1000 resultados para ion interferometry


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Part I. Novel composite polyelectrolyte materials were developed that exhibit desirable charge propagation and ion-retention properties. The morphology of electrode coatings cast from these materials was shown to be more important for its electrochemical behavior than its chemical composition.

Part II. The Wilhelmy plate technique for measuring dynamic surface tension was extended to electrified liquid-liquid interphases. The dynamical response of the aqueous NaF-mercury electrified interphase was examined by concomitant measurement of surface tension, current, and applied electrostatic potential. Observations of the surface tension response to linear sweep voltammetry and to step function perturbations in the applied electrostatic potential (e.g., chronotensiometry) provided strong evidence that relaxation processes proceed for time-periods that are at least an order of magnitude longer than the time periods necessary to establish diffusion equilibrium. The dynamical response of the surface tension is analyzed within the context of non-equilibrium thermodynamics and a kinetic model that requires three simultaneous first order processes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Several different methods have been employed in the study of voltage-gated ion channels. Electrophysiological studies on excitable cells in vertebrates and molluscs have shown that many different voltage-gated potassium (K+) channels and sodium channels may coexist in the same organism. Parallel genetic studies in Drosophila have identified mutations in several genes that alter the properties of specific subsets of physiologically identified ion channels. Chapter 2 describes molecular studies that identify two Drosophila homologs of vertebrate sodium-channel genes. Mutations in one of these Drosophila sodium-channel genes are shown to be responsible for the temperature-dependent paralysis of a behavioural mutant parats. Evolutionary arguments, based on the partial sequences of the two Drosophila genes, suggest that subfamilies of voltage-gated sodium channels in vertebrates remain to be identified.

In Drosophila, diverse voltage-gated K+ channels arise from alternatively spliced mRNAs generated at the Shaker locus. Chapter 3 and the Appendices describe the isolation and characterization of several human K+-channel genes, similar in sequence to Shaker. Each of these human genes has a highly conserved homolog in rodents; thus, this K+-channel gene family probably diversified prior to the mammalian radiation. Functional K+ channels encoded by these genes have been expressed in Xenopus oocytes and their properties have been analyzed by electrophysiological methods. These studies demonstrate that both transient and noninactivating voltage-gated K+ channels may be encoded by mammalian genes closely related to Shaker. In addition, results presented in Appendix 3 clearly demonstrate that independent gene products from two K+-channel genes may efficiently co-assemble into heterooligomeric K+ channels with properties distinct from either homomultimeric channel. This finding suggests yet another molecular mechanism for the generation of K+-channel diversity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The quality of a thermoelectric material is judged by the size of its temperature de- pendent thermoeletric-figure-of-merit (zT ). Superionic materials, particularly Zn4Sb3 and Cu2Se, are of current interest for the high zT and low thermal conductivity of their disordered, superionic phase. In this work it is reported that the super-ionic materials Ag2Se, Cu2Se and Cu1.97Ag0.03Se show enhanced zT in their ordered, normal ion-conducting phases. The zT of Ag2Se is increased by 30% in its ordered phase as compared to its disordered phase, as measured just below and above its first order phase transition. The zT ’s of Cu2Se and Cu1.97Ag0.03Se both increase by more than 100% over a 30 K temperatures range just below their super-ionic phase transitions. The peak zT of Cu2Se is 0.7 at 406 K and of Cu1.97Ag0.03Se is 1.0 at 400 K. In all three materials these enhancements are due to anomalous increases in their Seebeck coefficients, beyond that predicted by carrier concentration measurements and band structure modeling. As the Seebeck coefficient is the entropy transported per carrier, this suggests that there is an additional quantity of entropy co-transported with charge carriers. Such co-transport has been previously observed via co-transport of vibrational entropy in bipolaron conductors and spin-state entropy in NaxCo2O4. The correlation of the temperature profile of the increases in each material with the nature of their phase transitions indicates that the entropy is associated with the thermodynamcis of ion-ordering. This suggests a new mechanism by which high thermoelectric performance may be understood and engineered.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We propose a surface planar ion chip which forms a linear radio frequency Paul ion trap. The electrodes reside in the two planes of a chip, and the trap axis is located above the chip surface. Its electric field and potential distribution are similar to the standard linear radio frequency Paul ion trap. This ion trap geometry may be greatly meaningful for quantum information processing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We investigate a planar ion chip design with a two-dimensional array of linear ion traps for the scalable quantum information processor. The segmented electrodes reside in a single plane on a substrate and a grounded metal plate, a combination of appropriate rf and DC potentials are applied to them for stable ion confinement, and the trap axes are located above the surface at a distance controlled by the electrodes' lateral extent and the substrate's height as discussed. The potential distributions are calculated using static electric field qualitatively. This architecture is conceptually simple and many current microfabrication techniques are feasible for the basic structure. It may provide a promising route for scalable quantum computers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The disolvated proton, H(OH2)2+ is employed as a chemical reagent in low pressure (˂ 10-5 torr) investigations by ion cyclotron resonance spectroscopy. Since termolecular reactions are absent at low pressure, disolvated protons are not generally observed. However H(OH2)2+ is produced in a sequence of bimolecular reactions in mixtures containing H2O and one of a small number of organohalide precursors. Then a series of hydrated Lewis bases is produced by H3O+ transfer from H(OH2)2+. In Chapter II, the relative stability of hydrated bases containing heteroatoms of both first and second row elements is determined from the preferred direction of H3O+ transfer between BH(OH2)+ complexes. S and P containing bases are shown to bind H3O+ more weakly than O and N bases with comparable proton affinities. A simple model of hydrogen bonding is proposed to account for these observations.

