990 resultados para joint motion


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Spiral chemical waves subjected to a spatiotemporal random excitability are experimentally and numerically investigated in relation to the light-sensitive Belousov-Zhabotinsky reaction. Brownian motion is identified and characterized by an effective diffusion coefficient which shows a rather complex dependence on the time and length scales of the noise relative to those of the spiral. A kinematically based model is proposed whose results are in good qualitative agreement with experiments and numerics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this guide is to help practitioners understand how to optimize concrete pavement joint performance through the identification, mitigation, and prevention of joint deterioration. It summarizes current knowledge from research and practice to help practitioners access the latest knowledge and implement proven techniques. Emphasizing that water is the common factor in most premature joint deterioration, this guide describes various types of joint deterioration that can occur. Some distresses are caused by improper joint detailing or construction, and others can be attributed to inadequate materials or proportioning. D cracking is a form of joint distress that results from the use of poor-quality aggregates. A particular focus in this guide is joint distress due to freeze-thaw action. Numerous factors are at play in the occurrence of this distress, including the increased use of a variety of deicing chemicals and application strategies. Finally, this guide provides recommendations for minimizing the potential for joint deterioration, along with recommendations for mitigation practices to slow or stop the progress of joint deterioration.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Between January 1996 and July 2003, 93 consecutive patients operated on with a diagnosis of olecranon fractures were identified from our trauma unit files. Fourteen transolecranon fracture-dislocations were found after a retrospective X-radiographic evaluation. Eight patients were women and six were men, with a mean age of 54 years. There were 4 noncomminuted olecranon fractures, treated with K-wires and single tension-band wiring. The remaining 10 fractures were complex fractures, treated in 3 cases with multiple K-wires and single tension-band wiring, in 2 by use of one-third tubular plates, in 1 with a 3.5-mm dynamic compression plate, and in the remaining 4 with 3.5-mm reconstruction plates. Ligament repair was not performed in any case. Three patients needed reoperation because of early failure of primary fixation. Patients were reviewed at a mean follow-up of 3.6 years. Two reported difficulties in daily activities, none with any symptoms of elbow instability. According to the Broberg and Morrey score, 4 patients had excellent results, 6 had good results, 2 had fair results, and 2 had poor results. Four patients showed signs of degenerative arthritis on the radiographs obtained at follow-up. We conclude that transolecranon fracture-dislocation is an underreported and misdiagnosed injury. Various fixation techniques can restore the anatomic relationships and contour of the trochlear notch; the imperative goal is to obtain a good stable primary fixation and allow early active mobilization.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Infection of total hip arthroplasties (THA) leads to significant long-termmorbidity and high healthcare costs. We evaluated the differentreasons for treatment failure using different surgical modalities in a12-year prosthetic joint infection cohort study.Method: All patients hospitalized at our institution with infected THAwere included either retrospectively (1999-2007) or prospectively(2008-2010). THA infection was defined as growth of the same microorganismin ≥2 tissue or synovial fluid culture, visible purulence, sinustract or acute inflammation on tissue histopathology. Outcome analysiswas performed at outpatient visits, followed by contacting patients,their relatives and/or treating physicians afterwards.Results: During the study period, 117 patients with THA were identified.We exclude 2 patients due to missing data. The median age was69 years (range, 33-102 years); 42% were women. THA was mainlyperformed for osteoarthritis (n = 84), followed by trauma (n = 22),necrosis (n = 4), dysplasia (n = 2), rheumatoid arthritis (n = 1), osteosarcoma(n = 1) and tuberculosis (n = 1). 28 infections occurred early(≤3 months), 25 delayed (3-24 months) and 63 late (≥24 months aftersurgery). Infected THA were treated with (i) two-stage exchange in59 patients (51%, cure rate: 93%), (ii) one-stage exchange in 5 (4.3%,cure rate: 100%), (iii) debridement with change of mobile parts in18 (17%, cure rate: 83%), (iv) debridement without change of mobileparts in 17 (14%, cure rate: 53% ), (v) Girdlestone in 13 (11%, curerate: 100%), and (vi) two-stage exchange followed by removal in 3(2.6%). Patients were followed for a mean of 3.9 years (range, 0.1 to 9years), 7 patients died unrelated to the infected THA. 15 patients (13%)needed additional operations, 1 for mechanical reasons (dislocationof spacer) and 14 for persistent infection: 11 treated with debridementand retention (8 without change and 3 with change of mobile parts)and 3 with two-stage exchange. The mean number of surgery was 2.2(range, 1 to 5). The infection was finally eradicated in all patients, butthe functional outcome remained unsatisfactory in 20% (persistentpain or impaired mobility due to spacer or Girdlestone situation).Conclusions: Non-respect of current treatment concept leads totreatment failure with subsequent operations. Precise analysis of eachtreatment failures can be used for improving the treatment algorithmleading to better results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A numerical study of Brownian motion of noninteracting particles in random potentials is presented. The dynamics are modeled by Langevin equations in the high friction limit. The random potentials are Gaussian distributed and short ranged. The simulations are performed in one and two dimensions. Different dynamical regimes are found and explained. Effective subdiffusive exponents are obtained and commented on.