958 resultados para reliability measurement
Resumo:
PURPOSE: To evaluate the effects of recent advances in magnetic resonance imaging (MRI) radiofrequency (RF) coil and parallel imaging technology on brain volume measurement consistency. MATERIALS AND METHODS: In all, 103 whole-brain MRI volumes were acquired at a clinical 3T MRI, equipped with a 12- and 32-channel head coil, using the T1-weighted protocol as employed in the Alzheimer's Disease Neuroimaging Initiative study with parallel imaging accelerations ranging from 1 to 5. An experienced reader performed qualitative ratings of the images. For quantitative analysis, differences in composite width (CW, a measure of image similarity) and boundary shift integral (BSI, a measure of whole-brain atrophy) were calculated. RESULTS: Intra- and intersession comparisons of CW and BSI measures from scans with equal acceleration demonstrated excellent scan-rescan accuracy, even at the highest acceleration applied. Pairs-of-scans acquired with different accelerations exhibited poor scan-rescan consistency only when differences in the acceleration factor were maximized. A change in the coil hardware between compared scans was found to bias the BSI measure. CONCLUSION: The most important findings are that the accelerated acquisitions appear to be compatible with the assessment of high-quality quantitative information and that for highest scan-rescan accuracy in serial scans the acquisition protocol should be kept as consistent as possible over time. J. Magn. Reson. Imaging 2012;36:1234-1240. ©2012 Wiley Periodicals, Inc.
Resumo:
We performed a pilot study to compare vertebral fracture assessments (VFA) and lateral X-rays in terms of inter- and intraobserver reliability and degree of correlation for the detection of syndesmophytes in ankylosing spondylitis (AS). We recruited 19 patients with AS and recent lumbar or cervical lateral X-rays with at least one syndesmophyte. Each patient underwent dual-energy X-ray absorptiometry with measurement of bone mineral density and dorso-lumbar VFA. Intra- and interreader reliability for VFA and X-rays were measured using 2 independent, blinded observers and Cohen's kappa values. An adapted modified Stoke Ankylosing Spondylitis Spinal Score (amSASSS) was generated with each method, and these 2 values correlated. For X-rays, intraobserver and interobserver agreement were 94.3% (κ = 0.83) and 98.6% (κ = 0.96), respectively; for VFA, corresponding values were 92.8% (κ = 0.79) and 93.8% (κ = 0.82). Overall agreement between the 2 techniques was 88.6% (κ = 0.72). The Pearson correlation coefficient for the 2 methods was 0.95 for the modified Stoke Ankylosing Spondylitis Spinal Score . Per dual-energy X-ray absorptiometry-generated bone mineral density, >50% of patients were osteopenic and 10% osteoporotic. In terms of reproducibility and correlation with X-rays, performing a VFA appears to be a candidate for assessing radiographic damage in AS, thought further research is necessary to justify this indication.
Resumo:
Background: Urinary human chorionic gonadotropin (hCG) concentration is routinely measured in all anti-doping laboratories to exclude the misuse of recombinant or urinary hCG preparations. In this study, extended validation of two commercial immunoassays for hCG measurements in urine was performed. Both tests were initially designed for hCG determination in human serum/plasma. Methods: Access (R) and Elecsys (R) 1010 are two automated immunoanalysers for central laboratories. The limits of detection and quantification, as well as intra-laboratory and inter-technique correlation, precision, and accuracy, were determined. Stability studies of hCG in urine following freezing and thawing cycles (n = 3) as well as storage conditions at room temperature, 4 degrees C and 20 degrees C, were performed. Results: Statistical evaluation of hCG concentrations in male urine samples (n = 2429) measured with the Elecsys (R) 1010 system enabled us to draw a skewed frequency histogram and establish a far outside value equal to 2.3 IU/L. This decision limit corresponds to the concentration at which a sportsman will be considered positive for hCG. Intra-assay precision for the Access (R) analyser was less than 4.0 A, whereas the inter-assay precision was closer to 4.5 % (concentrations of the official external controls contained between 5.5 and 195.0 IU/L). Intra and inter-assay precision for the Elecsys (R) 1010 analyser was slightly better. A good inter-technique correlation was obtained when measuring various urine samples (male and female). No urinary hCG loss was observed after two freeze/thaw cycles. On the other hand, time and inappropriate storage conditions, such as temperatures above 10 degrees C for more than 5 days, can deteriorate urinary hCG. Conclusions: Both analysers showed acceptable performances and are suitable for screening urine for anti-doping analyses. Each laboratory should validate and establish its own reference values because hCG concentrations measured in urine can be different from one immunoassay to another. The time delay between urine collection and analysis should be reduced as much as possible, and urine samples should be transported in optimal conditions to avoid a loss of hCG immunoreactivity.
