975 resultados para Abdominal aorta
Resumo:
Dose kernel convolution (DK) methods have been proposed to speed up absorbed dose calculations in molecular radionuclide therapy. Our aim was to evaluate the impact of tissue density heterogeneities (TDH) on dosimetry when using a DK method and to propose a simple density-correction method. METHODS: This study has been conducted on 3 clinical cases: case 1, non-Hodgkin lymphoma treated with (131)I-tositumomab; case 2, a neuroendocrine tumor treatment simulated with (177)Lu-peptides; and case 3, hepatocellular carcinoma treated with (90)Y-microspheres. Absorbed dose calculations were performed using a direct Monte Carlo approach accounting for TDH (3D-RD), and a DK approach (VoxelDose, or VD). For each individual voxel, the VD absorbed dose, D(VD), calculated assuming uniform density, was corrected for density, giving D(VDd). The average 3D-RD absorbed dose values, D(3DRD), were compared with D(VD) and D(VDd), using the relative difference Δ(VD/3DRD). At the voxel level, density-binned Δ(VD/3DRD) and Δ(VDd/3DRD) were plotted against ρ and fitted with a linear regression. RESULTS: The D(VD) calculations showed a good agreement with D(3DRD). Δ(VD/3DRD) was less than 3.5%, except for the tumor of case 1 (5.9%) and the renal cortex of case 2 (5.6%). At the voxel level, the Δ(VD/3DRD) range was 0%-14% for cases 1 and 2, and -3% to 7% for case 3. All 3 cases showed a linear relationship between voxel bin-averaged Δ(VD/3DRD) and density, ρ: case 1 (Δ = -0.56ρ + 0.62, R(2) = 0.93), case 2 (Δ = -0.91ρ + 0.96, R(2) = 0.99), and case 3 (Δ = -0.69ρ + 0.72, R(2) = 0.91). The density correction improved the agreement of the DK method with the Monte Carlo approach (Δ(VDd/3DRD) < 1.1%), but with a lesser extent for the tumor of case 1 (3.1%). At the voxel level, the Δ(VDd/3DRD) range decreased for the 3 clinical cases (case 1, -1% to 4%; case 2, -0.5% to 1.5%, and -1.5% to 2%). No more linear regression existed for cases 2 and 3, contrary to case 1 (Δ = 0.41ρ - 0.38, R(2) = 0.88) although the slope in case 1 was less pronounced. CONCLUSION: This study shows a small influence of TDH in the abdominal region for 3 representative clinical cases. A simple density-correction method was proposed and improved the comparison in the absorbed dose calculations when using our voxel S value implementation.
Resumo:
BACKGROUND: Patients with type 1 diabetes and nephropathy maintain an excess cardiovascular mortality compared with diabetic patients with normoalbuminuria. We sought to evaluate coronary and aortic atherosclerosis in a cohort of asymptomatic type 1 diabetic patients with and without diabetic nephropathy using cardiovascular magnetic resonance imaging. METHODS AND RESULTS: In a cross-sectional study, 136 subjects with long-standing type 1 diabetes without symptoms or history of cardiovascular disease, including 63 patients (46%) with nephropathy and 73 patients with normoalbuminuria, underwent cardiovascular magnetic resonance imaging. All subjects underwent cardiac exercise testing and noninvasive tests for peripheral artery disease and autonomic neuropathy. Coronary artery stenoses were identified in 10% of subjects with nephropathy (versus 0% with normoalbuminuria; P=0.007). Coronary plaque burden, expressed as right coronary artery mean wall thickness (1.7+/-0.3 versus 1.3+/-0.2 mm; P<0.001) and maximum right coronary artery wall thickness (2.2+/-0.5 versus 1.6+/-0.3 mm; P<0.001), was greater in subjects with nephropathy. The prevalence of thoracic (3% versus 0%; P=0.28) and abdominal aortic plaque (22% versus 16%; P=0.7) was similar in both groups. Subjects with and without abdominal aortic plaques had similar coronary plaque burden. CONCLUSIONS: In asymptomatic type 1 diabetes, cardiovascular magnetic resonance imaging reveals greater coronary plaque burden in subjects with nephropathy compared with those with normoalbuminuria.
