827 resultados para Decorative coatings
Resumo:
Given the multiplicity of nanoparticles (NPs), there is a requirement to develop screening strategies to evaluate their toxicity. Within the EU-funded FP7 NanoTEST project, a panel of medically relevant NPs has been used to develop alternative testing strategies of NPs used in medical diagnostics. As conventional toxicity tests cannot necessarily be directly applied to NPs in the same manner as for soluble chemicals and drugs, we determined the extent of interference of NPs with each assay process and components. In this study, we fully characterized the panel of NP suspensions used in this project (poly(lactic-co-glycolic acid)-polyethylene oxide [PLGA-PEO], TiO2, SiO2, and uncoated and oleic-acid coated Fe3O4) and showed that many NP characteristics (composition, size, coatings, and agglomeration) interfere with a range of in vitro cytotoxicity assays (WST-1, MTT, lactate dehydrogenase, neutral red, propidium iodide, (3)H-thymidine incorporation, and cell counting), pro-inflammatory response evaluation (ELISA for GM-CSF, IL-6, and IL-8), and oxidative stress detection (monoBromoBimane, dichlorofluorescein, and NO assays). Interferences were assay specific as well as NP specific. We propose how to integrate and avoid interference with testing systems as a first step of a screening strategy for biomedical NPs.
Resumo:
Chemoprevention is a pragmatic approach to reduce the risk of colorectal cancer, one of the leading causes of cancerrelated death in western countries. In this regard, maslinic acid (MA), a pentacyclic triterpene extracted from wax-like coatings of olives, is known to inhibit proliferation and induce apoptosis in colon cancer cell lines without affecting normal intestinal cells. The present study evaluated the chemopreventive efficacy and associated mechanisms of maslinic acid treatment on spontaneous intestinal tumorigenesis in ApcMin/+ mice. Twenty-two mice were randomized into 2 groups: control group and MA group, fed with a maslinic acid-supplemented diet for six weeks. MA treatment reduced total intestinal polyp formation by 45% (P,0.01). Putative molecular mechanisms associated with suppressing intestinal polyposis in ApcMin/+ mice were investigated by comparing microarray expression profiles of MA-treated and control mice and by analyzing the serum metabolic profile using NMR techniques. The different expression phenotype induced by MA suggested that it exerts its chemopreventive action mainly by inhibiting cell-survival signaling and inflammation. These changes eventually induce G1-phase cell cycle arrest and apoptosis. Moreover, the metabolic changes induced by MA treatment were associated with a protective profile against intestinal tumorigenesis. These results show the efficacy and underlying mechanisms of MA against intestinal tumor development in the ApcMin/+ mice model, suggesting its chemopreventive potential against colorectal cancer.
Resumo:
Chemoprevention is a pragmatic approach to reduce the risk of colorectal cancer, one of the leading causes of cancerrelated death in western countries. In this regard, maslinic acid (MA), a pentacyclic triterpene extracted from wax-like coatings of olives, is known to inhibit proliferation and induce apoptosis in colon cancer cell lines without affecting normal intestinal cells. The present study evaluated the chemopreventive efficacy and associated mechanisms of maslinic acid treatment on spontaneous intestinal tumorigenesis in ApcMin/+ mice. Twenty-two mice were randomized into 2 groups: control group and MA group, fed with a maslinic acid-supplemented diet for six weeks. MA treatment reduced total intestinal polyp formation by 45% (P,0.01). Putative molecular mechanisms associated with suppressing intestinal polyposis in ApcMin/+ mice were investigated by comparing microarray expression profiles of MA-treated and control mice and by analyzing the serum metabolic profile using NMR techniques. The different expression phenotype induced by MA suggested that it exerts its chemopreventive action mainly by inhibiting cell-survival signaling and inflammation. These changes eventually induce G1-phase cell cycle arrest and apoptosis. Moreover, the metabolic changes induced by MA treatment were associated with a protective profile against intestinal tumorigenesis. These results show the efficacy and underlying mechanisms of MA against intestinal tumor development in the ApcMin/+ mice model, suggesting its chemopreventive potential against colorectal cancer.
