860 resultados para laboratory tests
Resumo:
Introduction: Polycystic ovary syndrome (PCOS) whose classic features (menstrual irregularity of oligo/ amenorrhea type, chronic anovulation, infertility and hyperandrogenism clinical and/ or biochemical), is associated with aspects of metabolic syndrome (MS), as obesity and insulin resistance. The level of obesity determines different levels of inflammation, increasing cytokines participants of metabolic and endocrine functions, beyond modulate the immune response. Metabolic changes, added to the imbalance of sex hormones underlying irregular menstruation observed in (PCOS) can trigger allergic processes and elevation of total and specific IgE antibodies indicate that a sensitization process was started. Objective: To evaluate the influence of PCOS on biochemical parameters and levels of total and specific IgE to aeroallergens in obese women. Methods: After approval by the Committee of Ethics in Research, were recruited 80 volunteers with BMI ≥ 30 kg/m2 and age between 18 and 45 years. Among these, 40 with PCOS according to the Rotterdam criteria and 40 women without PCOS (control group). All participants were analysed with regard to anthropometric, clinical, gynecological parameters, interviewed using a questionnaire, and underwent blood sampling for realization of laboratory tests of clinical biochemistry: Total cholesterol, LDL-cholesterol, HDL- cholesterol, Triglycerides, Fasting glucose, Urea, Creatinine, Aspartate aminotransferase (AST), Alanine aminotransferase (ALT) and immunological: total and specific IgE to Dermatophagoides pteronyssinus, Blomia tropicalis, Dermatophagoides farinae and Dermatophagoides microceras.Statistical analysis was performed using SPSS 15.0 software through the chi-square tests, Fisher, Student t test and binary logistic regression, with significance level (p <0.05). Results: It was observed in the group of obese women with PCOS that 29 (72.5%) had menstrual cycle variable and 27 (67.5%) had difficulty getting pregnant. According to waist-hip ratio, higher average was also observed in obese PCOS (0.87). Blood level of HDL (36.9 mg/dL) and ALT (29.3 U/L) were above normal levels in obese women with PCOS, with statistically significant relationship. In the analysis of total and specific IgE to D. pteronyssinus high results were also prevalent in obese PCOS, with blood level (365,22 IU/mL) and (6.83 kU/L), respectively, also statistically significant. Conclusions: Observed predominance of cases with high levels of total IgE in the group of obese women with PCOS, 28 (70%) of the participants, whose mean blood concentration of the group was 365.22 IU/mL. In the analysis of Specific IgE between the groups, the allergen Dermatophagoides pteronyssinus showed greater dispersion and average the results of sensitization in the group of obese PCOS, whose mean blood concentration was 6.83 kU/l. Keywords: Obesity, Allergens and Polycystic Ovary Syndrome
Resumo:
The drilling of wells for petroleum extraction generates rocks and soils fragments, among other residues. These fragments are denominated petroleum drilling gravel or simply petroleum drilling residue. On the sites of onshore exploration are formed big deposits of drilling gravel, an expensive final destination material. This work aims at evaluating the addition of drilling residue to a lateritic soil, as composite material, for construction of compacted fills for earth work projects. Soil and residue were evaluated by X-ray diffraction (XRD) and X-ray fluorescence (XRF) and by laboratory tests traditionally used in soil mechanics, as particle-size analysis of soils, determination of liquid and plasticity indexes and compaction test. After soil and residue characterization, soil-residue mixtures were studied, using dosages of 2,5%, 5%, 10%, and 15% of residue in relation to the dry soil mass. These mixtures were submitted to compaction test, CBR, direct shear test and consolidation test. The test results were compared to the current legislation of DNIT for compacted fill construction. The results showed that the mixtures presented the minimal necessary parameters, allowing, from the point of view of geotechnical analysis, the use of these mixtures for construction of compacted fills
Resumo:
This work describes the synthesis and study of the application of a new surfactant (Triester Lipophilic – TEL) obtained by citric acid with octanol. It is reaction was followed by thin layer chromatography (TLC) and after purification the product was characterized by proton and 13 – carbon nuclear magnetic resonance spectroscopy ( H and 13C NMR), thermogravimetric analysis (TGA) and surface tension analysis of oil-in-water emulsions. The TEL performance as surfactant in ester, n-paraffin and biodiesel based drilling fluids on the 70/30 and 60/40 water- oil rations (WOR) was evaluated by comparative tests of two commercial products used in the fields. These drilling fluids were aged in roller oven at 200 0 F during 16 h. The rheological and electric stability measurements were carried out at 135 ºF, the phase separation was evaluated after seven days at rest and the filtrate volume of drilling fluids was determined at high temperature and high pressure. The rheological behavior of the drilling fluids was evaluated by the flow curves. The results showed that the drilling fluids studied here presented Binghamian behavior as well as the used in the oil fields. The laboratory tests showed that the TEL reduced the filtrate volume and promoted the enhance of the thermal and mechanical stabilities.