Resumo:
The Pulmonary Embolism Severity Index (PESI) is a validated clinical prognostic model for patients with acute pulmonary embolism (PE). Our goal was to assess the PESI's inter-rater reliability in patients diagnosed with PE. We prospectively identified consecutive patients diagnosed with PE in the emergency department of a Swiss teaching hospital. For all patients, resident and attending physician raters independently collected the 11 PESI variables. The raters then calculated the PESI total point score and classified patients into one of five PESI risk classes (I-V) and as low (risk classes I/II) versus higher-risk (risk classes III-V). We examined the inter-rater reliability for each of the 11 PESI variables, the PESI total point score, assignment to each of the five PESI risk classes, and classification of patients as low versus higher-risk using kappa (κ) and intra-class correlation coefficients (ICC). Among 48 consecutive patients with an objective diagnosis of PE, reliability coefficients between resident and attending physician raters were > 0.60 for 10 of the 11 variables comprising the PESI. The inter-rater reliability for the PESI total point score (ICC: 0.89, 95% CI: 0.81-0.94), PESI risk class assignment (κ: 0.81, 95% CI: 0.66-0.94), and the classification of patients as low versus higher-risk (κ: 0.92, 95% CI: 0.72-0.98) was near perfect. Our results demonstrate the high reproducibility of the PESI, supporting the use of the PESI for risk stratification of patients with PE.
Resumo:
The Irish Government in March 2008 set a target to identify measure and reduce the Administrative Burden (AB) of domestic regulation for businesses by 25% by the end of 2012 – on foot of a European Council invitation to all member states in March 2007. As part of a cross-Government process led by the Business Regulation Unit of the Department of Jobs, Enterprise and Innovation (DJEI), the Department of Health carried out a measurement exercise in 2012 on the main Information Obligations placed on business by legislation in the areas of Food, Nursing Homes and Pharmacy sectors.The AB baseline measurement for those information obligations is described in this report. Click here to download PDF 322KB Â
Resumo:
BACKGROUND: Self-administered, general health risk screening questionnaires that are administered while patients wait in the doctor's office may be a reasonable and timesaving approach to address the requirements of preventive medicine in a typical 10-min medical visit. The psychometric characteristics of the Alcohol Use Disorders Identification Test (AUDIT) incorporated within a health questionnaire (H-AUDIT) have not been examined. METHODS: The reliability and validity of the self-administered AUDIT were compared between the H-AUDIT and the AUDIT used as a single scale (S-AUDIT) in 332 primary care patients. RESULTS: No major demographic or alcohol use characteristics were found between the 166 subjects who completed the H-AUDIT and the 166 individuals who completed the S-AUDIT. The test-retest reliability of the 166 subjects who completed the H-AUDIT [estimated by Spearman correlation coefficient at a 6-week interval (0.88), internal consistency (total correlation coefficients for all items ranged from 0.38 to 0.69; Cronbach alpha index 0.85), and the sensitivity and specificity of the H-AUDIT were used to identify at-risk drinkers' areas under receiver operating characteristic (0.77) and alcohol-dependent subjects' areas under receiver operating characteristic (0.89)] was similar to the same measurements obtained with the 166 individuals who completed the S-AUDIT. CONCLUSIONS: The AUDIT incorporated in a health risk screening questionnaire is a reliable and valid self-administered instrument to identify at-risk drinkers and alcohol-dependent individuals in primary care settings.
