994 resultados para Conventional coronary stent


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction Trypanosoma cruzi, a flagellated protozoan, is the etiologic agent of Chagas disease, and it is estimated that approximately 5 million people in Brazil are infected with this parasite. This work aimed to compare the current diagnostic methods for Chagas disease, including conventional serological (IFAT and ELISA) and molecular techniques (PCR), to introduce PCR as an auxiliary technique. Methods A total of 106 chagasic patients were evaluated: 88 from endemic areas of Parana, 6 from São Paulo, 3 from Minas Gerais, 3 from Rio Grande do Sul, 1 from Bahia and 5 from the Santa Catarina T. cruzi outbreak. The samples were analyzed by conventional serological methods (IFAT, ELISA), hemoculture and PCR to confirm Chagas disease. Results When IFAT was used to determine antibody levels, the sensitivity was 81.7% for patients with the cardiac form of the disease and 100% for the other clinical forms. In contrast, ELISA showed 84% sensitivity and 100% specificity. The use of serological and molecular techniques and their implications for the diagnosis of Chagas disease in non-endemics area are discussed. Conclusions PCR constitutes an excellent support methodology for the laboratory diagnosis of Chagas disease due to its high sensitivity and specificity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

There is ample experimental and clinical evidence of functional and structural microvascular abnormalities occurring in patients with Chagas cardiomyopathy, possibly due to the inflammatory process and/or autonomic disturbances caused by Trypanosoma cruzi infection. Those microvascular derangements are likely to constitute at least an ancillary factor that potentiates and amplifies the chronic inflammation in myocardial tissue. It is possible to devise appropriate therapeutic interventions aimed at reverting or slowing the progression of the microvascular abnormalities to positively affect the natural history of Chagas cardiomyopathy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Urinary symptoms occur in 19% of human T-cell lymphotropic virus type 1 (HTLV-1)-infected patients who do not fulfill criteria for HTLV-1-associated myelopathy/tropical spastic paraparesis (HAM/TSP) and in almost 100% of HAM/TSP patients. Few studies have evaluated therapies for overactive bladder (OAB) caused by HTLV-1 infection. This case report describes the effect of onabotulinum toxin A on the urinary manifestations of three patients with HAM/TSP and OAB symptoms. The patients were intravesically administered 200 units of Botox®. Their incontinence episodes improved, and their OAB symptoms scores (OABSS) reduced significantly. These data indicate that Botox® should be a treatment option for OAB associated with HTLV-1 infection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: The aims of this study were to evaluate the safety and efficacy of laparoscopic abdominoperineal resection compared to conventional approach for surgical treatment of patients with distal rectal cancer presenting with incomplete response after chemoradiation. METHOD: Twenty eight patients with distal rectal adenocarcinoma were randomized to undergo surgical treatment by laparoscopic abdominoperineal resection or conventional approach and evaluated prospectively. Thirteen underwent laparoscopic abdominoperineal resection and 15 conventional approach. RESULTS: There was no significant difference (p<0,05) between the two studied groups regarding: gender, age, body mass index, patients with previous abdominal surgeries, intra and post operative complications, need for blood transfusion, hospital stay after surgery, length of resected segment and pathological staging. Mean operation time was 228 minutes for the laparoscopic abdominoperineal resection versus 284 minutes for the conventional approach (p=0.04). Mean anesthesia duration was shorter (p=0.03) for laparoscopic abdominoperineal resection when compared to conventional approach : 304 and 362 minutes, respectively. There was no need for conversion to open approach in this series. After a mean follow-up of 47.2 months and with the exclusion of two patients in the conventional abdominoperineal resection who presented with unsuspected synchronic metastasis during surgery, local recurrence was observed in two patients in the conventional group and in none in the laparoscopic group. CONCLUSIONS: We conclude that laparoscopic abdominoperineal resection is feasible, similar to conventional approach concerning surgery duration, intra operative morbidity, blood requirements and post operative morbidity. Larger number of cases and an extended follow-up are required to adequate evaluation of oncological results for patients undergoing laparoscopic abdominoperineal resection after chemoradiation for radical treatment of distal rectal cancer.