Resumo:
Electrical disturbances such as voltage sags, interruptions and voltage unbalances might cause serious problems for the end-user and for the companies of generation and transmission of energy. Few years ago, those companies have been using methods and equipments of protection to avoid the disturbances’ presence or to mitigate their effects on the power system. Disturbances generators are used to analyse the behavior of electrical and electronic equipments affected by disturbances. The analysis of those failures allows the development of appropriated protection equipments. In this paper, the development of a disturbances generator based on power converters is presented. The disturbance generator developed is able to generate some symmetrical disturbances, such as: voltage sags, voltage swells and harmonic distortion. The control strategy used in the disturbance generator is based on discrete and repetitive control. The steps of the design of the control and of the filter used for reducing harmonic in the output, are detailed in the text. Are presented the obtained results on computational simulations and the obtained results on laboratory tests.
Resumo:
Maternal and infant mortality have become a serious public health problem in Brazil, especially in northeasternand northern regions.In RioGrande do Norte, the high rates ofdeathsofmothersandbabies haveconcerned not onlythehealthauthorities andjusticeagenciessuch as the prosecution service. In 2011, State Public Ministry (MPE) has developed a proposition which was called “Nascer com Dignidade”, focused on the monitoring ofcare givenin prenatal, childbirth andpost childbirthin the cities. The aim of thisstudy was toinvestigate how the intervention of MPE works in maternal and child care. The method adopted to survey data was the case study by analyzing the skills of the reports which were carried out in four of the eight Public Health Regional Units (URSAP).A total of 26municipalities were chosenand the results showfragilityparticularly inprenatal care which can result in complicationsin childbirthand postpartumlike:incomplete health family teams(in05cities), lack of access orinaccessibility to laboratory tests(16 cities) and lack of the pregnant woman'sattachment to thebirthing place(in26 cities). Based on this reality, MPE has adopted relevant attitudes as filing public civil suits, compliance of Conduct Adjustment Declaration in the municipal management and performing interventions in heath care centers and maternity clinics of the state. Thereforeit is known thatPublic Ministryis of paramount importanceto indicatethe necessaryadjustmentsto addressinfant and maternalmortalityin the state (mean of 65/100,000 and16/100,000respectively) and give the city hall the responsibility for the health care quality provided to their citizens. These factors demand theprinciples ofuniversality and integrality to be performed in order to reduce social inequities.
