Resumo:

Objectives: The present study aimed to investigate the feasibility and practicalities or testing children in special school settings using transient evoked otoacoustic emissions (TEOAE) and tympanometry. Children studying in special schools, particularly those with intellectual impairment, may be highly susceptible to hearing pathologies and can be difficult to assess using traditional test batteries. Researchers have recently suggested the possible applicability of TEOAE testing. in lieu of conventional behavioral methods, as a hearing screening device for persons with intellectual impairment. However, to date. few publications have detailed the particulars and results of such testing. Methods: A total of 489 children, with a mean age of 9.6 years, were tested in 15 special schools. Case information was obtained regarding birth history, medical history and type,degree of impairment, for later comparison with screening results. TEOAEs were collected using Quickscreen mode of the ILO292 Otodynamics Analyzer, whilst tympanometry was performed utilizing a Madsen Zodiac 901 Middle Ear Analyzer. Results: In total, 80% of students were able to be tested using TEOAEs. Average test time per ear was 2 min. However, a large proportion (40 of those able to be tested) failed TEOAE testing in at least one ear. No significant effects were found between could-not-test (CNT) cases and case history factors, A significant difference in TEOAE failure rates was found across history of neonatal special care nursery residency and history of parental concern regarding possible hearing impairment. Failure rates were higher for those who indicated positive histories. A total of 74% of subjects could be tested using tympanometry, with 25% of those able to be tested failing in at least one ear. Notably, neither type nor degree of impairment had any significant bearing on CNT or failure rates for tympanometry or TEOAE screening. Conclusions: Findings of the present investigation lend support to the review of hearing screening programs for children in special schools. with TEOAEs presenting as a potential alternative procedure. Further examination of the performance measures of protocols incorporating TEOAEs would now be advantageous. (C) 2002 Elsevier Science Ireland Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to compare transient evoked otoacoustic emission (TEOAE) screening outcomes (pass/fail) across the seasons (spring, autumn, and winter) between infants and schoolchildren. A total of 526 infants (275 boys, 251 girls) with a mean age of 2.0 months (SD = 0.38 months) and 975 schoolchildren (513 boys, 462 girls) with a mean age of 6.2 years (SD = 0.36 years) were screened using the ILO Otodynamics Quickscreen program. The same TEOAE pass/fail criterion was applied to the two groups. The results indicated a significant difference in pass rates between infants (91.2% of 1052 ears) and schoolchildren (86.0% of 1950 ears). A seasonal effect was found only for schoolchildren, with a significantly lower pass rate in winter than in spring or autumn. There was no difference in pass rates between spring and autumn. Implications for the seasonal effect on TEOAE screening outcomes for infants and schoolchildren are discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Handedness, as a potentially influencing, nonpathologic factor, has not been investigated in relation to transient evoked otoacoustic emissions (TEOAEs). The present study aimed to examine the effects of handedness on the TEOAE spectrum in entry-level schoolchildren, with attention also to possible ear asymmetry. A total of 228 subjects (114 males, 114 females, mean age = 6.3 years) were tested using the ILO292 Otodynamics Analyzer (Quickscreen mode) in quiet rooms in 22 schools. For statistical analysis, subjects were matched for factors such as handedness, gender, age, and history of recent ear infection. The results from subjects with passing TEOAE, pure-tone screening, and tympanometry revealed no significant handedness effect overall, although a significant ear asymmetry effect on the measurement parameters of AB difference, noise level, response level, whole-wave reproducibility, band reproducibility, and signal-to-noise ratios was found.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study reexamined the association between speech rate and memory span in children from kindergarten to sixth grade (N = 152) in order to potentially account for the inconsistencies within the published literature on this topic. Some of the inconsistencies in past research may reflect the different methods adopted in assessing speech rate. In particular, repeating word triples may itself involve memory demands, contaminating the correlation between speech rate and memory span in younger children. Analyses using composite speech rate and memory span measures showed that speech rate for word triples shared variance with memory span that was independent of speech rate for single words. Moreover, speech rate for word triples was largely redundant with age in explaining additional variation in memory span once the effects of speech rate for single words were controlled. (C) 2002 Elsevier Science.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study compares the performance of the Quickscreen and Default protocols of the ILO-96 Otodynamics Analyzer in recording transient evoked otoacoustic emissions (TEOAEs) from adults using clinical decision analysis. Data were collected from 25 males (mean age = 29.0 years, SD = 6.8) and 35 females (mean age = 28.1 years, SD = 9.6). The results showed that the mean signal-to-noise ratios obtained from the Quickscreen were significantly greater than those from the Default protocol at 1,2, and 4 kHz. The comparison of the performance of the two protocols, based on the results using receiver operating characteristics curves, revealed a higher performance of the Quickscreen than the Default protocol at 1 and 4 kHz but not at 2 kHz. In view of the enhanced performance of the Quickscreen over the Default protocol in general, the routine use of the Default protocol for testing adults in audiology clinics should be reconsidered.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

