997 resultados para pressure equipment


Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND Left ventricular hypertrophy (LVH) is common in kidney transplant (KT) recipients. LVH is associated with a worse outcome, though m-TOR therapy may help to revert this complication. We therefore conducted a longitudinal study to assess morphological and functional echocardiographic changes after conversion from CNI to m-TOR inhibitor drugs in nondiabetic KT patients who had previously received RAS blockers during the follow-up. METHODS We undertook a 1-year nonrandomized controlled study in 30 non-diabetic KT patients who were converted from calcineurin inhibitor (CNI) to m-TOR therapy. A control group received immunosuppressive therapy based on CNIs. Two echocardiograms were done during the follow-up. RESULTS Nineteen patients were switched to SRL and 11 to EVL. The m-TOR group showed a significant reduction in LVMi after 1 year (from 62 ± 22 to 55 ± 20 g/m2.7; P=0.003, paired t-test). A higher proportion of patients showing LVMi reduction was observed in the m-TOR group (53.3 versus 29.3%, P=0.048) at the study end. In addition, only 56% of the m-TOR patients had LVH at the study end compared to 77% of the control group (P=0.047). A significant change from baseline in deceleration time in early diastole was observed in the m-TOR group compared with the control group (P=0.019). CONCLUSIONS Switching from CNI to m-TOR therapy in non-diabetic KT patients may regress LVH, independently of blood pressure changes and follow-up time. This suggests a direct non-hemodynamic effect of m-TOR drugs on cardiac mass.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND Measurement of HbA1c is the most important parameter to assess glycemic control in diabetic patients. Different point-of-care devices for HbA1c are available. The aim of this study was to evaluate two point-of-care testing (POCT) analyzers (DCA Vantage from Siemens and Afinion from Axis-Shield). We studied the bias and precision as well as interference from carbamylated hemoglobin. METHODS Bias of the POCT analyzers was obtained by measuring 53 blood samples from diabetic patients with a wide range of HbA1c, 4%-14% (20-130 mmol/mol), and comparing the results with those obtained by the laboratory method: HPLC HA 8160 Menarini. Precision was performed by 20 successive determinations of two samples with low 4.2% (22 mmol/mol) and high 9.5% (80 mmol/mol) HbA1c values. The possible interference from carbamylated hemoglobin was studied using 25 samples from patients with chronic renal failure. RESULTS The means of the differences between measurements performed by each POCT analyzer and the laboratory method (95% confidence interval) were: 0.28% (p<0.005) (0.10-0.44) for DCA and 0.27% (p<0.001) (0.19-0.35) for Afinion. Correlation coefficients were: r=0.973 for DCA, and r=0.991 for Afinion. The mean bias observed by using samples from chronic renal failure patients were 0.2 (range -0.4, 0.4) for DCA and 0.2 (-0.2, 0.5) for Afinion. Imprecision results were: CV=3.1% (high HbA1c) and 2.97% (low HbA1c) for DCA, CV=1.95% (high HbA1c) and 2.66% (low HbA1c) for Afinion. CONCLUSIONS Both POCT analyzers for HbA1c show good correlation with the laboratory method and acceptable precision.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Critical limb ischemia in diabetic patients is associated with high rates of morbidity and mortality. Suboptimal responses to the available medical and surgical treatments are common in these patients, who also demonstrate limited vascular homeostasis. Neovasculogenesis induced by stem cell therapy could be a useful approach for these patients. Neovasculogenesis and clinical improvement were compared at baseline and at 3 and 12 months after autologous bone marrow-derived mononuclear cell (BMMNC) transplantation in diabetic patients with peripheral artery disease. We conducted a prospective study to evaluate the safety and efficacy of intra-arterial administration of autologous BMMNCs (100-400 × 10(6) cells) in 20 diabetic patients with severe below-the-knee arterial ischemia. Although the time course of clinical effects differed among patients, after 12 months of follow-up all patients presented a notable improvement in the Rutherford-Becker classification, the University of Texas diabetic wound scales, and the Ankle-Brachial Index in the target limb. The clinical outcome was consistent with neovasculogenesis, which was assessed at 3 months by digital subtraction angiography and quantified by MetaMorph software. Unfortunately, local cell therapy in the target limb had no beneficial effect on the high mortality rate in these patients. In diabetic patients with critical limb ischemia, intra-arterial perfusion of BMMNCs is a safe procedure that generates a significant increase in the vascular network in ischemic areas and promotes remarkable clinical improvement.