914 resultados para Cosmetic filler


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The polyethylene terephthalate (PET) is used for package drugs and cosmetics. The aim of this research was examine by scanning electron microscopy (SEM) a Staphylococcus aureus attachment and biofilm formation on a polyethylene terephthalate (PET) surface and hydrophobicity of S. aureus by adherence to hydrocarbons. A suspension of S. aureus was prepared in Mueller-Hinton broth and, coupons of polyethylene terephthalate were incubated for 30 minutes, two, 24 and 48 hours, 15 and 30 days. Afteron the coupons were removed and prepared for scanning electron microscope analysis. The attachment and biofilm formation was observed on the surfaces of PET. The SEM revealed adhesion and biofilm formation on PET surfaces. The hydrophobicity test classified S. aureus as hydrophobic.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

With the exception of the cleft lip, developmental defects (DD) of the lip are rare. The upper lip originates from the ectomesenchyme and is formed by the merging of the nasal medial and lateral processes with the maxillary process. Disturbances during this formation period can cause DD with functional and/or esthetic repercussions. We present a case of DD of the upper lip in a patient with a history of progressive growth of the left lateral portion of the upper lip that occurred from the time of birth until the age of 22 years. Clinical examination revealed hypertrophy of the area from the left philtral columns to the left commissure of the lip, extending the portion of the surface mucosa creating a flaccid and asymptomatic tissue mass. All other buccal structures appeared to be within normal limits and without any evidence of defects or deformities. In the surgical planning we decided to carry out corrective surgery in two phases. The first phase accomplished a conservative excision of the total abnormal labial tissue mass with a CO2 laser radiation (5 W in continuous mode, bunch diameter φ = 0.6 mm with a power density of 768 W/cm2 and fluency of 0.231 J/cm2) being careful to preserve the vermilion portion of the lip. Postsurgical clinical evaluations were done every three days until the skin sutures were removed and then every seven days until two months post surgery. While the entire mass of excessive tissue could not be completely removed, the removal of the excessive mucosal tissue produced a very good outcome relative to lip function, with a good esthetic result without scarring, and good tissue mobility. The results showed that the CO2 laser is an extremely useful instrument that can provide excellent control of the surgical field and allow for healing that produces excellent functional and esthetic results. © 2005 Taylor & Francis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An integrated and interdisciplinary research programme with native medicinal plants from tropical forests has been performed in order to obtain new forest products for sustainable use in regional markets vis-à-vis ecosystem conservation. For the success of this programme ethnopharmacological studies are very important with respect to (i) identification of useful plants including medicinal and aromatic species; (ii) recuperation and preservation of traditional knowledge about native plants; and (iii) identification of potential plants with economic value. The plants are selected with a view to evaluate efficacy and safety (pharmacological and toxicological studies), and phytochemical profile and quality control (phytochemical and chromatographic characterization). These studies are very important to add value to plant products and also to mitigate unscrupulous exploitation of medicinal plants by local communities, since multiple use of plants represents an excellent strategy for sustaining the tropical ecosystem through ex situ and in situ conservation. Thus, conservation of tropical resources is possible in conjunction with improvements in the quality of life of the traditional communities and production of new products with therapeutic, cosmetic and 'cosmeceutic' value. © NIAB 2005.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A new method for high-resolution analyses of hair surface charge density under ambient conditions is presented in this paper. Electrostatic force microscopy (EFM) is used here to analyze changes in surface charge density in virgin hair, bleached hair, and hair treated with a cationic polymer. The atomic force microscopy technique is used concomitantly to analyze morphological changes in hair roughness and thickness. The EFM images depict exactly how the polymer is distributed on the surface of the hair fiber. The EFM's powerful analytical tools enabled us to evaluate the varying degrees of interaction between the hair fiber surface charge density and the cationic polymer. The surface charge density and the polymer's distribution in the hair fibers are presented in the light of EFM measurements. © 2006 Society of Cosmetic Scientists and the Socièété Française de Cosmétologie.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This research studies the influence of the pozzolanic activity of the calcareous and basalt in the resistence behavior of the compressive strength of high performance self-compacting concrete (HPSCC). The selected aditives are the calcareous filler and basalt filler, for they are industrial residues helping that way the sustainable development. The paste of this concrete type is constituted of cement, silica fume, calcareous filler or basalt filler, water and superplasticizer additive. In this research the relationships water/cement are fixed in 0,40 kg/kg, silica fume/cement of 0,10 kg/kg and the relationships filler/cement and superplasticizer/cement are determined through of Marsh́s cone and mini-slump tests. The granular skeleton is gotten from a composition between quartzous sand and brita of basalt that presents the lesser index of emptinesses. The results show that the HPSCC with the addition of calcareous filler has greater compressive strength than what the HPSCC with addition of basalt filler in the ages of 7, 28 and 63 days. It is explained by the fact that the calcareous filler presents greater index of pozzolanic activity than the basalt filler. Besides that the relation water/fine for the HPSCC with calcareous filler is 0,27 l/kg whereas the HPSCC with basalt filler is of 0,29 l/kg.