H+ transfer from H(OH2)2+ to several Lewis bases also occurs at low pressure. In Chapter III the relative importance of H3O+ transfer and H+ transfer from H(OH2)2+ to a series of bases is observed to be a function of base strength. Beginning with CH3COOH, the weakest base for which H+ transfer is observed, the importance of H+ transfer increases with increasing proton affinity of the acceptor base. The nature of neutral products formed from H(OH2)2+ by loss of H+ is also considered.

Chapters IV and V deal with thermochemistry of small fluorocarbons determined by photoionization mass spectrometry. The enthalpy of formation of CF2 is considered in Chapter IV. Photoionization of perfluoropropylene, perfluorocyclopropane, and trifluoromethyl benzene yield onsets for ions formed by loss of a CF2 neutral fragment. Earlier determinations of ΔH°f298 (CF2) are reinterpreted using updated thermochemical values and compared with results of this study. The heat of formation of neutral perfluorocyclopropane is also derived. Finally, the energetics of interconversion of perfluoropropylene and perfluorocyclopropane are considered for both the neutrals and their molecular ions.

In Chapter V the heats of formation of CF3+ and CF3I+are derived from photoionization of CF3I. These are considered with respect to ion-molecule reactions observed in CF3I monitored by the techniques of ion cyclotron resonance spectroscopy. Results obtained in previous experiments are also compared.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We propose a technique for dynamic full-range Fourier-domain optical coherence tomography by using sinusoidal phase-modulating interferometry, where both the full-range structural information and depth-resolved dynamic information are obtained. A novel frequency-domain filtering algorithm is proposed to reconstruct a time-dependent complex spectral interferogram from the sinusoidally phase-modulated interferogram detected with a high-rate CCD camera. By taking the amplitude and phase of the inverse Fourier transform of the complex spectral interferogram, a time-dependent full-range cross-sectional image and depth-resolved displacement are obtained. Displacement of a sinusoidally vibrating glass cover slip behind a fixed glass cover slip is measured with subwavelength sensitivity to demonstrate the depth-resolved dynamic imaging capability of our system. (c) 2007 Society of Photo-Optical Instrumentation Engineers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Spurious reflection is one of the troublesome problems in phase-shifting interferometry. This paper deals with the problem on the basis of a two-run-times-two-frame phase-shift algorithm, in which the phase shifts are shared out between the reference beam and the object beam. The effect of spurious reflection on phase measurement is investigated; two simple methods for removal of the effect are presented and each needs only six interferograms. Two other solutions to the spurious reflection problem are also reviewed. The simulation results obtained using these four solutions are compared. The influence of a mix of phase-shifter miscalibration and spurious reflection on phase measurement is also discussed.