989 resultados para plume


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper presents the results of electrical resistivity methods in the area delineation that was potentially contaminated by liquefaction products, which are also called putrefactive liquids in Vila Rezende municipal cemetery, Piracicaba, So Paulo, Brazil. The results indicate a depth of water table between 3.1 and 5.1 m, with two groundwater direction flows, one to the SW and another to the SE. Due to the contamination plumes, which have the same groundwater direction flow, as well the conductive anomalies observed in the geoelectric sections, the contamination suspicions in the area were confirmed. The probable plume to the SE extends beyond the limits of the cemetery. The location of the conductive anomalies and the probable contamination plumes showed that the contamination is linked with the depth of the water table and the burial time. Mapping using the geostatistical method of ordinary kriging applied to the work drew structural characteristics of the regional phenomenon and spatial behavior of the electrical resistivity data, resulting in continued surfaces. Thus, this method has proved to be an important tool for mapping contamination plumes in cemeteries.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This article compares the efficiency of induced polarization (IP) and resistivity in characterizing a contamination plume due to landfill leakage in a typical tropical environment. The resistivity survey revealed denser electrical current flow that induced lower resistivity values due to the high ionic content. The increased ionic concentration diminished the distance of the ionic charges close to the membrane, causing a decrease in the IP phenomena. In addition, the self-potential (SP) method was used to characterize the preferential flow direction of the area. The SP method proved to be effective at determining the flow direction; it is also fast and economical. In this study, the resistivity results were better correlated with the presence of contamination (lower resistivity) than the IP (lower chargeability) data.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Particle size distributions for soluble and insoluble species in Mt. Etna's summit plumes were measured across an extended size range (10 nm < d < 100 mu m) using a combination of techniques. Automated scanning electron microscopy (QEMSCAN) was used to chemically analyze many thousands of insoluble particles (collected on pumped filters) allowing the relationships between particle size, shape, and composition to be investigated. The size distribution of fine silicate particles (d < 10 mu m) was found to be lognormal, consistent with formation by bursting of gas bubbles at the surface of the magma. The compositions of fine silicate particles were found to vary between magmatic and nearly pure silica; this is consistent with depletion of metal ions by reactions in the acidic environment of the gas plume and vent. Measurements of the size, shape and composition of fine silicate particles may potentially offer insights into preemission, synemission, and postemission processes. The mass flux of fine silicate particles from Mt. Etna released during noneruptive volcanic degassing in 2004 and 2005 was estimated to be similar to 7000 kg d(-1). Analysis of particles in the range 0.1 < d/mu m < 100 by ion chromatography shows that there are persistent differences in the size distributions of sulfate aerosols between the two main summit plumes. Analysis of particles in the range 0.01 mu m < d < 0.1 mu m by scanning transmission electron microscopy (STEM) shows that there are significant levels of nanoparticles in the Mt. Etna plumes although their compositions remain uncertain.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O descarte indevido de resíduos industriais no solo tem causado danos ao meio ambiente e à saúde humana. A identificação e o diagnóstico de áreas contaminadas é um procedimento necessário afim de que seja possível tomar medidas de contenção da fonte poluidora e posterior remediação. As técnicas geofísicas podem auxiliar na caracterização do meio geológico, definição das dimensões da pluma de contaminação, seleção de pontos para locação de poços de monitoramento e de bombeamento. Este trabalho apresenta os resultados da aplicação do método Eletromagnético Indutivo em uma área industrial contaminada por benzeno, tolueno, xileno (BTX) e dicloroetano. Os resultados indicam dois padrões de migração dos contaminantes em subsuperfície. Uma tendência de migração no plano horizontal até o nível de 15 m de profundidade e uma tendência de migração no plano vertical entre 15 e 60 m de profundidade. As tendências de migração divergentes estão condicionadas a densidade dos compostos que constituem a pluma de contaminação, ou seja, um intervalo LNAPL sobrenadante (BTX), sobreposto a um intervalo DNAPL (1,2 dicloroetano).