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study is to compare polyurethanes containing castor oil (soft segment) in granular form compared to cancellous bone autograft applied to a segmental bone defect. Norfolk adult female rabbits - approximately 13 months of age with a mean body weight of 4.5 kg - are used. In both radial diaphyses, 1 cm osteoperiosteal segmental defects are created. The defect in the left radius is filled with the castor-oil-based polyurethane, and the right one, filled with cancellous bone autograft, collected from the left proximal humerus. The rabbits are euthanazed at 15, 30, 60, and 120 days postsurgery (5 animals/ period), for histological analyses. By radiographic analyses, at these time points, the bone regeneration is more evident and accelerated in the bone defects treated with the cancellous bone autograft. At 120 days postsurgery, the segmental bone defects treated with the cancellous bone autograft are totally reconstituted and remodeled, while the bone defects treated with polyurethane polymer have bone formation of 79%. Histological study shows that the polyurethane acts as a space filler, minimizing the local production of fibrous tissue. No granule degradation, resorption or any inflammatory reaction is detected. Thus, it is possible to conclude that the castor-oil-plant-based polyurethane - in the granule presentation - is biocompatible and osteointegrated, but does not show the same bone regeneration capacity as the cancellous bone autograft. © 2007 SAGE Publications.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Although not desirable, cosmetic products can cause some adverse effects in me user. Such effects can be due bom to individual factors and by inadequate use. So, the safety evaluation must precede the placement of the cosmetic product in the market. Once the consumer has free access to cosmetic product, it must be safe in normal conditions or reasonably previsible of use. Historically the evaluation tests were accomplished with animals (in vivo) but, at the moment, some research centers have been adopting new alternatives (in vitro) in order to replace me tests with animals. This article emphasizes me necessity of accomplishing toxicity assays for personal hygiene products, cosmetics and perfumes, an also presents the tests in vivo and in vitro used, approaching the necessity of alternative methods to the assays in vitro in the evaluation of security of them.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Some hypotheses and constants studies are made with intention to elucidate the aging process. To prevent and to attenuate the cutaneous aging it becomes necessary to strengthen our endogenous antioxidant natural defenses. Diverse exogenous antioxidant substances, as vitamins, vegetal extracts and others, have been used by the Cosmetology in antiaging products. The objective of this paper is to show how the Molecular Modeling can be an useful tool in the research for new antioxidant cosmetic substances to face the cutaneous aging.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This is a case report of a patient with Down's syndrome with an important mechanical ectropion and elongation of the lower lid related to chronic allergic conjunctivitis, besides cataract and keratoconus. The tarsal strip technique and ressection of redundant and thick conjunctiva was the surgical approach chosen for this case. Functional and cosmetic outcomes were considered satisfactory.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A Streptomyces was isolated from poultry plant wastewater, showed high keratinolytic activity when cultured on feather meal medium. Optimum keratinolytic activity was observed at 40°C and pH 8.0. The enzyme also showed to be stable between 40 and 60°C. The keratinolytic activity was not inhibited by EDTA, DMSO and Tween 80. On the other hand, CaCl2, ZnCl2, and BaCl2 slightly inhibited the keratinolytic activity. The Streptomyces isolated might be useful in leather, keratin waste treatment, animal feeding industry, and also cosmetic industry. © 2008 Academic Journals.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To evaluate the histological and systemic response to subcutaneous injection of polyethylene gel in rats. Methods: Twenty-one white male rats were divided into 3 groups (G): G1 and G2 received subcutaneous polyethylene gel injection in the dorsal midline and were sacrificed at 30 and 60 postoperative days, respectively. G3 was not exposed to the polyethylene gel and was sacrificed after 60 days. Blood levels of lactate dehydrogenase (LDH), creatine kinase (CK), and alkaline phosphatase (ALP) were evaluated. The heart, kidney, liver, adrenal gland, injection site, and adjacent tissues were histologically examined. The results were submitted to statistical analysis. Results: There was no clinical evidence of extrusion, reduction of the injected volume, or abnormalities in the adjacent tissues. Blood levels of CK and LDH were normal and similar in all groups. ALP levels were significantly lower in G2 than in G1 and G3. The systemic organs were normal on histological examination in the 3 groups evaluated. Microscopically, the polyethylene gel was surrounded by a thin pseudocapsule formation and minimal inflammatory cell response, which decreased from G1 to G2. Conclusion: The subcutaneous injection of polyethylene gel in rats elicited minimal local inflammatory response and no systemic side effects. Copyright © 2008 Informa Healthcare USA, Inc.