Resumo:
The study aims to analyze the content and measures of accuracy of the nursing diagnosis Ineffective Self Health in patients undergoing hemodialysis. Study of nursing diagnosis validation carried out in two stages, namely: content analysis by judges and accuracy of clinical indicators. In the first stage, 22 judges evaluated the setting and location of the diagnosis, clinical indicators and etiological factors and their conceptual and empirical definitions. We used the binomial test to determine the proportion of the judges of the relevance of the components of the nursing diagnosis. In the second stage, we used the Latent Class Analysis for the diagnostic accuracy by evaluating 200 patients in a hemodialysis clinic in northeastern Brazil. Research approved by the Ethics Committee, under the Opinion No 387 837 and CAAE 18486413.0.0000.5537. The results show that the judges evaluated as pertinent clinical indicators 12 and 22 etiological factors. Proposed amendment of the nomenclature of five indicators and six factors and the implementation of a clinical indicator for etiology and three etiological factors for clinical indicators. In conceptual and empirical definitions, judges judged as not relevant the conceptual and empirical definitions of a clinical indicator, the conceptual definitions of two etiological factors and empirical definitions four etiological factors. Still, changes were suggested in the conceptual and empirical definitions of two clinical indicators, the conceptual definitions of 12 etiological factors and empirical definitions of 11 etiological factors. Clinical indicators analyzed in the first stage were validated clinically in patients undergoing hemodialysis. The most frequent clinical indicators were Changes in laboratory tests (100%) and daily life choices ineffective to achieve health goals (81%); and three etiological factors had a higher frequency, they are: unfavorable demographic factors (94.5%), beliefs (79%) and comorbidities (77.5%). From Latent class analysis, diagnosis prevalence was estimated at 66.28%. Clinical indicators that showed the best sensitivity measures for the nursing diagnosis Ineffective Self Health were: daily life choices ineffective to achieve health goals and Expression of difficulty with prescribed regimens. In turn, the clinical indicators of inappropriate medication use, no expression of desire to control the disease, irregular attendance to the dialysis sessions and infection were more specific as to that diagnosis. Non-adherence to treatment was the only indicator that showed confidence intervals with values for sensitivity and specificity, statistically above 0.5, being the one who has better diagnostic accuracy as the inference of the nursing diagnosis Ineffective Self Health in hemodialysis clientele. Thus, it is believed that the improvement of the components of diagnosis in question will contribute to the development of more reliable nursing interventions to the health status of the individual in hemodialysis, providing a more scientifically qualified care.
Resumo:
The study aims to analyze the content and measures of accuracy of the nursing diagnosis Ineffective Self Health in patients undergoing hemodialysis. Study of nursing diagnosis validation carried out in two stages, namely: content analysis by judges and accuracy of clinical indicators. In the first stage, 22 judges evaluated the setting and location of the diagnosis, clinical indicators and etiological factors and their conceptual and empirical definitions. We used the binomial test to determine the proportion of the judges of the relevance of the components of the nursing diagnosis. In the second stage, we used the Latent Class Analysis for the diagnostic accuracy by evaluating 200 patients in a hemodialysis clinic in northeastern Brazil. Research approved by the Ethics Committee, under the Opinion No 387 837 and CAAE 18486413.0.0000.5537. The results show that the judges evaluated as pertinent clinical indicators 12 and 22 etiological factors. Proposed amendment of the nomenclature of five indicators and six factors and the implementation of a clinical indicator for etiology and three etiological factors for clinical indicators. In conceptual and empirical definitions, judges judged as not relevant the conceptual and empirical definitions of a clinical indicator, the conceptual definitions of two etiological factors and empirical definitions four etiological factors. Still, changes were suggested in the conceptual and empirical definitions of two clinical indicators, the conceptual definitions of 12 etiological factors and empirical definitions of 11 etiological factors. Clinical indicators analyzed in the first stage were validated clinically in patients undergoing hemodialysis. The most frequent clinical indicators were Changes in laboratory tests (100%) and daily life choices ineffective to achieve health goals (81%); and three etiological factors had a higher frequency, they are: unfavorable demographic factors (94.5%), beliefs (79%) and comorbidities (77.5%). From Latent class analysis, diagnosis prevalence was estimated at 66.28%. Clinical indicators that showed the best sensitivity measures for the nursing diagnosis Ineffective Self Health were: daily life choices ineffective to achieve health goals and Expression of difficulty with prescribed regimens. In turn, the clinical indicators of inappropriate medication use, no expression of desire to control the disease, irregular attendance to the dialysis sessions and infection were more specific as to that diagnosis. Non-adherence to treatment was the only indicator that showed confidence intervals with values for sensitivity and specificity, statistically above 0.5, being the one who has better diagnostic accuracy as the inference of the nursing diagnosis Ineffective Self Health in hemodialysis clientele. Thus, it is believed that the improvement of the components of diagnosis in question will contribute to the development of more reliable nursing interventions to the health status of the individual in hemodialysis, providing a more scientifically qualified care.
