917 resultados para high speed camera


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Advances in spinal cord injury (SCI) research are dependent on quality animal models, which in turn rely on sensitive outcome measures able to detect functional differences in animals following injury. To date, most measurements of dysfunction following SCI rely either on the subjective rating of observers or the slow throughput of manual gait assessment. The present study compares the gait of normal and contusion-injured mice using the TreadScan system. TreadScan utilizes a transparent treadmill belt and a high-speed camera to capture the footprints of animals and automatically analyze gait characteristics. Adult female C57Bl/6 mice were introduced to the treadmill prior to receiving either a standardized mild, moderate, or sham contusion spinal cord injury. TreadScan gait analyses were performed weekly for 10 weeks and compared with scores on the Basso Mouse Scale (BMS). Results indicate that this software successfully differentiates sham animals from injured animals on a number of gait characteristics, including hindlimb swing time, stride length, toe spread, and track width. Differences were found between mild and moderate contusion injuries, indicating a high degree of sensitivity within the system. Rear track width, a measure of the animal's hindlimb base of support, correlated strongly both with spared white matter percentage and with terminal BMS. TreadScan allows for an objective and rapid behavioral assessment of locomotor function following mild-moderate contusive SCI, where the majority of mice still exhibit hindlimb weight support and plantar paw placement during stepping.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In modern medico-legal literature, only a small number of publications deal with fatal injuries from black powder guns. Most of them focus on the morphological features such as intense soot soiling, blast tattooing and burn effects in close-range shots or describe the wound ballistics of spherical lead bullets. Another kind of "unusual" and potentially lethal weapons are handguns destined for firing only blank cartridges such as starter and alarm pistols. The dangerousness of these guns is restricted to very close and contact range shots and results from the gas jet produced by the deflagration of the propellant. The present paper reports on a suicide committed with a muzzle-loading percussion pistol cal. 45. An unusually large stellate entrance wound was located in the precordial region, accompanied by an imprint mark from the ramrod and a faint greenish discoloration (apparently due to the formation of sulfhemoglobin). Autopsy revealed an oversized powder cavity, multiple fractures of the anterior thoracic wall as well as ruptures of the heart, the aorta, the left hepatic lobe and the diaphragm. In total, the zone of mechanical destruction had a diameter of approx. 15 cm. As there was no exit wound and no bullet lodged in the body, the injury was caused exclusively by the inrushing combustion gases of the propellant (black powder) comparable with the gas jet of a blank cartridge gun. In contact shots to ballistic gelatine using the suicide's pistol loaded with black powder but no projectile, the formation of a nearly spherical cavity could be demonstrated by means of a high-speed camera. The extent of the temporary cavity after firing with 5 g of black powder roughly corresponded to the zone of destruction found in the suicide's body.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Numerous designs of bioprosthetic valves exist. The sutureless surgical valve is a newer design concept which combines elements of the transcatheter valve technology with surgical valves. This design aims at shorter and easier implantation. It was the aim of this study to perform hemodynamic and kinematic measurements for this type of valves to serve as a baseline for following studies which investigate the effect of the aortic root on the valve performance. To this end, the Edwards Intuity aortic valve was investigated in a new in vitro flow loop mimicking the left heart. The valve was implanted in a transparent, compliant aortic root model, and the valve kinematics was investigated using a high speed camera together with synchronized hemodynamic measurements of pressures and flows. The valve closure was asynchronous (one by one leaflet), and the valve started to close before the deceleration of the fluid. The aortic root model showed a dilation of the sinuses which was different to the ascending aorta, and the annulus was found to move towards the left ventricle during diastole and towards the aorta during systole.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

