970 resultados para Breathing apparatus.
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
The wear resistance of denture teeth is important to the longevity of removable prostheses of edentulous patients. The ability of denture teeth to maintain a stable occlusal relationship over time may be influenced by this property. The purpose of this in vitro study was to evaluate the wear resistance of polymethyl methacrylate (PMMA) denture teeth based on their chemical composition when opposed by a ceramic antagonist. The maxillary canines (n=10) of 3 PMMA denture teeth (Trubyte Biotone, cross-linked PMMA; Trilux, highly cross-linked IPN (interpenetrating polymer network)-PMMA; and Vivodent, highly cross-linked PMMA) were secured in an in vitro 2-body wear-testing apparatus that produced sliding contact of the specimens (4.5 cycles/s, sliding distance of 20 mm, under 37°C running water) against glazed or airborne particle abraded ceramic. Wear resistance was measured as height loss (mm) under 300 g (sliding force) after 100,000 cycles, using a digital measuring microscope. Mean values were analyzed by 2-way ANOVA and Tukey's test (a=0.05). The wear of Trubyte Biotone (0.93 ± 0.14 mm) was significantly higher than that of both other types of teeth tested against abraded ceramic (p<0.05). The Vivodent tooth (0.64 ± 0.17 mm) exhibited the best wear resistance among the denture teeth tested against airborne particle abraded ceramic. There were no statistically significant differences (p>0.05) in wear among the 3 denture teeth evaluated against glazed ceramic. Trilux and Vivodent teeth tested against either glazed or airborne particle abraded ceramic did not differ significantly from each other (p<0.05). All teeth showed significantly more wear against airborne particle abraded ceramic than against glazed ceramic (p<0.05). In conclusion, the three types of PMMA denture teeth presented significantly different wear resistance against the abraded ceramic. The high-strength PMMA denture teeth were more wear-resistant than the conventional PMMA denture tooth.
Resumo:
OBJETIVO: o presente estudo propõe-se a comparar as dimensões da nasofaringe e as características esqueléticas avaliadas por exame cefalométrico, em indivíduos com padrões morfológicos distintos. MÉTODOS: foram utilizadas 90 telerradiografias de pacientes de ambos os gêneros, de 12 a 16 anos de idade, as quais foram igualmente divididas em três grupos distintos, referentes aos padrões morfológicos - braquifacial, mesofacial e dolicofacial. Foram realizadas medições específicas da região nasofaringeana (ad1-Ptm, ad2-Ptm, ad1-Ba, ad2-S0, (ad1-ad2-S0-Ba-ad1/Ptm-S 0-Ba-Ptm) X 100, e Ptm-Ba) e relativas ao padrão esquelético da face. RESULTADOS: observou-se que os pacientes dolicofaciais apresentaram menor profundidade sagital óssea (Ptm-Ba) e da via aérea da nasofaringe (ad1-Ptm e ad2-Ptm). Sugere-se que essas diferenças estejam relacionadas a um posicionamento relativamente mais posterior da maxila, comum a esses pacientes. Todavia, não foram detectadas diferenças quanto à espessura de tecido mole na parede posterior nasofaringeana (ad1-Ba e ad2-S0), ou à sua proporção em relação a toda a área delimitada para a nasofaringe [(ad1-ad2-S0-Ba-ad1/Ptm-S 0-Ba-Ptm) X 100]. CONCLUSÃO: sugere-se, portanto, que as características faciais de excesso vertical encontradas em pacientes dolicofaciais podem ocorrer, dentre outros fatores, em virtude da obstrução da via aérea nasofaringeana, uma vez que tais dimensões se apresentaram menores para os dolicofaciais.
Resumo:
The purpose of this study was to evaluate the influence of intrapulpal pressure simulation on the bonding effectiveness of etch & rinse and self-etch adhesives to dentin. Eighty sound human molars were distributed into eight groups, according to the permeability level of each sample, measured by an apparatus to assess hydraulic conductance (Lp). Thus, a similar mean permeability was achieved in each group. Three etch & rinse adhesives (Prime & Bond NT - PB, Single Bond -SB, and Excite - EX) and one self-etch system (Clearfil SE Bond - SE) were employed, varying the presence or absence of an intrapulpal pressure (IPP) simulation of 15 cmH2O. After adhesive and restorative procedures were carried out, the samples were stored in distilled water for 24 hours at 37°C, and taken for tensile bond strength (TBS) testing. Fracture analysis was performed using a light microscope at 40 X magnification. The data, obtained in MPa, were then submitted to the Kruskal-Wallis test ( a = 0.05). The results revealed that the TBS of SB and EX was significantly reduced under IPP simulation, differing from the TBS of PB and SE. Moreover, SE obtained the highest bond strength values in the presence of IPP. It could be concluded that IPP simulation can influence the bond strength of certain adhesive systems to dentin and should be considered when in vitro studies are conducted.