Resumo:
Eutrophication is the most common cause of water quality degradation in the world. This process occurs by excessive nutrients inputs, nitrogen and phosphorus, to the aquatic systems resulting in algal and cyanobacterial blooms. In shallow lakes these effects are pronounced due to the higher interaction of the lake with watershed, air and sediment. There are innumerous restoration techniques of eutrophied lakes with a range of successful results but there is only one case of successful lake restoration in Brazil: Paranoá Lake in Brasília city. The Brazilian semiarid region has many artificial lakes, named açudes, which are mostly eutrophic and shallow lakes. The eutrophication in these lakes is reported and the phytoplankton community is dominated by potentially toxic cyanobacteria species, mainly Cylindrospermopsis raciborskii. The aim of this thesis is to test techniques for water quality management which can be easily applied in Brazilian semiarid lakes. Results from a laboratory experiment suggest that the addition of a phosphorus sorbent clay associated with an aluminium based coagulant is an effective technique in removing soluble reactive phosphorus and reducing C. raciborskii growth rate – cyanobacteria potentially toxic dominant in reservoirs of Brazilian semiarid – but this effect is dependent on the biomass in the application moment. Results from a field experiment in mesocosm in a eutrophied lake showed that the addition of aluminium based coagulant and removal of benthivorous fish is more efficient in removing total phosphorus and chlorophyll-a from water column than the isolated application of one of the techniques. Lastly, laboratory tests showed that aluminium based coagulant exhibited good performance in removing turbidity and total phosphorus from water of six reservoirs but the efficiency was reduced by algal biomass and pH. The results of this study showed that the improvement in water quality of eutrophied reservoirs in semiarid region is possible through internal loading control by phosphorus precipitation and inactivation in sediments or inhibition of phosphorus release by benthivorous fishes, and also that these results show are additives in water quality improvement.
Resumo:
Eutrophication is the most common cause of water quality degradation in the world. This process occurs by excessive nutrients inputs, nitrogen and phosphorus, to the aquatic systems resulting in algal and cyanobacterial blooms. In shallow lakes these effects are pronounced due to the higher interaction of the lake with watershed, air and sediment. There are innumerous restoration techniques of eutrophied lakes with a range of successful results but there is only one case of successful lake restoration in Brazil: Paranoá Lake in Brasília city. The Brazilian semiarid region has many artificial lakes, named açudes, which are mostly eutrophic and shallow lakes. The eutrophication in these lakes is reported and the phytoplankton community is dominated by potentially toxic cyanobacteria species, mainly Cylindrospermopsis raciborskii. The aim of this thesis is to test techniques for water quality management which can be easily applied in Brazilian semiarid lakes. Results from a laboratory experiment suggest that the addition of a phosphorus sorbent clay associated with an aluminium based coagulant is an effective technique in removing soluble reactive phosphorus and reducing C. raciborskii growth rate – cyanobacteria potentially toxic dominant in reservoirs of Brazilian semiarid – but this effect is dependent on the biomass in the application moment. Results from a field experiment in mesocosm in a eutrophied lake showed that the addition of aluminium based coagulant and removal of benthivorous fish is more efficient in removing total phosphorus and chlorophyll-a from water column than the isolated application of one of the techniques. Lastly, laboratory tests showed that aluminium based coagulant exhibited good performance in removing turbidity and total phosphorus from water of six reservoirs but the efficiency was reduced by algal biomass and pH. The results of this study showed that the improvement in water quality of eutrophied reservoirs in semiarid region is possible through internal loading control by phosphorus precipitation and inactivation in sediments or inhibition of phosphorus release by benthivorous fishes, and also that these results show are additives in water quality improvement.