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this review, we discuss genetic evidence supporting Guyton's hypothesis stating that blood pressure control is critically depending on fluid handling by the kidney. The review is focused on the genetic dissection of sodium and potassium transport in the distal nephron and the collecting duct that are the most important sites for the control of sodium and potassium balance by aldosterone and angiotensin II. Thanks to the study of Mendelian forms of hypertension and their corresponding transgenic mouse models, three main classes of diuretic receptors (furosemide, thiazide, amiloride) and the main components of the aldosterone- and angiotensin-dependent signaling pathways were molecularly identified over the past 20years. This will allow to design rational strategies for the treatment of hypertension and for the development of the next generation of diuretics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A four compartment model of the cardiovascular system is developed. To allow for easy interpretation and to minimise the number of parameters, an effort was made to keep the model as simple as possible. A sensitivity analysis is first carried out to determine which are the most important model parameters to characterise the blood pressure signal. A four stage process is then described which accurately determines all parameter values. This process is applied to data from three patients and good agreement is shown in all cases.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: An inverse relationship between blood pressure (BP) and cognitive function has been found in adults, but limited data are available in adolescents and young adults. We examined the prospective relation between BP and cognitive function in adolescence. METHODS: We examined the association between BP measured at the ages of 12-15 years in school surveys and cognitive endpoints measured in the Seychelles Child Development Study at ages 17 (n = 407) and 19 (n = 429) years, respectively. We evaluated multiple domains of cognition based on subtests of the Cambridge Neurological Test Automated Battery (CANTAB), the Woodcock Johnson Test of Scholastic Achievement (WJTA), the Finger Tapping test (FT) and the Kaufman Brief Intelligence Test (K-BIT). We used age, sex and height-specific z-scores of SBP, DBP and mean arterial pressure (MAP). RESULTS: Six out of the 21 cognitive endpoints tested were associated with BP. However, none of these associations were found to hold for both males and females or for different subtests within the same neurodevelopmental domain or for both SBP and DBP. Most of these associations disappeared when analyses were adjusted for selected potential confounding factors such as socio-economic status, birth weight, gestational age, BMI, alcohol consumption, blood glucose, and total n-3 and n-6 polyunsaturated fats. CONCLUSIONS: Our findings do not support a consistent association between BP and subsequent performance on tests assessing various cognitive domains in adolescents.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Peer pressure is regarded as an important determinant of substance use, sexual behavior and juvenile delinquency. However, few peer pressure scales are validated, especially in French or German. Little is known about the factor structure of such scales or the kind of scale needed: some scales takes into account both peer pressure to do and peer pressure not to do, while others consider only peer pressure to do. The aim of the present study was to adapt French and German versions of the Peer Pressure Inventory, which is one of the most widely used scales in this field. We considered its factor structure and concurrent validity. METHODS: Five thousand eight hundred and sixty-seven young Swiss men filled in a questionnaire on peer pressure, substance use, and other variables (conformity, involvement) in a cohort study. RESULTS: We identified a four-factor structure, with the three factors of the initial Peer Pressure Inventory (involvement, conformity, misconduct) and adding a new one (relationship with girls). A non-valued scale (from no peer pressure to peer pressure to do only) showed stronger psychometric qualities than a valued scale (from peer pressure not to do to peer pressure to do). Concurrent validity was also good. Each behavior or attitude was significantly associated with peer pressure. CONCLUSION: Peer pressure seems to be a multidimensional concept. In this study, peer pressure to do showed the strongest influence on participants. Indeed, peer pressure not to do did not add anything useful. Only peer pressure to do affected young Swiss men's behaviors and attitudes and was reliable.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Nasal continuous positive airways pressure (n-CPAP) is an effective treatment in premature infants with respiratory distress. The cardio-pulmonary interactions secondary to n-CPAP are well studied in adults, but less well described in premature infants. We postulated that there could be important interactions with regard to the patent ductus arteriosus (PDA). Methods: Prospective study, approved by the local ethic committee. Premature infants less than 32 weeks gestation, _7 days-old, needing n-CPAP for respiratory distress, but without the need of additional oxygen were included in the study. Every patient had a first echocardiography with n-CPAP and then n-CPAP was retrieved. 