1000 resultados para Atkinson, Ti-Grace


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Diffusion of Ti through the TiO2 (110) rutile surface plays a key role in the growth and reactivity of TiO2. To understand the fundamental aspects of this important process, we present an analysis of the diffusion of Ti adspecies at the stoichiometric TiO2(110) surface using complementary computational methodologies of density functional theory corrected for on-site Coulomb interactions (DFT+U) and a charge equilibration (QEq) atomistic potential to identify minimum energy pathways. We find that diffusion of Ti from the surface to subsurface (and vice versa) follows an intersticialcy exchange mechanism, involving exchange of surface Ti with the 6-fold coordinated Ti below the bridging oxygen rows. Diffusion in the subsurface between layers also follows an interstitialcy mechanism. The diffusion of Ti is discussed in light of continued attempts to understand the re-oxidation of non-stoichiometric TiO2(110) surfaces.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The first 3-D open-framework TiGaPO complex, constructed from (TiO6)-O-III, (TiO6)-O-IV, GaO4, and PO4 polyhedra, contains pyridinium cations in a 1-D pore network and can be oxidized in air at 543 K with retention of the original framework structure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

There has been limited development in catalyst carriers for magnetic separations where superparamagnetic nanoparticles of a high saturation magnetization with no coercivity are required to isolate expensive catalyst reagent that are subjected to repeated magnetic cycles. By using simple stepwise layer-by-layer nanochemistry techniques, we show that an fee FePt nanomagnet can be created inside each silica particle with tailored dimensions to great precision. Subsequent engineering of the external surface with Ti-O-Si species in an optimum structure to create a unique interface gives high activity and excellent selectivity of the composite material for the trans-stilbene oxidation to the corresponding epoxide in the presence of tert-butyl hydroperoxide. Thus, a new magnetic separable epoxidation catalyst is described. This work clearly demonstrates the significance of nanoengineering of a single catalyst particle by a bottom-up construction approach in modern catalyst design, which could lead to new catalytic. properties.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Reaction of with one or two equivalents of LiPPh2 afforded the new phosphanidometal(III) complexes . Reaction of 2 with LiC≡CSiMe3 led to the diamagnetic zirconium(III) alkynyl derivative [{Zr(C5H5)(μ−C≡CSiMe3)}2(μ−η5−C5H4−η5−C5H4], 7. Alkylation of 6 with LiCH2CMe2Ph gave [{Zr(η5−C5H5)(CH2CMe2Ph)2}2{μ−(η5−C5H4)}], 8. A detailed NMR study of complexes 3 and 4 allowed the observation of the spectral behaviour of the eight different fulvalene protons through their coupling to the 31P nucleus. The fluxional behaviour of complex 7 was studied by dynamic DNMR, and kinetic parameters for the σ-π-conversion of the alkynyl ligand were determined. The molecular structures of complexes 3 and 7 were determined by X-ray diffraction methods.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The reaction of the fulvalene titanium(III) hydride [{Ti(η5-C5H5)(μ-H)}2(μ-η5-η5-C10H8)] (1) with chlorine leads to [{Ti(η5-C5H5)(μ-Cl)}2(μ-η5-η5-C10H8)] (3) and [{Ti(η5-C5H5)Cl2}2(μ-η5-η5-C10H8)] (4). The reaction of 3 with azobenzene, in wet toluene, gives [{Ti(η5-C5H5)Cl}2(μ-O)(μ-η5-η5-C10H8)] (5) and 1,2-diphenyl hydrazine. The alkylation of 4 and the analogous zirconium complex [{Zr(η5-C5H55)Cl2}2(μ-η5-η5-C10H8)] (2) with LiCH2SiMe3 or LiCH3 permits isolation of the tetraalkyl derivatives [{M(η5-C5H5)(CH2SiMe3)2}2(μ-η5-η5-C10H8)] (M  Ti (6); Zr (8)) and [{Ti(η5-C5H5)(CH3)2}2(μ-η5-η5C10H8)] (7). All the new fulvalene compounds were characterized by IR, and 1H and 13C NMR spectroscope, and mass spectra and 5 by X-ray diffraction. The structure of 5 is very similar to that of the comparable TiIV compound [{Ti(η5-C5H5)2Cl}2(μ-O)] except for the smaller TiOTi angle (159.4° against 173.81°) and a significant deviation from linearity.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article examines advocacy of Catholic restorative justice for clerical child sexual abuse from the standpoint of feminist criminological critiques of the use of restorative mediation in sexual offence cases. In particular, it questions the Catholic invocation of grace and forgiveness of survivors of abuse in light of critical feminist concerns about the exploitation of emotions in restorative practices, especially in regard to sexual and other gender-based offences. In the context of sexual abuse, the Catholic appeal to grace has the potential for turning into an extraordinary demand made of victims not only to rehabilitate offenders and the church in the eyes of the community, but also to work towards the spiritual absolution of the abuser. This unique feature of Catholic-oriented restorative justice raises important concerns in terms of feminist critiques of the risk of abuses of power within mediation, and is also incompatible with orthodox restorative justice theory, which, although it advocates a ‘spiritual’ response to crime, is concerned foremost with the rights, needs and experiences of victims.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