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O uso combinado de poços de amostragem e técnicas geofísicas constitui a maneira mais adequada para identificação e o monitoramento de áreas contaminadas. Este procedimento permite a locação de poços de amostragem e de monitoramento em pontos estratégicos, otimizando resultados e minimizando gastos. O método geofísico Eletromagnético Indutivo (EM) apresenta amplas possibilidades de aplicação em estudos ambientais devido à facilidade na aquisição de dados, versatilidade do equipamento em campo e a possibilidade de varredura de grandes áreas num curto espaço de tempo. Este trabalho realiza uma análise comparativa de dados em obtidos no ano de 1992 e em 2003. O local estudado é uma área industrial que apresenta contaminação do solo e água subterrânea por Benzeno, Tolueno, Xileno, 1,2 dicloroetano, Sódio e Cloreto, produto da infiltração de efluentes químicos diretamente do solo. Os resultados indicam uma acentuada atenuação da pluma contaminante, com provável redução no grau de contaminação. Os compostos de fase leve (LNAPLs) apresentaram maior tendência de migração horizontal, concomitante ao movimento da água subterrânea. Os compostos de fase densa (DNAPLs) apresentaram uma tendência mais acentuada de migração no sentido vertical, possivelmente devido à ausência de superfícies impermeáveis. Os compostos inorgânicos acompanharam o fluxo dos compostos de fase líquida não aquosa (NAPLs), o que por sua vez permitiu a caracterização da pluma de contaminação como um corpo condutivo em relação às áreas adjacentes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Different geoenvironmental site investigation techniques to assess contamination from a municipal solid waste disposal site in Brazil are presented here. Superficial geophysical investigation (geoelectrical survey), resistivity piezocone penetration tests (RCPTU), soil samples collected with direct-push samplers and water samples collected from monitoring wells were applied in this study. The application of the geoelectrical method was indispensable to identify the presence and flow direction of contamination plumes (leachate) as well as to indicate the most suitable locations for RCPTU tests and soil and water sampling. Chemical analyses of groundwater samples contributed to a better understanding of the flow of the contaminated plume. The piezocone presented some limitations for tropical soils, since the groundwater level is sometimes deeper than the layer which is impenetrable to the cone, and the soil genesis and unsaturated conditions affect soil behavior. The combined interpretation of geoelectrical measurements and soil and water samplings underpinned the interpretation of RCPTU tests. The interpretation of all the test results indicates that the contamination plume has already overreached the landfill's west-northwest borders. Geoenvironmental laboratory test results suggest that contamination from the solid waste disposal site has been developing gradually, indicating the need for continuous monitoring of the groundwater.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We describe the first satellite observation of intercontinental transport of nitrogen oxides emitted by power plants, verified by simulations with a particle tracer model. The analysis of such episodes shows that anthropogenic NOx plumes may influence the atmospheric chemistry thousands of kilometers away from its origin, as well as the ocean they traverse due to nitrogen fertilization. This kind of monitoring became possible by applying an improved algorithm to extract the tropospheric fraction of NO2 from the spectral data coming from the GOME instrument.As an example we show the observation of NO2 in the time period 4-14 May, 1998, from the South African Plateau to Australia which was possible due to favourable weather conditions during that time period which availed the satellite measurement. This episode was also simulated with the Lagrangian particle dispersion model FLEXPART which uses NOx emissions taken from an inventory for industrial emissions in South Africa and is driven with analyses from the European Centre for Medium-RangeWeather Forecasts. Additionally lightning emissions were taken into account by utilizing Lightning Imaging Sensor data. Lightning was found to contribute probably not more than 25% of the resulting concentrations. Both, the measured and simulated emission plume show matching patterns while traversing the Indian Ocean to Australia and show great resemblance to the aerosol and CO2 transport observed by Piketh et al. (2000).