Resumo:
In traffic accidents involving motorcycles, paint traces can be transferred from the rider's helmet or smeared onto its surface. These traces are usually in the form of chips or smears and are frequently collected for comparison purposes. This research investigates the physical and chemical characteristics of the coatings found on motorcycles helmets. An evaluation of the similarities between helmet and automotive coating systems was also performed.Twenty-seven helmet coatings from 15 different brands and 22 models were considered. One sample per helmet was collected and observed using optical microscopy. FTIR spectroscopy was then used and seven replicate measurements per layer were carried out to study the variability of each coating system (intravariability). Principal Component Analysis (PCA) and Hierarchical Cluster Analysis (HCA) were also performed on the infrared spectra of the clearcoats and basecoats of the data set. The most common systems were composed of two or three layers, consistently involving a clearcoat and basecoat. The coating systems of helmets with composite shells systematically contained a minimum of three layers. FTIR spectroscopy results showed that acrylic urethane and alkyd urethane were the most frequent binders used for clearcoats and basecoats. A high proportion of the coatings were differentiated (more than 95%) based on microscopic examinations. The chemical and physical characteristics of the coatings allowed the differentiation of all but one pair of helmets of the same brand, model and color. Chemometrics (PCA and HCA) corroborated classification based on visual comparisons of the spectra and allowed the study of the whole data set at once (i.e., all spectra of the same layer). Thus, the intravariability of each helmet and its proximity to the others (intervariability) could be more readily assessed. It was also possible to determine the most discriminative chemical variables based on the study of the PCA loadings. Chemometrics could therefore be used as a complementary decision-making tool when many spectra and replicates have to be taken into account. Similarities between automotive and helmet coating systems were highlighted, in particular with regard to automotive coating systems on plastic substrates (microscopy and FTIR). However, the primer layer of helmet coatings was shown to differ from the automotive primer. If the paint trace contains this layer, the risk of misclassification (i.e., helmet versus vehicle) is reduced. Nevertheless, a paint examiner should pay close attention to these similarities when analyzing paint traces, especially regarding smears or paint chips presenting an incomplete layer system.
Resumo:
La obtención de recubrimientos con bajos coeficientes de fricción, es una innovadora respuesta a la creciente demanda industrial de alternativas para los tradicionales sistemas lubricados con aceites. Para este fin, la introducción de un sólido lubricante, en una matriz con buenas propiedades mecánicas, ha de conferir al conjunto un bajo coeficiente de fricción y mejorar la resistencia al desgaste del recubrimiento, favoreciendo además, la utilización a elevadas temperaturas, en las que los lubricantes líquidos convencionales presentan limitaciones. En el Centro de Proyección Térmica (CPT) de la Universidad de Barcelona se han obtenido mediante proyección de Plasma Atmosférico (APS) recubrimientos autolubricados de Ni-Grafito y Cr2O3-CaF2, estudiando con especial interés las propiedades y el efecto que produce el grafito y el CaF2 en las matrices metálica y cerámica respectivamente. Se ha determinado en los dos casos que el desgaste originado en los recubrimientos es bajo, si bien los coeficientes de fricción varían ostensiblemente en función del sistema indicado. Los resultados obtenidos indican que el recubrimiento de Ni-Grafito posee un comportamiento idóneo capaz de competir con los tradicionales lubricantes líquidos.
Resumo:
The improvement of the reliability of the contact between the osseous tissues and the implant materials has been tested by recovering the metallic implants with ceramic materials, usually calcium phosphates. In our study, the calcium phosphate recovering layers were deposited by means of a pulsed-laser deposition technique. Our aim was to to evaluate the tissue interactions established between cortical bone and titanium implants covered by five different layers, ranging from amorphous calcium phosphate to crystalline hydroxyapatite, obtained by altering the parameters of the laser ablation process. The surgical protocol of the study consisted in the simultaneous implantation of the five types of implants in both the tibial dyaphisis of three Beagle dogs, sacrificed respectively one, two and three months after the last surgical procedures. After the sacrifice, the samples were submitted to a scheduled procedure of embedding in plastic polymers without prior decalcification, in order to perform the ultrastructural studies: scanning microscopy with secondary and backscattered electrons (BS-SEM). Our observations show that both in terms of the calcified tissues appearing as a response to the presence of the different coatings and of time of recovering, the implants coated with crystalline calcium phosphate layers by laser ablation present a better result than the amorphous-calcium-phosphate-coated implants. Moreover, the constant presence of chondroid tissue, related with the mechanical induction by forces applied on the recovering area, strongly suggests that the mechanisms implied in osteointegration are related to endomembranous, rather than endochondral ossification processes