P>This study aimed to verify the effect of modified section method and laser-welding on the accuracy of fit of ill-fitting commercially pure titanium (cp Ti) and Ni-Cr alloy one-piece cast frameworks. Two sets of similar implant-supported frameworks were constructed. Both groups of six 3-unit implant-supported fixed partial dentures were cast as one-piece [I: Ni-Cr (control) and II: cp Ti] and evaluated for passive fitting in an optical microscope with both screws tightened and with only one screw tightened. All frameworks were then sectioned in the diagonal axis at the pontic region (III: Ni-Cr and IV: cp Ti). Sectioned frameworks were positioned in the matrix (10-Ncm torque) and laser-welded. Passive fitting was evaluated for the second time. Data were submitted to anova and Tukey-Kramer honestly significant difference tests (P < 0 center dot 05). With both screws tightened, one-piece cp Ti group II showed significantly higher misfit values (27 center dot 57 +/- 5 center dot 06 mu m) than other groups (I: 11 center dot 19 +/- 2 center dot 54 mu m, III: 12 center dot 88 +/- 2 center dot 93 mu m, IV: 13 center dot 77 +/- 1 center dot 51 mu m) (P < 0 center dot 05). In the single-screw-tightened test, with readings on the opposite side to the tightened side, Ni-Cr cast as one-piece (I: 58 center dot 66 +/- 14 center dot 30 mu m) was significantly different from cp Ti group after diagonal section (IV: 27 center dot 51 +/- 8 center dot 28 mu m) (P < 0 center dot 05). On the tightened side, no significant differences were found between groups (P > 0 center dot 05). Results showed that diagonally sectioning ill-fitting cp Ti frameworks lowers misfit levels of prosthetic implant-supported frameworks and also improves passivity levels of the same frameworks when compared to one-piece cast structures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study presents the in-vivo evaluation of Ti-13Nb-13Zr alloy implants obtained by the hydride route via powder metallurgy. The cylindrical implants were processed at different sintering and holding times. The implants` were characterized for density, microstructure (SEM), crystalline phases (XRD), and bulk (EDS) and surface composition (XPS). The implants were then sterilized and surgically placed in the central region of the rabbit`s tibiae. Two double fluorescent markers were applied at 2 and 3 weeks, and 6 and 7 weeks after implantation. After an 8-week healing period, the implants were retrieved, non-decalcified section processed, and evaluated by electron, UV light (fluorescent labeling), and light microscopy (toluidine blue). BSE-SEM showed close contact between bone and implants. Fluorescent labeling assessment showed high bone activity levels at regions close to the implant surface. Toluidine blue staining revealed regions comprising osteoblasts at regions of newly forming/formed bone close to the implant surface. The results obtained in this study support biocompatible and osseoconductive properties of Ti-13Nb-13Zr processed through the hydride powder route. (c) 2007 Published by Elsevier B.V.