874 resultados para Aorta, Abdominal
Resumo:
OBJECTIVE: This study sought to characterize the inflammatory infiltrate in ascending thoracic aortic aneurysm in patients with Marfan syndrome, familial thoracic aortic aneurysm, or nonfamilial thoracic aortic aneurysm. BACKGROUND: Thoracic aortic aneurysms are associated with a pathologic lesion termed "medial degeneration," which is described as a noninflammatory lesion. Thoracic aortic aneurysms are a complication of Marfan syndrome and can be inherited in an autosomal dominant manner of familial thoracic aortic aneurysm. METHODS: Full aortic segments were collected from patients undergoing elective repair with Marfan syndrome (n = 5), familial thoracic aortic aneurysm (n = 6), and thoracic aortic aneurysms (n = 9), along with control aortas (n = 5). Immunohistochemistry staining was performed using antibodies directed against markers of lymphocytes and macrophages. Real-time polymerase chain reaction analysis was performed to quantify the expression level of the T-cell receptor beta-chain variable region gene. RESULTS: Immunohistochemistry of thoracic aortic aneurysm aortas demonstrated that the media and adventitia from Marfan syndrome, familial thoracic aortic aneurysm, and sporadic cases had increased numbers of T lymphocytes and macrophages when compared with control aortas. The number of T cells and macrophages in the aortic media of the aneurysm correlated inversely with the patient's age at the time of prophylactic surgical repair of the aorta. T-cell receptor profiling indicated a similar clonal nature of the T cells in the aortic wall in a majority of aneurysms, whether the patient had Marfan syndrome, familial thoracic aortic aneurysm, or sporadic disease. CONCLUSION: These results indicate that the infiltration of inflammatory cells contributes to the pathogenesis of thoracic aortic aneurysms. Superantigen-driven stimulation of T lymphocytes in the aortic tissues of patients with thoracic aortic aneurysms may contribute to the initial immune response.
Resumo:
BACKGROUND: A 24-year-old man presented with previously diagnosed Marfan's syndrome. Since the age of 9 years, he had undergone eight cardiovascular procedures to treat rapidly progressive aneurysms, dissection and tortuous vascular disease involving the aortic root and arch, the thoracoabdominal aorta, and brachiocephalic, vertebral, internal thoracic and superior mesenteric arteries. Throughout this extensive series of cardiovascular surgical repairs, he recovered without stroke, paraplegia or renal impairment. INVESTIGATIONS: CT scans, arteriogram, genetic mutation screening of transforming growth factor beta receptors 1 and 2. DIAGNOSIS: Diffuse and rapidly progressing vascular disease in a patient who met the diagnostic criteria for Marfan's syndrome, but was later rediagnosed with Loeys-Dietz syndrome. Genetic testing also revealed a de novo mutation in transforming growth factor beta receptor 2. MANAGEMENT: Regular cardiovascular surveillance for aneurysms and dissections, and aggressive surgical treatment of vascular disease.
Resumo:
OBJECTIVE The purpose of this study was to compare clinical outcomes and sexual function between transvaginal and transabdominal repairs of vesicovaginal fistulae (VVF). STUDY DESIGN Participants (99 women with VVF at a tertiary referral center) were treated with urinary catheterization for 12 weeks and, if the procedure was unsuccessful, underwent repair either the transvaginal (Latzko) or transabdominal technique. Objective clinical parameters were analyzed; subjective outcomes were recorded prospectively at the 6-month follow-up examination with the use of the female sexual function index to evaluate sexual function and the visual analogue scale to measure general disturbance by the fistula. RESULTS After bladder drainage for 12 weeks, 8 patients had spontaneous fistula closure. Demographic variables were similar in the transvaginal (n = 60) and transabdominal (n = 31) repair groups. The transvaginal procedure showed significantly shorter operation times, less blood loss, and shorter hospital stay. Continence rates 6 months after surgery were 82% (transvaginal) and 90% (transabdominal). Sexual function in the 64 sexually active patients was significantly improved, and overall disturbance by the fistula was reduced with both operative techniques. Neither surgical intervention was superior to the other regarding any domain of sexual function or visual analog scale. CONCLUSION Fistula repair improves sexual function and quality of life with no difference attributable to surgical route. Given this and that operating time, blood loss and length of stay are less with the transvaginal approach, the transvaginal approach is preferred in VVF repair if fistula and patient characteristics are suitable.
