987 resultados para manufacturing time


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The design of Internet Relay Chat (IRC) affords for, and itself produces, non-response situations that are not possible in FTF or telephone interaction. These system-occasioned nonresponses produce almost isomorphic stimuli to participant non-responses. Situations thus arise in which non-responses are interpersonally accountable despite agentive ambiguity. This study explores four intersections of participant-action and system-occasioned non-responses. An extension to Pomerantz's (1984b) 'pursuing a response' problems/solutions is proposed. The impact of IRC's design on its popularity is discussed in contrast to more recent chat systems. Suggestions are made for active and passive presence and non-response accounting features in future chat systems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Two varieties of adzuki beans (Vigna angularis), Bloodwood and Erimo, were stored at temperatures of 10, 20 or 30degreesC, and relative humidities (RH) 40 or 65%, and samples were analysed at 0, 1.5, 3 and 6 months. Storage at 30degreesC for > 1.5 months caused a significant decrease in the a(star) and b(star) colour values and darkening of the seed coat. Beans stored at 65% RH had lower L-star but higher a(star) and b(star) colour values than those stored at 40% RH. Bloodwood and Erimo samples showed similar trends in colour during storage. The best storage conditions for the preservation of the adzuki colour were 10degreesC and 65% RH. The Australian beans had lower L-star, a(star) and b(star) colour values than Japanese Erimo-shouzu beans and storage increased the difference.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Two varieties of adzuki grown in Australia, Bloodwood and Erimo, were stored for up to 6 months at three temperatures (10, 20 and 30 degreesC), and two relative humidities (RH; 40 and 65%). The amount of cell wall material increased with time under all storage conditions. This increase was greatest at 30 degreesC and 40% RH. Storage time and conditions did not affect the total pectin levels in the cell wall. Erimo constantly exhibited a higher total pectin level than Bloodwood. The Bloodwood soluble pectin, Ca++ and Mg++ and Erimo Ca++ in the cell wall remained stable during storage, while the Erimo soluble pectin and Mg++ exhibited a slight decrease at 20 and 30 degreesC after 3 months of storage. (C) 2002 Elsevier Science Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Are humans alone in their ability to reminisce about the past and imagine the future? Recent evidence suggests that food-storing birds (scrub jays) have access to information about what they have stored where and when. This has raised the possibility of mental time travel (MTT) in animals and sparked similar research with other species. Here we caution that such data do not provide convincing evidence for MTT. Examination of characteristics of human MTT (e.g. non-verbal declaration, generativity, developmental prerequisites) points to other avenues as to how a case for animal MTT could be made. In light of the current lack of evidence, however, we maintain that MTT is a uniquely human characteristic.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Rapid formation and selection of FP (few polyhedra) mutants occurs during serial passaging of Helicoverpa armigera nucleopolyhedrovirus (HaSNPV) in insect cell culture. The production of HaSNPV for use as biopesticides requires the passaging of the virus over a number of passages to produce enough virus inoculum for large-scale fermentation. During serial passaging in cell culture, FP mutants were rapidly selected, resulting in declined productivity and reduced potency of virus. Budded virus (BV) is usually harvested between 72 and 96 h postinfection (hpi) in order to obtain a high titer virus stock. In this study, the effect of tine of harvest (TOH) for BV on the selection rate of HaSNPV FP mutants during serial passaging was investigated. BV were harvested at different times postinfection, and each series was serially passaged for six passages. The productivity and percentage of FP mutants at each passage were determined. It was found that the selection of FP mutants can he reduced by employing an earlier TOH for BV. Serial passaging with BV harvested at 48 hpi showed a slower accumulation of FP mutants compared to that of BV harvested after 48 hpi. Higher cell specific yields were also maintained when BV were harvested at 48 hpi. When BV that were formed between 48 and 96 hpi were harvested and serially passaged, FP mutants quickly dominated the virus population. This suggests that the V formed and released between 48 and 96 hpi are most likely from FP mutant infected cells.