GRC is a cementitious composite material made up of a cement mortar matrix and chopped glass fibers. Due to its outstanding mechanical properties, GRC has been widely used to produce cladding panels and some civil engineering elements. Impact failure of cladding panels made of GRC may occur during production if some tool falls onto the panel, due to stone or other objects impacting at low velocities or caused by debris projected after a blast. Impact failure of a front panel of a building may have not only an important economic value but also human lives may be at risk if broken pieces of the panel fall from the building to the pavement. Therefore, knowing GRC impact strength is necessary to prevent economic costs and putting human lives at risk. One-stage light gas gun is an impact test machine capable of testing different materials subjected to impact loads. An experimental program was carried out, testing GRC samples of five different formulations, commonly used in building industry. Steel spheres were shot at different velocities on square GRC samples. The residual velocity of the projectiles was obtained both using a high speed camera with multiframe exposure and measuring the projectile’s penetration depth in molding clay blocks. Tests were performed on young and artificially aged GRC samples to compare GRC’s behavior when subjected to high strain rates. Numerical simulations using a hydrocode were made to analyze which parameters are most important during an impact event. GRC impact strength was obtained from test results. Also, GRC’s embrittlement, caused by GRC aging, has no influence on GRC impact behavior due to the small size of the projectile. Also, glass fibers used in GRC production only maintain GRC panels’ integrity but have no influence on GRC’s impact strength. Numerical models have reproduced accurately impact tests.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aunque se han logrado importantes avances en estudios de laboratorio con diseños experimentales poco representativos (e.g., Farrow y Reid, 2012; Nieminen, Piirainen, Salmi, y Linnamo, 2013), a día de hoy, todavía se desconoce a cabalidad cómo los jugadores de tenis de diferente nivel de pericia calibran o ajustan sus movimientos a las demandas espacio-temporales presentes en la tarea de resto de un primer servicio. ! Escasos trabajos se han llevado a cabo in situ y a la mayoría se les puede cuestionar algún aspecto de la metodología empleada. Así pues, en varios estudios la frecuencia de grabación ha sido limitada (e.g., a 50 Hz en Jackson y Gudgeon, 2004; Triolet, Benguigui, Le Runigo y Williams, 2013), o la velocidad del saque ha sido visiblemente inferior a la habitual (cf. Carboch, Süss y Kocib, 2014; Williams, Singer y Weigelt, 1998). También, en algunos estudios los participantes experimentados no han sido jugadores de nivel internacional (e.g., Avilés, Ruiz, Sanz y Navia, 2014), y el tamaño muestral ha sido muy pequeño (e.g., Gillet, Leroy, Thouvarecq, Mégrot y Stein, 2010). ! Además, en los diferentes trabajos se han utilizado una diversidad de métodos e instrumentos de medida y los criterios de codificación del inicio de los movimientos y de las respuestas han diferido; como consecuencia el lapso visomotor de respuesta (LVMr) ha sido muy dispar variando considerablemente de 198 a 410 ms. Considerando los inconvenientes señalados anteriormente, el presente estudio tuvo como objetivo determinar un modelo técnico de regulación temporal de los movimientos y de la respuesta del restador, tomando en cuenta el flujo continuo de información proporcionado por el sacador. Para ello, se realizó un análisis cronométrico de los restos de doce jugadores de diferente nivel deportivo (seis internacionales y seis nacionales) que respondieron de forma natural enviando sus devoluciones hacia las dianas. Se grabaron las acciones de los restadores y sacadores con una cámara Casio Exilim Pro Ex-F1 de alta velocidad (300 Hz) y luego se realizó un análisis imagen por imagen cada 3.33 ms. Una vez obtenidos los datos de los vídeos se realizaron análisis con las pruebas de ANOVA de un factor, ANCOVA con la velocidad del saque como covariable, U de Mann-Whitney y Chi-cuadrado de Pearson. En cuanto a la regulación del movimiento hasta el momento del despegue, los jugadores internacionales iniciaron sus acciones antes que los jugadores nacionales lo que podría indicar una mejor preparación al ejecutar los movimientos como reflejo del nivel de pericia. Los jugadores internacionales iniciaron la elevación del pie posterior a -293 ms y los jugadores nacionales a -202 ms. Todas estas acciones se fueron enlazando unas con otras y fue en el momento del impacto del sacador donde los restadores demostraron una