Resumo:
Tumors in non-Hodgkin lymphoma (NHL) patients are often proximal to the major blood vessels in the abdomen or neck. In external-beam radiotherapy, these tumors present a challenge because imaging resolution prevents the beam from being targeted to the tumor lesion without also irradiating the artery wall. This problem has led to potentially life-threatening delayed toxicity. Because radioimmunotherapy has resulted in long-term survival of NHL patients, we investigated whether the absorbed dose (AD) to the artery wall in radioimmunotherapy of NHL is of potential concern for delayed toxicity. SPECT resolution is not sufficient to enable dosimetric analysis of anatomic features of the thickness of the aortic wall. Therefore, we present a model of aortic wall toxicity based on data from 4 patients treated with (131)I-tositumomab. METHODS: Four NHL patients with periaortic tumors were administered pretherapeutic (131)I-tositumomab. Abdominal SPECT and whole-body planar images were obtained at 48, 72, and 144 h after tracer administration. Blood-pool activity concentrations were obtained from regions of interest drawn on the heart on the planar images. Tumor and blood activity concentrations, scaled to therapeutic administered activities-both standard and myeloablative-were input into a geometry and tracking model (GEANT, version 4) of the aorta. The simulated energy deposited in the arterial walls was collected and fitted, and the AD and biologic effective dose values to the aortic wall and tumors were obtained for standard therapeutic and hypothetical myeloablative administered activities. RESULTS: Arterial wall ADs from standard therapy were lower (0.6-3.7 Gy) than those typical from external-beam therapy, as were the tumor ADs (1.4-10.5 Gy). The ratios of tumor AD to arterial wall AD were greater for radioimmunotherapy by a factor of 1.9-4.0. For myeloablative therapy, artery wall ADs were in general less than those typical for external-beam therapy (9.4-11.4 Gy for 3 of 4 patients) but comparable for 1 patient (32.6 Gy). CONCLUSION: Blood vessel radiation dose can be estimated using the software package 3D-RD combined with GEANT modeling. The dosimetry analysis suggested that arterial wall toxicity is highly unlikely in standard dose radioimmunotherapy but should be considered a potential concern and limiting factor in myeloablative therapy.
Resumo:
New approaches to the clinical treatment of traumatic nerve injuries may one day utilize stem cells to enhance nerve regeneration. Adipose-derived stem cells (ASC) are found in abundant quantities and can be harvested by minimally invasive procedures that should facilitate their use in such regenerative applications. We have analyzed the properties of human ASC isolated from the deep and superficial layers of abdominal fat tissue obtained during abdominoplasty procedures. Cells from the superficial layer proliferate significantly faster than those from the deep layer. In both the deep and superficial layers, ASC express the pluripotent stem cell markers oct4 and nanog and also the stro-1 cell surface antigen. Superficial layer ASC induce the significantly enhanced outgrowth of neurite-like processes from neuronal cell lines when compared with that of deep layer cells. However, analysis by reverse transcription with the polymerase chain reaction and by enzyme-linked immunosorbent assay has revealed that ASC isolated from both layers express similar levels of the following neurotrophic factors: nerve growth factor, brain-derived neurotrophic factor and glial-derived neurotrophic factor. Thus, human ASC show promising potential for the treatment of traumatic nerve injuries. In particular, superficial layer ASC warrant further analysis of their neurotrophic molecules.
Resumo:
BACKGROUND: Visceral obesity (VO) increases technical difficulty in laparoscopic surgery. The body mass index (BMI) does not always correlate to intra-abdominal fat distribution. Our hypothesis was that simple anthropometric measures that reflect VO, could predict technical difficulty in laparoscopic colorectal surgery, as reflected by the operative time, more accurately than the BMI. METHODS: Charts of all consecutive patients who underwent laparoscopic left colon resection in our institution between 2007 and 2010 were reviewed retrospectively. On a preoperative CT scan, anthropometric measures were taken on an axial plane at the L4-L5 level. Demographic, operative and anthropometric CT measures were correlated with the operative time. Logistic regression analysis was performed to assess the value of anthropometric CT measures or BMI to predict the duration of the colectomy. RESULTS: 121 patients with elective left colon resection for benign (56%) or malignant disease (44%) were included. There were 74 sigmoid resections (61%), 21 left hemicolectomies (17%) and 26 low anterior resections (22%). A longer sagittal abdominal diameter (≥24.8 cm) was significantly associated with longer corrected operative time (248 vs. 228 min, p = 0.043). In multivariate analysis, greater sagittal abdominal diameter, sagittal internal diameter and abdominal perimeter were significantly associated with longer operative time. No significant association was found for the BMI neither in univariate nor in multivariate analysis. CONCLUSIONS: This study suggests that simple linear measures taken on a CT scan, such as sagittal abdominal diameter, sagittal internal diameter and abdominal perimeter, may predict longer operative time in laparoscopic left colonic resections more accurately than BMI.
Resumo:
Os autores relatam um caso de tumor de pequenas células redondas desmoplásico intra-abdominal acometendo paciente do sexo masculino, de 21 anos de idade, atendido com quadro de dor abdominal, trombose do membro inferior direito e perda da função renal, de causa obstrutiva. A investigação demonstrou volumosa lesão abdominopélvica, sólida, bocelada, com áreas císticas internas, situada posteriormente à bexiga, causando obstrução ureteral, compressão da veia ilíaca direita e oclusão parcial do reto, além de acometimento de linfonodos intra e retroperitoneais. São descritos os achados cirúrgicos, de ultra-sonografia, tomografia computadorizada e ressonância magnética, bem como aqueles do estudo macroscópico, microscopia e imuno-histoquímica.
