973 resultados para Contamination by hydrocarbons
Resumo:
Simulated cold-start tests have been carried out to evaluate the performance of H-ZSM-5 and H-BETA zeolites as hydrocarbon traps under simulated gasoline car exhaust gases, paying special attention to the effect of water on their behaviour. It is concluded that the hydrothermal treatment of the zeolites in the acidic form contributes to the better performance of these materials as hydrocarbon traps since the stabilization of the zeolites takes place. Moreover, the decrease of the surface acidity of the zeolites results in an increase of the Si/Al ratio, which contributes to the decrease of the water affinity for adsorption sites. Thus, the competition with hydrocarbon molecules in the exhaust for the adsorption sites is reduced which increases their trap efficiency. The stabilized H-ZSM-5 is the zeolite that showed the best performance with a propene offset temperature of 240 °C, which should be high enough for the three-way catalyst to carry out its role as catalytic converter.
Resumo:
A probabilistic function (integrated source contribution function, ISCF) based on backward air mass trajectory calculation was developed to track sources and atmospheric pathways of polycyclic aromatic hydrocarbons (PAHs) to the Canadian High Arctic station of Alert. In addition to the movement of air masses, the emission intensities at the sources and the major processes of partition, indirect photolysis, and deposition occurring on the way to the Arctic were incorporated into the ISCF. The predicted temporal trend of PAHs at Alert was validated by measured PAH concentrations throughout 2004. The PAH levels in the summer are orders of magnitude lower than those in the winter and spring when long-range atmospheric transport events occur more frequently. PAHs observed at Alert are mostly from East Asia (including Russia Far East), North Europe (including European Russia), and North America. These sources account for 25, 45, and 27% of PAHs atmospheric level at Alert, respectively. Source regions and transport pathways contributing to the PAHs contamination in the Canadian High Arctic vary seasonally. In the winter, Russia and Europe are the major sources. PAHs from these sources travel eastward and turn to the north at approximately 120°E before reaching Alert, in conjunction with the well- known Arctic haze events. In the spring, PAHs from Russia and Europe first migrate to the west and then turn to the north at 60°W toward Alert. The majority of PAHs in the summer are from northern Canada where they are carried to Alert via low- level transport pathways. In the fall, 70% of PAHs arriving at Alert are delivered from North American sources.
Resumo:
Polycyclic aromatic hydrocarbons (PAHs) are common environmental contaminants which can be derived from anthropogenic sources, such as combustion and discharges from extraction and transport, and natural processes, including leakage and erosion of fossil carbon. Natural PAH sources contribute, along with biological activities and terrestrial run-off, to the organic carbon content in sediments.The Barents Sea region is far from many anthropogenic sources of PAH, but production and trans-shipment of hydrocarbons is increasing. We present data for polycyclic aromatic hydrocarbon (PAH) concentrations in bottom sediments from 510 stations in the Barents and White Seas, and along the northern coast of Norway.
Resumo:
"100-78."
Resumo:
From October 2014 to March 2015, I provided excavation oversight services at a property with substantial environmental concerns. The property in question is located near downtown Seattle and was formerly occupied by the Washington’s first coal gasification plant. The plant operated from 1888 to 1908 and produced coal gas for municipal use. A coal tar like substance with a characteristically high benzene concentration was a byproduct of the coal gasification process and heavily contaminated at or below the surface grade of the plant as shown in previous investigations on the property. Once the plant ceased operation in 1908 the property was left vacant until 1955 when the site was filled in and a service station was built on the property. The main goal of the excavation was not to achieve cleanup on the property, but to properly remove what contaminated soil was encountered during the redevelopment excavation. Areas of concern were identified prior to the commencement of the excavation and an estimation of the extent of contamination on the property was developed. “Hot spots” of contaminated soil associated with the fill placed after 1955 were identified as areas of concern. However, the primary contaminant plume below the property was likely sourced from the coal gasification plant, which operated at an approximate elevation of 20 feet. We planned to constrain the extents of the soil contamination below the property as the redevelopment excavation progressed. As the redevelopment excavation was advanced down to an elevation of approximately 20 feet, soil samples were collected to bound the extents of contamination in the upper portion of the site. The hot spots, known pockets of carcinogenic polycyclic aromatic hydrocarbons (cPAH) located above 20 feet elevation, were excavated