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Left ventricular hypertrophy following volume overload is regarded as an example of cardiac remodeling without increased fibrosis accumulation. However, infarction is associated with increased fibrosis within the noninfarcted, hypertrophied myocardium, particularly in the subendocardial regions. It is conceivable to suppose that, as also occurs postinfarction, low coronary driving pressure may also interfere with accumulation of myocardial fibrosis following aortocaval fistula. PURPOSE: To investigate the role of acute hemodynamic changes in subsequent deposition of cardiac fibrosis in response to aortocaval fistula. METHOD: Aortocaval fistula were created in 4 groups of Wistar rats that were followed over 4 and 8 weeks: aortocaval fistula 4 and aortocaval fistula 8 (10 rats each) and their respective controls (sham-operated controls - Sh), Sh4 and Sh8 (8 rats each). Hemodynamic measurements were performed 1 week after surgery. Hypertrophy and fibrosis were quantified by myocyte diameter and collagen volume fraction at the end of follow up. RESULT: Compared with Sh4 and Sh8, pulse pressure, left ventricular end-diastolic pressure, and +dP/dt were higher in aortocaval fistula 4 and aortocaval fistula 8, but -dP/dt was similar. Coronary driving pressure (mm Hg), used as an estimate of perfusion pressure, was lower in aortocaval fistula 8 (52.6 ± 4.1) than in Sh8 (100.8 ± 1.3), but comparable between aortocaval fistula 4 (50.0 ± 8.9) and Sh4 (84.8 ± 2.3). Myocyte diameter was greater in aortocaval fistula 8, whereas interstitial and subendocardial fibrosis were greater in aortocaval fistula 4 and aortocaval fistula 8. Coronary driving pressure correlated inversely and independently with subendocardial fibrosis (r² = .86, P <.001), whereas left ventricular systolic pressure (r² = 0.73, P = .004) and end-diastolic pressure (r² = 0.55, P = 012) correlated positively and independently with interstitial fibrosis. CONCLUSION: Coronary driving pressure falls and ventricular pressures increase early after aortocaval fistula and are associated with subsequent myocardial fibrosis deposition.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

RESUMO: Introdução - A utilização de células e das suas propriedades para o tratamento das doenças cardiovasculares, é uma promessa para o futuro e talvez a única forma de ultrapassar algumas das insuficiências das terapêuticas atuais. A via de entrega das células mais utilizada na investigação tem sido a intracoronária, ganhando a microcirculação especial relevância, por ser onde ocorre a primeira interação com o tecido nativo. As células estaminais mesenquimais (CEM) têm propriedades que as tornam particularmente aptas para a Terapia Celular, mas as suas dimensões, superiores ao diâmetro dos capilares, tem motivado controvérsia quanto à sua entrega intracoronária. A cardiologia de intervenção tem atualmente técnicas que permitem a avaliação em tempo real e in vivo do estado da microcirculação coronária. A determinação do índice da resistência da microcirculação (IRM) fornece informação sobre a circulação dos pequenos vasos, de forma independente da circulação coronária e do estado hemodinâmico, mas a aplicabilidade clínica deste conhecimento encontra-se ainda por definir. Objectivos Esclarecer o potencial do IRM no estudo dos efeitos do transplante de CEM por via intracoronária. População e Métodos . Estudo pré-clínico com modelo animal (suíno) desenvolvido em 3 fases. Na Primeira Fase foram utilizados 8 animais saudáveis para estudar e validar a técnica de determinação de estudo da microcirculação. Efetuou-se a determinação do IRM com duas doses diferentes de papaverina para a indução da resposta hiperémica máxima (5 e 10 mg) e após a disfunção da microcirculação com injeção intracoronária de microesferas de embozene com 40 μm de diâmetro. Na Segunda Fase foram utilizados 18 animais saudáveis, randomizados em grupo controlo e grupo recetor de 30 x 106 CEM por via intracoronária. Foram avaliados de forma cega o IRM, a pressão aórtica, o fluxo coronário epicárdico e a ocorrência de alterações electrocardiográficas. Na Terceira Fase foram utilizados 18 animais, com enfarte agudo do miocárdio provocado (EAM), randomizados em grupo controlo, grupo recetor de CEM expandidas de forma convencional e grupo recetor de CEM expandidas com metodologia inovadora e de menores dimensões. Foi realizada uma exploração da dose/efeito com infusão faseada de 10 x 106, 15 x 106 e 20 x 106 CEM, com determinação do IRM, da pressão aórtica, do fluxo coronário epicárdico e da ocorrência de alterações eletrocardiográficas. Quatro semanas após a entrega das células foi novamente avaliado o IRM e foi efetuado o estudo anatomopatológico dos animais na procura de evidência de neoangiogénese