3 hours later the echocardiography was repeated by the same investigator and then the patient replaced on n-CPAP. Results: 14 premature newborn were included, mean gestational age of 28 _ 2 weeks, mean weight 1.1 _ 0.3 Kg and height 39 _ 3 cm. Echocardiographic measurements are depicted in Table 1. Significant finding were observed between measurement on n- CPAP or without n-CPAP: on end diastolic left ventricular diameter (12.8 _ 1.6 mm vs. 13.5 _ 2 mm), on end systolic left ventricular diameter (8.4 _ 1.3 mm vs. 9.1 _ 1.5 mm), left atrium diameter (8.9 _ 2.2 mm vs. 10.4 _ 2.5 mm), maximal velocity on tricuspid valve (46 _ 10 cm/s vs. 51 _ 9 cm/s), calculated Qp (3.7 _ 0.8 L/min/m2 vs. 4.3 _ 0.8 L/min/m2). Only three patients have demonstrated a PDA during the study. Conclusion: Positive end expiratory pressure (Peep) has hemodynamic effects which are: reduction of systemic and pulmonary venous return as shown by the changes on tricuspid valve inflow,on the calculated Qp and finally on the diameter of the left atrium and left ventricle.We found in premature infants the same hemodynamic effects than those described in adults but with lower Peep values. This could be due to the particular elasticity and weakness of the thoracic wall of premature infants. Interestingly the flow through a PDA seems also to be diminished with Peep, but the number of patients is insufficient to conclude. Further investigation will be needed to better understand these interactions. Table 1. Echocardiographic measurement (mean (SD)). With n-CPAP Without n-CPAP p value RV ED diameter (mm) 6.3 (1.7) 6.04 (1.1) NS LV ED diameter (mm) 12.8 (1.6) 13.5 (2.0) _0.05 LV ES diameter (mm) 8.4 (1.3) 9.1 (1.5) _0.05 SF (%) 34 (5) 33 (6) NS Ao valve diameter (mm) 7.4 (1.3) 7.4 (1.2) NS LA diameter (mm) 8.9 (2.2) 10.4 (2.5) _0.05 Vmax Ao (cm/s) 70 (16) 71 (18) NS Vmax PV (cm/s) 69 (15) 72 (16) NS Vmax TV (cm/s) 46 (10) 51 (9) _0.05 Vmax MV (cm/s) 53 (17) 54 (18) NS Qp (L/min/m2) 3.7 (0.8) 4.3 (0.8) _0.05 Qs (L/min/m2) 4.0 (0.8) 4.0 (0.7) NS Qp/Qs 0.92 (0.14) 1.09 (0.23) _0.05 RV: right ventricle, LV: left ventricle, ED: end diastolic, ES: end systolic, SF: shortening fraction,Ao: aortic valve, LA: left atrium,Vmax: maximum Doppler Velocity, Qp: pulmonary output, Qs: systemic output, NS: non significant.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Exposure to fine particles and noise has been linked to cardiovascular diseases and elevated cardiovascular mortality affecting the worldwide population. Residence and/or work in proximity to emission sources as for example road traffic leads to an elevated exposure and a higher risk for adverse health effects. Highway maintenance workers spend most of their work time in traffic and are exposed regularly to particles and noise. The aims of this thesis were to provide a better understanding of the workers' mixed exposure to particles and noise and to assess cardiopulmonary short term health effects in relation to this exposure. Exposure and health data were collected in collaboration with 8 maintenance centers of the Swiss Road Maintenance Services located in the cantons Bern, Fribourg and Vaud in western Switzerland. Repeated measurements with 18 subjects were conducted during 50 non-consecutive work shifts between Mai 2010 and February 2012, equally distributed over all seasons. In the first part of this thesis we tested and validated measurements of ultrafine particles with a miniature diffusion size classifier (miniDiSC) - a novel particle counting device that was used for the exposure assessment during highway maintenance work. We found that particle numbers and average particle size measured by the miniDiSC were highly correlated with data from the P-TRAK, a condensation particle counter (CPC), as well as from a scanning mobility particle sizer (SMPS). However, the miniDiSC measured significantly more particles than the P-TRAK and significantly less than the SMPS in its full size range. Our data suggests that the instrument specific cutoffs were the main reason for the different particle counts. The first main objective of this thesis was to investigate the exposure of highway maintenance workers to air pollutants and noise, in relation to the different maintenance activities. We have seen that the workers are regularly exposed to high particle and noise levels. This was a consequence of close proximity to highway traffic and the use of motorized working equipment such as brush cutters, chain saws, generators and pneumatic hammers during which the highest exposure levels occurred. Although exposure to air pollutants were not critical if compared to occupational exposure limits, the elevated exposure to particles and noise may lead to a higher risk for cardiovascular diseases in this worker population. The second main objective was to investigate cardiopulmonary short-term health effects in relation to the particle and noise exposure during highway maintenance work. We observed a PM2.5 related increase of the acute-phase inflammation markers C-reactive protein and serum amyloid A and a decrease of TNFa. Heart rate variability increased as a consequence of particle as well as noise exposure. Increased high frequency power indicated a stronger parasympathetic influence on the heart. Elevated noise levels during recreational time, after work, were related to increased blood pressure. Our data confirmed that highway maintenance workers are exposed to elevated levels of particles and noise as compared to the average population. This exposure poses a cardiovascular health risk and it is therefore important to make efforts to better protect the workers health. The use of cleaner machines during maintenance work would be a major step to improve the workers' situation. Furthermore, regulatory policies with the aim of reducing combustion and non-combustion emissions from road traffic are important for the protection of workers in traffic environments and the entire population.