as part of the redevelopment excavation. Once a hot spot was excavated, soil samples were collected from the north, south, east, west and bottom sidewalls of the hot spot excavation to check for remaining cPAH. Additionally, four underground storage tanks (USTs) associated with the service station were discovered and subsequently removed. Soil samples were also collected from the resulting UST excavation sidewalls to check for remaining petroleum hydrocarbons. Once the excavation reached its final excavation depth of 20 to 16 feet in elevation, bottom of excavation samples were collected on a 35 foot by 35 foot grid to test for concentrations of contaminants remaining onsite. Once the redevelopment excavation was complete, soils observed from borings drilled for either structural elements, geotechnical wells, or environmental wells were checked for any evidence of contamination using field screening techniques. Evidence of contamination was used to identify areas below the final excavation grade which had been impacted by the operation of the coal gasification plant. Samples collected from the excavation extents of hot spots and USTs show that it was unlikely that any contamination traveled from the post-1955 grade down to the pre-1955 grade. Additionally, the lack of benzene in the bottom of excavation samples suggests that a release from the coal gasification plant occurred below the redevelopment excavation final elevations of 20 to 16 feet. Qualitative data collected from borings for shoring elements and wells indicated that the spatial extent of the subsurface contaminant plume was different than initially estimated. Observations of spoils show that soil contamination extends further to the southwest and not as far to the east and north than originally estimated. Redefining the extent of the soil contamination beneath the property will allow further subsurface investigations to focus on collecting quantitative data in areas that still represent data gaps on the property, and passing over areas that have shown little signs of contamination. This information will help with the formation of a remediation plan should the need to clean up the site arise in the future.
Resumo:
We observed unexpected high plasma concentrations of tobrarriycin (48.5 and 28.1 mg/L) in fingerprick blood samples after the nebulization of tobramycin solution for inhalation (tobramycin 300 mg/5 mL, TOBI(R)) by 2 young children aged 3 years. To investigate whether dermal contamination could be the source of error, 3 adult volunteers were present during another nebulization by a third child (age 2 years). The volunteers had exposure to tobramycin by handling the nebulizer or the nebule and also by inhalation from holding the child and being in close proximity while TOBI(R) was being administered. Five blood samples by fingerprick and 2 by venipuncture were collected and assayed for tobramycin concentration. On each occasion the site was swabbed with alcohol wipes to mimic standard patient sampling methods. One site was resampled after cleaning of hands with 2% chlorhexidine gluconate and water. Tobramycin concentrations from venipuncture 1-2 hours after nebulization were all < 0.2 mg/L except for 1 result of 1.2 mg/L. The tobramycin concentrations from fingerpricks before hand washing varied between 6.8 and 172 mg/L, and after hand washing between 0.3 and 17.6 mg/L. Contamination of fingers with tobramycin is likely to have caused the error in the 2 initial cases and did cause misleadingly elevated levels in the adult volunteers. We caution that therapeutic drug monitoring of nebulized tobramycin should not be done by fingerprick sampling, and care should be taken to avoid contamination of the venipuncture site.
Resumo:
A clinical study was undertaken to compare the surface microbial contamination associated with pens constructed of either a copper alloy or stainless steel used by nurses on intensive care units. A significantly lower level of microbial contamination was found on the copper alloy pens. Copyright © 2011 by the Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.
Resumo:
A pilot scale multi-media filtration system was used to evaluate the effectiveness of filtration in removing petroleum hydrocarbons from a source water contaminated with diesel fuel. Source water was artificially prepared by mixing bentonite clay and tap water to produce a turbidity range of 10-15 NTU. Diesel fuel concentrations of 150 ppm or 750 ppm were used to contaminate the source water. The coagulants used included Cat Floc K-10 and Cat Floc T-2. The experimental phase was conducted under direct filtration conditions at constant head and constant rate filtration at 8.0 gpm. Filtration experiments were run until the filter reached its clogging point as noted by a measured peak pressure loss of 10 psi. The experimental variables include type of coagulant, oil concentration and source water. Filtration results were evaluated based on turbidity removal and petroleum hydrocarbon (PHC) removal efficiency as measured by gas chromatography. Experiments indicated that clogging was controlled by the clay loading on the filter and that inadequate destabilization of the contaminated water by the coagulant limited the PHC removal. ^