Resumo:
Neste trabalho procura-se estabelecer o valor da ultra-sonografia no diagnóstico de apendicite, com transdutor multifreqüencial de 5 a 10 MHz. Foi realizado estudo transversal de casos consecutivos de 240 pacientes, de abril de 1996 a setembro de 1998, com suspeita de apendicite. Os critérios ecográficos de apendicite foram apêndice não-compressível e com espessura acima de 6,0 mm, com ou sem apendicólito e/ou coleção. O padrão ouro utilizado foram achados cirúrgicos e acompanhamento clínico durante um ano. A prevalência de apendicite foi de 59%. A ultra-sonografia mostrou sensibilidade de 90%, especificidade de 97%, acurácia de 93%, valor preditivo positivo de 98% e valor preditivo negativo de 87%, tendo ocorrido 2,4% de falso-positivos e 13% de falso-negativos. O ultra-som com transdutor multifreqüencial de 5 a 10 MHz mostra-se um método muito eficaz no diagnóstico de apendicite.
Resumo:
BACKGROUND: Due to the underlying diseases and the need for immunosuppression, patients after lung transplantation are particularly at risk for gastrointestinal (GI) complications that may negatively influence long-term outcome. The present study assessed the incidences and impact of GI complications after lung transplantation and aimed to identify risk factors. METHODS: Retrospective analysis of all 227 consecutively performed single- and double-lung transplantations at the University hospitals of Lausanne and Geneva was performed between January 1993 and December 2010. Logistic regressions were used to test the effect of potentially influencing variables on the binary outcomes overall, severe, and surgery-requiring complications, followed by a multiple logistic regression model. RESULTS: Final analysis included 205 patients for the purpose of the present study, and 22 patients were excluded due to re-transplantation, multiorgan transplantation, or incomplete datasets. GI complications were observed in 127 patients (62 %). Gastro-esophageal reflux disease was the most commonly observed complication (22.9 %), followed by inflammatory or infectious colitis (20.5 %) and gastroparesis (10.7 %). Major GI complications (Dindo/Clavien III-V) were observed in 83 (40.5 %) patients and were fatal in 4 patients (2.0 %). Multivariate analysis identified double-lung transplantation (p = 0.012) and early (1993-1998) transplantation period (p = 0.008) as independent risk factors for developing major GI complications. Forty-three (21 %) patients required surgery such as colectomy, cholecystectomy, and fundoplication in 6.8, 6.3, and 3.9 % of the patients, respectively. Multivariate analysis identified Charlson comorbidity index of ≥3 as an independent risk factor for developing GI complications requiring surgery (p = 0.015). CONCLUSION: GI complications after lung transplantation are common. Outcome was rather encouraging in the setting of our transplant center.
Resumo:
OBJETIVO: Avaliar a contribuição da ultra-sonografia abdominal em um grupo de pacientes em seguimento pós-tratamento de câncer primário da mama. MATERIAL E MÉTODOS: Foram analisados, retrospectivamente, os resultados dos exames ecográficos abdominais em 100 prontuários de pacientes tratadas de câncer primário da mama, realizados de janeiro a dezembro de 1997, no Setor de Ultra-sonografia da Divisão de Radiologia do Departamento de Clínica Médica da Faculdade de Medicina de Ribeirão Preto da Universidade de São Paulo. Informações como idade, tipo histológico, estadiamento, número e resultados dos exames ultra-sonográficos foram tabelados e analisados. RESULTADOS: Em 70% dos casos os laudos ecográficos abdominais eram normais. O diagnóstico de metástase hepática foi de 3%. CONCLUSÃO: O maior porcentual de alterações encontradas não estava relacionado diretamente como complicação do câncer mamário.
Resumo:
Since the first implantation of an endograft in 1991, endovascular aneurysm repair (EVAR) rapidly gained recognition. Historical trials showed lower early mortality rates but these results were not maintained beyond 4 years. Despite newer-generation devices, higher rates of reintervention are associated with EVAR during follow-up. Therefore, the best therapeutic decision relies on many parameters that the physician has to take in consideration. Patient's preferences and characteristics are important, especially age and life expectancy besides health status. Aneurysmal anatomical conditions remain probably the most predictive factor that should be carefully evaluated to offer the best treatment. Unfavorable anatomy has been observed to be associated with more complications especially endoleak, leading to more re-interventions and higher risk of late mortality. Nevertheless, technological advances have made surgeons move forward beyond the set barriers. Thus, more endografts are implanted outside the instructions for use despite excellent results after open repair especially in low-risk patients. When debating about AAA repair, some other crucial points should be analysed. It has been shown that strict surveillance is mandatory after EVAR to offer durable results and prevent late rupture. Such program is associated with additional costs and with increased risk of radiation. Moreover, a risk of loss of renal function exists when repetitive imaging and secondary procedures are required. The aim of this article is to review the data associated with abdominal aortic aneurysm and its treatment in order to establish selection criteria to decide between open or endovascular repair.
Resumo:
The prevalence of abdominal aortic aneurysm (AAA) in general population is 4-9% with a high mortality rate when ruptured. Therefore, screening programs were developed in many countries to detect small and large AAA in selected patients. Indeed, prevalence of AAA increases in patients over 65 years old with cigarette smoking history. This paper reviews recent literature related to AAA screening focusing on epidemiology, screening tests and evidence based medicine to highlight not only advantages but also disadvantages of screening programs among population.