remarcable coordinación perceptivo-motriz. Por consiguiente, los jugadores internacionales despegaron e iniciaron el vuelo a tan solo -6.5 ms del impacto y los jugadores nacionales lo hicieron más tarde a +19.5 ms. A lo largo de la secuencia temporal, todo parece indicar que las informaciones que utilizan los restadores interactúan entre sí; información más temprana y menos fiable para anticipar o moverse antes e información más tardía y más fiable para regular la temporalización de las acciones. Los restadores de nivel internacional y nacional anticiparon a nivel espacial en un bajo porcentaje (7.7% vs. 13.6%) y en tiempos similares (-127 vs. -118 ms) sugiriendo que la utilización de variables ópticas tempranas y menos fiables solo se produce en contadas ocasiones. Por otra parte, estos datos se relacionan con una gran precisión en la respuesta ya que tanto los jugadores internacionales como los nacionales demostraron un alto porcentaje de acierto al responder (95.4% vs. 96.7%). Se había señalado que los jugadores internacionales y nacionales se diferenciarían en el tiempo de caída (i.e., aterrizaje) del primer pie del salto preparatorio, sin embargo ese efecto no fue encontrado (128 vs. 135 ms). Tampoco se hallaron diferencias en el porcentaje de caída con el pie contrario a la dirección de la pelota (58% vs. 62%). Donde sí ambos grupos se diferenciaron fue en el tiempo de caída del segundo pie (147 vs. 168 ms). Esta diferencia de 21 ms fue crucial y fue una prueba de la mayor rapidez de los jugadores internacionales; sugiriendo que ésta acción se podría relacionar con el momento del inicio de la respuesta. Aunque los jugadores internacionales hayan demostrado ser más rápidos en relación con sus capacidades funcionales, ambos grupos no se diferenciaron en todas las variables relacionadas con el LVMr. Ellos no utilizaron esos valiosos milisegundos ganados en el instante de la caída del segundo pie para responder más pronto, ya que el LVMr del miembro superior fue el mismo para ambos grupos (179 vs. 174 ms). Es como si hubiesen tenido todo el tiempo del mundo para seguir ajustando sus acciones hasta el propio golpeo. Además, estos tiempos largos sugieren que en la gran mayoría de los restos la información clave que determinó la respuesta fue detectada (extraída) en momentos cercanos al golpeo del sacador y en la primera parte del vuelo de la pelota. Asimismo, se constató que en general el LVMr se ve influenciado por el tipo de información utilizada. De esta manera, cuando se tomaron en cuenta los ensayos en los que hubo anticipación espacial reflejados en el LVMr del cuerpo entero los tiempos disminuyeron (152 vs. 136 ms). Por otra parte, existieron ocasiones (13%) en los que tanto los jugadores internacionales como los nacionales respondieron tarde recibiendo saques directos (208 vs. 195 ms). Es muy posible que en estos casos los jugadores hayan tenido problemas para detectar la información respondiendo fuera de los márgenes temporales de acción lo que mermó su rendimiento. Lo mismo pudo haber ocurrido cuando ambos grupos de jugadores corrigieron el movimiento del miembro superior tras el impacto (17% vs. 10%) lo que aumentó el tiempo en responder al redirigir la respuesta hacia el lado correcto (208 vs. 205 ms). Además, los jugadores internacionales obtuvieron tiempos de movimiento menores que el de los jugadores nacionales (509 vs. 531 ms) lo que se reflejó en un tiempo total de actuación menor (683 vs. 703 ms). Por último, en cuanto al rendimiento del resto, los jugadores internacionales obtuvieron valores superiores a los jugadores nacionales (1.3 vs. 0.9). ABSTRACT Although there have been significant advances in laboratory studies with unrepresentative experimental designs (e.g., Farrow y Reid, 2012; Nieminen, Piirainen, Salmi, y Linnamo, 2013), today it is still unknown to full extent how tennis players of different levels of expertise calibrate or adjust their movements to the spatial-temporal demands present in the return of a first serve. Few studies have been carried out in situ and some aspects of the methodology most of them used can be questioned. Thus, in several studies the recording frequency has been limited (e.g., a 50 Hz en Jackson y Gudgeon, 2004; Triolet, Benguigui, Le Runigo y Williams, 2013), or serve speed was visibly lower than the usual one (cf. Carboch, Süss y Kocib, 2014; Williams, Singer y Weigelt, 1998). Also, in some studies, experienced participants have not played at international level (e.g., Avilés, Ruiz, Sanz y Navia, 2014), and the sample size has been very small (e.g., Gillet, Leroy, Thouvarecq, Mégrot y Stein, 2010). Furthermore, different works have used a variety of methods and measurement instruments and coding criteria of the onset