781 resultados para measuring bioimpedance


Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Physiological data obtained with the pulmonary artery catheter (PAC) are susceptible to errors in measurement and interpretation. Little attention has been paid to the relevance of errors in hemodynamic measurements performed in the intensive care unit (ICU). The aim of this study was to assess the errors related to the technical aspects (zeroing and reference level) and actual measurement (curve interpretation) of the pulmonary artery occlusion pressure (PAOP). METHODS: Forty-seven participants in a special ICU training program and 22 ICU nurses were tested without pre-announcement. All participants had previously been exposed to the clinical use of the method. The first task was to set up a pressure measurement system for PAC (zeroing and reference level) and the second to measure the PAOP. RESULTS: The median difference from the reference mid-axillary zero level was - 3 cm (-8 to + 9 cm) for physicians and -1 cm (-5 to + 1 cm) for nurses. The median difference from the reference PAOP was 0 mmHg (-3 to 5 mmHg) for physicians and 1 mmHg (-1 to 15 mmHg) for nurses. When PAOP values were adjusted for the differences from the reference transducer level, the median differences from the reference PAOP values were 2 mmHg (-6 to 9 mmHg) for physicians and 2 mmHg (-6 to 16 mmHg) for nurses. CONCLUSIONS: Measurement of the PAOP is susceptible to substantial error as a result of practical mistakes. Comparison of results between ICUs or practitioners is therefore not possible.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Over the last 4 years ADAMTS-13 measurement underwent dramatic progress with newer and simpler methods. AIMS: Blind evaluation of newer methods for their performance characteristics. DESIGN: The literature was searched for new methods and the authors invited to join the evaluation. Participants were provided with a set of 60 coded frozen plasmas that were prepared centrally by dilutions of one ADAMTS-13-deficient plasma (arbitrarily set at 0%) into one normal-pooled plasma (set at 100%). There were six different test plasmas ranging from 100% to 0%. Each plasma was tested 'blind' 10 times by each method and results expressed as percentage vs. the local and the common standard provided by the organizer. RESULTS: There were eight functional and three antigen assays. Linearity of observed-vs.-expected ADAMTS-13 levels assessed as r2 ranged from 0.931 to 0.998. Between-run reproducibility expressed as the (mean) CV for repeated measurements was below 10% for three methods, 10-15% for five methods and up to 20% for the remaining three. F-values (analysis of variance) calculated to assess the capacity to distinguish between ADAMTS-13 levels (the higher the F-value, the better the capacity) ranged from 3965 to 137. Between-method variability (CV) amounted to 24.8% when calculated vs. the local and to 20.5% when calculated vs. the common standard. Comparative analysis showed that functional assays employing modified von Willebrand factor peptides as substrate for ADAMTS-13 offer the best performance characteristics. CONCLUSIONS: New assays for ADAMTS-13 have the potential to make the investigation/management of patients with thrombotic microangiopathies much easier than in the past.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

High energy gamma rays can provide fundamental clues to the origins of cosmic rays. In this thesis, TeV gamma-ray emission from the Cygnus region is studied. Previously the Milagro experiment detected five TeV gamma-ray sources in this region and a significant excess of TeV gamma rays whose origin is still unclear. To better understand the diffuse excess the separation of sources and diffuse emission is studied using the latest and most sensitive data set of the Milagro experiment. In addition, a newly developed technique is applied that allows the energy spectrum of the TeV gamma rays to be reconstructed using Milagro data. No conclusive statement can be made about the spectrum of the diffuse emission from the Cygnus region because of its low significance of 2.2 σ above the background in the studied data sample. The entire Cygnus region emission is best fit with a power law with a spectral index of α=2.40 (68% confidence interval: 1.35-2.92) and a exponential cutoff energy of 31.6 TeV (10.0-251.2 TeV). In the case of a simple power law assumption without a cutoff energy the best fit yields a spectral index of α=2.97 (68% confidence interval: 2.83-3.10). Neither of these best fits are in good agreement with the data. The best spectral fit to the TeV emission from MGRO J2019+37, the brightest source in the Cygnus region, yields a spectral index of α=2.30 (68% confidence interval: 1.40-2.70) with a cutoff energy of 50.1 TeV (68% confidence interval: 17.8-251.2 TeV) and a spectral index of α=2.75 (68% confidence interval: 2.65-2.85) when no exponential cutoff energy is assumed. According to the present analysis, MGRO J2019+37 contributes 25% to the differential flux from the entire Cygnus at 15 TeV.