cross-polar level of -33 dB. Far-field pattern simulations using HFSS show good agreement with experimental results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present a simple device for multiplex quantitative enzyme-linked immunosorbant assays (ELISA) made from a novel melt-extruded microcapillary film (MCF) containing a parallel array of 200µm capillaries along its length. To make ELISA devices different protein antigens or antibodies were immobilised inside individual microcapillaries within long reels of MCF extruded from fluorinated ethylene propylene (FEP). Short pieces of coated film were cut and interfaced with a pipette, allowing sequential uptake of samples and detection solutions into all capillaries from a reagent well. As well as being simple to produce, these FEP MCF devices have excellent light transmittance allowing direct optical interrogation of the capillaries for simple signal quantification. Proof of concept experiments demonstrate both quantitative and multiplex assays in FEP MCF devices using a standard direct ELISA procedure and read using a flatbed scanner. This new multiplex immunoassay platform should find applications ranging from lab detection to point-of-care and field diagnostics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper explores the nature of private social and environmental reporting (SER). From interviews with UK institutional investors, we show that both investors and investees employ Goffmanesque, staged impression management as a means of creating and disseminating a dual myth of social and environmental accountability. The interviewees’ utterances unveil private meetings imbued with theatrical verbal and physical impression management. Most of the time, the investors’ shared awareness of reality belongs to a Goffmanesque frame whereby they accept no intentionality, misrepresentation or fabrication, believing instead that the ‘performers’ (investees) are not intending to deceive them. A shared perception that social and environmental considerations are subordinated to financial issues renders private SER an empty encounter characterised as a relationship-building exercise with seldom any impact on investment decision-making. Investors spoke of occasional instances of fabrication but these were insufficient to break the frame of dual myth creation. They only identified a handful of instances where intentional misrepresentation had been significant enough to alter their reality and behaviour. Only in the most extreme cases of fabrication and lying did the staged meeting break frame and become a genuine occasion of accountability, where investors demanded greater transparency, further meetings and at the extreme, divested shares. We conclude that the frontstage, ritualistic impression management in private SER is inconsistent with backstage activities within financial institutions where private financial reporting is prioritised. The investors appeared to be in a double bind whereby they devoted resources to private SER but were simultaneously aware that these efforts may be at best subordinated, at worst ignored, rendering private SER a predominantly cosmetic, theatrical and empty exercise.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Older people increasingly want to remain living independently in their own homes. The aim of the ENABLE project is to develop a wearable device that can be used to support older people in their daily lives and which can monitor their health status, detect potential problems, provide activity reminders and offer communication and alarm services. In order to determine the specifications and functionality required for the development of the device, user surveys and focus groups were undertaken, use case analysis and scenario modeling carried out. The project has resulted in the development of a wrist-worn device and mobile phone combination that can support and assist older and vulnerable wearers with a range of activities and services both inside their home and as they move around their local environment. The device is currently undergoing pilot trials in five European countries. The aim of this paper is to describe the ENABLE device, its features and services, and the infrastructure within which it operates.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We are reporting on the fabrication and electrical characterization of a novel elastomer based micro-cuff neural interface. Electrodes are gold (Au) tracks of sub-100nm thickness and are thermally evaporated on a 0.5 mm thick polydimethylsiloxane (PDMS) substrate. We investigate how electrode area and immersion in phosphate buffered saline (PBS) at 37°C influence electrode impedance. A microfluidic channel is bonded to the electrode array to form the cuff. In an acute, in-vivo, proof-of-principle recording, the device is capable of detecting light stroking and pinch of a hind leg of an anaesthetized rat.