Resumo:
The interaction of insulin with bovine aorta endothelial (BAE) cells has been studied to determine the effect of insulin on endothelial cells, and investigate the function of the insulin receptor in this cell type. BAE cell insulin receptor is similiar to insulin receptor in other cell types in the time to attain equilibrium binding, its physical properties in a solubilized assay system and affinity for insulin in the low nanomolar range. However, BAE cell insulin receptor has unusual properties in its interaction with insulin at 4$\sp\circ$C that include: (1) the inability to completely dissociate prebound $\sp{125}$I-insulin by dilution with excess insulin or acid rinse treatment, indicating that binding is not completely reversible (2) the inability to remove prebound insulin with trypsin and other proteases (3) the implication of disulfide complex formation during binding (4) the inability of pretreatment with trypsin to lower cell surface binding capacity and (5) the suppression of insulin binding by bacitracin. Interactions of insulin with the receptor at 37$\sp\circ$C showed that (1) BAE cells degrade insulin, but not as extensively as other cell types, and (2) an unusual biphasic interaction of insulin with the BAE cells is observed which is indicative of some regulatory mechanism which modulates binding affinity. Functional characterization of the BAE cell insulin receptor revealed that insulin-induced downregulation and phosphorylation of the receptor was observed, and the extent of these processes were comparable to that demonstrated in non-endothelial cell types. However, in contrast to other cell types, insulin did not stimulate deoxyglucose uptake in BAE cells. We were unable to confirm the receptor-mediated transport of insulin by the receptor across the endothelial cell monolayer as reported by a previous investigator. We could not demonstrate a role for the receptor to promote acute intracellular accumulation of insulin as postulated by several investigators. Thus, while BAE cell insulin receptor has many properties that are similiar to those in other cell types, it is distinctly different in its nondissociable binding at 4$\sp\circ$C, its interaction with insulin at 37$\sp\circ$C, and its functional role in the BAE cell. ^
Resumo:
Objective: To determine the prevalence of and the relationships between the degree and source of hyperandrogenemia, ovulatory patterns and cardiovascular disease risk indicators (blood pressure, indices or amount of obesity and fat distribution) in women with menstrual irregularities seen at endocrinologists' clinic. Design: A cross-sectional study design. Participants: A sample of 159 women with menstrual irregularities, aged 15-44, seen at endocrinologists' clinic. Main Outcome Measures: androgen levels, body mass index (BMI), waist-hip ratio (WHR), systolic and diastolic blood pressure (SBP & DBP), source of androgens, ovulatory activity. Results: The prevalence of hyperandrogenemia was 54.7% in this study sample. As expected, women with acne or hirsutism had an odds ratio 12.5 (95%CI = 5.2-25.5) times and 36 (95%CI = 12.9-99.5) times more likely to have hyperandrogenemia than those without acne or hirsutism. The main findings of this study were the following: Hyperandrogenemic women were more likely to have oligomenorrheic cycles (OR = 3.8, 95%CI = 1.5-9.9), anovulatory cycles (OR = 6.6, 95%CI = 2.8-15.4), general obesity (BMI $\ge$ 27) (OR = 6.8, 95%CI = 2.2-27.2) and central obesity (WHR $\ge$ 127) (OR = 14.5, 95%CI = 6.1-38.7) than euandrogenemic women. Hyperandrogenemic women with non-suppressible androgens had a higher mean BMI (29.3 $\pm$ 8.9) than those with suppressible androgens (27.9 $\pm$ 7.9); the converse was true for abdominal adiposity (WHR). Hyperandrogenemic women had a 2.4 odds ratio (95%CI = 1.0-6.2) for an elevated SBP and a 2.7 odds ratio (95%CI = 0.8-8.8) for elevated DBP. When age differences were accounted for, this relationship was strengthened and further strengthened when sources of androgens were controlled. When the differences in BMI were controlled, the odds ratio for elevated SBP in hyperandrogenemic women increased to 8.8 (95%CI = 1.1-69.9). When the age, the source of androgens, the