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective¦Joint hypermobility (JH) and Joint Hypermobility Syndrome (JHS) are often underdiagnosed¦and were never specifically assessed in a selected population of chronic low back pain¦(LBP). This study aimed to assess JH and JHS among a population with chronic LBP using the¦Beighton and the Brigthon criteria.¦Methods¦We conducted a retrospective cross-sectional study based on a prospective data base¦among 143 patients with non-specific chronic LBP. Patients were seen by the same rheumatologist,¦who looked for JH and JHS and took their medical history. Data were analysed using logistic¦regression.¦Results¦We found a JH prevalence of 33,3% (CI 95% 22.0-44.6) among women and 21,4% (11.7-¦31.2) among men, and for JHS, of 37,9% (26.0-49.8) among women and 30,9% (19.7-42.0) among¦men. JH was less frequent among people older than fifty (P < 0.02). JHS was more prevalent among¦Swiss individuals (P < 0.01) and among individuals having a non-manual job (P<0.03) compared to¦there opposites. Patients having an important limitation for daily living activities were four times¦more likely to have JHS. Degenerative spinal disorders were negatively associated with JH (OR¦0.31 (0.13-0.73) and JHS (OR 0.31 (0.14-0.68).¦Conclusion¦A high prevalence of joint hypermobility was found in our population. JHS should be¦part of differential diagnosis in individuals with chronic non-specific LBP.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Whole pelvis intensity modulated radiotherapy (IMRT) is increasingly being used to treat cervical cancer aiming to reduce side effects. Encouraged by this, some groups have proposed the use of simultaneous integrated boost (SIB) to target the tumor, either to get a higher tumoricidal effect or to replace brachytherapy. Nevertheless, physiological organ movement and rapid tumor regression throughout treatment might substantially reduce any benefit of this approach. PURPOSE: To evaluate the clinical target volume - simultaneous integrated boost (CTV-SIB) regression and motion during chemo-radiotherapy (CRT) for cervical cancer, and to monitor treatment progress dosimetrically and volumetrically to ensure treatment goals are met. METHODS AND MATERIALS: Ten patients treated with standard doses of CRT and brachytherapy were retrospectively re-planned using a helical Tomotherapy - SIB technique for the hypothetical scenario of this feasibility study. Target and organs at risk (OAR) were contoured on deformable fused planning-computed tomography and megavoltage computed tomography images. The CTV-SIB volume regression was determined. The center of mass (CM) was used to evaluate the degree of motion. The Dice's similarity coefficient (DSC) was used to assess the spatial overlap of CTV-SIBs between scans. A cumulative dose-volume histogram modeled estimated delivered doses. RESULTS: The CTV-SIB relative reduction was between 31 and 70%. The mean maximum CM change was 12.5, 9, and 3 mm in the superior-inferior, antero-posterior, and right-left dimensions, respectively. The CTV-SIB-DSC approached 1 in the first week of treatment, indicating almost perfect overlap. CTV-SIB-DSC regressed linearly during therapy, and by the end of treatment was 0.5, indicating 50% discordance. Two patients received less than 95% of the prescribed dose. Much higher doses to the OAR were observed. A multiple regression analysis showed a significant interaction between CTV-SIB reduction and OAR dose increase. CONCLUSIONS: The CTV-SIB had important regression and motion during CRT, receiving lower therapeutic doses than expected. The OAR had unpredictable shifts and received higher doses. The use of SIB without frequent adaptation of the treatment plan exposes cervical cancer patients to an unpredictable risk of under-dosing the target and/or overdosing adjacent critical structures. In that scenario, brachytherapy continues to be the gold standard approach.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We propose a method to obtain a single centered correlation with use of a joint transform correlator. We analyze the required setup to carry out the whole process optically, and we also present experimental results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

It is possible to improve the fringe binarization method of joint transform correlation by choosing a suitable threshold level.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In multiobject pattern recognition the height of the correlation peaks should be controlled when the power spectrum of ajoint transform correlator is binarized. In this paper a method to predetermine the value of detection peaks is demonstrated. The technique is based on a frequency-variant threshold in order to remove the intraclass terms and on a suitable factor to normalize the binary joint power spectrum. Digital simulations and experimental hybrid implementation of this method were carried out.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