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new approach, the four-window technique, was developed to measure optical phase-space-time-frequency tomography (OPSTFT). The four-window technique is based on balanced heterodyne detection with two local oscillator (LO) fields. This technique can provide independent control of position, momentum, time and frequency resolution. The OPSTFT is a Wigner distribution function of two independent Fourier transform pairs, phase-space and time-frequency. The OPSTFT can be applied for early disease detection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Testing a new method of nanoindentation using the atomic force microscope (AFM) was the purpose of this research. Nanoindentation is a useful technique to study the properties of materials on the sub-micron scale. The AFM has been used as a nanoindenter previously; however several parameters needed to obtain accurate results, including tip radius and cantilever sensitivity, can be difficult to determine. To solve this problem, a new method to determine the elastic modulus of a material using the atomic force microscope (AFM) has been proposed by Tang et al. This method models the cantilever and the sample as two springs in a series. The ratio of the cantilever spring constant (k) to diameter of the tip (2a) is treated in the model as one parameter (α=k/2a). The value of a, along with the cantilever sensitivity, are determined on two reference samples with known mechanical properties and then used to find the elastic modulus of an unknown sample. To determine the reliability and accuracy of this technique, it was tested on several polymers. Traditional depth-sensing nanoindentation was preformed for comparison. The elastic modulus values from the AFM were shown to be statistically similar to the nanoindenter results for three of the five samples tested.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: The aim of this retrospective study was to determine optimal duplex sonographic criteria for use in our institution for diagnosing severe carotid stenoses and to correlate those findings with angiographic measurements obtained by the European Carotid Surgery Trial (ECST), North American Symptomatic Carotid Endarterectomy Trial (NASCET), and Common Carotid (CC) methods of grading carotid stenoses. METHODS: We analyzed the angiographic data using the ECST, NASCET, and CC methods and compared the results with the duplex sonographic findings. We then calculated the sensitivity, specificity, positive and negative predictive values, and accuracy of the duplex sonographic method. Taking these parameters into account, the optimal intrastenotic peak systolic velocity (PSV) and end diastolic velocity (EDV) were derived for diagnosing severe stenoses according to the 3 angiographic methods. RESULTS: Optimal PSV and EDV values for diagnosing a 70% or greater stenosis in our laboratory were as follows: with the NASCET method of angiographic grading of stenoses, PSV 220 cm/second or greater and EDV 80 cm/second or greater, and with the ECST and CC methods, PSV 190 cm/second or greater, and EDV 65 cm/second or greater. The optimal PSV and EDV for diagnosing a stenosis of 80% or greater with the ECST grading method were 215 cm/second or greater and 90 cm/second or greater, respectively. CONCLUSIONS: Duplex sonography is a sensitive and accurate tool for evaluating severe carotid stenoses. Optimal PSVs and EDVs vary according to the angiographic method used to grade the stenosis. They are similar for stenoses 70% or greater with the NASCET method and for stenoses 80% or greater with the ECST method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Non-uniformity of steps within a flight is a major risk factor for falls. Guidelines and requirements for uniformity of step risers and tread depths assume the measurement system provides precise dimensional values. The state-of-the-art measurement system is a relatively new method, known as the nosing-to-nosing method. It involves measuring the distance between the noses of adjacent steps and the angle formed with the horizontal. From these measurements, the effective riser height and tread depth are calculated. This study was undertaken for the purpose of evaluating the measurement system to determine how much of total measurement variability comes from the step variations versus that due to repeatability and reproducibility (R&R) associated with the measurers. Using an experimental design quality control professionals call a measurement system experiment, two measurers measured all steps in six randomly selected flights, and repeated the process on a subsequent day. After marking each step in a flight in three lateral places (left, center, and right), the measurers took their measurement. This process yielded 774 values of riser height and 672 values of tread depth. Results of applying the Gage R&R ANOVA procedure in Minitab software indicated that the R&R contribution to riser height variability was 1.42%; and to tread depth was 0.50%. All remaining variability was attributed to actual step-to-step differences. These results may be compared with guidelines used in the automobile industry for measurement systems that consider R&R less than 1% as an acceptable measurement system; and R&R between 1% and 9% as acceptable depending on the application, the cost of the measuring device, cost of repair, or other factors.