of movements and responses have differed; due to this, visuomotor response delay (LVMr) has been very uneven, varying considerably from 198-410 ms. Considering the drawbacks mentioned above, this study aimed to determine a technical model of temporal regulation of movements and returner’s response, taking into account the continuous flow of information provided by the server. For this, a chronometric analysis of the returns of twelve players (six international and six national) of different sports level, that naturally responded by hitting their returns towards the targets, was performed. Actions of servers and returners were recorded with a Casio Exilim Pro Ex-F1 high speed camera (300 Hz) and then every 3.33 ms analysis was made frame by frame. Once the data of the videos were obtained, analyses were performed using one factor ANOVA test, ANCOVA with the speed of the serve as a covariate, U of Mann- Whitney and Pearson’s Chi-square test. As for the regulation of movement until the moment of serve, international players began their actions before national players, which could indicate that they were better prepared to execute movements reflecting the level of their expertise. International players began raising the rear foot at -293 ms and national players at -202 ms. All these actions were being linked to each other and it was at the moment of impact of the server when the receivers demonstrated a remarkable perceptual-motor coordination. Therefore, international players took off and started their flight just -6.5 ms before the serve and national players did the same somewhat later: +19.5 ms after the serve. Along the timeline, everything seems to indicate that the information used by returners interact with each other; early information which is less reliable to anticipate or move before, and later information more reliable appears to regulate the timing of actions. Returners of international and national levels anticipated at spatial level in a low percentage (7.7% vs. 13.6%) and in similar times (-127 vs. -118 ms) suggesting that the use of early and less reliable optical variables is only produced on rare occasions. Moreover, these data relate to a precise response as both international and national players showed a high percentage of success in responding (95.4% vs. 96.7%). It had been noted that international and national players would differ in the time the fall (i.e., landing) of the first foot of the split-step, however, this effect was not found (128 vs. 135 ms). No differences in the percentage of fall with the opposite foot to the direction of the ball (58% vs. 62%) were found. Where the two groups differed was in the time of the fall of the second foot (147 vs. 168 ms). This difference of 21 ms was crucial and it was a proof of mayor speed of international players; suggesting that this action could be related to the onset time of response. Although international players have proven to be faster in relation to their functional capabilities, both groups did not differ in all variables related to LVMr. They did not use those precious milliseconds earned at the time of the fall of the second foot to respond as soon, since the LVMr of the upper limb was the same for both groups (179 vs. 174 ms). It is as if they had all the time in the world to continue to adjust their actions until the return itself. Furthermore, these long times suggest that in the vast majority of the returns, key information that determined the response was detected (pick-up) in moments close to the hit of the server and in the first part of the ball flight. It was also found that in general the LVMr is influenced by the type of information used. Thus, when taking into account the trials during which there was spatial anticipation, reflected in LVMr of the whole body, the times decreased (152 vs. 136 ms). On the other hand, there were occasions (13%) where both international and national players responded late, thus receiving aces (208 vs. 195 ms). It is quite possible that in these cases the players have had trouble to pick-up information, responding out of temporary margins of action, which affected their performance. The same could have occurred when both groups of players corrected upper limb movement after impact (17% vs. 10%), which increased the time to respond and to redirect the return towards the right side (208 vs. 205 ms). Moreover, international players scored lower movement times than the national players (509 vs. 531 ms), which was reflected in a shorter total response time (683 vs. 703 ms). Finally, as far as the performance of return is concerned, international players scored above the national players values (1.3 vs. 0.9).