e de regeneração miocárdica, ou de um efeito positivo da resposta reparadora após o enfarte. Resultados Nas 3 fases todos os animais mantiveram estabilidade hemodinâmica e eletrocardiográfica, com exceção da elevação de ST de V1-V3 verificada após a injeção das microesferas. Na Primeira Fase as duas doses de papaverina induziram uma resposta hiperémica eficaz, sem tradução com significado na determinação do IRM (variação da pressão distal de - 11,4 ± 5 e de - 10,6± 5 mmHg com as doses de 5 e 10 mg respetivamente (p=0,5). Com a injeção das microesferas o IRM teve uma elevação média de 310 ± 190 %, para um valor médio de 41,3 ± 16 U (p = 0,001). Na Segunda Fase não houve diferenças significativas dos parâmetros hemodinâmicos, do fluxo epicárdico e da avaliação eletrocardiográfica entre os dois grupos. O IRM de base foi semelhante e após a infusão intracoronária observou-se uma elevação expressiva do IRM nos animais que receberam células em comparação com o grupo controlo (8,8 U ± 1 vs. 14,2 U ± 1,8, P=0,02) e quanto ao seu valor de base (aumento de 112%, p=0,008). Na terceira Fase não houve novamente diferenças significativas dos parâmetros hemodinâmicos, do fluxo epicárdico e da avaliação eletrocardiográfica entre os três grupos. Houve uma elevação do IRM nos animais que receberam células a partir da 2ª dose (72% nas células convencionai e 108% nas células inovadoras) e que se manteve com a 3ª dose (100% nas células convencionais e 88% nas inovadoras) com significado estatístico em comparação com o grupo controlo (p=0,034 com a 2ªdose e p=0,024 com a 3ª dose). Quatro semanas após a entrega das CEM observou-se a descida do IRM nos dois grupos que receberam células, para valores sobreponíveis aos do grupo controlo e aos valores pós-EAM. Na avaliação anatomopatológica e histológica dos corações explantados não houve diferenças entre os três grupos. Conclusões O IRM permite distinguir alterações da microcirculação coronária motivadas pela entrega intracoronária de CEM, na ausência de alterações de outros parâmetros clínicos da circulação coronária utilizados em tempo real. As alterações do IRM são progressivas e passíveis de avaliar o efeito/dose, embora não tenha sido possível determinar diferenças com os dois tipos de CEM. No nosso modelo a injeção intracoronária não se associou a evidência de efeito benéfico na reparação ou regeneração miocárdica após o EAM.---------------------------- ABSTRACT: ABSTRACT Introduction The use of cells for the treatment of cardiovascular disease is a promise for the future and perhaps the only option to overcome some of the shortcomings of current therapies. The strategy for the delivery of cells most often used in current research has been the intracoronary route and due to this microcirculation gains special relevance, mainly because it is the first interaction site of transplanted cells with the native tissue. Mesenchymal stem cells (MSC) have properties that make them suitable for Cell Therapy, but its dimensions, larger than the diameter of capillaries, have prompted controversy about the safety of intracoronary delivery. The interventional cardiology currently has techniques that allow for real-time and in vivo assessment of coronary microcirculation state. The determination of the index of microcirculatory resistance index (IMR) provides information about small vessels, independently of the coronary circulation and hemodynamic status, but the clinical applicability of this knowledge is yet to be defined. Objectives To clarify the potential use of IMR in the study of the effects of MSC through intracoronary transplantation. Population and Methods Preclinical study with swine model developed in three phases. In Phase One 8 healthy animals were used to study and validate the IMR assessment in our animal model. IMR was assessed with two different doses of papaverine for inducing the maximal hyperaemic response (5 and 10 mg) and microcirculation dysfunction was achieved after intracoronary injection with embozene microspheres with 40 μm in diameter. In Phase Two we randomized 18 healthy animals divided between the control group and the one receiving 30 x 106 MSC through an intracoronary infusion. There we blindly evaluated IMR, the aortic pressure, the epicardial coronary flow and the occurrence of ECG changes. In Phase Three we used 18 animals with a provoked acute myocardial infarction (AMI), randomized into a control group, a MSC expanded conventionally receiver group and a MSC expanded with an innovative methodology receiver group. There was a stepwise infusion with doses of 10 x 106, 15 x 106 and 20 x 106 MSC with determination of IMR, the aortic pressure, the epicardial coronary flow and occurrence of electrocardiographic abnormalities. Four weeks after cell delivery we again measured the IMR and proceeded with the pathological study of animals in