Resumo:
The improvement of the reliability of the contact between the osseous tissues and the implant materials has been tested by recovering the metallic implants with ceramic materials, usually calcium phosphates. In our study, the calcium phosphate recovering layers were deposited by means of a pulsed-laser deposition technique. Our aim was to to evaluate the tissue interactions established between cortical bone and titanium implants covered by five different layers, ranging from amorphous calcium phosphate to crystalline hydroxyapatite, obtained by altering the parameters of the laser ablation process. The surgical protocol of the study consisted in the simultaneous implantation of the five types of implants in both the tibial dyaphisis of three Beagle dogs, sacrificed respectively one, two and three months after the last surgical procedures. After the sacrifice, the samples were submitted to a scheduled procedure of embedding in plastic polymers without prior decalcification, in order to perform the ultrastructural studies: scanning microscopy with secondary and backscattered electrons (BS-SEM). Our observations show that both in terms of the calcified tissues appearing as a response to the presence of the different coatings and of time of recovering, the implants coated with crystalline calcium phosphate layers by laser ablation present a better result than the amorphous-calcium-phosphate-coated implants. Moreover, the constant presence of chondroid tissue, related with the mechanical induction by forces applied on the recovering area, strongly suggests that the mechanisms implied in osteointegration are related to endomembranous, rather than endochondral ossification processes
Resumo:
The improvement of the reliability of the contact between the osseous tissues and the implant materials has been tested by recovering the metallic implants with ceramic materials, usually calcium phosphates. In our study, the calcium phosphate recovering layers were deposited by means of a pulsed-laser deposition technique. Our aim was to to evaluate the tissue interactions established between cortical bone and titanium implants covered by five different layers, ranging from amorphous calcium phosphate to crystalline hydroxyapatite, obtained by altering the parameters of the laser ablation process. The surgical protocol of the study consisted in the simultaneous implantation of the five types of implants in both the tibial dyaphisis of three Beagle dogs, sacrificed respectively one, two and three months after the last surgical procedures. After the sacrifice, the samples were submitted to a scheduled procedure of embedding in plastic polymers without prior decalcification, in order to perform the ultrastructural studies: scanning microscopy with secondary and backscattered electrons (BS-SEM). Our observations show that both in terms of the calcified tissues appearing as a response to the presence of the different coatings and of time of recovering, the implants coated with crystalline calcium phosphate layers by laser ablation present a better result than the amorphous-calcium-phosphate-coated implants. Moreover, the constant presence of chondroid tissue, related with the mechanical induction by forces applied on the recovering area, strongly suggests that the mechanisms implied in osteointegration are related to endomembranous, rather than endochondral ossification processes
Resumo:
Polyuretaanielastomeerit ovat jaksottaisia sekapolymeerejä, jotka muodostuvat vuoroittaisista joustavien ketjujen segmenteistä ja hyvin polaarisista kovista segmenteistä. Kemiallinen rakenne ja ominaisuudet riippuvat käytetyistä reaktiokomponenteista. Pehmeän segmentin muodostaa polyoli ja kovan segmentin muodostaa yleensä di-isosyanaatti ja ketjunjatkaja. Polyuretaanielastomeerien valmistus tapahtuu valamalla, jolloin reaktiokomponentit ovat nestemäisiä. Työssä tutkittiin kahta perusmateriaalia ja yhden lisäaineen vaikutusta niiden ominaisuuksiin. Erityisesti kiinnitettiin huomiota dynaamisiin ja mekaanisiin ominaisuuksiin ja verrattiin aineita keskenään. Käytettyjä karakterisointimenetelmiä olivat kontaktikulmamittaukset, DMTA-mittaukset, dynaaminen rasittaminen pyörityslaitteella, elektronimikroskopia, hydrolyysitesti, vetotesti ja kulutustesti. Tutkittujen materiaalien pääasiallinen käyttökohde on pyörä- tai telapinnoitteena. Työn aikana kehitettiin pyörityslaite, jolla voitiin tutkia pinnoitemateriaalin käyttäytymistä halutuissa rasitusolosuhteissa. Lisäaineen vaikutus dynaamisiin ominaisuuksiin oli negatiivinen tai olematon, sillä DMTA-testien perusteella lisäaine kasvatti materiaalien häviötekijää (tan d). Pyöritystestien perusteella lisäaineella ei ollut vaikutusta hystereesiin eli pinnoitemateriaalin lämpenemiseen testin aikana. Uusi tutkittu materiaali osoittautui dynaamisissa kokeissa paremmaksi kuin vanha tuotantomateriaali. Lisäaine kasvatti molempien tutkittujen aineiden pintaenergiaa kontaktikulmamittausten perusteella. Tuotantoaineen vetomurtolujuus kasvoi lisäaineen vaikutuksesta, mutta uuden aineen vetomurtolujuus pieneni. Lisäaineella oli lievä hydrolyysiltä suojaava vaikutus tutkituilla perusaineilla. Uusi tutkittu perusmateriaali sieti hydrolyysiä paremmin kuin tuotantomateriaali, koska sen valmistuksessa käytettiin polyeetteripolyolia ja tuotantomateriaalissa polyesteripolyolia.