Resumo:
There is a bidirectional association between periodontal disease (PD) and diabetes mellitus, in which diabetes favors the development of PD and PD, if left untreated, can worsen the metabolic control of diabetes. Thus, periodontal disease should be treated to restore periodontal health and reduce the complications of diabetes. Therefore, the objective is assess the effect of full mouth periodontal therapy decontamination (Full Mouth Desinfection - FMD) in diabetic type II patients with chronic periodontitis during 12 months. Thirty-one patients in group one (G1) and 12 in group two (G2) were followed at baseline, 03, 06 09 and 12 months. There following clinical parameters were accessed: probing on bleeding (BOP), visible plaque index (PI), probing depth (PD), clinical attachment level (CAL) and gingival recession (GR). For diabetic patients, there were also made laboratory tests to evaluate blood parameters: fasting glucose and glycated hemoglobin. The results had been analyzed in two ways: all sites in the mouth and another with diseased sites. The Mann-Whitney, Friedman and Wilcoxon tests were used with 5% significance. Intergroup analysis of all sites it is clear that there was no significant difference over time concerning PD, BOP, PI, CAL and RG. However, when evaluating the diseased sites, we observed significant difference for CAL and PD, with higher values in G1. The intragroup analysis for all sites showed a statistically significant reduction at PD, PI and BOP in both groups. Intragroup analysis of periodontal affected sites showed a statistically significant reduction in PD, BOP and CAL in both groups. There was also a statistically significant increase in RG values. There was no significant change concerning glycated hemoglobin and fasting glucose in the G1. Therefore, it can be concluded that there were improvements in periodontal parameters over the 12 months of research, but without changes in glycemic levels of diabetic patients. Thus, periodontal therapy proved effective in maintaining oral health.
Resumo:
Due to relative ground movement, buried pipelines experience geotechnical loads. The imposed geotechnical loads may initiate pipeline deformations that affect system serviceability and integrity. Engineering guidelines (e.g., ALA, 2005; Honegger and Nyman, 2001) provide the technical framework to develop idealized structural models to analyze pipe‒soil interaction events and assess pipe mechanical response. The soil behavior is modeled using discrete springs that represent the geotechnical loads per unit pipe length developed during the interaction event. Soil forces are defined along three orthogonal directions (i.e., axial, lateral and vertical) to analyze the response of pipelines. Nonlinear load-displacement relationships of soil defined by a spring, is independent of neighboring spring elements. However, recent experimental and numerical studies demonstrate significant coupling effects during oblique (i.e., not along one of the orthogonal axes) pipe‒soil interaction events. In the present study, physical modeling using a geotechnical centrifuge was conducted to improve the current understanding of soil load coupling effects of buried pipes in loose and dense sand. A section of pipeline, at shallow burial depth, was translated through the soil at different oblique angles in the axial-lateral plane. The force exerted by the soil on pipe is critically examined to assess the significance of load coupling effects and establish a yield envelope. The displacements required to soil yield force are also examined to assess potential coupling in mobilization distance. A set of laboratory tests were conducted on the sand used for centrifuge modeling to find the stress-strain behavior of sand, which was used to examine the possible mechanisms of centrifuge model test. The yield envelope, deformation patterns, and interpreted failure mechanisms obtained from centrifuge modeling are compared with other physical modeling and numerical simulations available in the literature.
Resumo:
The dynamical evolution of dislocations in plastically deformed metals is controlled by both deterministic factors arising out of applied loads and stochastic effects appearing due to fluctuations of internal stress. Such type of stochastic dislocation processes and the associated spatially inhomogeneous modes lead to randomness in the observed deformation structure. Previous studies have analyzed the role of randomness in such textural evolution but none of these models have considered the impact of a finite decay time (all previous models assumed instantaneous relaxation which is "unphysical") of the stochastic perturbations in the overall dynamics of the system. The present article bridges this knowledge gap by introducing a colored noise in the form of an Ornstein-Uhlenbeck noise in the analysis of a class of linear and nonlinear Wiener and Ornstein-Uhlenbeck processes that these structural dislocation dynamics could be mapped on to. Based on an analysis of the relevant Fokker-Planck model, our results show that linear Wiener processes remain unaffected by the second time scale in the problem but all nonlinear processes, both Wiener type and Ornstein-Uhlenbeck type, scale as a function of the noise decay time τ. The results are expected to ramify existing experimental observations and inspire new numerical and laboratory tests to gain further insight into the competition between deterministic and random effects in modeling plastically deformed samples.