Resumo:
INTRODUÇÃO: A Prótese Implantável de Condução Óssea (BAHA) consiste em uma excelente opção na reabilitação auditiva de pacientes com perda auditiva condutiva e mista uni ou bilateral, e sensorioneural unilateral. Tem sido uma alternativa vantajosa sobre os aparelhos de condução óssea convencionais e os aparelhos de amplificação sonora individuais (AASI) quando o uso dos mesmos fica impossibilitado pela presença de otite externa crônica de difícil controle clínico. OBJETIVO: Apresentar o primeiro caso de BAHA realizado no Brasil, após a autorização da ANVISA, para a reabilitação da perda auditiva mista com episódios de otite externa crônica. MÉTODO: Paciente do sexo feminino, 50 anos, com perda auditiva de grau moderado à direita e severo à esquerda, zumbido bilateral, decorrente de otosclerose, submetida a quatro cirurgias de estapedotomia e com impossibilidade de uso de AASI devido a otorreia e otalgia bilateral. A avaliação médica e audiológica indicaram o benefício do BAHA. Realizada a cirurgia e implantação do sistema BAHA, a paciente apresentou melhora significativa nos limiares audiométricos, na percepção e discriminação da fala, além de relatar extrema satisfação relacionada ao fator estético. COMENTÁRIOS FINAIS: O processo cirúrgico do BAHA é seguro, simples e rápido, proporcionando excelentes resultados audiológicos e alto grau de satisfação por parte dos pacientes.
Resumo:
Ituglanis mambai, new species, is described from a cave in the Mambaí karst area, State of Goiás, Central Brazil. The new species distinguishes from epigean and cave congeners by the combination of the following characteristics: posterior supraoccipital fontanel absent; pectoral-fin rays usually i,7; six pleural ribs; total vertebrae 37-38 behind Weberian apparatus; shorter predorsal length (65.1-70.8% SL); shorter caudal peduncle length (8.4-11.9% SL); shorter dorsal-fin base length (7.7-11.3% SL); wider interobital width (29.2-36.5% HL); larger mouth width (43.4-64.0% HL); intermediate between epigean and other cave Ituglanis species as regards to both eyes (diameter varying from 0.5 to1.0 mm in adults, 7.8-10.1 % HL) and pigmentation, composed by irregular light brown spots along the body. The latter indicate the troglobitic status for I. mambai. In addition, this species has the maxillae with a discrete medial-posterior projection; fronto-lacrimal one half-length of the maxillae and pointed backwards; posterior process of palatine half its length, with a tenuous medial concavity; 14 dorsal and 12 ventral procurrent rays. In the natural habitat, I. mambai displayed cryptobiotic habits, trying to hide in the graveled bottom or under boulders when disturbed, apparently showing a negative response to light. It was observed a preference to slow-moving waters. Recent flood marks were observed in the stream conduit in March/April 2007 (end of the rainy season) when less individuals were observed on 300 m of the subterranean stream compared to September 2004 (end of the dry season).
Resumo:
Cefalópodes coleóides (lulas, sépias e polvos) produzem espermatóforos muito complexos que são transferidos à fêmea durante a cópula por meio do hectocótilo, um apêndice modificado nos machos. Durante a transferência à fêmea, ocorre a chamada "reação espermatofórica", complexo processo de evaginação do aparato ejaculatório do espermatóforo, que conduz à exteriorização da massa espermática e corpo cimentante. A presente revisão sintetiza o conhecimento acerca da morfologia e funcionamento desta estrutura exclusiva dos coleóides, identificando lacunas e definindo estratégias que possibilitem avanços na área. Poucos trabalhos abordam com detalhes a morfologia e anatomia funcional dos espermatóforos dos cefalópodes, grande parte do conhecimento acerca da estrutura do espermatóforo tendo sido gerada por trabalhos clássicos do século XIX e início do século XX. Investigações acerca do funcionamento dos espermatóforos são consideravelmente mais raras, estando o conhecimento básico sobre a reação espermatofórica restrito a apenas 19 espécies de coleóides. A revisão da literatura especializada permite sugerir que existem dois tipos básicos de fixação de espermatóforos em Decapodiformes (lulas e sepióides): fixação superficial e implante profundo (ou intra-dérmico). Na fixação superficial, comum em diversas espécies (e.g., Loliginidae, Sepiidae, Ommastrephidae), a base dos espermatângios é aderida ao tecido-alvo aparentemente por meio do corpo cimentante, a partir de substâncias adesivas e, em alguns casos, estruturas de fixação. No implante profundo, comum em alguns grupos de lulas oceânicas e de águas profundas (e.g., Architeuthidae, Cranchiidae, Octopoteuthidae, Sepiolidae), os espermatóforos implantam-se inteiramente no corpo da fêmea, de forma autônoma. Permanece desconhecido o mecanismo responsável pelo implante profundo. Em Octopodiformes (polvos), o espermatóforo é inserido no gonoduto feminino, alcançando a glândula oviducal, onde estão localizadas as espermatecas, ou a cavidade do ovário. Como o funcionamento extracorpóreo dos espermatóforos depende exclusivamente da intrincada estrutura e organização de seus componentes (e.g., membranas e túnicas), somente investigações detalhadas dessas estruturas proverão as bases para a compreensão do funcionamento e da exata função do complexo espermatóforo dos coleóides. Recomenda-se o desenvolvimento de um protocolo simples e eficiente para coloração e preparação total de espermatóforos, de forma que seja possível expandir as descrições morfológicas do espermatóforo em estudos taxonômicos e anatômicos, permitindo, portanto, ampliação do conhecimento acerca desta enigmática estrutura.