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper presents two case histories from Brazil where geophysical and resistivity piezocone tests were carried out to detect contamination. At the first one, the site investigation program was carried out to detect salt-water intrusions in a superficial sedimentary aquifer, at the Paranaguá harbor, in Paraná State. The second case history is a sanitary landfill from Bauru City, São Paulo State. In both sites, superficial geophysical tests were interpreted to detect and delineate the shape of contamination plume, helping to locate the resistivity piezocone tests. It was found that the interpretation of resistivity piezocone tests is straightforward to assess salt-water intrusion in sedimentary sands. For tropical soils, this technique presented some limitations since the groundwater table sometimes is deeper than the layer penetratable to the cone. Moreover, the genesis of those soils affects soil behavior and soil and water sampling is required to support interpretation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Due to lack of environmental protection with which the process of burying the corpses was conducted over the decades, many cemeteries have become areas contaminated by organic and inorganic substances and pathogenic microrganisms. This paper presents the results of electrical imaging in delineation of areas potentially contaminated by necrochorume in the municipal cemetery of Vila Rezende, Piracicaba - SP. The results indicate a depth of water table among 3,1 and 5,1 m, with two flow directions, being one to SW and another to SE. So the probable contamination plume, that has the same directions of underground flow, as for the conductive anomalies verified at the geoelectrics sections confirm the suspicions of contamination in the area. The probable plume the SE is prolonged to out of the cemetery. The location of the conductive anomalies and likely contamination plumes demonstrated that the contamination is linked with the depth of water table level and the burial time.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Several factors have contributed to the increase the world production of urban solid waste, resulting in difficulties to the correct management and the final environmentally appropriate disposal, in addition to causing serious socio-economic, environmental, and public health troubles. The soil and groundwater contamination by leachate in waste disposal sites is almost always present, leveraging the emergence and/or adaptation of methodologies for environmental assessment of these areas. The geophysical methods, especially the electrical resistivity method, are fast, reliable and low-cost alternative for this purpose. This paper reports the methodology adopted for the temporal monitoring of the plume of contamination of controlled landfill in the municipality of Rio Claro (SP). Electrical resistivity data were obtained in 1999 and 2008, by the resistivity method, using the techniques of vertical electrical sounding and electrical profile. In both years, similar tests were carried out in the same locations within the disposal area. The results indicated that the plume of contamination has resistivity values less than or equal to 50 ohm.m and moves guided by 2 flows: the main, to the southeast, and the secondary, to the west. Relatively to the first series of tests in 1999, the plume of contamination was higher and deeper in 2008, contrary to what was expected for a landfill deactivated for at least 10 years.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

There has been little research on geochemistry and isotopic compositions in tholeiites of the Northern region from the Paraná Continental Flood Basalts (PCFB), one of the largest continental provinces of the world. In order to examine the mantle sources involved in the high-Ti (Pitanga and Paranapanema) basalt genesis, we studied Sr, Nd, and Pb isotopic systematics, and major, minor and incompatible trace element abundances. The REE patterns of the investigated samples (Pitanga and Paranapanema magma type) are similar (parallel to) to those of Island Arc Basalts' REE patterns. The high-Ti basalts investigated in this study have initial (133Ma) 87Sr/86Sr ratios of 0.70538-0.70642, 143Nd/144Nd of 0.51233-0.51218, 206Pb/204Pb of 17.74-18.25, 207Pb/204Pb of 15.51-15.57, and 208Pb/204Pb of 38.18-38.45. These isotopic compositions do not display any correlation with Nb/Th, Nb/La or P2O5/K2O ratios, which also reflect that these rocks were not significantly affected by low-pressure crustal contamination. The incompatible trace element ratios and Sr-Nd-Pb isotopic compositions of the PCFB tholeiites are different to those found in Tristan da Cunha ocean island rocks, showing that this plume did not play a substantial role in the PCFB genesis. This interpretation is corroborated by previously published osmium isotopic data (initial γOs values range from+1.0 to+2.0 for high-Ti basalts), which also preclude basalt generation by melting of ancient subcontinental lithospheric mantle. The geochemical composition of the northern PCFB may be explained through the involvement of fluids and/or small volume melts related to metasomatic processes. In this context, we propose that the source of these magmas is a mixture of sublithospheric peridotite veined and/or interlayered with mafic components (e.g., pyroxenites or eclogites). The sublithospheric mantle (dominating the osmium isotopic compositions) was very probably enriched by fluids and/or magmas related to the Neoproterozoic subduction processes. This sublithospheric mantle region may have been frozen and coupled to the base of the Parana basin lithospheric plate above which the Paleozoic subsidence and subsequent Early Cretaceous magmatism occurred. © 2013 Elsevier Ltd.