RATIONALE AND OBJECTIVES: The purpose of this study was the investigation of the impact of real-time adaptive motion correction on image quality in navigator-gated, free-breathing, double-oblique three-dimensional (3D) submillimeter right coronary magnetic resonance angiography (MRA). MATERIALS AND METHODS: Free-breathing 3D right coronary MRA with real-time navigator technology was performed in 10 healthy adult subjects with an in-plane spatial resolution of 700 x 700 microm. Identical double-oblique coronary MR-angiograms were performed with navigator gating alone and combined navigator gating and real-time adaptive motion correction. Quantitative objective parameters of contrast-to-noise ratio (CNR) and vessel sharpness and subjective image quality scores were compared. RESULTS: Superior vessel sharpness, increased CNR, and superior image quality scores were found with combined navigator gating and real-time adaptive motion correction (vs. navigator gating alone; P < 0.01 for all comparisons). CONCLUSION: Real-time adaptive motion correction objectively and subjectively improves image quality in 3D navigator-gated free-breathing double-oblique submillimeter right coronary MRA.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of different kinds of nonlinear filtering in a joint transform correlator are studied and compared. The study is divided into two parts, one corresponding to object space and the second to the Fourier domain of the joint power spectrum. In the first part, phase and inverse filters are computed; their inverse Fourier transforms are also computed, thereby becoming the reference in the object space. In the Fourier space, the binarization of the power spectrum is realized and compared with a new procedure for removing the spatial envelope. All cases are simulated and experimentally implemented by a compact joint transform correlator.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report the study of the influence of optical aberrations in a joint-transform correlator: The wave aberration of the optical system is computed from data obtained by ray tracing. Three situations are explored: We consider the aberration only in the first diffraction stage (generation of power spectrum), then only in the second (transformation of the power spectrum into correlation), and finally in both stages simultaneously. The results show that the quality of the correlation is determined mostly by the aberrations of the first diffraction stage and that we can optimize the setup by moving the cameras along the optical axis to a suitable position. The good agreement between the predicted data and the experimental results shows that the method explains well the behavior of optical diffraction systems when aberrations are taken into account.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study reviewed the subjective, clinical and radiological outcome of 71 patients (84 feet) treated by scarf osteotomy for hallux valgus deformity at our institution from 1995 to 1998 with an average follow-up time of 22 months (range, 17 to 48 months). At the time of follow-up, 39% of the patients were very satisfied, 50% were satisfied and 11% were not satisfied. The mean AOFAS score raised significantly from 43 points (14-68) preoperatively to 82 points (39 to 100) at follow-up (p &lt; 0.001). The radiological angles including M1-M2, M1-P1, M1-M5 and DMAA improved significantly (p &lt; 0.001). Among the 16 complications recorded, seven (8%) were minor and nine (11%) required an additional procedure. The scarf osteotomy of the first metatarsal coupled with a lateral soft-tissue release and, in three-quarters of our cases, with a basal closing wedge varisation osteotomy of the first phalanx, resulted in overall high satisfaction rate as well as significant clinical and radiological improvements in our series. Nevertheless, the range of motion of the first MP joint remained low: 30 degrees to 74 degrees in 52 patients (62%) and &lt;30 degrees in four patients (5%). Furthermore, the mobility of the first ray as well as the consequences of the procedure in the sagittal plane need to be assessed more accurately, and this may be achieved by incorporating measurement of the plantar pressures in the forefoot area into the global rating system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To compare the performance Glaucoma Quality of Life-15 (GQL-15) Questionnaire, intraocular pressure measurement (IOP Goldmann tonometry) and a measure of visual field loss using Moorfields Motion Displacement Test (MDT) in detecting glaucomatous eyes from a self referred population. Methods: The GQL-15 has been suggested to correlate with visual disability and psychophysical measures of visual function in glaucoma patients. The Moorfields MDT is a multi location perimetry test with 32 white line stimuli presented on a grey background on a standard laptop computer. Each stimulus is displaced between computer frames to give the illusion of "apparent motion". Participants (N=312, 90% older than 45 years; 20.5% family history of glaucoma) self referred to an advertised World Glaucoma Day (March 2009) Jules Gonin Eye Hospital, Lausanne Switzerland. Participants underwent a clinical exam (IOP, slit lamp, angle and disc examination by a general ophthalmologist), 90% completed a GQL-15 questionnaire and over 50% completed a MDT test in both eyes. Those who were classified as abnormal on one or more of the following (IOP >21 mmHg/ GQL-15 score >20/ MDT score >2/ clinical exam) underwent a follow up clinical examination by a glaucoma specialist including imaging and threshold perimetry. After the second examination subjects were classified as "healthy"(H), "glaucoma suspect" (GS) (ocular hypertension and/or suspicious disc, angle closure with SD) or "glaucomatous" (G). Results: One hundred and ten subjects completed all 4 initial examinations; of these 69 were referred to complete the 2nd examination and were classified as; 8 G, 24 GS, and 37 H. MDT detected 7/8 G, and 7/24 GS, with false referral rate of 3.8%. IOP detected 2/8 G and 8/24 GS, with false referral rate of 8.9%. GQL-15 detected 4/8 G, 16/24 GS with a false referral rate of 42%. Conclusions: In this sample of participants attending a self referral glaucoma detection event, the MDT performed significantly better than the GQL-15 and IOP in discriminating glaucomatous patients from healthy subjects. Further studies are required to assess the potential of the MDT as a glaucoma screening tool.