Resumo:
Lämpökameroiden kehitys on mahdollistanut lämpökameroiden käytön myös erittäin pienien kohteiden tarkastelussa. Luotettava absoluuttisten lämpötilojen selvittäminen lämpökameralla vaatii, että tarkasteltavan kohteen emissiivisyys on kauttaaltaan vakio ja tunnettu. Käytännössä erilaisten materiaalipintojen emissiivisyyksissä on merkittäviä eroja, mikä aiheuttaa virheitä mittaustuloksiin. Tutkimuksen tavoitteena oli löytää halpa ja käytännöllinen keino piirilevyn emissiivisyyden vakiointiin. Työssä kartoitettiin erilaisia pinnoitteita, joille tehtiin resistanssi-, impedanssi- sekä lämpökameramittaukset. Mittauksilla selvitettiin pinnoitteen soveltuvuus emissiivisyyden vakiointiin. Lisäksi tutustuttiin pintapuolisesti pinnoiteaineiden kemialliseen rakenteeseen, jotta saatiin peruskäsitys siitä, onko aineiden kemiallisella rakenteella merkitystä pinnoiteaineen emissiivisyyden vakiointikykyyn. Tutkimustulosten perusteella tutkituista pinnoitteista parhaaksi todettiin talkkijauhe. Talkkipinnoitteella saatiin luotettavia mittaustuloksia. Tällä hetkellä pinnoitemenetelmää voidaan käyttää yksittäisten piirilevyjen testauksessa laboratorio-olosuhteissa. Tulevaisuudessa menetelmää voitaisiin soveltaa myös piirilevyjen tuotantolinjalle.
Resumo:
El trabajo consta de un completo estudio tribológico del sistema WX que consiste en la mezcla mecánica de WC-12Co y NiCrBSi en diferentes proporciones: 20% NiCrBSi (W2), 40% NiCrBSi (W4) y 60% NiCrBSi (W6). Los recubrimientos se han obtenido por proyección térmica de alta velocidad (HVOF). Para todos los sistemas, el coeficiente de fricción es menor que 0.5 y la energía intercambiada entre el par friccionante y el recubrimiento es inferior a 10 KJ. Para cuantificar el desgaste por fricción se han utilizado la profundidad de la huella y el volumen perdido durante el ensayo, obtenidos mediante Interferometría de Barrido de Luz Blanca (SLWI) y SEM. La profundidad de la huella sigue una evolución directamente proporcional al contenido en NiCrBSi. Un mayor contenido en WC-12Co aumenta la resistencia al desgaste por fricción y disminuye la velocidad de desgaste por abrasión (ensayo Rubber Wheel). En los recubrimientos obtenidos, no se observa difusión entre las fases, la adherencia con el sustrato es excelente, la porosidad menor al 2% y se produce un incremento de la dureza del recubrimiento debido al endurecimiento por trabajo de la matriz causada por impacto.
Resumo:
Las barreras térmicas poseen unas propiedades mecánicas y tribológicas limitadas. Los tratamientos térmicos de sintetizado pueden utilizarse como una posible solución para su mejora. En el presente trabajo se evalúa la evolución de diversas propiedades tribológicas y mecánicas, a diferentes tiempos de sinterización, a temperatura de 1.000 °C. Se observa que el sintetizado produce un aumento de la resistencia al desgaste, de la dureza y del módulo de Young. A partir de los ensayos ball-on-disk, realizados utilizando un par friccionante de ZrO2 y de acero, se han estudiado los mecanismos de desgaste dominantes para cada uno de los pares friccionantes. Se ha observado que la delaminación entre partículas y la fractura frágil durante el proceso de desgaste son los mecanismos principales que controlan el proceso. Los caminos de desgaste estudiados mediante microscopía electrónica de barrido (SEM) e interferometría de barrido de luz blanca (SWLI) han permitido cuantificar el desgaste en cada uno de los casos. A fin de poder estudiar los recubrimientos de ZrO2 mediante SEM y SWLI ha sido necesario realizar una metalización con oro para así aumentar la conductividad eléctrica y reflectividad de las muestras.