the search for evidence of neoangiogenesis and myocardial regeneration, or a positive effect in the reparative response following the infarction. Results All animals remained hemodynamically stable and with no electrocardiographic abnormalities, except for the ST elevation in V1-V3 observed after injection of the microspheres. In Phase One the two doses of papaverine achieved an hyperemic and effective response without significant differences in IMR (variation of the distal pressure -11.4 ± 5 and -10.6 ± 5 mmHg with the doses of 5 and 10 mg respectively (p = 0.5). With the injection of the microspheres the IMR had an average increase of 310 ± 190% for an average value of 41.3 ± 16 U (p = 0.001). In the second phase there were no significant differences in hemodynamic parameters, epicardial flow and electrocardiographic assessment between the two groups. The baseline IMR was similar and after intracoronary infusion there was a significant increase in animals receiving cells compared with the control group (8.8 ± U 1 vs. 14.2 ± 1.8, p = 0.02) and with their baseline (112% increase, p = 0.008). In the third phase again there were no significant differences in hemodynamic parameters, the epicardial flow and electrocardiographic evaluation between the three groups. There was a significant increase in IMR in animals that received cells from the 2nd dose (72% in conventional cells and 108% in the innovative cells) that remained with the 3rd dose (100% in conventional cells and 88% in the innovative) with statistical significance compared with the control group (p = 0.034 with 2nd dose, p = 0.024 with 3rd dose). Four weeks after delivery of the MSC we observed the fall of the IMR in the two groups that received cells with values overlapping those of the control group. In pathological and histological evaluation of removed hearts there were no differences among the three groups. Conclusions The IMR allows for the differentiation of changes in coronary microcirculation motivated by intracoronary delivery of MSC in the absence of modification in other clinical parameters. IMR changes are progressive and enable the evaluation of the effect / dose, though it has not been possible to determine differences in the two types of MSC. In our model, intracoronary injection of MSC was not associated with evidence of repair or myocardial regeneration after AMI.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study addressed the application, strength and durability of self-compacting concrete (SCC) in a large-scale construction site, comparing its performance with vibrated conventional concrete (CC) with similar characteristics, assessing its economic feasibility. The studies were undertaken in the Arena Pernambuco project and involved the concreting during May, June and July 2012, for data collection, accompanying the routine concrete control tests and performing specific strength and durability tests. The SCC compressive strength was on average 4.5% higher than the CC one, and its formwork reinforced to withstand greater lateral pressure of the fresh concrete. The durability indicators results were in favour of SCC, which cost was 13.5% higher than CC.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives Unipolar depression (UPD) is a leading cause of global burden of diseases, particularly among the elderly, whose treatment may be challenging. In such cases, ECT is often recommended due to its safety and efficacy. This report presents a case of a 67-year-old male inpatient that developed a rare cardiac complication during ECT. Methods Clinical case report with patient’s consent and bibliographic review. Results A 67-year-old male inpatient with recurrent severe psychotic depression was hospitalized and ECT was indicated after failure of the pharmacological treatment. A comprehensive clinical pre-evaluation revealed only nonspecific ST-segment changes in electrocardiogram. During the 7th ECT session, it was observed transitory ST-segment depression followed by a discrete increase of plasma troponin I. Severe tri-vessel coronary artery stenosis was found and a percutaneous coronary angioplasty was performed, with satisfactory psychiatric and cardiac outcomes. Conclusions Unipolar depression (UPD) and cardiovascular disease are often coexistent conditions, especially among the elderly. In the current case, myocardial ischemia was detected lately during ECT therapy and its treatment allowed the UPD treatment to be completed adequately.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Descrevem-se dois casos de angioplastia transluminal coronária (ATC) com implante de stents em bifurcação de coronária descendente anterior (DA) com artéria diagonal (DI), destacando-se as técnicas utilizadas. No caso 1, implantou-se na DA um flexistent Gianturco-Roubin (GR) e através de suas hastes, um Palmaz-Schatz (PS) no óstio de DI, com sucesso. O reestudo angiográfico em sete meses mostrou ausência de reestenose. No caso 2, implantou-se metade de um stent PS em DA e outro PS em DI, nesta ordem, também com sucesso. No seguimento clínico de seis meses, paciente encontra-se assintomático.