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Presentación oral SPIE Photonics Europe, Brussels, 16-19 April 2012.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Subpixel techniques are commonly used to increase the spatial resolution in tracking tasks. Object tracking with targets of known shape permits obtaining information about object position and orientation in the three-dimensional space. A proper selection of the target shape allows us to determine its position inside a plane and its angular and azimuthal orientation under certain limits. Our proposal is demonstrated both numerical and experimentally and provides an increase the accuracy of more than one order of magnitude compared to the nominal resolution of the sensor. The experiment has been performed with a high-speed camera, which simultaneously provides high spatial and temporal resolution, so it may be interesting for some applications where this kind of targets can be attached, such as vibration monitoring and structural analysis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We present a targetless motion tracking method for detecting planar movements with subpixel accuracy. This method is based on the computation and tracking of the intersection of two nonparallel straight-line segments in the image of a moving object in a scene. The method is simple and easy to implement because no complex structures have to be detected. It has been tested and validated using a lab experiment consisting of a vibrating object that was recorded with a high-speed camera working at 1000 fps. We managed to track displacements with an accuracy of hundredths of pixel or even of thousandths of pixel in the case of tracking harmonic vibrations. The method is widely applicable because it can be used for distance measuring amplitude and frequency of vibrations with a vision system.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Suurnopeuskameroiden kehitys ja niiden käytön yleistyminen on tuonut teknologian helposti saataville. Suurnopeuskameroita on eri hintaluokissa moniin eri käyttötarkoituksiin. Suurnopeuskameran käyttö tarjoaa tutkimuksen tekemisessä useita hyötyjä. Kuvaaminen itsessään ei yleensä häiritse kuvattavaa prosessia, sekä suurnopeuskameralla saadaan kuvattua erittäin nopeitakin reaktioita ja tapahtumia. Haittoihin lukeutuu tulosten analysoinnin työläys ja tallennustilan optimointi. Kuvattavaa prosessia analysoitaessa täytyy ottaa huomioon, kuinka pitkään täytyy kuvata, kuinka suurella resoluutiolla sekä kuinka monta kuvaa sekunnissa tarvitaan. Tallennustilan optimoinnissa nämä kolme asiaa toimivat parametreina. Suurnopeuskameran käyttöä tutkitaan tekemällä tutkimus jäännöshiilen palamisesta. Työssä tutkitaan muodon ja lämpötilan vaikutusta jäännöshiilen palamiseen. Tulokset saadaan videoista Matlab-sovelluksen avulla. Videot muokataan binääriseen muotoon ja ne analysoidaan kuva kuvalta. Koon kehityksestä piirretään kuvaajat Excelillä. Korkeammissa lämpötiloissa kappaleet paloivat nopeammin. Myös muodon suhteellinen vaikutus palamisnopeuteen näytti tulosten valossa olevan suurempi korkeammissa lämpötiloissa.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The main objective of blasting is to produce optimum fragmentation for downstream processing. Fragmentation is usually considered optimum when the average fragment size is minimum and the fragmentation distribution as uniform as possible. One of the parameters affecting blasting fragmentation is believed to be time delay between holes of the same row. Although one can find a significant number of studies in the literature, which examine the relationship between time delay and fragmentation, their results have been often controversial. The purpose of this work is to increase the level of understanding of how time delay between holes of the same row affects fragmentation. Two series of experiments were conducted for this purpose. The first series involved tests on small scale grout and granite blocks to determine the moment of burden detachment. The instrumentation used for these experiments consisted mainly of strain gauges and piezoelectric sensors. Some experiments were also recorded with a high speed camera. It was concluded that the time of detachment for this specific setup is between 300 and 600 μs. The second series of experiments involved blasting of a 2 meter high granite bench and its purpose was the determination of the hole-to-hole delay that provides optimum fragmentation. The fragmentation results were assessed with image analysis software. Moreover, vibration was measured close to the blast and the experiments were recorded with high speed cameras. The results suggest that fragmentation was optimum when delays between 4 and 6 ms were used for this specific setup. Also, it was found that the moment at which gases first appear to be venting from the face was consistently around 6 ms after detonation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The application of high-speed machine vision for close-loop position control, or visual servoing, of a robot manipulator. It provides a comprehensive coverage of all aspects of the visual servoing problem: robotics, vision, control, technology and implementation issues. While much of the discussion is quite general the experimental work described is based on the use of a high-speed binary vision system with a monocular "eye-in-hand" camera.