Resumo:
We report on advanced dual-wavelength digital holographic microscopy (DHM) methods, enabling single-acquisition real-time micron-range measurements while maintaining single-wavelength interferometric resolution in the nanometer regime. In top of the unique real-time capability of our technique, it is shown that axial resolution can be further increased compared to single-wavelength operation thanks to the uncorrelated nature of both recorded wavefronts. It is experimentally demonstrated that DHM topographic investigation within 3 decades measurement range can be achieved with our arrangement, opening new applications possibilities for this interferometric technique. ©2008 COPYRIGHT SPIE
Resumo:
The medulla oblongata (MO) contains a high density of glycinergic synapses and a particularly high concentration of glycine. The aims of this study were to measure directly in vivo the neurochemical profile, including glycine, in MO using a spin-echo-based (1)H MRS sequence at TE?=?2.8 ms and to compare it with three other brain regions (cortex, striatum and hippocampus) in the rat. Glycine was quantified in MO at TE?=?2.8 ms with a Cramér-Rao lower bound (CRLB) of approximately 5%. As a result of the relatively low level of glycine in the other three regions, the measurement of glycine was performed at TE?=?20 ms, which provides a favorable J-modulation of overlapping myo-inositol resonance. The other 14 metabolites composing the neurochemical profile were quantified in vivo in MO with CRLBs below 25%. Absolute concentrations of metabolites in MO, such as glutamate, glutamine, ?-aminobutyrate, taurine and glycine, were in the range of previous in vitro quantifications in tissue extracts. Compared with the other regions, MO had a three-fold higher glycine concentration, and was characterised by reduced (p?<?0.001) concentrations of glutamate (-50?±?4%), glutamine (-54?±?3%) and taurine (-78?±?3%). This study suggests that the functional specialisation of distinct brain regions is reflected in the neurochemical profile.
Resumo:
The purpose of this study was to assess the validity of two common methods used to assess energy intake. A 3-day weighed dietary record and a dietary history were collected and compared with the total daily energy expenditure (TEE) assessed by the heart rate method in a group of 12 obese and 12 nonobese prepubertal children (mean age 9.3 +/- 1.1 years vs 9.3 +/- 0.4 years). The TEE value was higher in obese than in nonobese children (9.89 +/- 1.08 vs 8.13 +/- 1.39 MJ/day; p < 0.01). Energy intake assessed by the dietary record was significantly lower than TEE in the obese children (7.06 +/- 0.98 MJ/day; p < 0.001) but comparable to TEE in the nonobese children (8.03 +/- 0.99 MJ/day; p = not significant). Energy intake assessed by diet history was lower than TEE in the obese children (8.37 +/- 1.35 MJ/day, p < 0.05) but close to TEE in the nonobese children (8.64 +/- 1.54 MJ/day, p = not significant). These results suggest that obese children underreport food intake and that the dietary record and the diet history are not valid means of assessing energy intake in obese prepubertal children.
Resumo:
Primary cultures of cardiomyocytes represent a useful model for analyzing cardiac cell biology as well as pathogenesis of several cardiovascular disorders. Our aim was to standardize protocols for determining the damage of cardiac cells cultured in vitro by measuring the creatine kinase and its cardiac isotype and lactate dehydrogenase activities in the supernatants of mice cardiomyocytes submitted to different protocols of cell lysis. Our data showed that due to its higher specificity, the cardiac isotype creatine kinase was the most sensitive as compared to the others studied enzymatic markers, and can be used to monitor and evaluate cardiac damage in in vitro assays.