Resumo:
Pipelines extend thousands of kilometers across wide geographic areas as a network to provide essential services for modern life. It is inevitable that pipelines must pass through unfavorable ground conditions, which are susceptible to natural disasters. This thesis investigates the behaviour of buried pressure pipelines experiencing ground distortions induced by normal faulting. A recent large database of physical modelling observations on buried pipes of different stiffness relative to the surrounding soil subjected to normal faults provided a unique opportunity to calibrate numerical tools. Three-dimensional finite element models were developed to enable the complex soil-structure interaction phenomena to be further understood, especially on the subjects of gap formation beneath the pipe and the trench effect associated with the interaction between backfill and native soils. Benchmarked numerical tools were then used to perform parametric analysis regarding project geometry, backfill material, relative pipe-soil stiffness and pipe diameter. Seismic loading produces a soil displacement profile that can be expressed by isoil, the distance between the peak curvature and the point of contraflexure. A simplified design framework based on this length scale (i.e., the Kappa method) was developed, which features estimates of longitudinal bending moments of buried pipes using a characteristic length, ipipe, the distance from peak to zero curvature. Recent studies indicated that empirical soil springs that were calibrated against rigid pipes are not suitable for analyzing flexible pipes, since they lead to excessive conservatism (for design). A large-scale split-box normal fault simulator was therefore assembled to produce experimental data for flexible PVC pipe responses to a normal fault. Digital image correlation (DIC) was employed to analyze the soil displacement field, and both optical fibres and conventional strain gauges were used to measure pipe strains. A refinement to the Kappa method was introduced to enable the calculation of axial strains as a function of pipe elongation induced by flexure and an approximation of the longitudinal ground deformations. A closed-form Winkler solution of flexural response was also derived to account for the distributed normal fault pattern. Finally, these two analytical solutions were evaluated against the pipe responses observed in the large-scale laboratory tests.
Resumo:
Allergic rhinitis is one of the most common clinical conditions in children; however, data regarding the safety of antihistamines in children with seasonal allergic rhinitis are limiting. To evaluate the safety and efficacy of fexofenadine in children with seasonal allergic rhinitis, data were pooled from three, double-blind, randomized, placebo-controlled, parallel-group, 2-week trials in children (6-11 year) with seasonal allergic rhinitis. All studies assessed fexofenadine HCl 30 mg b.i.d.; two studies included fexofenadine HCl at 15 and 60 mg b.i.d. Patients (and investigators) reported any adverse events during the trial. Physical examinations, including measurements of vital signs and laboratory tests, were performed. Efficacy assessments (total symptom score and individual symptom scores) were evaluated. Exposure to fexofenadine HCl 30 mg b.i.d. and to any fexofenadine dose exceeded 10,000 and 17,000 patient days, respectively. Incidences of adverse events, and discontinuations because of adverse events, were low and similar across treatment groups. In the placebo group, 24.4% of subjects reported adverse events compared with 24.1% for fexofenadine HCl 30 mg b.i.d., and 28.4% for all fexofenadine-treated groups. The most common adverse event overall was headache (4.3% placebo; 5.8% fexofenadine HCl 30 mg b.i.d.; and 7.2% any fexofenadine doses). Treatment-related adverse events were similar across treatment groups with no sedative effects. Fexofenadine HCl 30 mg b.i.d. was significantly superior to placebo in reducing the total symptom score and all individual seasonal allergic rhinitis symptoms, including nasal congestion (p < 0.05). Fexofenadine, at doses of up to 60 mg b.i.d., is safe and non-sedating, and fexofenadine HCl 30 mg b.i.d. effectively reduces all seasonal allergic rhinitis symptoms in children aged 6-11 years.