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVO: Avaliar retrospectivamente, implante de stent (IS) em paciente com doença arterial coronária (DAC), realizado em 7 hospitais do Rio de Janeiro. MÉTODOS: De junho/94 a dezembro/96, foram realizados 2.220 procedimentos, e desses, analisados 783 IS em 660 (29,7%) pacientes, através da coronariografia sem subtração digital. Os diversos tipos de stent, mais freqüentemente, usados foram: Palmaz-Schatz (40,9%), Gianturco-Roubin (29,1%) e NIR (22,0%). As indicações para o IS foram: lesão de novo, 67,9%; lesão reestenótica, 16,0%; lesão com resultado subótimo da angioplastia transluminal coronária (ATC), 8,2%; oclusão aguda ou provável pós-ATC, 4,9%; oclusão crônica, 3,0%. Todos os stents foram implantados com alta pressão, sem controle pelo ultra-som intracoronário. A prevenção da trombose subaguda, na maioria dos pacientes (87,8%), foi feita com o uso de ticlopidina e ácido acetil-salicílico. RESULTADOS: Evolução imediata: a) sucesso no IS em 770 lesões: 98,0% em 646 (97,9%) pacientes; b) sucesso clínico em 634 (96,0%) casos; c) complicações maiores: infarto agudo do miocárdio (IAM) - 1,1%; cirurgia de revascularização miocárdica (CRM) - 1,4% e óbito - 0,8%; d) complicações vasculares com correção cirúrgica e/ou sangramento - 3,0%. Evolução tardia: a) dos 399 (60,4%) pacientes acompanhados clinicamente, a coronariografia de 121 (30,3%) mostrou retorno da lesão no IS em 79 (19,8%) casos; b) freqüência de outros eventos: IAM - 1,5%; CRM - 2,3%; óbito -1,0% e outra ATC ou procedimento similar - 12,5%. CONCLUSÃO: O estudo multicêntrico mostrou que o IS na DAC pode ser realizado com segurança, alto índice de sucesso imediato, poucas complicações e baixa taxa de eventos cardíacos na evolução tardia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A dissecção coronária iatrogênica é rara, entretanto, apresenta alta mortalidade e morbidade. Diante de uma oclusão coronária aguda é fundamental a restauração imediata da perviabilidade do vaso e, com isso, limitar a extensão e a duração da isquemia. Neste contexto o procedimento usual tem sido a revascularização miocárdica de emergência, precedido pela colocação de um balão intra-aórtico. A principal desvantagem desta abordagem é o tempo necessário para reunir uma equipe cirúrgica. Os autores apresentam caso de uma paciente com dissecção iatrogênica da artéria circunflexa durante o cateterismo diagnóstico, que foi solucionada através da implantação de um stent coronário, com ótimo resultado. Esta técnica apresenta vantagens em termos de velocidade de reperfusão e disponibilidade em centros que realizarão o cateterismo diagnóstico sem cobertura cirúrgica local.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mulher de 60 anos, com angina progressiva e revascularização do miocárdio, há oito anos, com ponte de veia safena para coronária direita e anastomose de artéria mamaria esquerda para artéria descendente anterior. Submetida a implante de stent Gianturco-Roubin II em terço proximal da ponte de veia safena para artéria coronária direita, com resultado insatisfatório pela persistência de lesão residual, provavelmente, decorrente de prolapso para dentro da luz de material aterosclerótico através dos coils. Foi implantado outro stent (Palmaz-Schatz biliar) dentro do stent GRII com sucesso e ótimo resultado angiográfico. Um 2º stent Palmaz-Schatz biliar foi implantado em lesão distal no corpo da ponte, ultrapassando os dois stents, anteriormente implantados, com sucesso. Em algumas situações, implante de stent dentro de outro stent é recurso útil para otimização de resultado angiográfico do implante de um stent.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVO: Apresentar a correção de dissecção da aorta descendente, utilizando stent recoberto com dácron® introduzido através da artéria femoral na sala de hemodinâmica. MÉTODOS: Quatro pacientes foram submetidos à sedação, anestesia local de ambas regiões inguinais e a heparinização sistêmica, com cateter contendo o stent introduzido, através da artéria femoral comum, previamente dissecada, até a aorta descendente no seu terço médio. RESULTADOS: A expansão do stent foi realizada no local onde existia a lesão da íntima, diagnosticada por arteriografia e ecocardiograma. A oclusão da falsa luz foi imediata. O tempo do procedimento foi em média de 1h e 30min. A alta hospitalar ocorreu sem complicações. CONCLUSÃO: Este procedimento poderá proporcionar uma melhora substancial nos resultados do tratamento das dissecções da aorta descendente.

Relevância:

20.00% 20.00%

Publicador: