865 resultados para streak camera
Resumo:
For many drugs, finding the balance between efficacy and toxicity requires monitoring their concentrations in the patient's blood. Quantifying drug levels at the bedside or at home would have advantages in terms of therapeutic outcome and convenience, but current techniques require the setting of a diagnostic laboratory. We have developed semisynthetic bioluminescent sensors that permit precise measurements of drug concentrations in patient samples by spotting minimal volumes on paper and recording the signal using a simple point-and-shoot camera. Our sensors have a modular design consisting of a protein-based and a synthetic part and can be engineered to selectively recognize a wide range of drugs, including immunosuppressants, antiepileptics, anticancer agents and antiarrhythmics. This low-cost point-of-care method could make therapies safer, increase the convenience of doctors and patients and make therapeutic drug monitoring available in regions with poor infrastructure.
Resumo:
We propose a new method, based on inertial sensors, to automatically measure at high frequency the durations of the main phases of ski jumping (i.e. take-off release, take-off, and early flight). The kinematics of the ski jumping movement were recorded by four inertial sensors, attached to the thigh and shank of junior athletes, for 40 jumps performed during indoor conditions and 36 jumps in field conditions. An algorithm was designed to detect temporal events from the recorded signals and to estimate the duration of each phase. These durations were evaluated against a reference camera-based motion capture system and by trainers conducting video observations. The precision for the take-off release and take-off durations (indoor < 39 ms, outdoor = 27 ms) can be considered technically valid for performance assessment. The errors for early flight duration (indoor = 22 ms, outdoor = 119 ms) were comparable to the trainers' variability and should be interpreted with caution. No significant changes in the error were noted between indoor and outdoor conditions, and individual jumping technique did not influence the error of take-off release and take-off. Therefore, the proposed system can provide valuable information for performance evaluation of ski jumpers during training sessions.
Resumo:
Satellite remote sensing imagery is used for forestry, conservation and environmental applications, but insufficient spatial resolution, and, in particular, unavailability of images at the precise timing required for a given application, often prevent achieving a fully operational stage. Airborne remote sensing has the advantage of custom-tuned sensors, resolution and timing, but its price prevents using it as a routine technique for the mentioned fields. Some Unmanned Aerial Vehicles might provide a “third way” solution as low-cost techniques for acquiring remotely sensed information, under close control of the end-user, albeit at the expense of lower quality instrumentation and instability. This report evaluates a light remote sensing system based on a remotely-controlled mini-UAV (ATMOS-3) equipped with a color infra-red camera (VEGCAM-1) designed and operated by CATUAV. We conducted a testing mission over a Mediterranean landscape dominated by an evergreen woodland of Aleppo pine (Pinus halepensis) and (Holm) oak (Quercus ilex) in the Montseny National Park (Catalonia, NE Spain). We took advantage of state-of-the-art ortho-rectified digital aerial imagery (acquired by the Institut Cartogràfic de Catalunya over the area during the previous year) and used it as quality reference. In particular, we paid attention to: 1) Operationality of flight and image acquisition according to a previously defined plan; 2) Radiometric and geometric quality of the images; and 3) Operational use of the images in the context of applications. We conclude that the system has achieved an operational stage regarding flight activities, although with meteorological limits set by wind speed and turbulence. Appropriate landing areas can be sometimes limiting also, but the system is able to land on small and relatively rough terrains such as patches of grassland or short matorral, and we have operated the UAV as far as 7 km from the control unit. Radiometric quality is sufficient for interactive analysis, but probably insufficient for automated processing. A forthcoming camera is supposed to greatly improve radiometric quality and consistency. Conventional GPS positioning through time synchronization provides coarse orientation of the images, with no roll information.
Resumo:
This work covers two aspects. First, it generally compares and summarizes the similarities and differences of state of the art feature detector and descriptor and second it presents a novel approach of detecting intestinal content (in particular bubbles) in capsule endoscopy images. Feature detectors and descriptors providing invariance to change of perspective, scale, signal-noise-ratio and lighting conditions are important and interesting topics in current research and the number of possible applications seems to be numberless. After analysing a selection of in the literature presented approaches, this work investigates in their suitability for applications information extraction in capsule endoscopy images. Eventually, a very good performing detector of intestinal content in capsule endoscopy images is presented. A accurate detection of intestinal content is crucial for all kinds of machine learning approaches and other analysis on capsule endoscopy studies because they occlude the field of view of the capsule camera and therefore those frames need to be excluded from analysis. As a so called “byproduct” of this investigation a graphical user interface supported Feature Analysis Tool is presented to execute and compare the discussed feature detectors and descriptor on arbitrary images, with configurable parameters and visualized their output. As well the presented bubble classifier is part of this tool and if a ground truth is available (or can also be generated using this tool) a detailed visualization of the validation result will be performed.
Resumo:
En aquest projecte presentem un mètode per generar bases de imatges de vianants, requerides per a l'entrenament o validació de sistemes d'aprenentatge basats en exemples, en un entorn virtual. S'ha desenvolupat una plataforma que permet simular una navegació d'una càmara en una escena virtual i recuperar el fluxe de vídeo amb el seu groundtruth. Amb l'ús d'aquesta plataforma es suprimeix el procés d'anotació, necesari per obtenir el groundtruth en entorns reals, i es redueixen els costos al treballar en un entorn virtual.
Resumo:
Este proyecto está destinado a proporcionar herramientas que ayuden en la configuración de cámaras para uso industrial pero también se pueden exportar a otros campos relacionados con el vídeo y la fotografía digital. Las herramientas desarrolladas ayudan a la configuración del balance de blancos, el grado de exposición al que está sometida la escena capturada por la cámara y a calcular el mejor enfoque posible. Además, se ha desarrollado una herramienta que permita al usuario una configuración más cómoda de los parámetros de la cámara. Estos módulos se han desarrollado sobre el software VisionOkII.
Resumo:
El procés de fusió de dues o més imatges de la mateixa escena en una d'única i més gran és conegut com a Image Mosaicing. Un cop finalitzat el procés de construcció d'un mosaic, els límits entre les imatges són habitualment visibles, degut a imprecisions en els registres fotomètric i geomètric. L'Image Blending és l'etapa del procediment de mosaicing a la que aquests artefactes són minimitzats o suprimits. Existeixen diverses metodologies a la literatura que tracten aquests problemes, però la majoria es troben orientades a la creació de panorames terrestres, imatges artístiques d'alta resolució o altres aplicacions a les quals el posicionament de la càmera o l'adquisició de les imatges no són etapes rellevants. El treball amb imatges subaquàtiques presenta desafiaments importants, degut a la presència d'scattering (reflexions de partícules en suspensió) i atenuació de la llum i a condicions físiques extremes a milers de metres de profunditat, amb control limitat dels sistemes d'adquisició i la utilització de tecnologia d'alt cost. Imatges amb il·luminació artificial similar, sense llum global com la oferta pel sol, han de ser unides sense mostrar una unió perceptible. Les imatges adquirides a gran profunditat presenten una qualitat altament depenent de la profunditat, i la seva degradació amb aquest factor és molt rellevant. El principal objectiu del treball és presentar dels principals problemes de la imatge subaquàtica, seleccionar les estratègies més adequades i tractar tota la seqüència adquisició-procesament-visualització del procés. Els resultats obtinguts demostren que la solució desenvolupada, basada en una Estratègia de Selecció de Límit Òptim, Fusió en el Domini del Gradient a les regions comunes i Emfatització Adaptativa d'Imatges amb baix nivell de detall permet obtenir uns resultats amb una alta qualitat. També s'ha proposat una estratègia, amb possibilitat d'implementació paral·lela, que permet processar mosaics de kilòmetres d'extensió amb resolució de centímetres per píxel.
Resumo:
En aquest projecte s'ha dissenyat i simulat una càmera d'ones mil·limètriques mitjançant "Spinning Reflectors" amb l'objectiu d'estudiar la qualitat de les imatges obtingudes, així com determinar la configuració de reflectors acceptable per a la nostra càmera. Per al seu disseny, s'ha realitzat el model d'una antena Cassegrain amb botzina alimentadora a FEKO i s'han simulat els diagrames de radiació corresponents als diferents angles de rotació d'ambdós reflectors al voltant de l'eix en el qual estan situats. Finalment, a partir del principi de funcionament de la nostra càmera, s'ha exposat la seva implementació física i s'ha representat en Matlab la seva PSF (Point Spread Function) i la imatge d'un objecte arbitrari d'acord amb les tècniques de formació d'imatges.
Resumo:
Aquest projecte resol les fases inicials d'un altre projecte més gran que té com a objectiu la conversió automàtica de seqüències d'imatges a 3D. El projecte s'ha centrat en la reconstrucció calibrada de col·leccions d'imatges mitjançant la tècnica anomenada structure from motion. Aquesta tècnica forma part de l'àmbit de la visió per computador i s'utilitza per obtenir la posició i l'orientació de les diferents càmeres juntament amb una reconstrucció 3D de l'escena en forma de núvol de punts.
