928 resultados para plate-out effect


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Contamination with cadmium compounds poses high potential risk for the health of populations and for this reason the treatment of their toxic effects should urgently be established. The present study was carried out to determine whether α-tocopherol intake can protect tissues against damage induced by cadmium, and to clarify the contribution of superoxide radicals (O 2 -) in this process. Cadmium chloride was tested for tissue damage by a single intraperitoneal injection of Cd 2+ ions (2 mg Kg -1). To determine the potential therapeutic effect of vitamin E, a group of Cd 2+-treated rats received a drinking solution of α-tocopherol (40 mg l -1) for 15 days. Cadmium induced increased serum creatinine and total lactate dehydrogenase, reflecting renal and cardiac damage. The increased lipoperoxide and decreased Cu-Zn superoxide dismutase levels indicated the generation of superoxide radicals in cadmium-treated rats. Tocopherol induced increased serum high-density lipoprotein and depressed the toxic effects of Ca 2+ alone, since creatinine and lactate dehydrogenase determinations were recovered to the control values. Tocopherol decreased lipoperoxide and led the superoxide dismutase activities to approach those of the control values. We concluded that superoxide radicals are produced as mediators of cadmium toxicity. Tocopherol possesses a significant anti-radical activity and inhibits the cadmium effect on superoxide dismutase activity. Tocopherol also protected tissues from the toxic effects of cadmium by a direct antioxidant action which decreased lipoperoxide formation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The effect of the continuous emission hypothesis on the two-pion Bose-Einstein correlation function is discussed and compared with the corresponding results based on the usual freeze-out. Sizable differences in the correlation function appear in these different descriptions of the decoupling process. This means that, when extracting properties of the hot matter formed in high-energy heavy-ion collisions from the data, completely different conclusions may be reached according to the description of the particle emission process adopted.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Several studies have shown a reduction in enamel bond strengths when the bonding procedure is carried out immediately after vital bleaching with peroxides. This reduction in bond strengths has become a concern in cosmetic dentistry with the introduction of new in-office and waiting-room bleaching techniques. The aim of this in vitro study was to evaluate the effect of three bleaching regimens: 35% hydrogen peroxide (HP), 35% carbamide peroxide (CP), and 10% CP, on dentin bond strengths. Materials and Methods: One hundred and twenty fresh bovine incisors were used in this study. The labial surface of each tooth was ground flat to expose dentin and was subsequently polished with 600-grit wet silicon carbide paper. The remaining dentin thickness was monitored and kept at an average of 2 mm. The teeth were randomly assigned to four bleaching regimens (n = 30): (A) control, no bleaching treatment; (B) 35% HP for 30 minutes; (C) 35% CP for 30 minutes; and (D) 10% CP for 6 hours. For each group, half of the specimens (n = 15) were bonded with Single Bond/Z100 immediately after the bleaching treatment, whereas the other half was bonded after the specimens were stored for 1 week in artificial saliva at 37°C. The specimens were fractured in shear using an Instron machine. Results: For the groups bonded immediately after bleaching, one-way analysis of variance (ANOVA) followed by the Duncan's post hoc test revealed a statistically significant reduction in bond strengths in a range from 71% to 76%. For the groups bonded at 1 week, one-way ANOVA showed that group B (35% HP for 30 min) resulted in the highest bond strengths, whereas 10% CP resulted in the lowest bond strengths. Student's t-test showed that delayed bonding resulted in a significant increase in bond strengths for groups B (35% HP) and C (35% CP); whereas the group bleached with 10% CP (group D) remained in the same range obtained for immediate bonding. Storage in artificial saliva also affected the control group, reducing its bond strengths to 53% of the original. ©2000 BC Decker Inc.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The parasitic mite Acarophenax lacunatus kills the eggs upon which it feeds and seems to have potential as a biological control agent of stored grain pests. The lack of biological studies on this mite species led to the present study carried out in laboratory conditions at eight different temperatures (ranging from 20 to 41°C) and 60% relative humidity using Rhyzopertha dominica as host. The higher the temperature, the faster: (1) the attachment of female mites to the host egg (varying from 1 to 5 h); (2) the increase in body size of physogastric females (about twice faster at 40°C than at 20°C); and (3) the generation time (ranging from 40 to 220 h). In addition, the higher the temperature, the shorter the maximum female longevity (ranging from about 75 to 300 h). The two estimated temperature thresholds for development of A. lacunatus on R. dominica were 18 and 40°C. The average number of female and male offspring per gravid mite were 12.8 and 1.0, respectively, with sex ratios (females/total) ranging from 0.91 to 0.94 (maximum at 30°C). The net reproductive rate and intrinsic rate of increase also presented maximum values at 30°C (12.1 and 0.04, respectively).