999 resultados para medidas flexibilidad interna


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Simple experiments are proposed for measuring molecular absorption of chromate and dichromate ions using an atomic absorption spectrometer. The experiments can help undergraduate students in instrumental analysis courses understand important aspects involving conceptual and instrumental similarities and differences between frequently used analytical techniques. Hollow cathode lamps were selected with wavelengths in the region of molecular absorption of chromate and dichromate. Calibration curves were obtained and the linear dynamic range was evaluated. Results were compared with those obtained in a molecular absorption spectrometer. The molar absorptivities obtained were also compared.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present work deals with the design and construction of an equipment for muti-cell accelerated stability test measurements (AST) of dimensionally stable anodes (DSA). The equipment was built using only components that were available in the laboratory. Measurements of three electrochemical cells can be performed using the developed software. The acquisition time interval and the cut-off potencial can be set by the user. Experimental data for RuO2 electrodes obtained with the built equipment are in agreement with the literature.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Com a resultat de les politiques i estratègies de col·laboració entre la universitat de Vic i de l’hospital i de la voluntat de realitzar activitats formatives conjuntes , s’estableix un línia de treball orientada a l’estudi i anàlisi de la situació logística interna actual del laboratori d’anàlisis clíniques de l’Hospital General de Vic. El treball es centra en el procés intern del laboratori i l’abast de l’estudi es troba limitat a les àrees especifiques d’hematologia i coagulació i bioquí… [+]mica. D’aquestes dues àrees el treball realitza un estudi exhaustiu del seu procés intern, identifica les seves activitats i la seva metodologia de treball amb l’objectiu d’elaborar el Value Stream Map de cadascuna de les àrees. Les àrees de Microbiologia, Banc de Sang i Urgències resten fora d’aquest estudi exhaustiu tot i que són presents en el treball per la inevitable interacció que tenen en la globalitat del procés. El treball es centra bàsicament en els processos automatitzats tot i que els processos que es duen a terme en el laboratori són tant automatitzats com manuals. També es limita al sistema productiu intern del laboratori tot i la interacció que té aquest sistema intern amb altres centres productius del sistema com ara són els centres d’atenció primària, els diversos hospitals i centres d’atenció sociosanitària. El laboratori es troba immers en el moment de l’elaboració d’aquest treball en un situació de canvi i millora del seus processos interns que consisteixen principalment en la substitució de part la maquinària actual que obliguen a la definició d’un nou layout i d’una nova distribució de la producció a cada màquina. A nivell extern també s’estan produint millores en el sistema informàtic de gestió que afecten a part del seu procés. L’objectiu del treball és donar visibilitat total al procés de logística interna actual del laboratori, identificant clarament com són i quina seqüència tenen els processos logístics interns i els mètodes de treball actuals, tant de recursos màquina com recursos persona, per poder identificar sota una perspectiva de generació de valor, aquells punts concrets de la logística interna que poden ser millorats en quant a eficiència i productivitat amb l’objectiu que un cop identificats es puguin emprendre accions i/o projectes de millora. El treball finalitza amb un anàlisis final del procés logística interna des d’una òptica Lean. Per fer-ho, identifica aquelles activitats que no aporten valor al procés o MUDA i les classifica en set categories i es realitzen diverses propostes de millora com són la implantació d’un flux continu , anivellat i basat en un concepte pull , identifica activitats que poden ser estandarditzades i/o simplificades i proposa modificacions en les infraestructures físiques per donar major visibilitat al procés. L’aspecte humà del procés es planteja des d’un punt de vist de metodologia, formació, comunicació i aplicació de les 5S.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple and low-cost flow cell with 30 cm optical path for spectrophotometric measurements is described. It presents desirable characteristics such as low attenuation of the radiation beam and internal volume (75 µL) comparable to that of a 1-cm conventional cell (80 µL). Despite the increase in optical path, the effect on sample dispersion was also similar to that attained in the commercial cell. The performance of the cell was assessed by the determination of phosphate based on the molybdenum blue method, yielding a linear response range between 0.05 and 0.8 mg L-1 phosphorus (r=0.999). The increase in sensitivity (30.4-fold) in comparison with that obtained with a conventional 1-cm flow cell agreed with that estimated by the Lambert-Beer law.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes the procedures for analysing pollutant gases emitted by engines, such as volatile organic compounds (benzene, toluene, ethylbenzene, o-xylene, m-xylene and p-xylene) by using high resolution gas chromatography (HRGC). For IC engine burning, in a broad sense, the use of the B10 mixture reduces drastically the emissions of aromatic compounds. Especially for benzene the reduction of concentrations occurs at the level of about 24.5%. Although a concentration value below 1 µg mL-1 has been obtained, this reduction is extremely significant since benzene is a carcinogenic compound.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Rare earth ion doped solid state materials are the most important active media of near-infrared and visible lasers and other photonic devices. In these ions, the occurrence of Excited State Absorptions (ESA), from long lived electronic levels, is commonplace. Since ESA can deeply affect the efficiencies of the rare earth emissions, evaluation of these transitions cross sections is of greatest importance in predicting the potential applications of a given material. In this paper a detailed description of the pump-probe technique for ESA measurements is presented, with a review of several examples of applications in Nd3+, Tm3+ and Er3+ doped materials.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Surface tension knowledge of surfactants aqueous solutions is important during amphiphilic molecule manufacturing and new product development, as feedback information to handle synthesis parameters to target performance. Drop counting method is an interesting simplification of drop weight method for surface tension measurements. A simple laboratory measurement device, with capability for temperature control, was assembled to allow investigation of ethoxylated surfactants. The implementation of the method was preceded by a detailed investigation of two factors that may affect the measured surface tension: drop formation velocity and surfactant ethoxylation degree. The limitations of the method are discussed on this basis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