amount of obesity and the type of obesity were controlled, hyperandrogenemic women had 13.5 (95%CI = 1.1-158.9) odds ratio for elevated SBP. Conclusions: In this study population, the presence of menstrual irregularities are highly predictive for the presence of elevated androgens. Women with elevated androgens have a high risk for obesity, more specifically for central obesity. The androgenemic status is an independent predictor of blood pressure elevation. It is probable that in the general population, the presence of menstrual irregularities are predictive of hyperandrogenemia. There is a great need for a population study of the prevalence of hyperandrogenemia and for longitudinal studies in hyperandrogenemic women (adrenarche to menopause) to investigate the evolution of these relationships. ^
Resumo:
BACKGROUND The majority of radiological reports are lacking a standard structure. Even within a specialized area of radiology, each report has its individual structure with regards to details and order, often containing too much of non-relevant information the referring physician is not interested in. For gathering relevant clinical key parameters in an efficient way or to support long-term therapy monitoring, structured reporting might be advantageous. OBJECTIVE Despite of new technologies in medical information systems, medical reporting is still not dynamic. To improve the quality of communication in radiology reports, a new structured reporting system was developed for abdominal aortic aneurysms (AAA), intended to enhance professional communication by providing the pertinent clinical information in a predefined standard. METHODS Actual state analysis was performed within the departments of radiology and vascular surgery by developing a Technology Acceptance Model. The SWOT (strengths, weaknesses, opportunities, and threats) analysis focused on optimization of the radiology reporting of patients with AAA. Definition of clinical parameters was achieved by interviewing experienced clinicians in radiology and vascular surgery. For evaluation, a focus group (4 radiologists) looked at the reports of 16 patients. The usability and reliability of the method was validated in a real-world test environment in the field of radiology. RESULTS A Web-based application for radiological "structured reporting" (SR) was successfully standardized for AAA. Its organization comprises three main categories: characteristics of pathology and adjacent anatomy, measurements, and additional findings. Using different graphical widgets (eg, drop-down menus) in each category facilitate predefined data entries. Measurement parameters shown in a diagram can be defined for clinical monitoring and be adducted for quick adjudications. Figures for optional use to guide and standardize the reporting are embedded. Analysis of variance shows decreased average time required with SR to obtain a radiological report compared to free-text reporting (P=.0001). Questionnaire responses confirm a high acceptance rate by the user. CONCLUSIONS The new SR system may support efficient radiological reporting for initial diagnosis and follow-up for AAA. Perceived advantages of our SR platform are ease of use, which may lead to more accurate decision support. The new system is open to communicate not only with clinical partners but also with Radiology Information and Hospital Information Systems.
Resumo:
We present a case of a ruptured abdominal aortic aneurysm (AAA) with ambiguous accessory findings on post-mortem computed-tomography (PMCT), post-mortem magnetic resonance (PMMR) imaging, and PMCT-angiography (PMCTA) suggestive of thoracic aortic dissection. The diagnosis of ruptured AAA was confirmed by autopsy; however, there was no aortic dissection. The imaging findings that mimicked the presence of aortic dissection might have been an atypical presentation of post-mortem clotting or sedimentation. This case is an ideal example to illustrate benefits, limitations, and challenges of post-mortem cross-sectional imaging. It serves as a reminder that both, training as well as correlation of imaging findings with autopsy are fundamental to improve our understanding of radiologic findings on post-mortem cross-sectional imaging.