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O soro de leite é um subproduto da fabricação do queijo, seja por acidificação ou por processo enzimático. Em condições ideais, a caseína do leite se agrega formando um gel, que posteriormente cortado, induz a separação e liberação do soro. É utilizado de diversas formas em toda a indústria alimentícia, possui rica composição em lactose, sais minerais e proteínas. A desidratação é um dos principais processos utilizados para beneficiamento e transformação do soro. Diante disto, o objetivo deste trabalho foi avaliar a influência dos métodos de secagem: liofilização, leito de espuma (nas temperaturas de 40, 50, 60, 70 e 80ºC) e spray-dryer (nas temperaturas de 55, 60, 65, 70 e 75ºC), sobre as características de umidade, proteína, cor e solubilidade do soro, bem como estudar o seu processo de secagem. O soro foi obtido e desidratado após concentração por osmose reversa, testando 11 tratamentos, em 3 repetições, utilizando um delineamento inteiramente casualizado. Os resultados demonstraram que o modelo matemático que melhor se ajustou foi o modelo de Page, apresentado um coeficiente de determinação ajustado acima de 0,98 e erro padrão da regressão em todas as temperaturas abaixo de 0,04 para o método por leito de espuma. Para o método de liofilização os respectivos valores foram 0,9975 e 0,01612. A partir disso, pode-se elaborar um modelo matemático generalizado, apresentando um coeficiente de determinação igual a 0,9888. No caso do leito de espuma, observou-se que à medida que se aumenta a temperatura do ar de secagem, o tempo de secagem diminui e os valores do coeficiente de difusão efetiva aumentam. Porém, a redução no tempo de secagem entre os intervalos de temperatura, diminui com o aumento da mesma. A energia de ativação para a difusão no processo de secagem do soro foi de 26,650 kJ/mol e para todas as avaliações físico-químicas e tecnológicas, a análise de variância apresentou um valor de F significativo (p<0,05), indicando que há pelo menos um contraste entre as médias dos tratamentos que é significativo.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The short article attempts to make some very brief reflections on the effects a lack of public policies positively discriminatory in terms of public employment retirement. In particular, the observation of the absurd contradiction between the average age of retirement at the time of death (for men and women) and the average pension time for men and women in public employment in Portugal.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: Precise needle puncture of the renal collecting system is an essential but challenging step for successful percutaneous nephrolithotomy. We evaluated the efficiency of a new real-time electromagnetic tracking system for in vivo kidney puncture. Materials and Methods: Six anesthetized female pigs underwent ureterorenoscopy to place a catheter with an electromagnetic tracking sensor into the desired puncture site and ascertain puncture success. A tracked needle with a similar electromagnetic tracking sensor was subsequently navigated into the sensor in the catheter. Four punctures were performed by each of 2 surgeons in each pig, including 1 each in the kidney, middle ureter, and right and left sides. Outcome measurements were the number of attempts and the time needed to evaluate the virtual trajectory and perform percutaneous puncture. Results: A total of 24 punctures were easily performed without complication. Surgeons required more time to evaluate the trajectory during ureteral than kidney puncture (median 15 seconds, range 14 to 18 vs 13, range 11 to 16, p ¼ 0.1). Median renal and ureteral puncture time was 19 (range 14 to 45) and 51 seconds (range 45 to 67), respectively (p ¼ 0.003). Two attempts were needed to achieve a successful ureteral puncture. The technique requires the presence of a renal stone for testing. Conclusions: The proposed electromagnetic tracking solution for renal collecting system puncture proved to be highly accurate, simple and quick. This method might represent a paradigm shift in percutaneous kidney access techniques

