995 resultados para pulse-echo technique


Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Congenital cardiopathies in adults are a rare clinical entity in the cardiology consultations. Advances in imaging techniques allow the fortuitous diagnosis of mild forms of these congenital abnormalities. We describe a case of an asymptomatic 41-year-old man, with a medical history of recurrent pneumonia during childhood and an established diagnosis of scimitar syndrome by computed tomography.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Arteriovenous malformations (AVMs) may be cured by injecting liquid embolic agents such as Onyx. Reflux, however, can sometimes be difficult to control and may jeopardize a complete embolization. The pressure cooker technique (PCT) was designed to create an anti-reflux plug by trapping the detachable part of an Onyx-compatible microcatheter with coils and glue in order to obtain wedge-flow conditions, thereby enabling a better understanding of macrofistulous AVMs and a more comprehensive, forceful and controlled Onyx embolization. The PCT might enlarge the range of AVMs amenable to endovascular cure. Three illustrative cases are presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives. The goal of this study is to evaluate a T2-mapping sequence by: (i) measuring the reproducibility intra- and inter-observer variability in healthy volunteers in two separate scanning session with a T2 reference phantom; (2) measuring the mean T2 relaxation times by T2-mapping in infarcted myocardium in patients with subacute MI and compare it with patient's the gold standard X-ray coronary angiography and healthy volunteers results. Background. Myocardial edema is a consequence of an inflammation of the tissue, as seen in myocardial infarct (MI). It can be visualized by cardiovascular magnetic resonance (CMR) imaging using the T2 relaxation time. T2-mapping is a quantitative methodology that has the potential to address the limitation of the conventional T2-weighted (T2W) imaging. Methods. The T2-mapping protocol used for all MRI scans consisted in a radial gradient echo acquisition with a lung-liver navigator for free-breathing acquisition and affine image registration. Mid-basal short axis slices were acquired.T2-maps analyses: 2 observers semi- automatically segmented the left ventricle in 6 segments accordingly to the AHA standards. 8 healthy volunteers (age: 27 ± 4 years; 62.5% male) were scanned in 2 separate sessions. 17 patients (age : 61.9 ± 13.9 years; 82.4% male) with subacute STEMI (70.6%) and NSTEMI underwent a T2-mapping scanning session. Results. In healthy volunteers, the mean inter- and intra-observer variability over the entire short axis slice (segment 1 to 6) was 0.1 ms (95% confidence interval (CI): -0.4 to 0.5, p = 0.62) and 0.2 ms (95% CI: -2.8 to 3.2, p = 0.94, respectively. T2 relaxation time measurements with and without the correction of the phantom yielded an average difference of 3.0 ± 1.1 % and 3.1 ± 2.1 % (p = 0.828), respectively. In patients, the inter-observer variability in the entire short axis slice (S1-S6), was 0.3 ms (95% CI: -1.8 to 2.4, p = 0.85). Edema location as determined through the T2-mapping and the coronary artery occlusion as determined on X-ray coronary angiography correlated in 78.6%, but only in 60% in apical infarcts. All except one of the maximal T2 values in infarct patients were greater than the upper limit of the 95% confidence interval for normal myocardium. Conclusions. The T2-mapping methodology is accurate in detecting infarcted, i.e. edematous tissue in patients with subacute infarcts. This study further demonstrated that this T2-mapping technique is reproducible and robust enough to be used on a segmental basis for edema detection without the need of a phantom to yield a T2 correction factor. This new quantitative T2-mapping technique is promising and is likely to allow for serial follow-up studies in patients to improve our knowledge on infarct pathophysiology, on infarct healing, and for the assessment of novel treatment strategies for acute infarctions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Au cours des deux dernières décennies, la technique d'imagerie arthro-scanner a bénéficié de nombreux progrès technologiques et représente aujourd'hui une excellente alternative à l'imagerie par résonance magnétique (IRM) et / ou arthro-IRM dans l'évaluation des pathologies de la hanche. Cependant, elle reste limitée par l'exposition aux rayonnements ionisants importante. Les techniques de reconstruction itérative (IR) ont récemment été mis en oeuvre avec succès en imagerie ; la littérature montre que l'utilisation ces dernières contribue à réduire la dose d'environ 40 à 55%, comparativement aux protocoles courants utilisant la rétroprojection filtrée (FBP), en scanner de rachis. A notre connaissance, l'utilisation de techniques IR en arthro-scanner de hanche n'a pas été évaluée jusqu'à présent. Le but de notre étude était d'évaluer l'impact de la technique ASIR (GE Healthcare) sur la qualité de l'image objective et subjective en arthro-scanner de