One of the methodological resources that teachers use in a generalised way in Physical Education classes is the game. Inthis article we define the concept of game and analyse the characteristics of their internal structure. On the other hand welook at the concepts of physical condition and conditional skills and describe the objectives of its work in Primary Education.Finally, we relate these concepts and propose two practical examples of modifying the internal structure of the game so asto produce variations in the implied conditional skills

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aquest projecte té com a objectiu dotar de noves idees, o idees més concretes, el treball dels passatges d’orquestra, de cara a unes proves, principalment. Els passatges escollits són deu, els quals acostumen a demanar-se sempre en oposicions. La metodologia que he utilitzat a l’hora de desgranar els passatges es basa sobretot en la meva experiència personal, influenciada per molts professors i companys al llarg dels anys. Personalment m’ha servit per adonar-me, encara més, de la importància de l’estudi intel!ligent, treballant i analitzant trossos petits abans del passatge complet.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An undergraduate physical chemistry experiment based on the drop counting method for surface tension measurements is proposed to demonstrate adsorption isotherms of binary aqueous solutions of ethanol, n-propanol, and n-butanol. Excess surface is obtained by the derivative of surface tension taken with respect to alcohol activity, after this activity calculation using van Laar equation. Laboratory class contents are surface tension, excess surface, percolation of hydrogen bonds, micelle, activity, and ideal solution.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work is presented a versatile system for X-ray excited optical luminescence (XEOL) measurements. The apparatus was assembled from a sample holder connected to an optical fiber responsibly for the acquisition of the scintillation signal. The spectrum is registered with a CCD coupled in a spectrograph provided with diffraction gratings. The system performance was analyzed by exciting GdAlO3:Eu3+ 3.0 at.% with X-rays from a diffractometer and measuring the emission spectra. The system can be used to obtain precise and reliable spectroscopic properties of samples with various conformations without the loss of the required safety when dealing with ionizing radiations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Measurements at high temperature using liquid solutions require special cells and materials which are able to support the temperature and pressure developed inside. The constructed cell was designed to support pressures up to 20 bar, temperatures relatively high up to around 200 ºC, depending on the pressure developed inside the system. It also supports aggressive solutions since its inner wall is made of Teflon. The electrolyte has no contact with the metallic body of the cell. Then, it is supposed that this work represents a great contribution to the electrochemical studies of materials in solutions at high pressure and temperature

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple and reliable voltammetric method is presented for the determination of amitriptyline using a boron-doped diamond electrode in 0.1 mol L-1 sulfuric acid solution as the support electrolyte. Under optimized differential pulse voltammetry conditions (modulation time 5 ms, scan rate 70 mV s-1, and pulse amplitude 120 mV), the electrode provides linear responses to amitriptyline in the concentration range 1.05 to 92.60 µmol L-1 and at a detection limit of 0.52 µmol L-1. The proposed method was successfully applied in pharmaceutical formulations, with results similar to those obtained using UV-vis spectrophotometric method as reference (at 95% confidence level), as recommended by the Brazilian Pharmacopoeia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The measurement of nuclear magnetic resonance parameters in an anisotropic media, such as residual dipolar coupling (RDC), has proven to be an excellent methodology for the refinement of chemical structures, being used as a complementary tool in the determination of the relative configuration, conformation, and constitution of organic compounds. In this study, we applied this methodology to determine the relative configuration of α-santonin, a natural product with four stereocenters, while assigning its prochiral methylene protons using only the RDCs obtained in a polyacrylonitrile polymer gel swollen in DMSO-d6.