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper explores the nature of private social and environmental reporting (SER). From interviews with UK institutional investors, we show that both investors and investees employ Goffmanesque, staged impression management as a means of creating and disseminating a dual myth of social and environmental accountability. The interviewees’ utterances unveil private meetings imbued with theatrical verbal and physical impression management. Most of the time, the investors’ shared awareness of reality belongs to a Goffmanesque frame whereby they accept no intentionality, misrepresentation or fabrication, believing instead that the ‘performers’ (investees) are not intending to deceive them. A shared perception that social and environmental considerations are subordinated to financial issues renders private SER an empty encounter characterised as a relationship-building exercise with seldom any impact on investment decision-making. Investors spoke of occasional instances of fabrication but these were insufficient to break the frame of dual myth creation. They only identified a handful of instances where intentional misrepresentation had been significant enough to alter their reality and behaviour. Only in the most extreme cases of fabrication and lying did the staged meeting break frame and become a genuine occasion of accountability, where investors demanded greater transparency, further meetings and at the extreme, divested shares. We conclude that the frontstage, ritualistic impression management in private SER is inconsistent with backstage activities within financial institutions where private financial reporting is prioritised. The investors appeared to be in a double bind whereby they devoted resources to private SER but were simultaneously aware that these efforts may be at best subordinated, at worst ignored, rendering private SER a predominantly cosmetic, theatrical and empty exercise.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A world of ubiquitous computing, full of networked mobile and embedded technologies, is approaching. The benefits of this technology are numerous, and act as the major driving force behind its development. These benefits are brought about, in part, by ubiquitous monitoring (UM): the continuous and wide spread collection of ?significant amounts of data about users

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background. Falls and fear of falling present a major risk to older people as both can affect their quality of life and independence. Mobile assistive technologies (AT) fall detection devices may maximise the potential for older people to live independently for as long as possible within their own homes by facilitating early detection of falls. Aims. To explore the experiences and perceptions of older people and their carers as to the potential of a mobile falls detection AT device. Methods. Nine focus groups with 47 participants including both older people with a range of health conditions and their carers. Interviews were audio recorded, transcribed verbatim, and thematically analysed. Results. Four key themes were identified relating to participants’ experiences and perceptions of falling and the potential impact of a mobile falls detector: cause of falling, falling as everyday vulnerability, the environmental context of falling, and regaining confidence and independence by having a mobile falls detector. Conclusion. The perceived benefits of a mobile falls detector may differ between older people and their carers. The experience of falling has to be taken into account when designing mobile assistive technology devices as these may influence perceptions of such devices and how older people utilise them.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background—A major problem in procurement of donor hearts is the limited time a donor heart remains viable. After cardiectomy, ischemic hypoxia is the main cause of donor heart degradation. The global myocardial ischemia causes a cascade of oxygen radical formation that cumulates in an elevation in hydrogen ions (decrease in pH), irreversible cellular injury, and potential microvascular changes in perfusion. Objective—To determine the changes of prolonged storage times on donor heart microvasculature and the effects of intermittent antegrade perfusion. Materials and Methods—Using porcine hearts flushed with a Ribosol-based cardioplegic solution, we examined how storage time affects microvascular myocardial perfusion by using contrast-enhanced magnetic resonance imaging at a mean (SD) of 6.1 (0.6) hours (n=13) or 15.6 (0.6) hours (n=11) after cardiectomy. Finally, to determine if administration of cardioplegic solution affects pH and microvascular perfusion, isolated hearts (group 1, n=9) given a single antegrade dose, were compared with hearts (group 2, n=8) given intermittent antegrade cardioplegia (150 mL, every 30 min, 150 mL/min) by a heart preservation device. Khuri pH probes in left and right ventricular tissue continuously measured hydrogen ion levels, and perfusion intensity on magnetic resonance images was plotted against time. Results—Myocardial perfusion measured via magnetic resonance imaging at 6.1 hours was significantly greater than at 15.6 hours (67% vs 30%, P= .00008). In group 1 hearts, the mean (SD) for pH at the end of 6 hours decreased to 6.2 (0.2). In group 2, hearts that received intermittent antegrade cardioplegia, pH at the end of 6 hours was higher at 6.7 (0.3) (P=.0005). Magnetic resonance imaging showed no significant differences between the 2 groups in contrast enhancement (group 1, 62%; group 2, 40%) or in the wet/dry weight ratio. Conclusion—Intermittent perfusion maintains a significantly higher myocardial pH than does a conventional single antegrade dose. This difference may translate into an improved quality of donor hearts procured for transplantation, allowing longer distance procurement, tissue matching, improved outcomes for transplant recipients, and ideally a decrease in transplant-related costs.