Relevância:

20.00% 20.00%

Publicador:

Resumo:

According to Wright [1] certification of products and processes began during the 1960’s in the manufacturing industry, as a tool to control and assure the quality/conformity of products and services provided by suppliers to customers/consumers. Thus, the series of ISO 9000 was published first time, in 1987 and it was been created with a flexible character, to be reviewed periodically. Later, were published others normative references, which highlight the ISO 14001 in 1996 and OHSAS 18001 in 1999. This was also, the natural sequence of the certification processes in the organizations, i.e., began with the certification of quality management systems (QMS) followed by the environmental management systems (EMS) and after for the Occupational Health and Safety Management System (OHSMS). Hence, a high percentage of organizations with an EMS, in accordance with the ISO 14001, had also implemented, a certified QMS, in accordance with ISO 9001. At first the implementation of a QMS was particularly relevant in high demanding activity sectors, like the automotive and aeronautical industries, but it has rapidly extended to every activity sector, becoming a common requisite of any company worldwide and a factor of competitiveness and survival. Due to the increasingly demanding environmental legislation in developed countries, companies nowadays are required to seriously take into consideration not only environmental aspects associated to the production chain itself, but also to the life cycle of their products.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Image segmentation is an ubiquitous task in medical image analysis, which is required to estimate morphological or functional properties of given anatomical targets. While automatic processing is highly desirable, image segmentation remains to date a supervised process in daily clinical practice. Indeed, challenging data often requires user interaction to capture the required level of anatomical detail. To optimize the analysis of 3D images, the user should be able to efficiently interact with the result of any segmentation algorithm to correct any possible disagreement. Building on a previously developed real-time 3D segmentation algorithm, we propose in the present work an extension towards an interactive application where user information can be used online to steer the segmentation result. This enables a synergistic collaboration between the operator and the underlying segmentation algorithm, thus contributing to higher segmentation accuracy, while keeping total analysis time competitive. To this end, we formalize the user interaction paradigm using a geometrical approach, where the user input is mapped to a non-cartesian space while this information is used to drive the boundary towards the position provided by the user. Additionally, we propose a shape regularization term which improves the interaction with the segmented surface, thereby making the interactive segmentation process less cumbersome. The resulting algorithm offers competitive performance both in terms of segmentation accuracy, as well as in terms of total analysis time. This contributes to a more efficient use of the existing segmentation tools in daily clinical practice. Furthermore, it compares favorably to state-of-the-art interactive segmentation software based on a 3D livewire-based algorithm.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The real Cloud and Ubiquitous Manufacturing systems require effectiveness and permanent availability of resources, their capacity and scalability. One of the most important problems for applications management over cloud based platforms, which are expected to support efficient scalability and resources coordination following SaaS implementation model, is their interoperability. Even application dashboards need to easily incorporate those new applications, their interoperability still remains a big problem to override. So, the possibility to expand these dashboards with efficiently integrated communicational cloud based services (cloudlets) represents a relevant added value as well as contributes to solving the interoperability problem. Following the architecture for integration of enriched existing cloud services, as instances of manufacturing resources, this paper: a) proposes a cloud based web platform to support dashboard integrating communicational services, and b) describe an experimentation to sustain the theory that the effective and efficient interoperability, especially in dynamic environments, could be achieved only with human intervention.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: Precise needle puncture of the renal collecting system is an essential but challenging step for successful percutaneous nephrolithotomy. We evaluated the efficiency of a new real-time electromagnetic tracking system for in vivo kidney puncture. Materials and Methods: Six anesthetized female pigs underwent ureterorenoscopy to place a catheter with an electromagnetic tracking sensor into the desired puncture site and ascertain puncture success. A tracked needle with a similar electromagnetic tracking sensor was subsequently navigated into the sensor in the catheter. Four punctures were performed by each of 2 surgeons in each pig, including 1 each in the kidney, middle ureter, and right and left sides. Outcome measurements were the number of attempts and the time needed to evaluate the virtual trajectory and perform percutaneous puncture. Results: A total of 24 punctures were easily performed without complication. Surgeons required more time to evaluate the trajectory during ureteral than kidney puncture (median 15 seconds, range 14 to 18 vs 13, range 11 to 16, p ¼ 0.1). Median renal and ureteral puncture time was 19 (range 14 to 45) and 51 seconds (range 45 to 67), respectively (p ¼ 0.003). Two attempts were needed to achieve a successful ureteral puncture. The technique requires the presence of a renal stone for testing. Conclusions: The proposed electromagnetic tracking solution for renal collecting system puncture proved to be highly accurate, simple and quick. This method might represent a paradigm shift in percutaneous kidney access techniques.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Precise needle puncture of renal calyces is a challenging and essential step for successful percutaneous nephrolithotomy. This work tests and evaluates, through a clinical trial, a real-time navigation system to plan and guide percutaneous kidney puncture. Methods: A novel system, entitled i3DPuncture, was developed to aid surgeons in establishing the desired puncture site and the best virtual puncture trajectory, by gathering and processing data from a tracked needle with optical passive markers. In order to navigate and superimpose the needle to a preoperative volume, the patient, 3D image data and tracker system were previously registered intraoperatively using seven points that were strategically chosen based on rigid bone structures and nearby kidney area. In addition, relevant anatomical structures for surgical navigation were automatically segmented using a multi-organ segmentation algorithm that clusters volumes based on statistical properties and minimum description length criterion. For each cluster, a rendering transfer function enhanced the visualization of different organs and surrounding tissues. Results: One puncture attempt was sufficient to achieve a successful kidney puncture. The puncture took 265 seconds, and 32 seconds were necessary to plan the puncture trajectory. The virtual puncture path was followed correctively until the needle tip reached the desired kidney calyceal. Conclusions: This new solution provided spatial information regarding the needle inside the body and the possibility to visualize surrounding organs. It may offer a promising and innovative solution for percutaneous punctures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hand and finger tracking has a major importance in healthcare, for rehabilitation of hand function required due to a neurological disorder, and in virtual environment applications, like characters animation for on-line games or movies. Current solutions consist mostly of motion tracking gloves with embedded resistive bend sensors that most often suffer from signal drift, sensor saturation, sensor displacement and complex calibration procedures. More advanced solutions provide better tracking stability, but at the expense of a higher cost. The proposed solution aims to provide the required precision, stability and feasibility through the combination of eleven inertial measurements units (IMUs). Each unit captures the spatial orientation of the attached body. To fully capture the hand movement, each finger encompasses two units (at the proximal and distal phalanges), plus one unit at the back of the hand. The proposed glove was validated in two distinct steps: a) evaluation of the sensors’ accuracy and stability over time; b) evaluation of the bending trajectories during usual finger flexion tasks based on the intra-class correlation coefficient (ICC). Results revealed that the glove was sensitive mainly to magnetic field distortions and sensors tuning. The inclusion of a hard and soft iron correction algorithm and accelerometer and gyro drift and temperature compensation methods provided increased stability and precision. Finger trajectories evaluation yielded high ICC values with an overall reliability within application’s satisfying limits. The developed low cost system provides a straightforward calibration and usability, qualifying the device for hand and finger tracking in healthcare and animation industries.