940 resultados para Amperometry (Instrumentation)


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The use of self-calibrating techniques in parallel magnetic resonance imaging eliminates the need for coil sensitivity calibration scans and avoids potential mismatches between calibration scans and subsequent accelerated acquisitions (e.g., as a result of patient motion). Most examples of self-calibrating Cartesian parallel imaging techniques have required the use of modified k-space trajectories that are densely sampled at the center and more sparsely sampled in the periphery. However, spiral and radial trajectories offer inherent self-calibrating characteristics because of their densely sampled center. At no additional cost in acquisition time and with no modification in scanning protocols, in vivo coil sensitivity maps may be extracted from the densely sampled central region of k-space. This work demonstrates the feasibility of self-calibrated spiral and radial parallel imaging using a previously described iterative non-Cartesian sensitivity encoding algorithm.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We present a silicon chip-based approach for the enhanced sensitivity detection of surface-immobilized fluorescent molecules. Green fluorescent protein (GFP) is bound to the silicon substrate by a disuccinimidyl terephtalate-aminosilane immobilization procedure. The immobilized organic layers are characterized by surface analysis techniques, like ellipsometry, atomic force microscopy (AFM) and X-ray induced photoelectron spectroscopy. We obtain a 20-fold enhancement of the fluorescent signal, using constructive interference effects in a fused silica dielectric layer, deposited before immobilization onto the silicon. Our method opens perspectives to increase by an order of magnitude the fluorescent response of surface immobilized DNA- or protein-based layers for a variety of biosensor applications.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: In order to improve the quality of our Emergency Medical Services (EMS), to raise bystander cardiopulmonary resuscitation rates and thereby meet what is becoming a universal standard in terms of quality of emergency services, we decided to implement systematic dispatcher-assisted or telephone-CPR (T-CPR) in our medical dispatch center, a non-Advanced Medical Priority Dispatch System. The aim of this article is to describe the implementation process, costs and results following the introduction of this new "quality" procedure. METHODS: This was a prospective study. Over an 8-week period, our EMS dispatchers were given new procedures to provide T-CPR. We then collected data on all non-traumatic cardiac arrests within our state (Vaud, Switzerland) for the following 12months. For each event, the dispatchers had to record in writing the reason they either ruled out cardiac arrest (CA) or did not propose T-CPR in the event they did suspect CA. All emergency call recordings were reviewed by the medical director of the EMS. The analysis of the recordings and the dispatchers' written explanations were then compared. RESULTS: During the 12-month study period, a total of 497 patients (both adults and children) were identified as having a non-traumatic cardiac arrest. Out of this total, 203 cases were excluded and 294 cases were eligible for T-CPR. Out of these eligible cases, dispatchers proposed T-CPR on 202 occasions (or 69% of eligible cases). They also erroneously proposed T-CPR on 17 occasions when a CA was wrongly identified (false positive). This represents 7.8% of all T-CPR. No costs were incurred to implement our study protocol and procedures. CONCLUSIONS: This study demonstrates it is possible, using a brief campaign of sensitization but without any specific training, to implement systematic dispatcher-assisted cardiopulmonary resuscitation in a non-Advanced Medical Priority Dispatch System such as our EMS that had no prior experience with systematic T-CPR. The results in terms of T-CPR delivery rate and false positive are similar to those found in previous studies. We found our results satisfying the given short time frame of this study. Our results demonstrate that it is possible to improve the quality of emergency services at moderate or even no additional costs and this should be of interest to all EMS that do not presently benefit from using T-CPR procedures. EMS that currently do not offer T-CPR should consider implementing this technique as soon as possible, and we expect our experience may provide answers to those planning to incorporate T-CPR in their daily practice.