hanche, et d'évaluer son potentiel en terme de réduction de dose. Pour cela, trente sept patients examinés par arthro-scanner de hanche ont été randomisés en trois groupes : dose standard (CTDIvol = 38,4 mGy) et deux groupes de dose réduite (CTDIvol = 24,6 ou 15,4 mGy). Les images ont été reconstruites en rétroprojection filtrée (FBP) puis en appliquant différents pourcentages croissants d'ASIR (30, 50, 70 et 90%). Le bruit et le rapport contraste sur bruit (CNR) ont été mesurés. Deux radiologues spécialisés en imagerie musculo-squelettique ont évalué de manière indépendante la qualité de l'image au niveau de plusieurs structures anatomiques en utilisant une échelle de quatre grades. Ils ont également évalué les lésions labrales et du cartilage articulaire. Les résultats révèlent que le bruit augmente (p = 0,0009) et le CNR diminue (p = 0,001) de manière significative lorsque la dose diminue. A l'inverse, le bruit diminue (p = 0,0001) et le contraste sur bruit augmente (p < 0,003) de manière significative lorsque le pourcentage d'ASIR augmente ; on trouve également une augmentation significative des scores de la qualité de l'image pour le labrum, le cartilage, l'os sous-chondral, la qualité de l'image globale (au delà de ASIR 50%), ainsi que le bruit (p < 0,04), et une réduction significative pour l'os trabuculaire et les muscles (p < 0,03). Indépendamment du niveau de dose, il n'y a pas de différence significative pour la détection et la caractérisation des lésions labrales (n=24, p = 1) et des lésions cartilagineuses (n=40, p > 0,89) en fonction du pourcentage d'ASIR. Notre travail a permis de montrer que l'utilisation de plus de 50% d'ASIR permet de reduire de manière significative la dose d'irradiation reçue par le patient lors d'un arthro-scanner de hanche tout en maintenant une qualité d'image diagnostique comparable par rapport à un protocole de dose standard utilisant la rétroprojection filtrée.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

There is controversy over the use of the Ross procedure with regard to the sub-coronary and root replacement technique and its long-term durability. A systematic review of the literature may provide insight into the outcomes of these two surgical subvariants. A systematic review of reports between 1967 and February 2013 on sub-coronary and root replacement Ross procedures was undertaken. Twenty-four articles were included and divided into (i) sub-coronary technique and (ii) root replacement technique. The 10-year survival rate for a mixed-patient population in the sub-coronary procedure was 87.3% with a 95% confidence interval (CI) of 79.7-93.4 and 89.1% (95% CI, 85.3-92.1) in the root replacement technique category. For adults, it was 94 vs 95.3% (CI, 88.9-98.1) and in the paediatric series it was 90 vs 92.7% (CI, 86.9-96.0), respectively. Freedom from reoperation at 10 years was, in the mixed population, 83.3% (95% CI, 69.9-93.4) and 93.3% (95% CI, 89.4-95.9) for sub-coronary versus root replacement technique, respectively. In adults, it was 98 vs 91.2% (95% CI, 82.4-295.8), and in the paediatric series 93.3 vs 92.0% (95% CI, 86.1-96.5) for sub-coronary versus root replacement technique, respectively. The Ross procedure arguably has satisfactory results over 5 and 10 years for both adults and children. The results do not support the advantages of the sub-coronary technique over the root replacement technique. Root replacement was of benefit to patients undergoing reoperations on neoaorta and for long-term survival in mixed series.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aortic stiffness is an independent predictor factor for cardiovascular risk. Different methods for determining pulse wave velocity (PWV) are used, among which the most common are mechanical methods such as SphygmoCor or Complior, which require specific devices and are limited by technical difficulty in obtaining measurements. Doppler guided by 2D ultrasound is a good alternative to these methods. We studied 40 patients (29 male, aged 21 to 82 years) comparing the Complior method with Doppler. Agreement of both devices was high (R = 0.91, 0.84-0.95, 95% CI). The reproducibility analysis revealed no intra-nor interobserver differences. Based on these results, we conclude that Doppler ultrasound is a reliable and reproducible alternative to other established methods for themeasurement of aortic PWV

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the present work, microstructure improvement using FSP (Friction Stir Processing) is studied. In the first part of the work, the microstructure improvement of as-cast A356 is demonstrated. Some tensile tests were applied to check the increase in ductility. However, the expected results couldn’t be achieved. In the second part, the microstructure improvement of a fusion weld in 1050 aluminium alloy is presented. Hardness tests were carried out to prove the mechanical propertyimprovements. In the third and last part, the microstructure improvement of 1050 aluminium alloy is achieved. A discussion of the mechanical property improvements induced by FSP is made. The influence of tool traverse speed on microstructure and mechanical properties is also discussed. Hardness tests and recrystallization theory enabled us to find out such influence