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The increased demand for juvenile tambaqui Colossoma macropomum for grow-out ponds and stocking programs in the Amazon state of Brazil has increased the transportation of this species. This study was designed to determine the optimum density of juvenile tambaqui during transportation in closed containers. Fish (51.9 ± 3.3 g and 14.9 ± 0.4 cm) were packed in sealed plastic bags and transported for 10 h at four densities: 78, 156, 234, and 312 kg/m3. After transportation, fish from each density were kept in separate 500-L tanks for 96 h. Mortality, 96-h cumulative mortality, water quality, and blood parameters (hematocrit, plasma cortisol, and glucose) were monitored. Fish mortality after transportation was significantly lower at densities of 78 and 156 kg/m3 than at 234 and 312 kg/m3. Cumulative mortality was significantly lower at a density of 78 kg/m3. Dissolved oxygen after 10 h of transportation remained high at a density of 78 kg/m3, but reached critically low values at all other densities. Ammonia concentration was highest at the lowest density and was lower at higher densities. Carbon dioxide concentration was lowest at the density of 78 kg/m3 but higher in the other treatments. Plasma glucose and cortisol increased significantly immediately after transportation at densities of 156, 234, and 312 kg/m3, returning to control values by 24 h. The best density for juvenile tambaqui during a 10-h transportation haul in a closed container was 78 kg/m3. At this density there was no fish mortality, water quality was kept within acceptable values, and fish were not stressed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Chrysanthemums are commercially propagated through cuttings. Pre-rooting storage of cuttings in the dark is a common practice among growers and companies that work and trade with chrysanthemum cuttings. Therefore, the maximum storage period for cuttings and differences in tolerance among cultivars has been investigated. Adventitious roots of cuttings can originate in almost any tissue, including the epidermis, stem cortex and pericycle, ray parenchyma, immature xylem and phloem cells, and pith. The aims of this work were to determine the effect of time of cold storage of cuttings (0, 1, 2, 3, 4, 5 and 6 weeks) on the rooting of four cut chrysanthemum cultivars (Super White, Sheena, Dark Orange Reagan and Town Talk) for two seasons of the year (summer and winter), and also to determine the origin of root formation in chrysanthemum cuttings. The study was carried out as a randomized complete block design with 5 replications for each storage treatment. Each plot was comprised of three cuttings that were examined 14 days after the cutting procedure. During the winter, the roots were studied by scanning electron microscopy (SEM) at the Electron Microscope Laboratory. The following conclusions were made: in winter, cold storage affected the rooting of cuttings, mainly after two weeks of storage for all cultivars. The rooting percentage was lower in the winter and the cuttings could be preserved for a shorter period. The source and growth of roots in chrysanthemum cuttings was found to be endogenous. After three days, callus formed in the pericycle and the first emergence of adventitious roots occurred by the fourth day of rooting. During the summer, cold storage could be up to 4 weeks without any problems.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Alterations in the synthesis or enhanced inactivation of nitric oxide (NO) and increase in fibrin deposition in the vascular bed lead to an imbalance that can induced intravascular coagulation. NO is produced through L-arginine pathway by constitutive and inducible nitric oxide synthase (NOS). The inducible isoform can be activated by cytokines such as tumor necrosis factor alfa. We evaluated NO-induced tissue-plasminogen activator (t-PA) release from isolated aortic segments of Wistar rats measuring the fibrinolytic activity in the fibrin plate. Inhibition of NO biossynthesis with Nω-nitro-L-arginine (NωNLA) significantly attenuated the fibrinolytic activity (FA) evoked by aortic segments of this group (GII) compared to the saline group (GI). The administration of L-arginine produced restoration of FA in this group (GIII) treated with NωNLA suggesting that t-PA arising from segments of rat aorta is influenced by NO.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Lead zirconate titanate (PZT) solutions were prepared using a polymeric precursor method, Zr n-propoxide and Ti i-propoxide were used as starting materials with ethylene glycol and water as solvents. The PZT solution was spin-coated on Pt/Ti/SiO2/Si substrates, baked on a hot plate, and finally heat-treated in a tube furnace between 400 and 800°C. The surface morphology and grain size of the films were characterized by atomic force microscopy (AFM), using a tapping mode with amplitude modulation. The films, thermal annealed at temperatures higher than 500°C, exhibited a dense microstructure, without noticeable cracks or voids. Electrical properties were investigated as a function of composition and annealing temperature.