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The growing demand for stable, safe and effective cosmetics has required increasingly complex studies by the scientific community and the use of more efficient techniques to determine the stability of these products. The use of active principles from the Brazilian flora has led to the development of numerous products, in the most varied pharmaceutical forms, making it, even more difficult to standardize experimental protocols to certify the stability of cosmetic preparations. While in Brazil there is no one protocol that standardizes the tests that should be carried out to determine product stability, several studies have been conducted in academic laboratories to determine the stability of specific raw materials. The rheological properties of topical use products have to be taken into account in their manufacture, storage and application. The determination of the rheological behavior of a formulation helps in evaluating the physicochemical nature of the vehicle, allowing early signs of physical instability to be detected and thus enabling quality control of the constituents, test formulations and final products. Thermal analysis has also been used to assist in the study of cosmetic stability and differential scanning calorimetry to guide the development of new products. Other tools, such as fluorimetry and laser granulometry can be used to help the study and development of both emulsified and non-emulsified systems. The aim of the present study is to develop a protocol for the investigation of the physical and chemical stability of phytocosmetics - systems containing active compounds extracted from the Brazilian biodiversity.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Despite efforts to the contrary, some cosmetic products can cause undesirable side effects in the users. These may often be due to individual factors or inappropriate use of the product. Thus, biological assays to assess the safety of a new cosmetic must precede its being placed on the market. Historically, these tests have always been carried out in vivo, in animals, since such tests can be used to evaluate many of the potential risks, such as irritation, allergy or systemic effects; but, recently, some research centers have been adopting in vitro alternatives, in order to replace the animal tests. This review emphasizes the need to employ biological assays to test the safety of cosmetic products, and reviews the main in vivo and in vitro tests used, focusing on the need to develop and use alternatives to the in vivo assays of product safety, so as to offer the consumers the maximum safety with the least possible risk, while ensuring the best conditions of use of the product.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The indirect adhesive procedures constitute recently a substantial portion of contemporary esthetic restorative treatments. The resin cements have been used to bond tooth substrate and restorative materials. Due to recently introduction of the self-bonding resin luting cement based on a new monomer, filler and initiation technology has become important to study the degree of conversion of these new materials. In the present work the polymerization reaction and the filler content of dual-cured dental resin cements were studied by means of infra-red spectroscopy (FT-IR) and thermogravimetry (TG). Twenty specimens were made in a metallic mold (8 mm diameter × 1 mm thick) from each of 2 cements, Panavia® F2.0 (Kuraray) and RelyX™ Unicem Applicap (3M/ESPE). Each specimen was cured with blue LED with power density of 500 mW/cm 2 for 30 s. Immediately after curing, 24 and 48 h, and 7 days DC was determined. For each time interval 5 specimens were pulverized, pressed with KBr and analyzed with FT-IR. The TG measurements were performed in Netzsch TG 209 under oxygen atmosphere and heating rate of 10°C/min from 25 to 700°C. A two-way ANOVA showed DC (%) mean values statistically significance differences between two cements (p < 0.05). The Tukey's test showed no significant difference only for the 24 and 48 h after light irradiation for both resin cements (p > 0.05). The Relx-Y™ Unicem mean values were significantly higher than Panavia® F 2.0. The degree of conversion means values increasing with the storage time and the filler content showed similar for both resin cements. © 2009 Pleiades Publishing, Ltd.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this study was to evaluate the transmittance of seven different composite resins. Ten specimens were prepared (10 mm diameter, 2 mm thickness) for each experimental group, as follows: G1- Charisma® A 2 (Heraeus-Kulzer); G2- Filtek™ Supreme A 2E (3M/ESPE); G3- Filtek™ Supreme A2B (3M/ESPE); G4-Filtek™ Supreme YT (3M/ESPE); G5- Esthet-X® A2 (Dentsply); G6- Esthet-X® YE (Dentsply); G7- Durafill® A 2 (Heraeus-Kulzer) and G8- Filtek™ Z-100 A2 (3M/ESPE). The transmittance mode was measured using a UV-visible spectrophotometer (Cary Instruments) at 400-760 nm. The specimens were evaluated at three different times: zero hour (initial), 24 hours and 10 days after immersion in artificial saliva. The differences in transmittance were determined by two-way analysis of variance (ANOVA) and Tukey's test. The various composite resins showed significant differences in the wavelength dependence of transmittance. The mean values of transmittance increased significantly, with wavelengths increasing from 400 to 760 nm. The performance of the experimental groups was similar in terms of immersion time, considering that at time zero and after 10 days, all the groups showed similar results, which were statistically higher than the values obtained after 24 hours of immersion. The Filtek™ Supreme YT composite resin presented the highest mean transmittance values along the wavelengths at the three measured times. Esthet-X® YE and Durafill® yielded similar mean transmittance values, which were higher than those of the other groups. This study shows that the transmittance values of composite resins are directly related with the type, size and amount of inorganic filler particles.