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE.: Injection of opioids to the superior cervical ganglion (SCG) has been reported to provide pain relief in patients suffering from different kinds of neuropathic facial pain conditions, such as trigeminal neuralgia, postherpetic neuralgia, and atypical facial pain. The classic approach to the SCG is a transoral technique using a so-called "stopper" to prevent accidental carotid artery puncture. The main disadvantage of this technique is that the needle tip is positioned distant from the actual target, possibly impeding successful block of the SCG. A further limitation is that injection of local anesthetics due to potential carotid artery puncture is contraindicated. We hypothesized that the SCG can be identified and blocked using ultrasound imaging, potentially increasing precision of this technique. INTERVENTIONS.: In this pilot study, 20 US-guided simulated blocks of the SCG were performed in 10 human cadavers in order to determine the accuracy of this novel block technique. After injection of 0.1 mL of dye, the cadavers were dissected to evaluate the needle position and coloring of the SCG. RESULTS.: Nineteen of the 20 needle tips were located in or next to the SCG. This corresponded to a simulated block success rate of 95% (95% confidence interval 85-100%). In 17 cases, the SCG was completely colored, and in two cases, the caudal half of the SCG was colored with dye. CONCLUSIONS.: The anatomical dissections confirmed that our ultrasound-guided approach to the SCG is accurate. Ultrasound could become an attractive alternative to the "blind" transoral technique of SCG blocks.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background : Port-related bloodstream infection (PRBSI) is a common complication associated with long-term use of ports systems. Systemic antimicrobial therapy (ST) and removal of the device is the standard management of PRBSI. However, a conservative management combining ST with antibiotic lock therapy (ALT) without port removal has been suggested as an alternative management option for infections due to gram-positive skin colonizers with low virulence.¦Objectives : i) to assess the frequency of management of PRBSI in onco-hematological patients by combining the ALT with ST, without catheter removal and ii) to analyze the efficacy of such an approach.¦Methods : Retrospective observational study over a 6-year period between 2005 and 2010, including patients who where diagnosed with PRBSI and who were treated with ST and ALT. PRBSI diagnosis consisted in clinical signs of bacteremia with blood cultures positive for gram-positive skin colonizers. The primary endpoint was failure to cure the PRBSI.¦Results : 61 port infections were analysed, of which 23 PRBSI met the inclusion criteria. All the patients were suffering from haematological conditions and 75% were neutropenic at the time of PRBSI diagnosis. S. epidermidis was responsible for 91% of PRBSI (21/23). The median duration of ST was 14 days (range 7-35) and the median duration of ALT was 15 days (range 8-41). Failure to cure the PRBSI requiring port removal was observed in 4 patients, but was not associated with severe infectious complications. Kaplan-Meier analysis showed a success rate in port salvage at day 180 (6 months) of 78% (95%CI 59-97%).¦Conclusion : The success rate observed in the present study suggests that combining ST and ALT is an effective option to conservatively treat PRBSI caused by pathogens of low virulence such as S. epidermidis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

RESUMEDurant la phase de récupération d'un exercice de course à pied d'intensité maximale ou submaximale, une augmentation de la pression artérielle systolique centrale (aortique) résultant de la réflexion des ondes de pouls sur l'arbre vasculaire est constatée chez l'individu en bonne santé. En diastole cependant, l'impact de la réflexion de ces ondes de pouls sur la pression centrale demeure inconnu durant la récupération d'un exercice.Nous avons évalué les ondes de pouls centrales systolique et diastolique chez onze athlètes d'endurance durant la phase de récupération d'un exercice de course à pied dans des conditions d'effort maximal (sur tapis de course) et lors d'un effort submaximal lors d'une course à pied de 4000 mètres en plein air sur terrain mixte.Pour chaque sujet et lors des deux exercices, l'onde de pouls a été mesurée au niveau radial par tonométrie d'aplanation durant une phase de repos précédant l'exercice, puis à 5, 15, 25, 35 et 45 minutes après la fin de l'exercice. En utilisant une fonction mathématique de transfert, l'onde de pouls centrale a été extrapolée à partir de l'onde de pouls radiale. En compilant la forme de l'onde de pouls centrale avec une mesure simultanée de la pression artérielle brachiale, un index d'augmentation de l'onde de pouls en systole (Alx) et en diastole (Als) peut être calculé, reflétant