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The fight against doping is mainly focused on direct detection, using analytical methods for the detection of doping agents in biological samples. However, the World Anti-Doping Code also defines doping as possession, administration or attempted administration of prohibited substances or methods, trafficking or attempted trafficking in any prohibited substance or methods. As these issues correspond to criminal investigation, a forensic approach can help assessing potential violation of these rules. In the context of a rowing competition, genetic analyses were conducted on biological samples collected in infusion apparatus, bags and tubing in order to obtain DNA profiles. As no database of athletes' DNA profiles was available, the use of information from the location detection as well as contextual information were key to determine a population of suspected athletes and to obtain reference DNA profiles for comparison. Analysis of samples from infusion systems provided 8 different DNA profiles. The comparison between these profiles and 8 reference profiles from suspected athletes could not be distinguished. This case-study is one of the first where a forensic approach was applied for anti-doping purposes. Based on this investigation, the International Rowing Federation authorities decided to ban not only the incriminated athletes, but also the coaches and officials for 2 years.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Standard surgical aortic valve replacement with a biological prosthesis remains the treatment of choice for low- and mid-risk elderly patients (traditionally >65 years of age) suffering from severe symptomatic aortic valve stenosis or insufficiency, and for young patients with formal contraindications to long-lasting anticoagulation. Unfortunately, despite the fact that several technical improvements have noticeably improved the resistance of pericardial and bovine bioprostheses to leaflet calcifications and ruptures, the risk of early valve failure with rapid degeneration still exists, especially for patients under haemodialysis and for patients <60 years of age at the time of surgery. Until now, redo open heart surgery under cardiopulmonary bypass and on cardioplegic arrest was the only available therapeutic option in case of bioprosthesis degeneration, but it carried a higher surgical risk when elderly patients with severe concomitant comorbidities were concerned. Since a few years, the advent of new transcatheter aortic valve procedures has opened new horizons in cardiac surgery and, in particular, the possibility of implanting stented valves within the degenerated stented bioprosthesis, the so-called 'valve-in-valve' (VinV) concept, has become a clinical practice in experienced cardiac centres. The VinV procedure represents a minimally invasive approach dedicated to high-risk redo patients, and published preliminary reports have shown a success rate of 100% with absence of significant valvular leaks, acceptable transvalvular gradients and low complication rate. However, this procedure is not riskless and the most important concerns are about the size mismatch and the right positioning within the degenerated bioprosthesis. In this article, we review the limited available literature about VinV procedures, underline important technical details for the positioning and provide guidelines to prevent valve-prosthesis mismatch comparing the three sizes of the only commercially available transapical device, the Edwards Sapien, with the inner diameter of three of the most commonly used stented bioprostheses.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to evaluate the use of the pedometer in epidemiologic research on physical activity. Within the framework of a health examination survey in 1988-1989, physical activity was assessed in a representative population sample of 493 men and women aged 25-74 years who were residents of Switzerland. They wore a pedometer for 1 week at work and during leisure time, and the results, converted into steps per day, were compared with answers to a questionnaire. The average number of steps per day decreased from 11,900 to 6,700 and from 9,300 to 7,300 for men and women, respectively, in the youngest to the oldest age groups. For men, categorized according to type of physical activity at work, there was a highly significant difference in the number of steps (p < 0.001), whereas in women the results were associated with leisure-time physical activity (p = 0.003). For both sexes, practicing sports more than once a week was associated with an important increase in steps per day. Analyzing the number of steps according to the day of the week and occupational category produced an unexpected result: Men with a physically active job engaged in more leisure-time physical activity on the weekend. The pedometer proved to be useful in assessing physical activity in a large, free-living population.