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: The objective of the present investigation was to assess the histological effects of different wavelengths and intensities on the healing process of cutaneous wounds. Background Data: Tissue repair is a dynamic interactive process which involves mediators, cells and extra-cellular matrix. Several reports on the use of laser therapy have shown that the healing process is positively affected when the correct parameters are used. Methods: Eighteen standardized wounds were surgically created on the dorsum of male and female Wistar rats, which were subsequently divided into two experimental groups according to wavelength used λ.670 or λ685 nm) for lasertherapy (LLLT). Each group was divided into three subgroups of three animals according to the intensity of the applied irradiation (2,15, or 25 mW). Twelve animals were used as entreated controls and were not irradiated. The irradiation was carried out during seven consecutive days. The animals were sacrificed eight days after surgery. The specimens were removed, kept in 4% formaldehyde for 24 h, routinely prepared to wax, stained with H&E, and analyzed under light microscopy. Results: For both groups, light microscopy showed a substitution repair process; however, when LLLT was used, a positive biomodulatory effect was detectable, chiefly associated with shorter wavelength and low intensity. Conclusions: The results of the present study indicate that LLLT improved cutaneous wound repair and that the effect is a result of an inversely proportional relationship between wavelength and intensity, with treatment more effective when combining higher intensity with short wavelength or lower intensity with higher wavelength.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: This study tested the hypothesis that the tribochemical silica coating on ceramic surfaces increases the bond strength of resin cement to a glass-infiltrated zirconium-based ceramic. Materials and Methods: Fifteen blocks of In-Ceram Zirconia from CEREC InLab (5 per group) and 15 composite blocks (Z-250) 5 mm x 5 mm x 4 mm were made. The ceramic surfaces were polished, and the blocks were divided into three groups: (1) airborne abrasion with 110-μm aluminum oxide particles; (2) Rocatec system, tribochemical silica coating; and (3) CoJet system, tribochemical silica coating. The ceramic blocks were cemented to the composite blocks using Panavia F according to the manufacturer's specifications. All samples were stored in 37°C distilled water for 7 days and later sectioned in two axes using a diamond disk under cooling to obtain specimens with a cross-sectional area of approximately 1 mm2 (n = 45). Each specimen was then attached with cyanoacrylate glue to an adapted device for the microtensile test, which was carried out on a universal testing machine. Results: The results were subjected to ANOVA and Tukey's test. Group 2 (23.0 ± 6.7 MPa) and group 3 (26.8 ± 7.4 MPa) showed greater bond strength than group 1 (15.1 ± 5.3 MPa). There was no significant difference between groups 2 and 3. All failures were in the adhesive zone. Conclusion: The hypothesis was confirmed - the tribochemical systems increased the bond strength between Panavia F and In-Ceram Zirconia.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study had the objective to evaluate the homeopathic action of Arnica montana 6 cH and placebo on edema, mouth opening (trismus) and pain in patients submitted to extraction of bilaterally impacted lower third molars. The experiment was carried out as a crossover and double-blind study. The data showed that edema was significantly reduced by the treatment with Arnica montana 6 cH (p<0.05) and did not demonstrate significant effect on trismus and pain as compared to control group.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: To evaluate the influence of water bath and microwave postpolymerization treatments on the cytotoxicity of 6 hard reline acrylic resins. Materials and Methods: The materials tested were Tokuso Rebase Fast (TR), Ufi Gel Hard (UGH), Duraliner II (D), Kooliner (K), New Truliner (NT), and Light Liner (LL). LL resin was additionally tested with an air-barrier coating (LLABC). Nine disks of each material (10 × 1 mm) were made and divided into 3 groups: group 1 (no postpolymerization treatment); group 2 (postpolymerization in microwave oven); group 3 (postpolymerization in water bath at 55°C for 10 minutes). L929 cells were cultured in 96-well plates and incubated for 24 hours in Eagle's medium. Eluates prepared from the disks or medium without disks (control) replaced the medium. Cytotoxicity was assessed by both dehydrogenase succinic activity (MTT) assay and incorporation of radioactive 3H-thymidine assay. Tests were carried out in quadruplicate and repeated twice. Differences between groups were determined by analysis of variance with Tukey multiple-comparison intervals (α = .05). Results: For MTT assay, the postpolymerization treatments had no effect on the cytotoxicity of all materials (P > .05). For 3H-thymidine assay, the postpolymerization treatments significantly decreased the cytotoxicity of UGH (P < .05). The cytotoxicity of K, NT, LL, and LLABC increased after microwave irradiation (P < .05). TR, NT, and LLABC showed an increase in cytotoxicity after water bath (P < .05). Conclusion: When assessed by MTT assay, the cytotoxicity of the materials was not affected by postpolymerization treatments. 3H-Thymidine assay showed that the cytotoxicity of the resins was not improved by the postpolymerization treatments, with the exception of UGH.