929 resultados para Contamination for lead


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Periodic arrays of nanorings of morphotropic phase boundary lead zirconium titanate ( PZT) have been successfully fabricated using a novel self-assembly technique: close-packed monolayers of latex nanospheres were deposited onto Pt-coated silicon substrates, and then plasma cleaned to form ordered arrays of isolated nanospheres, not in contact with each other. Subsequent pulsed laser deposition of PZT, high angle argon ion etching and thermal annealing created the arrays of isolated nanorings, with diameters of similar to 100 nm and wall thicknesses of similar to 10 nm. Energy dispersive x-ray analysis confirms that the rings are compositionally morphotropic phase boundary PZT, and high resolution transmission electron microscopy imaging of lattice fringes demonstrates some periodicities consistent with perovskite rather than pyrochlore material. The dimensions of these nanorings, and the expected 'soft' behaviour of the ferroelectric material from which they are made, means that they offer the most likely opportunity to date for observing whether or not vortex arrangements of electrical dipoles, analogous to those seen in ferromagnetic nanostructures, actually exist.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Concentrations of the coccidiostat nicarbazin as low as 2 mg/kg in feed can result in violative drug residues arising in poultry liver. A lateral flow device (LFD) was developed for the detection of contaminating concentrations of nicarbazin following solvent extraction of poultry feeds. Test results, as determined by both visual and instrumental measurement, are available within minutes. For 22 feed samples, nicarbazin-free and fortified at 2 mg/kg, the % relative inhibition ranged from 0 to 45% and from 53 to 85%, respectively. Nicarbazin contamination at the critical concentration (2 mg/kg) can be determined in all cases providing the sampling is representative. A wide range of feed samples taken at a mill that incorporated nicarbazin into poultry feed were analyzed. Data generated for these samples by both the LFDs and a mass spectrometric method were compared, and a significant correlation was achieved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nicarbazin and halofuginone have been widely used as coccidiostats for the prevention and treatment of coccidiosis in poultry. It has been shown that accidental cross-contamination of feed can lead to residues of these compounds in eggs and/or muscle. This paper describes a direct competitive assay for detecting halofuginone and nicarbazin, developed as qualitative screening assay. In an optimized competitive ELISA, antibodies showed 50% binding inhibition at approximately 0.08 ng ml(-1) for halofuginone and 2.5 ng ml(-1) for dinitrocarbanilide (marker residue for nicarbazin). Extraction from the matrix was carried out with acetonitrile followed by a wash with hexane. The assay's detection capability (CCbeta) for halofuginone was

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Atomic absorption spectroscopy of the ionic liquid 1-ethyl-3-methylimidazolium ethanoate ([emim](2)[O2CMe]), prepared according to International Patent WO 96/18459, showed it to contain large amounts of lead impurity: (ca. 0.5 M): [emim](2)[Pb(O2CMe)(4)] was isolated and shown crystallographically to contain the first known example of a monomeric, homoleptic pentacoordinate lead(ii) carboxylate complex, with a stereochemically active lone-pair.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The dose received by anatomical structures which are apparently shielded by lead blocks during a course of megavoltage radiotherapy may not be negligible. The dose has three main components; there is that due to radiation transmitted through the shielding block, that due to radiation scattered within the patient and that due to radiation scattered prior to reaching the patient and so circumventing the shield. A calculation method which separates the three components has been investigated and the results have been compared with measurements in a wide range of test situations for both cobalt-60 and 6 MV photon beams. The method of calculation predicts the dose behind the shielding block with acceptable accuracy in all the conditions investigated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: Environmental turbulence including rapid changes in technology and markets has resulted in the need for new approaches to performance measurement and benchmarking. There is a need for studies that attempt to measure and benchmark upstream, leading or developmental aspects of organizations. Therefore, the aim of this paper is twofold. The first is to conduct an in-depth case analysis of lead performance measurement and benchmarking leading to the further development of a conceptual model derived from the extant literature and initial survey data. The second is to outline future research agendas that could further develop the framework and the subject area.

Design/methodology/approach: A multiple case analysis involving repeated in-depth interviews with managers in organisational areas of upstream influence in the case organisations.

Findings: It was found that the effect of external drivers for lead performance measurement and benchmarking was mediated by organisational context factors such as level of progression in business improvement methods. Moreover, the legitimation of the business improvement methods used for this purpose, although typical, had been extended beyond their original purpose with the development of bespoke sets of lead measures.

Practical implications: Examples of methods and lead measures are given that can be used by organizations in developing a programme of lead performance measurement and benchmarking.

Originality/value: There is a paucity of in-depth studies relating to the theory and practice of lead performance measurement and benchmarking in organisations.