TLE in infancy has been the subject of varied research. Topographical and structural evidence is coincident with the neuronal systems responsible for auditory processing of the highest specialization and complexity. Recent studies have been showing the need of a hemispheric asymmetry for an optimization in central auditory processing (CAP) and acquisition and learning of a language system. A new functional research paradigm is required to study mental processes that require methods of cognitive-sensory information analysis processed in very short periods of time (msec), such as the ERPs. Thus, in this article, we hypothesize that the TLE in infancy could be a good model for topographic and functional study of CAP and its development process, contributing to a better understanding of the learning difficulties that children with this neurological disorder have.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work, we investigated structural, morphological, electrical, and optical properties from a set of Cu2ZnSnS4 thin films grown by sulfurization of metallic precursors deposited on soda lime glass substrates coated with or without molybdenum. X-ray diffraction and Raman spectroscopy measurements revealed the formation of single-phase Cu2ZnSnS4 thin films. A good crystallinity and grain compactness of the film was found by scanning electron microscopy. The grown films are poor in copper and rich in zinc, which is a composition close to that of the Cu2ZnSnS4 solar cells with best reported efficiency. Electrical conductivity and Hall effect measurements showed a high doping level and a strong compensation. The temperature dependence of the free hole concentration showed that the films are nondegenerate. Photoluminescence spectroscopy showed an asymmetric broadband emission. The experimental behavior with increasing excitation power or temperature cannot be explained by donor-acceptor pair transitions. A model of radiative recombination of an electron with a hole bound to an acceptor level, broadened by potential fluctuations of the valence-band edge, was proposed. An ionization energy for the acceptor level in the range 29–40 meV was estimated, and a value of 172 ±2 meV was obtained for the potential fluctuation in the valence-band edge.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertation presented to obtain the Ph.D degree in Neuroscience Instituto de Tecnologia Química e Biológica, Universidade Nova de Lisboa

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertation submitted in partial fulfillment of the requirements for the Degree of Master of Science in Geospatial Technologies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Due to the decline of the heavy industries in the Ruhr region, the area has to reinvent itself. The orientation towards service industries proves to be a difficult task for the district and its population. This paper examines the challenges, problems and potentials of the Ruhr region against the backdrop of its economical history out of a sociological perspective. Thereby the economical situation and its outcome towards the population stand in the foreground of the paper.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We are constantly immersed in stimuli. Upon reaching our senses, stimuli are processed within various brain systems along various pathways into the brain, and eventually turned into a percept. However, there are percepts that do not result from responses to external source stimuli. A particular case of this situation is the auditory percept known as tinnitus. Tinnitus can be seen as a task-irrelevant auditory percept, commonly reported to interfere with normal daily tasks. This is known from reports made by tinnitus sufferers that refer to their phantom percept as distracting, and that it diverts their focus from the task-relevant stimuli.(...)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

ABSTRACT Objective The objective of this study was to replicate Babor's Typology and to explore clinical features related to personality traits that may underlie this classification, in order to improve its therapeutic possibilities. Methods Observational prospective study on a group of 273 male alcoholics. After a replication of Babor's variables, Cluster Analysis, Chi-Square – applied on clinical variables related to a Lappda Tipology – and Kappa tests were performed. Results The study identified two distinct clusters that held similar features to those described for the Type A/Type B classification. Besides presenting a lower socio-economic situation, Cluster 2 patients were associated with higher vulnerability and severe clinical features and also differed from Cluster 1 in their response to treatment. These replicated clusters retained connections and also differences in relation to the variables derived from the Lappda Typology. Conclusion Considering that each of the two replicated clusters seem to be associated to different personality traits – according to their correlations to the affective, cognitive and behavioral dimensions brought forward by the Lappda Typology – it is acceptable that this study may contribute to the development of more comprehensive and effective therapeutic strategies specifically tailored to target more specific personality traits of these subgroups of alcoholic patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To assess the changes in ventricular evoked responses (VER) produced by the decrease in left ventricular outflow tract gradient (LVOTG) in patients with hypertrophic obstructive cardiomyopathy (HOCM) treated with dual-chamber (DDD) pacing. METHODS: A pulse generator Physios CTM (Biotronik, Germany) was implanted in 9 patients with severe drug-refractory HOCM. After implantation, the following conditions were assessed: 1) Baseline evaluation: different AV delay (ranging from 150ms to 50 ms) were sequentially programmed during 5 to 10 minutes, and the LVOTG (as determined by Doppler echocardiography) and VER recorded; 2) standard evaluation, when the best AV delay (resulting in the lowest LVOTG) programmed at the initial evaluation was maintained so that its effect on VER and LVOTG could be assessed during each chronic pacing evaluation. RESULTS: LVOTG decreased after DDD pacing, with a mean value of 59 ± 24 mmHg after dual chamber pacemaker, which was significantly less than the gradient before pacing (98 + 22mmHg). An AV delay >100ms produced a significantly lower decrease in VER depolarization duration (VER DD) when compared to an AV delay <=100ms. Linear regression analyses showed a significant correlation between the LVOTG values and the magnitude of VER (r=0.69; p<0.05) in the 9 studied patients. CONCLUSION: The telemetry obtained intramyocardial electrogram is a sensitive means to assess left ventricular dynamics in patients with HOCM treated with DDD pacing.