Resumo:
BACKGROUND: Recently, it has been suggested that the type of stent used in primary percutaneous coronary interventions (pPCI) might impact upon the outcomes of patients with acute myocardial infarction (AMI). Indeed, drug-eluting stents (DES) reduce neointimal hyperplasia compared to bare-metal stents (BMS). Moreover, the later generation DES, due to its biocompatible polymer coatings and stent design, allows for greater deliverability, improved endothelial healing and therefore less restenosis and thrombus generation. However, data on the safety and performance of DES in large cohorts of AMI is still limited. AIM: To compare the early outcome of DES vs. BMS in AMI patients. METHODS: This was a prospective, multicentre analysis containing patients from 64 hospitals in Switzerland with AMI undergoing pPCI between 2005 and 2013. The primary endpoint was in-hospital all-cause death, whereas the secondary endpoint included a composite measure of major adverse cardiac and cerebrovascular events (MACCE) of death, reinfarction, and cerebrovascular event. RESULTS: Of 20,464 patients with a primary diagnosis of AMI and enrolled to the AMIS Plus registry, 15,026 were referred for pPCI and 13,442 received stent implantation. 10,094 patients were implanted with DES and 2,260 with BMS. The overall in-hospital mortality was significantly lower in patients with DES compared to those with BMS implantation (2.6% vs. 7.1%,p < 0.001). The overall in-hospital MACCE after DES was similarly lower compared to BMS (3.5% vs. 7.6%, p < 0.001). After adjusting for all confounding covariables, DES remained an independent predictor for lower in-hospital mortality (OR 0.51,95% CI 0.40-0.67, p < 0.001). Since groups differed as regards to baseline characteristics and pharmacological treatment, we performed a propensity score matching (PSM) to limit potential biases. Even after the PSM, DES implantation remained independently associated with a reduced risk of in-hospital mortality (adjusted OR 0.54, 95% CI 0.39-0.76, p < 0.001). CONCLUSIONS: In unselected patients from a nationwide, real-world cohort, we found DES, compared to BMS, was associated with lower in-hospital mortality and MACCE. The identification of optimal treatment strategies of patients with AMI needs further randomised evaluation; however, our findings suggest a potential benefit with DES.
Resumo:
The ancient temple dedicated to the Roman Emperor Augustus on the hilltop of Tarraco (today’s Tarragona), was the main element of the sacred precinct of the Imperial cult. It was a two hectare square, bordered by a portico with an attic decorated with a sequence of clypeus (i.e. monumental shields) made with marble plates from the Luni-Carrara’s quarries. This contribution presents the results of the analysis of a three-dimensional photogrammetric survey of one of these clipeus, partially restored and exhibited at the National Archaeological Museum of Tarragona. The perimeter ring was bounded by a sequence of meanders inscribed in a polygon of 11 sides, a hendecagon. Moreover, a closer geometric analysis suggests that the relationship between the outer meander rim and the oval pearl ring that delimited the divinity of Jupiter Ammon can be accurately determined by the diagonals of an octagon inscribed in the perimeter of the clypeus. This double evidence suggests a combined layout, in the same design, of an octagon and a hendecagon. Hypothetically, this could be achieved by combining the octagon with the approximation to Pi used in antiquity: 22/7 of the circle’s diameter. This method allows the drawing of a hendecagon with a clearly higher precision than with other ancient methods. Even the modelling of the motifs that separate the different decorative stripes corroborates the geometric scheme that we propose.
Resumo:
Different types of aerosolization and deagglomeration testing systems exist for studying the properties of nanomaterial powders and their aerosols. However, results are dependent on the specific methods used. In order to have well-characterized aerosols, we require a better understanding of how system parameters and testing conditions influence the properties of the aerosols generated. In the present study, four experimental setups delivering different aerosolization energies were used to test the resultant aerosols of two distinct nanomaterials (hydrophobic and hydrophilic TiO2). The reproducibility of results within each system was good. However, the number concentrations and size distributions of the aerosols created varied across the four systems; for number concentrations, e.g., from 10(3) to 10(6) #/cm(3). Moreover, distinct differences were also observed between the two materials with different surface coatings. The article discusses how system characteristics and other pertinent conditions modify the test results. We propose using air velocity as a suitable proxy for estimating energy input levels in aerosolization systems. The information derived from this work will be especially useful for establishing standard operating procedures for testing nanopowders, as well as for estimating their release rates under different energy input conditions, which is relevant for occupational exposure.