Resumo:
Purpose: To phenotype a large 3 generation Swiss family with pattern dystrophy and to report a successful result of treatment with ranibizumab of a subfoveal choroidal neovascularisation (CNV) associated with pattern dystrophy in 1 patient Patients and methods: 4 affected and 3 unaffected patients (3 female 4 male, age range: 19 - 80 years) were assessed with a complete ophthalmologic examination. AF images were taken using Heidelberg Retina Angiograph and the digital color photos, fluorescein angiogragraphy (FFA) using the same TOPCON 501 camera. Electroretinogram (full-field and multifocal) was performed in 1 affected patient. One 48 years old patient developed a subfoveal CNV, which was treated with 2 injections of ranibizumab, at 3 months interval. Blood sample was taken for molecular analysis (screening of the gene RDS). Results: Two patients had a typical fundoscopic appearance of pattern dystrophy with butterfly shaped deposit at the fovea and some peripheral flecks, as shown with AF imaging.. Two others affected patients had a more unusual appearance with some macular atrophy in one or both eyes, surrounded by flecks. The visual acuity ranged from 1.0 to 0.1 according to Snellen EDTRS chart. The patient with subfoveal CNV presented a drop of vision form 1.0 to 0.6 within 10 days prior to the diagnosis and also reported some metamorphopsia. FFA and optical computerized tomography (OCT) confirmed a classic CNV. After the 1st injection her vision improved to 1.0 but persistent metamorphopsia and fluid on OCT motivated a second injection. One month after the second injection the OCT was flat and the patient had no symptoms. The results of RDS screening will be presented at the meeting. Conclusion: We present a family with pattern dystrophy, with some members having an unusual fundus appearance, which was mistaken for an early onset dry AMD. The AF imaging is a useful tool in diagnosing this condition. A CNV associated with pattern dystrophy a rare. This is the first report of a successful treatment of the CNV with anti-VEGF intravitreal injections.
Resumo:
Since the early nineties, several hundreds of Chinese immigrants have settled in what has become known as the 'Chinese wholesalers area'. For the past two years, Chinese wholesalers in Aubervilliers have been calling on public authorities to address the problem of street robberies and violent thefts, which they experience on a daily basis. Yet, they have been encouraged by the authorities to ensure their own protection, by - amongst other things - installing surveillance cameras to film the streets. This is illegal according to French legislation on camera surveillance. Knowing this, why have surveillance cameras been adopted as a solution? This question guides the ethnographic analysis presented here of a situation where the installation of surveillance cameras was locally negotiated by the main actors involved - namely, the wholesalers' representatives and the police.
Resumo:
Purpose: Recently morphometric measurements of the ascending aorta have been done with ECG-gated MDCT to help the development of future endovascular therapies (TCT) [1]. However, the variability of these measurements remains unknown. It will be interesting to know the impact of CAD (computer aided diagnosis) with automated segmentation of the vessel and automatic measurements of diameter on the management of ascending aorta aneurysms. Methods and Materials: Thirty patients referred for ECG-gated CT thoracic angiography (64-row CT scanner) were evaluated. Measurements of the maximum and minimum ascending aorta diameters were obtained automatically with a commercially available CAD and semi-manually by two observers separately. The CAD algorithms segment the iv-enhanced lumen of the ascending aorta into perpendicular planes along the centreline. The CAD then determines the largest and the smallest diameters. Both observers repeated the automatic measurements and the semimanual measurements during a different session at least one month after the first measurements. The Bland and Altman method was used to study the inter/intraobserver variability. A Wilcoxon signed-rank test was also used to analyse differences between observers. Results: Interobserver variability for semi-manual measurements between the first and second observers was between 1.2 to 1.0 mm for maximal and minimal diameter, respectively. Intraobserver variability of each observer ranged from 0.8 to 1.2 mm, the lowest variability being produced by the more experienced observer. CAD variability could be as low as 0.3 mm, showing that it can perform better than human observers. However, when used in nonoptimal conditions (streak artefacts from contrast in the superior vena cava or weak lumen enhancement), CAD has a variability that can be as high as 0.9 mm, reaching variability of semi-manual measurements. Furthermore, there were significant differences between both observers for maximal and minimal diameter measurements (p<0.001). There was also a significant difference between the first observer and CAD for maximal diameter measurements with the former underestimating the diameter compared to the latter (p<0.001). As for minimal diameters, they were higher when measured by the second observer than when measured by CAD (p<0.001). Neither the difference of mean minimal diameter between the first observer and CAD nor the difference of mean maximal diameter between the second observer and CAD was significant (p=0.20 and 0.06, respectively). Conclusion: CAD algorithms can lessen the variability of diameter measurements in the follow-up of ascending aorta aneurysms. Nevertheless, in non-optimal conditions, it may be necessary to correct manually the measurements. Improvements of the algorithms will help to avoid such a situation.