Resumo:
Compared to the use of traditional fossil fuels (coal, oil, natural gas), combustion of biomass and waste fuels has several environmental and economic advantages for heat and power generation. However, biomass and waste fuels might contain halogens (Cl, Br, F), alkali metals (Na, K) and heavy metals (Zn, Pb), which may cause harmful emissions and corrosion problems. Hightemperature corrosion occurs typically on furnace waterwalls and superheaters. The corrosion of the boiler tube materials limits the increase of thermal efficiency of steam boilers and leads to costly shutdowns and repairs. In recent years, some concerns have been raised about halogen (Cl, Br, and F)-related hightemperature corrosion in biomass- and waste-fired boilers. Chlorine-related high-temperature corrosion has been studied extensively. The presence of alkali chlorides in the deposits is believed to play a major role in the corrosion observed in biomass and waste fired boilers. However, there is much less information found in literature on the corrosion effect of bromine and fluorine. According to the literature, bromine is only assumed to play a role similar to chlorine; the role of fluorine is even less understood. In this work, a series of bubbling fluidized bed (BFB) bench-scale tests were carried out to characterize the formation and sulfation behaviors of KCl and KBr in BFB combustion conditions. Furthermore, a series of laboratory tests were carried out to investigate the hightemperature corrosion behaviors of three different superheater steels (10CrMo9-10, AISI 347 and Sanicro 28) exposed to potassium halides in ambient air and wet air (containing 30% H2O). The influence of H2O and O2 on the high-temperature corrosion of steels both with and without a salt (KCl) in three gas atmospheres (2% H2O-30% O2-N2, 2% H2O-2% O2-N2 and 30% H2O-2% O2-N2) was also studied. From the bench-scale BFB combustion tests, it was found that HBr has a clearly higher affinity for the available K forming KBr than HCl forming KCl. The tests also indicated that KCl has a higher tendency for sulfation than KBr. From the laboratory corrosion tests in ambient air (also called “dry air” in Paper III and Paper IV), it was found that at relatively low temperatures (≤ 550 °C) the corrosivity of KBr and KF are similar to KCl. At 600 °C, KF showed much stronger corrosivity than KBr and KCl, especially for 10CrMo9-10 and AISI 347. When exposed to KBr or KF, 10CrMo9-10 was durable at least up to 450 °C, while AISI 347 and Sanicro 28 were durable at least up to 550 °C. From the laboratory corrosion tests in wet air (30% H2O), no obvious effect of water vapor was detected at 450 °C. At 550 °C, the influence of water vapor became significant in some cases, but the trend was not consistent. At 550 °C, after exposure with KBr, 10CrMo9-10 suffered from extreme corrosion; after exposure with KF and KCl, the corrosion was less severe, but still high. At 550 °C, local deep pitting corrosion occurred on AISI 347 and Sanicro 28 after exposure with KF. Some formation of K2CrO4 was observed in the oxide layer. At 550 °C, AISI 347 and Sanicro 28 suffered from low corrosion (oxide layer thickness of < 10 μm) after exposure with KBr and KCl. No formation of K2CrO4 was observed. Internal oxidation occurred in the cases of AISI 347 with KBr and KCl. From the laboratory corrosion tests in three different gas atmospheres (2% H2O-30% O2-N2, 2% H2O-2% O2-N2 and 30% H2O-2% O2-N2), it was found that in tests with no salt, no corrosion occurred on AISI 347 and Sanicro 28 up to 600 °C in both the “O2-rich” (2% H2O-30% O2-N2) and “H2O-rich” (30% H2O-2% O2-N2) gas atmospheres; only 10CrMo9-10 showed increased corrosion with increasing temperature. For 10CrMo9-10 in the “O2-rich” atmosphere, the presence of KCl significantly increased the corrosion compared to the “no salt” cases. For 10CrMo9-10 in the “H2O-rich” atmosphere, the presence or absence of KCl did not show any big influence on corrosion. The formation of K2CrO4 was observed only in the case with the “O2-rich” atmosphere. Considering both the results from the BFB tests and the laboratory corrosion tests, if fuels containing Br were to be combusted, the corrosion damage of superheaters would be expected to be higher than if the fuels contain only Cl. Information generated from these studies can be used to help the boiler manufacturers in selecting materials for the most demanding combustion systems.