l'augmentation des pressions résultant de la réflexion des ondes sur l'arbre vasculaire périphérique.A 5 minutes de la fin de l'exercice, les deux index ont été mesurés moindres que ceux mesurés lors de la phase précédant celui-ci. Lors des mesures suivantes, Alx est resté bas, alors que Aid a progressivement augmenté pour finalement dépasser la valeur de repos après 45 minutes de récupération. Le même phénomène a été constaté pour les deux modalités d'exercice (maximal ou submaximal). Ainsi, au-delà de quelques minutes de récupération après un exercice de course d'intensité maximale ou submaximale, nous avons montré par ces investigations que les ondes de pouls réfléchies en périphérie augmentent de façon sélective la pression centrale en diastole chez l'athlète d'endurance.ABSTRACTDuring recovery from a maximal or submaximal aerobic exercise, augmentation of central (aortic) systolic pressure by reflected pressure waves is blunted in healthy humans. However, the extent to which reflected pressure waves modify the central pulse in diastole in these conditions remains unknown. We evaluated systolic and diastolic central reflected waves in 11 endurance-trained athletes on recovery from a maximal running test on a treadmill (treadmill-max) and a 4000m run in field conditions. On both occasions in each subject, the radial pulse was recorded with applanation tonometry in the resting preexercise state and then 5, 15, 25, 35, and 45 minutes after exercise termination. From the central waveform, as reconstructed by application of a generalized transfer function, we computed a systolic (Alx) and a diastolic index (Aid) of pressure augmentation by reflections. At 5 minutes, both indices were below preexercise. At further time-points, Alx remained low, while Aid progressively increased, to overshoot above preexercise at 45 minutes. The same behavior was observed with both exercise types. Beyond the first few minutes of recovery following either maximal or submaximal aerobic exercise, reflected waves selectively augment the central pressure pulse in diastole, at least in endurance- trained athletes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In vivo localized proton magnetic resonance spectroscopy (1H MRS) became a powerful and unique technique to non-invasively investigate brain metabolism of rodents and humans. The main goal of 1H MRS is the reliable quantification of concentrations of metabolites (neurochemical profile) in a well-defined region of the brain. The availability of very high magnetic field strengths combined with the possibility of acquiring spectra at very short echo time have dramatically increased the number of constituents of the neurochemical profile. The quantification of spectra measured at short echo times is complicated by the presence of macromolecule signals of particular importance at high magnetic fields. An error in the macromolecule estimation can lead to substantial errors in the obtained neurochemical profile. The purpose of the present review is to overview methods of high field 1H MRS with a focus on the metabolite quantification, in particular in handling signals of macromolecules. Three main approaches of handling signals of macromolecules are described, namely mathematical estimation of macromolecules, measurement of macromolecules in vivo, and direct acquisition of the in vivo spectrum without the contribution of macromolecules.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Adenovirus-mediated gene therapy is hampered by severe virus-related toxicity, especially to the liver. The aim of the present study was to test the ability of a vascular exclusion technique to achieve transgene expression within selected liver segments, thus minimizing both viral and transgene product toxicity to the liver. An E1-E3-deleted replication-deficient adenovirus expressing a green fluorescent protein (GFP) reporter gene was injected into the portal vein of BDIX rats, with simultaneous clamping of the portal vein tributaries to liver segments II, III, IV, V, and VIII. GFP expression and inflammatory infiltrate were measured in the different segments of the liver and compared with those of the livers of animals receiving the viral vector in the portal vein without clamping. The GFP expression was significantly higher in the selectively perfused segments of the liver as compared with the non-perfused segments (p < 0.0001) and with the livers of animals that received the vector in the portal vein without clamping (p < 0.0001). Accordingly, the inflammatory infiltrate was more intense in the selectively perfused liver segments as compared with all other groups (p < 0.0001). Fluorescence was absent in lungs and kidneys and minimal in spleen. The clinical usefulness of adenovirus-mediated gene transfer to the liver largely depends on the reduction of its liver toxicity. Clamping of selected portal vein branches during injection allows for delivery of genes of interest to targeted liver segments. Transgene expression confined to selected liver segments may be useful in the treatment of focal liver diseases, including metastases.