Resumo:
We describe the preparation of the modified chelator aminooxyacetyl-ferrioxamine, and the replacement of its iron atom by 67Ga at high specific activity. The aminooxy function of this compound was allowed to react with the aldehyde groups generated by the periodate oxidation of the oligosaccharide of a mouse IgG1 monoclonal antibody (MAb) directed against carcino-embryonic antigen (CEA). The use of the aminooxy group allowed a stable bond to be formed between the chelon and the antibody with no need for reduction. Iron was removed from the ferrioxamine moiety and replaced by 67Ga either before or after conjugation of the chelon to the antibody. In either case the labelled antibody was injected into nude mice bearing a human colon carcinoma having the appropriate antigenicity. Unoxidized antibody, labelled with 125I by conventional methods, was co-injected as an internal control. Additional control experiments were carried out with a non-immune IgG using the same 67Ga-labelled modified chelon as above. The in vivo distribution of the modified antibodies was evaluated at various times between 24 and 96 hr after injection. The methods used were gamma-camera imaging and, more quantitatively, gamma-counting of the various organs after dissection. Interestingly, with the metal-chelon-labelled antibody, the intensity and specificity of tumor labelling was comparable and in some cases superior to the results obtained with radio-iodinated antibody. In particular, there was almost no increase in liver and spleen uptake of radioactive metal relative to radio-iodine, contrary to what has been observed with most antibodies labelled with 111In after conjugation with DTPA.
Resumo:
OBJECTIVE: To weight the rod-, cone-, and melanopsin-mediated activation of the retinal ganglion cells, which drive the pupil light reflex by varying the light stimulus wavelength, intensity, and duration. DESIGN: Experimental study. PARTICIPANTS: Forty-three subjects with normal eyes and 3 patients with neuroretinal visual loss. METHODS: A novel stimulus paradigm was developed using either a long wavelength (red) or short wavelength (blue) light given as a continuous Ganzfeld stimulus with stepwise increases over a 2 log-unit range. The pupillary movement before, during, and after the light stimulus was recorded in real time with an infrared illuminated video camera. MAIN OUTCOME MEASURES: The percent pupil contraction of the transient and sustained pupil response to a low- (1 cd/m(2)), medium- (10 cd/m(2)), and high-intensity (100 cd/m(2)) red- and blue-light stimulus was calculated for 1 eye of each subject. From the 43 normal eyes, median and 25th, 75th, 5th, and 95th percentile values were obtained for each stimulus condition. RESULTS: In normal eyes at lower intensities, blue light evoked much greater pupil responses compared with red light when matched for photopic luminance. The transient pupil contraction was generally greater than the sustained contraction, and this disparity was greatest at the lowest light intensity and least apparent with bright (100 cd/m(2)) blue light. A patient with primarily rod dysfunction (nonrecordable scotopic electroretinogram) showed significantly reduced pupil responses to blue light at lower intensities. A patient with achromatopsia and an almost normal visual field showed selective reduction of the pupil response to red-light stimulation. A patient with ganglion cell dysfunction owing to anterior ischemic optic neuropathy demonstrated global loss of pupil responses to red and blue light in the affected eye. CONCLUSIONS: Pupil responses that differ as a function of light intensity and wavelength support the hypothesis that selected stimulus conditions can produce pupil responses that reflect phototransduction primarily mediated by rods, cones, or melanopsin. Use of chromatic pupil responses may be a novel way to diagnose and monitor diseases affecting either the outer or inner retina.
Performance on a Virtual Reality Angled Laparoscope Task Correlates with Spatial Ability of Trainees
Resumo:
The aim of the present study was to investigate whether trainees' performance on a virtual reality angled laparoscope navigation task correlates with scores obtained on a validated conventional test of spatial ability. 56 participants of a surgery workshop performed an angled laparoscope navigation task on the Xitact LS 500 virtual reality Simulator. Performance parameters were correlated with the score of a validated paper-and-pencil test of spatial ability. Performance at the conventional spatial ability test significantly correlated with performance at the virtual reality task for overall task score (p < 0.001), task completion time (p < 0.001) and economy of movement (p = 0.035), not for endoscope travel speed (p = 0.947). In conclusion, trainees' performance in a standardized virtual reality camera navigation task correlates with their innate spatial ability. This VR session holds potential to serve as an assessment tool for trainees.