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study aimed at evaluating the antisepsis of the root canal system (RCS) and periapical region (PR) provided by rotary instrumentation associated with chlorhexidine + calcium hydroxide as intracanal medicament. Chronic periapical lesions were induced in 26 pre-molar roots in two dogs. After microbiological sampling, automatic instrumentation using the Profile system and irrigation with 5.25% sodium hypochlorite solution, with a final rinse of 14.3% EDTA followed by profuse irrigation with physiological saline were carried out in 18 root canals. After drying the canals, a paste based on calcium hydroxide associated with a 2% chlorhexidine digluconate solution was placed inside them. After 21 days, the medication was removed, leaving the root canals empty and coronally sealed. After 96 hours, a final microbiological sample was obtained, followed by histomicrobiological processing by the Brown & Brenn method. Eight untreated root canals represented the control group (C-G). Based on the Mann-Whitney test at a confidence level of 5% (p < 0.05), the procedures of antisepsis used offered significant efficacy (p < 0.05) resulting in 100.0% of the canals free of microorganisms. In the C-G, an elevated incidence of various microbial morphotypes was confirmed in all sites of the RCS, with the presence of microbial colonies in the periapical region. In contrast, the experimental group showed a similar pattern of infection in the RCS, although less intense and a reduced level of periapical infection (p < 0.05). It was concluded that adequate instrumentation followed by the application of calcium hydroxide + chlorhexidine offered significant elimination of microorganisms.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this study was to evaluate the antimicrobial effect of biomechanical preparation using different irrigating solutions. Seventy-eight root canals from premolars of four dogs were used. After experimental induction of periapical lesions, the root canals were prepared using the following solutions for irrigation: Group 1) 2.5% sodium hypochlorite (NaOCl); Group 2) 2% chlorhexidine (CHX); Group 3) saline solution and Group 4) control group with no biomechanical preparation. The microbiological evaluation of the root canals was performed by counting the colony forming units (CFUs) using different culture mediums. Two absorbent paper cones were used in each root canal in order to collect the microbiological samples before, and thirty days after the biomechanical preparation. The culture plates were incubated in aerobic, anaerobic and microaerophilic environment. Statistical evaluation was carried out using analysis of variance, Tukey and Student tests. The results demonstrated that there was reduction in the number of microorganisms in the NaOCl and CHX groups (p<0.05). There was greater effectiveness in the chlorhexidine group. The group that used saline solution and the control group presented an increased number of microorganisms. It can be concluded that the use of antimicrobial irrigating solutions during biomechanical preparation promotes the reduction of endodontic microbiota. However, a considerable number of microorganisms were still observed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: The aim of this study was to evaluate the effect of two surface conditioning methods on the microtensile bond strength of a resin cement to three high-strength core ceramics: high alumina-based (In-Ceram Alumina, Procera AllCeram) and zirconia-reinforced alumina-based (In-Ceram Zirconia) ceramics. Materials and Methods: Ten blocks (5 ×6 × 8 mm) of In-Ceram Alumina (AL), In-Ceram Zirconia (ZR), and Procera (PR) ceramics were fabricated according to each manufacturer's instructions and duplicated in composite. The specimens were assigned to one of the two following treatment conditions: (1) airborne particle abrasion with 110-μm Al2O3 particles + silanization, (2) silica coating with 30 μm SiOx particles (CoJet, 3M ESPE) + silanization. Each ceramic block was duplicated in composite resin (W3D-Master, Wilcos, Petrópolis, RJ, Brazil) using a mold made out of silicon impression material. Composite resin layers were incrementally condensed into the mold to fill up the mold and each layer was light polymerized for 40 s. The composite blocks were bonded to the surface-conditioned ceramic blocks using a resin cement system (Panavia F, Kuraray, Okayama, Japan). One composite resin block was fabricated for each ceramic block. The ceramic-composite was stored at 37°C in distilled water for 7 days prior to bond tests. The blocks were cut under water cooling to produce bar specimens (n = 30) with a bonding area of approximately 0.6 mm2. The bond strength tests were performed in a universal testing machine (crosshead speed: 1 mm/min). Bond strength values were statistically analyzed using two-way ANOVA and Tukey's test (≤ 0.05). Results: Silica coating with silanization increased the bond strength significantly for all three high-strength ceramics (18.5 to 31.2 MPa) compared to that of airborne particle abrasion with 110-μm Al2O3 (12.7-17.3 MPa) (ANOVA, p < 0.05). PR exhibited the lowest bond strengths after both Al2O3 and silica coating (12.7 and 18.5 MPa, respectively). Conclusion: Conditioning the high-strength ceramic surfaces with silica coating and silanization provided higher bond strengths of the resin cement than with airborne particle abrasion with 110-μm Al2O3 and silanization.