919 resultados para permeation tube
Resumo:
The primary objective of this study was to determine if there is a change in permeation rates when limited use protective fabrics undergo repeated exposure and wash cycles. The null hypothesis of this study was that no substantial change in permeation takes place after the test material is subjected to repeated contact with a strong acid or base and has undergone repeated wash cycles. ^ The materials tested were DuPont Tychem® CPF 3 and CPF 4 fabrics. The challenge chemicals in this study were ninety-eight percent sulfuric acid and fifty percent sodium hydroxide. Permeation testing was conducted utilizing ASTM designation F739-99a Standard Test Method for Resistance of Protective Clothing Materials to Permeation by Liquids or Gases Under Conditions of Continuous Contact. ^ In this study, no change in permeation rates of either challenge chemical was detected for CPF 3 or CPF 4 limited use protective fabrics after repeated exposure and wash cycles. Certain unexposed areas of the fabric suffered structural degradation unrelated to exposure and which may be due to multiple washings.^
Resumo:
BACKGROUND. The development of interferon-gamma release assays (IGRA) has introduced powerful tools in diagnosing latent tuberculosis infection (LTBI) and may play a critical role in the future of tuberculosis diagnosis. However, there have been reports of high indeterminate results in young patient populations (0-18 years). This study investigated results of the QunatiFERON-TB Gold In-Tube (QFT-GIT) IGRA in a population of children (0-18 years) at Texas Children's Hospital in association with specimen collection procedures using surrogate variables. ^ METHODS. A retrospective case-control study design was used for this investigation. Cases were defined as having QFT-GIT indeterminate results. Controls were defined as having either positive or negative results (determinates). Patients' admission status, staff performing specimen collection, and specific nurse performing specimen collection were used as surrogates to measure specimen collection procedures. ^ To minimize potential confounding, abstraction of patients' electronic medical records was performed. Abstracted data included patients' medications and evaluation at the time of QFT-GIT specimen collection in addition to their medical history. QFT-GIT related data was also abstracted. Cases and controls were characterized using chi-squared tests or Fisher's exact tests across categorical variables. Continuous variables were analyzed using one-way ANOVA and t-tests for continuous variables. A multivariate model was constructed by backward stepwise removal of statistically significant variables from univariate analysis. ^ RESULTS. Patient data was abstracted from 182 individuals aged 0-18 years from July 2010 to August 2011 at Texas Children's Hospital. 56 cases (indeterminates) and 126 controls (determinates) were enrolled. Cancer was found to be an effect modifier with subsequent stratification resulting in a cancer patient population too small to analyze (n=13). Subsequent analyses excluded these patients. ^ The exclusion of cancer patients resulted in a population of 169 patients with 49 indeterminates (28.99%) and 120 determinates (71.01%), with mean ages of 9.73 (95% CI: 8.03, 11.43) years and 11.66 (95% CI: 10.75, 12.56) years (p = 0.033), respectively. Median age of patients who were indeterminates and determinates were 12.37 and 12.87 years, respectively. Lack of data for our specific nurse surrogate (QFTNurse) resulted in its exclusion from analysis. The final model included only our remaining surrogate variables (QFTStaff and QFTInpatientOutpatient). The staff collecting surrogate (QFTStaff) was found to be modestly associated with indeterminates when nurses collected the specimen (OR = 1.54, 95% CI: 0.51, 4.64, p = 0.439) in the final model. Inpatients were found to have a strong and statistically significant association with indeterminates (OR = 11.65, 95% CI: 3.89, 34.9, p < 0.001) in the final model. ^ CONCLUSION. Inpatient status was used as a surrogate for indication of nurse drawn blood specimens. Nurses have had little to no training regarding shaking of tubes versus phlebotomists regarding QFT-GIT testing procedures. This was also measured by two other surrogates; specifically a medical note stating whether a nurse or phlebotomist collected the specimen (QFTStaff) and the name and title of the specific nurse if collection was performed by a nurse (QFTNurse). Results indicated that inpatient status was a strong and statistically significant factor for indeterminates, however, nurse collected specimens and indeterminate results had no statistically significant association in non-cancer patients. The lack of data denoting the specific nurse performing specimen collection excluded the QFTNurse surrogate in our analysis. ^ Findings suggests training of staff personnel in specimen procedures may have little effect on the number of indeterminates while inpatient status and thus possibly illness severity may be the most important factor for indeterminate results in this population. The lack of congruence between our surrogate measures may imply that our inpatient surrogate gauged illness severity rather than collection procedures as intended. ^ Despite the lack of clear findings, our analysis indicated that more than half of indeterminates were found in specimens drawn by nurses and as such staff training may be explored. Future studies may explore methods in measuring modifiable variables during pre-analytical QFT-GIT procedures that can be discerned and controlled. Identification of such measures may provide insight into ways to lowering indeterminate QFT-GIT rates in children.^
Resumo:
An exposure system was constructed to evaluate the performance of a personal organic vapor dosimeter (3520 OVM) at ppb concentrations of nine selected target volatile organic compounds (VOCs). These concentration levels are generally encountered in community air environments, both indoor and outdoor. It was demonstrated that the chamber system could provide closely-controlled conditions of VOC concentrations, temperature and relative humidity (RH) required for the experiments. The target experimental conditions included combinations of three VOC concentrations (10, 20 and 200 $\rm\mu g/m\sp3),$ three temperatures (10, 25 and 40$\sp\circ$C) and three RHs (12, 50 and 90% RH), leading to a total of 27 exposure conditions. No backgrounds of target VOCs were found in the exposure chamber system. In the exposure chamber, the variation of the temperature was controlled within $\pm$1$\sp\circ$C, and the variation of RH was controlled within $\pm$1.5% at 12% RH, $\pm$2% at 50% RH and $\pm$3% at 90% RH. High-emission permeation tubes were utilized to generate the target VOCs. Various patterns of the permeation rates were observed over time. The lifetimes and permeation rates of the tubes differed by compound, length of the tube and manufacturer. By carefully selecting the source and length of the tubes, and closely monitoring tube weight loss over time, the permeation tubes can be used for delivering low and stable concentrations of VOCs during multiple days.^ The results of this study indicate that the performance of the 3520 OVM is compound-specific and depends on concentration, temperature and humidity. With the exception of 1,3-butadiene under most conditions, and styrene and methylene chloride at very high relative humidities, recoveries were generally within $\pm$25% of theory, indicating that the 3520 OVM can be effectively used over the range of concentrations and environmental conditions tested with a 24-hour sampling period. Increasing humidities resulted in increasing negative bias from full recovery. Reverse diffusion conducted at 200 $\rm\mu g/m\sp3$ and five temperature/humidity combinations indicated severe diffusion losses only for 1,3-butadiene, methylene chloride and styrene under increased humidity. Overall, the results of this study do not support the need to employ diffusion samplers with backup sections for the exposure conditions tested. ^