Resumo:
The arterial partial pressure (P CO2) of carbon dioxide is virtually constant because of the close match between the metabolic production of this gas and its excretion via breathing. Blood gas homeostasis does not rely solely on changes in lung ventilation, but also to a considerable extent on circulatory adjustments that regulate the transport of CO2 from its sites of production to the lungs. The neural mechanisms that coordinate circulatory and ventilatory changes to achieve blood gas homeostasis are the subject of this review. Emphasis will be placed on the control of sympathetic outflow by central chemoreceptors. High levels of CO2 exert an excitatory effect on sympathetic outflow that is mediated by specialized chemoreceptors such as the neurons located in the retrotrapezoid region. In addition, high CO2 causes an aversive awareness in conscious animals, activating wake-promoting pathways such as the noradrenergic neurons. These neuronal groups, which may also be directly activated by brain acidification, have projections that contribute to the CO2-induced rise in breathing and sympathetic outflow. However, since the level of activity of the retrotrapezoid nucleus is regulated by converging inputs from wake-promoting systems, behavior-specific inputs from higher centers and by chemical drive, the main focus of the present manuscript is to review the contribution of central chemoreceptors to the control of autonomic and respiratory mechanisms.
Resumo:
We describe the experimental apparatus and the methods to achieve Bose-Einstein condensation in 87Rb atoms. Atoms are first laser cooled in a standard double magneto-optical trap setup and then transferred into a QUIC trap. The system is brought to quantum degeneracy selectively removing the hottest atoms from the trap by radio-frequency radiation. We also present the main theoretical aspects of the Bose-Einstein condensation phenomena in atomic gases.
Resumo:
This article describes the use of a projection spectrograph based on an overhead projector for use in classroom demonstrations on light polarization and optical activity. A simple adaptation on a previously developed apparatus allows illustrating several aspects of optical activity, such as circular and linear birefringence, including their wavelength dependence. Specifically, we use the projection spectrograph to demonstrate the optical activity of an aqueous solution of sugar (circular birefringence), of a quartz plate and of an overhead projector transparence film (linear birefringence). A historical survey about the optical activity discovery and the main principles involved is also presented.
Resumo:
This article describes a projection spectrograph for use in optical spectroscopy classrooms demonstrations. The apparatus is based on an overhead projector and permits the visualization of several phenomena such as, light dispersion by diffraction gratings, diffraction order, optical fluorescence, continuous and discrete optical emission spectra, and light absorption by liquids and solids. A historical survey about the optical spectroscopy development is also presented.
Resumo:
OBJETIVO: O objetivo deste trabalho foi estudar a grandeza practical peak voltage (PPV), determinada a partir da forma de onda de tensão aplicada a tubos radiológicos, e compará-la com algumas definições de kVp para diferentes tipos de geradores: monofásico (onda completa, clínico), trifásico (seis pulsos, clínico) e potencial constante (industrial). MATERIAIS E MÉTODOS: O trabalho envolveu a comparação do PPV medido invasivamente (utilizando um divisor de tensão) com a resposta de dois medidores comerciais não invasivos, além dos valores de outras grandezas usadas para medição da tensão de pico aplicada ao tubo de raios X, e a análise da variação do PPV com a ondulação percentual da tensão (ripple). RESULTADOS: Verificou-se que a diferença entre o PPV e as definições mais comuns de tensão de pico aumenta com o ripple. Os valores de PPV variaram em até 3% e 5%, respectivamente, na comparação entre medições invasivas e não invasivas feitas com os equipamentos trifásico e monofásico. CONCLUSÃO: Os resultados demonstraram que a principal grandeza de influência que afeta o PPV é o ripple da tensão. Adicionalmente, valores de PPV obtidos com medidores não invasivos devem ser avaliados considerando que eles dependem da taxa de aquisição e da forma de onda adquirida pelo instrumento.