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Measurement accuracy is critical for biomechanical gait assessment. Very few studies have determined the accuracy of common clinical rearfoot variables between cameras with different collection frequencies. Research question: What is the measurement error for common rearfoot gait parameters when using a standard 30Hz digital camera compared to 100Hz camera? Type of study: Descriptive. Methods: 100 footfalls were recorded from 10 subjects ( 10 footfalls per subject) running on a treadmill at 2.68m/s. A high-speed digital timer, accurate within 1ms served as an external reference. Markers were placed along the vertical axis of the heel counter and the long axis of the shank. 2D coordinates for the four markers were determined from heel strike to heel lift. Variables of interest included time of heel strike (THS), time of heel lift (THL), time to maximum eversion (TMax), and maximum rearfoot eversion angle (EvMax). Results: THS difference was 29.77ms (+/- 8.77), THL difference was 35.64ms (+/- 6.85), and TMax difference was 16.50ms (+/- 2.54). These temporal values represent a difference equal to 11.9%, 14.3%, and 6.6% of the stance phase of running gait, respectively. EvMax difference was 1.02 degrees (+/- 0.46). Conclusions: A 30Hz camera is accurate, compared to a high-frequency camera, in determining TMax and EvMax during a clinical gait analysis. However, relatively large differences, in excess of 12% of the stance phase of gait, for THS and THL variables were measured.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We present a novel X-ray frame camera with variable exposure time that is based on double-gated micro-channel plates (MCP). Two MCPs are connected so that their channels form a Chevron-MCP structure, and four parallel micro-strip lines (MSLs) are deposited on each surface of the Chevron-MCP. The MSLs on opposing surfaces of the Chevron-MCP are oriented normal to each other and subjected to high voltage. The MSLs on the input and output surfaces are fed high voltage pulses to form a gating action. In forming two-dimensional images, modifying the width of the gating pulse serves to set exposure times (ranging from ps to ms) and modifying the delay between each gating pulse serves to set capture times. This prototype provides a new tool for high-speed X-ray imaging, and this paper presents both simulations and experimental results obtained with the camera.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

ULTRACAM is a high-speed three-colour CCD camera designed to provide imaging photometry at high temporal resolutions. The instrument is highly portable and will be used at a number of large telescopes around the world. ULTRACAM was successfully commissioned on the 4.2-m William Herschel Telescope on La Palma on 16 May 2002 over 3 months ahead of schedule and within budget. The instrument was funded by PPARC and designed and built by a consortium involving the Universities of Sheffield Southampton and the UKATC Edinburgh. We present an overview of the design and performance characteristics of ULTRACAM and highlight some of its most recent scientific results.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The Rapid Oscillations in the Solar Atmosphere (ROSA) instrument is a synchronized, six-camera high-cadence solar imaging instrument developed by Queen's University Belfast and recently commissioned at the Dunn Solar Telescope at the National Solar Observatory in Sunspot, New Mexico, USA, as a common-user instrument. Consisting of six 1k x 1k Peltier-cooled frame-transfer CCD cameras with very low noise (0.02 - 15 e/pixel/s), each ROSA camera is capable of full-chip readout speeds in excess of 30 Hz, and up to 200 Hz when the CCD is windowed. ROSA will allow for multi-wavelength studies of the solar atmosphere at a high temporal resolution. We will present the current instrument set-up and parameters, observing modes, and future plans, including a new high QE camera allowing 15 Hz for Halpha. Interested parties should see https://habu.pst.qub.ac.uk/groups/arcresearch/wiki/de502/ROSA.html