Resumo:
The purpose of this study was to evaluate the factor structure and the reliability of the French versions of the Identity Style Inventory (ISI-3) and the Utrecht-Management of Identity Commitments Scale (U-MICS) in a sample of college students (N = 457, 18 to 25 years old). Confirmatory factor analyses confirmed the hypothesized three-factor solution of the ISI-3 identity styles (i.e. informational, normative, and diffuse-avoidant styles), the one-factor solution of the ISI-3 identity commitment, and the three-factor structure of the U-MICS (i.e. commitment, in-depth exploration, and reconsideration of commitment). Additionally, theoretically consistent and meaningful associations among the ISI-3, U-MICS, and Ego Identity Process Questionnaire (EIPQ) confirmed convergent validity. Overall, the results of the present study indicate that the French versions of the ISI-3 and UMICS are useful instruments for assessing identity styles and processes, and provide additional support to the cross-cultural validity of these tools.
Resumo:
Leaders must scan the internal and external environment, chart strategic and task objectives, and provide performance feedback. These instrumental leadership (IL) functions go beyond the motivational and quid-pro quo leader behaviors that comprise the full-range-transformational, transactional, and laissez faire-leadership model. In four studies we examined the construct validity of IL. We found evidence for a four-factor IL model that was highly prototypical of good leadership. IL predicted top-level leader emergence controlling for the full-range factors, initiating structure, and consideration. It also explained unique variance in outcomes beyond the full-range factors; the effects of transformational leadership were vastly overstated when IL was omitted from the model. We discuss the importance of a "fuller full-range" leadership theory for theory and practice. We also showcase our methodological contributions regarding corrections for common method variance (i.e., endogeneity) bias using two-stage least squares (2SLS) regression and Monte Carlo split-sample designs.
Resumo:
Introduction: Clinical symptoms and degree of spinal stenosis based on cross sectional dural sac area correlate only weakly in lumbar spinal stenosis (LSS) patients. We conceived a four grade classification system (A, B, C & D) based on the morphology of the dural sac and its contents as seen on T2 axial MRI images. The categories take into account the rootlet/CSF ratio. We applied this grading to three patient groups: LSS scheduled for surgery; LSS following conservative treatment and patients with low back pain (LBP) without leg pain. Materials/Methods: A total of 346 T2 axial MRI images taken from LSS and LBP patients were included in this retroperspective study. 37 patients had decompressive surgery (132 MRI images), 31 conservative treatment (116 MRI images) and 27 patients had unspecific LBP (98 MRI images). Dural sac cross-sectional surface area and morphological grading of the canal were measured digitally both at disc and pedicle level. Intra- and inter-observer reliability were assessed (weighted Cohen's kappa statistics) from 50 MRI images taken from the surgery group. Results: At the most severe disc level, grade A (mild stenosis) was found in 3% of MRI images of the surgical group as opposed to 51% in the conservatively treated group and 85% in the LBP group. Grade B occurred in 8% of the surgical, 20% of the conservative and was negligible in LBP group (below 1%). Grade C and D (severe stenosis) was found in 89% of the surgical group, as opposed to 30% in conservative group and 11% in LBP group. The grades of all groups were comparable at the pedicle levels, exhibiting in 94% a grade A with a maximum at the A1 grade. Pedicle and disc level cross-sectional area were smallest in the surgery group and smaller in the conservative group as compared to the LBP group at the levels L2, L3 and L4. According to cross-sectional area measurements patients from the surgery group seems to have smaller vertebral canal although this was not related to smaller stature. Validation of grading: Average intra-and inter observer kappas were 0.76 and 0.69 respectively, for physicians working in the study originating institution. Combining all observers the kappa values were 0.57 +/- 0.19. and 0.44 +/- 0.19 respectively. Dural sac cross-sectional area measurements showed no statistically significant differences between observers. Conclusion: Since no specific measurement tools are needed the grading suits everyday clinical practice and favours communication of degree of stenosis between practising physicians. In our institution Grade A stenosis was less likely to require surgical treatment. This grading can therefore be an aid in surgical patient selection in teaching units.
Resumo:
This SEPHO handbook primarily focuses on the measurement and interpretation of health inequalities. Written by Roy Carr-Hill and Paul Chalmers-Dixon of York University, it provides a comprehensive collection of material for those concerned to document and understand health inequalities.