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Although spirituality is usually considered a positive resource for coping with illness, spiritual distress may have a negative influence on health outcomes. Tools are needed to identify spiritual distress in clinical practice and subsequently address identified needs. This study describes the first steps in the development of a clinically acceptable instrument to assess spiritual distress in hospitalized elderly patients. METHODS: A three-step process was used to develop the Spiritual Distress Assessment Tool (SDAT): 1) Conceptualisation by a multidisciplinary group of a model (Spiritual Needs Model) to define the different dimensions characterizing a patient's spirituality and their corresponding needs; 2) Operationalisation of the Spiritual Needs Model within geriatric hospital care leading to a set of questions (SDAT) investigating needs related to each of the defined dimensions; 3) Qualitative assessment of the instrument's acceptability and face validity in hospital chaplains. RESULTS: Four dimensions of spirituality (Meaning, Transcendence, Values, and Psychosocial Identity) and their corresponding needs were defined. A formalised assessment procedure to both identify and subsequently score unmet spiritual needs and spiritual distress was developed. Face validity and acceptability in clinical practice were confirmed by chaplains involved in the focus groups. CONCLUSIONS: The SDAT appears to be a clinically acceptable instrument to assess spiritual distress in elderly hospitalised persons. Studies are ongoing to investigate the psychometric properties of the instrument and to assess its potential to serve as a basis for integrating the spiritual dimension in the patient's plan of care.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Le présent cahier qui termine une série consacrée à l'adaptation du "grouper" aux statistiques médicales VESKA des années 1980-1986, a pour but de donner une vue d'ensemble des procédures nécessaires à cette adaptation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The Magnet Tracking System (MTS) is a minimally-invasive technique of continuous evaluation of gastrointestinal motility. In this study, MTS was used to analyse colonic propulsive dynamics and compare the transit of a magnetic pill with that of standard radio-opaque markers. MTS monitors the progress in real time of a magnetic pill through the gut. Ten men and 10 women with regular daily bowel movements swallowed this pill and 10 radio-opaque markers at 8 pm. Five hours of recordings were conducted during 2 following mornings. Origin, direction, amplitude and velocity of movements were analysed relative to space-time plots of the pill trajectory. Abdominal radiographs were taken to compare the progress of both pill and markers. The magnetic pill lay idle for 90% of its sojourn in the colon; its total retrograde displacement accounted for only 20% of its overall movement. Analysis of these movements showed a bimodal distribution of velocities: around 1.5 and 50 cm min(-1), the latter being responsible for 2/3 of distance traversed. There were more movements overall and more mass movements in males. Net hourly forward progress was greater in the left than right colon, and greater in males. The position of the magnetic pill correlated well with the advancement of markers. MTS showed patterns and propulsion dynamics of colonic segments with as yet unmet precision. Detailed analysis of slow and fast patterns of colonic progress makes it possible to specify the motility of colonic segments, and any variability in gender. Such analysis opens up promising avenues in studies of motility disorders.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Contemporary thoracic and cardiovascular surgery uses extensive equipment and devices to enable its performance. As the specialties develop and new frontiers are crossed, the technology needs to advance in a parallel fashion. Strokes of genius or problem-solving brain-storming may generate great ideas, but the metamorphosis of an idea into a physical functioning tool requires a lot more than just a thinking process. A modern surgical device is the end-point of a sophisticated, complicated and potentially treacherous route, which incorporates new skills and knowledge acquisition. Processes including technology transfer, commercialisation, corporate and product development, intellectual property and regulatory routes all play pivotal roles in this voyage. Many good ideas may fall by the wayside for a multitude of reasons as they may not be marketable or may be badly marketed. In this article, we attempt to illuminate the components required in the process of surgical innovation, which we believe must remain in the remit of the modern-day thoracic and cardiovascular surgeon.