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We estimated the heritability of ambulatory systolic blood pressure (SBP), diastolic blood pressure (DBP), and pulse pressure (PP) in east African families with at least 2 hypertensive siblings and living in the Seychelles islands (Indian Ocean). The sample consisted of 314 individuals (147 men and 167 women), both normotensive and hypertensive, from 76 pedigrees (mean+/-SD of 4.1+/-2.8 persons per pedigree). After a 2-week off-treatment period, daytime and nighttime ambulatory blood pressure (BP) was monitored. Office BP was measured with a standard mercury sphygmomanometer. We estimated by maximum likelihood the age- and sex-adjusted heritabilities from the additive polygenic component of the variance of the traits allowing for the presence of other familial correlations. We also adjusted for ascertainment (ie, for the fact that 2 siblings had to be hypertensive) and examined the effect of adjusting for body mass index, 24-hour urinary excretion of sodium and potassium, plasma renin activity, and plasma aldosterone concentration. Heritability estimates (+/-SE) for ambulatory SBP, DBP, and PP were, respectively, 0.37+/-0.12/0.24+/-0.12/0.54+/-0.12 for daytime and 0.34+/-0.13/ 0.37+/-0.15/0.47+/-0.12 for nighttime measurements (P<0.05 for all estimates). Heritability estimates for office SBP, DBP, and PP were, respectively, 0.20+/-0.11, 0.05+/-0.09, and 0.37+/-0.12. Heritability estimates for SBP varied markedly according to whether participants were treated for hypertension at baseline. The present data show that ambulatory BP and PP have a high heritability in families of African descent. They also demonstrate that antihypertensive treatment and the number of BP measurements have a major influence on the heritability estimates.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Wear of polyethylene is associated with aseptic loosening of orthopaedic implants and has been observed in hip and knee prostheses and anatomical implants for the shoulder. The reversed shoulder prostheses have not been assessed as yet. We investigated the volumetric polyethylene wear of the reversed and anatomical Aequalis shoulder prostheses using a mathematical musculoskeletal model. Movement and joint stability were achieved by EMG-controlled activation of the muscles. A non-constant wear factor was considered. Simulated activities of daily living were estimated from in vivo recorded data. After one year of use, the volumetric wear was 8.4 mm(3) for the anatomical prosthesis, but 44.6 mm(3) for the reversed version. For the anatomical prosthesis the predictions for contact pressure and wear were consistent with biomechanical and clinical data. The abrasive wear of the polyethylene in reversed prostheses should not be underestimated, and further analysis, both experimental and clinical, is required.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Although platelet cytosolic calcium has been shown to decrease during pharmacological treatment of hypertension, there is no evidence that cytosolic calcium also falls during a nonpharmacological reduction in blood pressure. To provide such evidence, we examined prospectively the relation between platelet cytosolic calcium and ambulatory blood pressure during weight reduction in moderately overweight (body mass index [BMI] greater than 25), mildly hypertensive individuals. The experimental group (responders: BMI reduction greater than 5%) consisted of 19 patients who lost 8.5 +/- 2.9 kg (mean +/- SD, p less than 0.05) during a 10-week hypocaloric diet, whereas the control group (nonresponders: BMI reduction less than 5%) consisted of 12 patients who showed no relevant change in body weight (-2.0 +/- 1.3 kg) during the same period of time. The moderate weight loss of the responders decreased blood pressure by 14/5 mm Hg (p less than 0.05), as measured by ambulatory monitoring, which renders a placebo effect unlikely. This nonpharmacological reduction in blood pressure was accompanied by a proportional 11% decrease (p less than 0.05) in platelet cytosolic calcium and also by significant (p less than 0.05) decreases in plasma catecholamines and serum cholesterol. These findings establish the concept of a nonpharmacological reduction in free cytosolic platelet calcium in humans and add further evidence suggesting a link between intracellular calcium homeostasis and blood pressure regulation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Blood pressure is lowered for a few hours after aerobic exercise, but also after resistance exercise, although for a shorter period of time. An exercise program can significantly lower resting and ambulatory BP measurements. Multiple mechanisms interact for the BP lowering effect, such as decreased total peripheral resistance, enhanced endothelial function, diminished sympathetic or rennin plasmatic activity, structural vascular modifications and baroreceptor reflex modulation. New exercises like eccentric or isometric (handgrip) contractions are promising. Resistance activities have long been considered dangerous for blood vessels because of increased arterial stiffness, but if the intensity remains moderate and aerobic exercises are integrated, then the effects are altogether beneficial.