Resumo:
Accurate measurement of abdominal aortic aneurysms is necessary to predict rupture risk and, more recently, to follow aneurysm sac behavior following endovascular repair. Up until this point, aneurysm diameter has been the most common measurement utilized for these purposes. Although aneurysm diameter is predictive of rupture, accurate measurement is hindered by such factors as aortic tortuosity and interobserver variability, and it does not account for variations in morphology such as saccular aneurysms. Additionally, decreases in aneurysm diameter do not completely describe the somewhat complex remodeling seen following endovascular repair of aortic aneurysms. Measurement of aneurysm volume has the advantage of describing aneurysm morphology in a multidimensional fashion, but it has not been readily available or easily measured until recently. This has changed with the introduction of commercially available software tools that permit quicker and easier to perform volume measurements. Whether it is time for volume to replace, or compliment, diameter is the subject of the current debate.
Resumo:
OBJECTIVES The purpose of this study is to delineate changes in aortic geometry and diameter due to dissection. BACKGROUND Aortic diameter is the major criterion for elective ascending aortic replacement for dilated ascending aortas to prevent aortic dissection. However, recommendations are made on the basis of clinical experience and observation of diameters of previously dissected aortas. METHODS Six tertiary centers on 2 continents reviewed their acute aortic dissection type A databases, which contained 1,821 patients. Included were all non-Marfan patients with nonbicuspid aortic valves who had undergone computed tomography angiography <2 years before and within 12 h after aortic dissection onset. Aortic geometry before and after dissection onset were compared. RESULTS Altogether, 63 patients were included (27 spontaneous and 36 retrograde dissections, median age 68 [57; 77] years; 54% were men). In all but 1 patient, maximum ascending aortic diameter was <55 mm before aortic dissection onset. The largest increase in diameter and volume induced by the dissection were observed in the ascending aorta (40.1 [36.6; 45.3] mm vs. 52.9 [46.1; 58.6] mm, +12.8 mm; p < 0.001; 124.0 [90.8; 162.5] cm(3) vs. 171.0 [147.0; 197.0] cm(3), +47 cm(3); p < 0.001). Mean aortic arch diameter increased from 39.8 (30.5; 42.6) mm to 46.4 (42.0; 51.6) mm (+6.6 mm; p < 0.001) and descending thoracic aorta diameter from 31.2 (27.0; 33.3) mm to 34.9 (30.9; 39.5) mm (+3.7 mm; p < 0.001). Changes in thoracic aorta geometry were similar for spontaneous and retrograde etiology. CONCLUSIONS Geometry of the thoracic aorta is affected by aortic dissection, leading to an increase in diameter that is most pronounced in the ascending aorta. Both spontaneous and retrograde dissection result in similar aortic geometry changes.
Resumo:
PURPOSE To determine the variability of apparent diffusion coefficient (ADC) values in various anatomic regions in the upper abdomen measured with magnetic resonance (MR) systems from different vendors and with different field strengths. MATERIALS AND METHODS Ten healthy men (mean age, 36.6 years ± 7.7 [standard deviation]) gave written informed consent to participate in this prospective ethics committee-approved study. Diffusion-weighted (DW) MR imaging was performed in each subject with 1.5- and 3.0-T MR systems from each of three vendors at two institutions. Two readers independently measured ADC values in seven upper abdominal regions (left and right liver lobe, gallbladder, pancreas, spleen, and renal cortex and medulla). ADC values were tested for interobserver differences, as well as for differences related to field strength and vendor, with repeated-measures analysis of variance; coefficients of variation (CVs) and variance components were calculated. RESULTS Interreader agreement was excellent (intraclass coefficient, 0.876). ADC values were (77.5-88.8) ×10(-5) mm(2)/sec in the spleen and (250.6-278.5) ×10(-5) mm(2)/sec in the gallbladder. There were no significant differences between ADC values measured at 1.5 T and those measured at 3.0 T in any anatomic region (P >.10 for all). In two of seven regions at 1.5 T (left and right liver lobes, P < .023) and in four of seven regions at 3.0 T (left liver lobe, pancreas, and renal cortex and medulla, P < .008), intervendor differences were significant. CVs ranged from 7.0% to 27.1% depending on the anatomic location. CONCLUSION Despite significant intervendor differences in ADC values of various anatomic regions of the upper abdomen, ADC values of the gallbladder, pancreas, spleen, and kidney may be comparable between MR systems from different vendors and between different field strengths.