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To assess the suitability of a hot-wire anemometer infant monitoring system (Florian, Acutronic Medical Systems AG, Hirzel, Switzerland) for measuring flow and tidal volume (Vt) proximal to the endotracheal tube during high-frequency oscillatory ventilation. DESIGN: In vitro model study. SETTING: Respiratory research laboratory. SUBJECT: In vitro lung model simulating moderate to severe respiratory distress. INTERVENTION: The lung model was ventilated with a SensorMedics 3100A ventilator. Vt was recorded from the monitor display (Vt-disp) and compared with the gold standard (Vt-adiab), which was calculated using the adiabatic gas equation from pressure changes inside the model. MEASUREMENTS AND MAIN RESULTS: A range of Vt (1-10 mL), frequencies (5-15 Hz), pressure amplitudes (10-90 cm H2O), inspiratory times (30% to 50%), and Fio2 (0.21-1.0) was used. Accuracy was determined by using modified Bland-Altman plots (95% limits of agreement). An exponential decrease in Vt was observed with increasing oscillatory frequency. Mean DeltaVt-disp was 0.6 mL (limits of agreement, -1.0 to 2.1) with a linear frequency dependence. Mean DeltaVt-disp was -0.2 mL (limits of agreement, -0.5 to 0.1) with increasing pressure amplitude and -0.2 mL (limits of agreement, -0.3 to -0.1) with increasing inspiratory time. Humidity and heating did not affect error, whereas increasing Fio2 from 0.21 to 1.0 increased mean error by 6.3% (+/-2.5%). CONCLUSIONS: The Florian infant hot-wire flowmeter and monitoring system provides reliable measurements of Vt at the airway opening during high-frequency oscillatory ventilation when employed at frequencies of 8-13 Hz. The bedside application could improve monitoring of patients receiving high-frequency oscillatory ventilation, favor a better understanding of the physiologic consequences of different high-frequency oscillatory ventilation strategies, and therefore optimize treatment.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Practical guidelines for monitoring and measuring compounds such as jasmonates, ketols, ketodi(tri)enes and hydroxy-fatty acids as well as detecting the presence of novel oxylipins are presented. Additionally, a protocol for the penetrant analysis of non-enzymatic lipid oxidation is described. Each of the methods, which employ gas chromatography/mass spectrometry, can be applied without specialist knowledge or recourse to the latest analytical instrumentation. Additional information on oxylipin quantification and novel protocols for preparing oxygen isotope-labelled internal standards are provided. Four developing areas of research are identified: (i) profiling of the unbound cellular pools of oxylipins; (ii) profiling of esterified oxylipins and/or monitoring of their release from parent lipids; (iii) monitoring of non-enzymatic lipid oxidation; (iv) analysis of unstable and reactive oxylipins. The methods and protocols presented herein are designed to give technical insights into the first three areas and to provide a platform from which to enter the fourth area.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

L’objectiu del present TFM és explorar les possibilitats del programa matemàtic MATLAB i la seva eina Entorn de Disseny d’Interfícies Gràfiques d’Usuari (GUIDE), desenvolupant un programa d’anàlisi d’imatges de provetes metal·logràfiques que es pugui utilitzar per a realitzar pràctiques de laboratori de l’assignatura Tecnologia de Materials de la titulació de Grau en Enginyeria Mecatrònica que s’imparteix a la Universitat de Vic. Les àrees d’interès del treball són la Instrumentació Virtual, la programació MATLAB i les tècniques d’anàlisi d’imatges metal·logràfiques. En la memòria es posa un èmfasi especial en el disseny de la interfície i dels procediments per a efectuar les mesures. El resultat final és un programa que satisfà tots els requeriments que s’havien imposat en la proposta inicial. La interfície del programa és clara i neta, destinant molt espai a la imatge que s’analitza. L’estructura i disposició dels menús i dels comandaments ajuda a que la utilització del programa sigui fàcil i intuïtiva. El programa s’ha estructurat de manera que sigui fàcilment ampliable amb altres rutines de mesura, o amb l’automatització de les rutines existents. Al tractar-se d’un programa que funciona com un instrument de mesura, es dedica un capítol sencer de la memòria a mostrar el procediment de càlcul dels errors que s’ocasionen durant la seva utilització, amb la finalitat de conèixer el seu ordre de magnitud, i de saber-los calcular de nou en cas que variïn les condicions d’utilització. Pel que fa referència a la programació, malgrat que MATLAB no sigui un entorn de programació clàssic, sí que incorpora eines que permeten fer aplicacions no massa complexes, i orientades bàsicament a gràfics o a imatges. L’eina GUIDE simplifica la realització de la interfície d’usuari, malgrat que presenta problemes per tractar dissenys una mica complexos. Per altra banda, el codi generat per GUIDE no és accessible, cosa que no permet modificar manualment la interfície en aquells casos en els que GUIDE té problemes. Malgrat aquests petits problemes, la potència de càlcul de MATLAB compensa sobradament aquestes deficiències.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Amb el present projecte es proposa fer un estudi de la web semàntica aplicada a la descripció i modelització de la instrumentació marina operada en el context de campanyes d'investigació oceanogràfica.