939 resultados para generator
Resumo:
Nowadays the used fuel variety in power boilers is widening and new boiler constructions and running models have to be developed. This research and development is done in small pilot plants where more faster analyse about the boiler mass and heat balance is needed to be able to find and do the right decisions already during the test run. The barrier on determining boiler balance during test runs is the long process of chemical analyses of collected input and outputmatter samples. The present work is concentrating on finding a way to determinethe boiler balance without chemical analyses and optimise the test rig to get the best possible accuracy for heat and mass balance of the boiler. The purpose of this work was to create an automatic boiler balance calculation method for 4 MW CFB/BFB pilot boiler of Kvaerner Pulping Oy located in Messukylä in Tampere. The calculation was created in the data management computer of pilot plants automation system. The calculation is made in Microsoft Excel environment, which gives a good base and functions for handling large databases and calculations without any delicate programming. The automation system in pilot plant was reconstructed und updated by Metso Automation Oy during year 2001 and the new system MetsoDNA has good data management properties, which is necessary for big calculations as boiler balance calculation. Two possible methods for calculating boiler balance during test run were found. Either the fuel flow is determined, which is usedto calculate the boiler's mass balance, or the unburned carbon loss is estimated and the mass balance of the boiler is calculated on the basis of boiler's heat balance. Both of the methods have their own weaknesses, so they were constructed parallel in the calculation and the decision of the used method was left to user. User also needs to define the used fuels and some solid mass flowsthat aren't measured automatically by the automation system. With sensitivity analysis was found that the most essential values for accurate boiler balance determination are flue gas oxygen content, the boiler's measured heat output and lower heating value of the fuel. The theoretical part of this work concentrates in the error management of these measurements and analyses and on measurement accuracy and boiler balance calculation in theory. The empirical part of this work concentrates on the creation of the balance calculation for the boiler in issue and on describing the work environment.
Resumo:
3G-radioverkon asetusten hallinnointi suoritetaan säätämällä radioverkkotietokantaan talletettavia parametreja. Hallinnointiohjelmistossa tuhannetradioverkon parametrit näkyvät käyttöliittymäkomponentteina, joita ohjelmiston kehityskaaressa jatkuvasti lisätään, muutetaan ja poistetaan asiakkaan tarpeidenmukaan. Parametrien lisäämisen toteutusprosessi on ohjelmistokehittäjälle työlästä ja mekaanista. Diplomityön tavoitteeksi asetettiin kehittää koodigeneraattori, joka luo kaiken toteutusprosessissa tuotetun koodin automaattisesti niistä määrittelyistä, jotka ovat nykyäänkin saatavilla. Työssä kehitetty generaattori nopeuttaa ohjelmoijan työtä eliminoimalla yhden aikaa vievän ja mekaanisen työvaiheen. Seurauksena saadaan yhtenäisempää ohjelmistokoodia ja säästetään yrityksen ohjelmistotuotannon kuluissa, kun ohjelmoijan taito voidaan keskittää vaativimpiin tehtäviin.
Resumo:
Perinteiset sähkökoneen eristemateriaalit eivät kestä vesihöyryä. Vesihöyryä kestävä eristerakenne on tarpeen, kun tehdään hermeettinen turbogeneraattori, jossa vesihöyry virtaa ilmavälin läpi. Tällainen turbogeneraattori mahdollistaa teholtaan tavallista pienemmän biopolttoainevoimalan rakentamisen kustannustehokkaasti. Työssä tutkittiin erilaisia pyörölankakäämityn pienjännitekoneen eristemateriaaleja. Pienoismallikokein testattiin ne eristemateriaalit, joiden uskottiin kirjallisuustietojen perusteella selviytyvän vesihöyryssä. Myös perinteinen, polyesteriin pohjautuva eristerakenne testattiin. Kokeiden perusteella valittiin turbogeneraattorin staattoriin sopiva eristerakenne.
Resumo:
Ydinvoimaloidenprimaarivesikierron puhdistukseen käytetään ioninvaihtohartsia. Käytönjälkeen ioninvaihtohartsi luokitellaan matalaja keskiaktiivisiin jätteisiin. Plasmakäsittelyllä käytetyn ioninvaihtohartsin tilavuutta voidaan pienentää sekä sen orgaaninen luonne poistaa. Plasmakäsittelyn tarkoituksena on hapettaa orgaaninen aines oksideiksi, jotka poistuvat prosessista savukaasuina. Epäorgaaninen aines, joka sisältää radioaktiivisen aineksen, on tarkoitus hapettaa oksideiksi ja sulfideiksi, jotka voidaan kerätä talteen tuhkana. Tässä diplomityössä käsitellään käytetyn ioninvaihtohartsin käsittelyyn suunnitellun plasmapolttoprosessin kehittämistä ja optimointia. Ioninvaihtohartsin plasmakäsittelyssä syntyvien reaktiotuotteiden selvittäminen suoritettiin tarkastelemalla ainetaseita sekä aihetta käsitteleviä tutkimuksia. Näiden perusteella parannettiin jäähdytystä, suunniteltiin jatkuvatoiminen syöttömenetelmä sekä laadittiin toimintaalueen reunaehdot laitteistolle. Koelaitteistossa 6,5 kW:n rfteho syötetään sovitinpiirin ja kuparisen induktiokelan kautta plasmaan. Plasmakaasuna on käytetty hapenja argonin seoskaasua. Plasmapolttoa on seurattu massaspektrometrilla, optisella emissiospektrometrilla, lämpösekä painemittareilla. Laskennan ja kokeiden pohjalta selvitettiin optimaalinen seossuhde plasmakaasulle, paineen ja tehon noston vaikutus hartsin polttonopeuteen sekä jatkuvatoimisen syöttömenetelmän edut panostoimiseen syöttöön. Rfgeneraattorin teho rajoitti jatkuvatoimisen polttonopeuden 130 g/h ja hetkellisen polttonopeuden 175 g/h. Radioaktiivisten aineiden pidätys oli 93,5 % cesiumin osalta. Tulosten perusteella 4 kg/h ioninvaihtohartsia polttavan laitteiston tehon lähteeksi tarvitaan 65 kW rfgeneraattori. Palamattoman hartsin ja tuhkan kulkeutuminen partikkelisuodattimille sekä reaktiotuotteena syntyvien rikinoksidien käsittely vaatii vielä jatkotutkimusta.
Resumo:
Alahuulten, kärkilistojen, turboputkien ja telapinnoitteiden pinnankarheutta mitataan Rautpohjan tehtaalla nykyään pääosin koskettavalla pinnankarheusprofilometrilla. Profilometrin käyttö on hankalaa ja epäluotettavaa tai käytössä on muita ongelmia. Paperin kuituorientaation mittaamiseen käytetään nykyisin mm. TSO-menetelmää tai repäisymenetelmää. Tämän diplomityön tarkoituksena oli kartoittaa diffraktiiviseen optiseen elementtiin perustuvan kiiltomittalaiteprototyypin mahdollisuuksia karakteroida pinnan ominaisuuksia ja tutkia kiiltomittalaitteen soveltuvuutta tuotannon laadunvarmistuksessa. Alahuuli-, kärkilista-, turboputki-, telapinnoite- ja paperinäytteistä valmistettiinnäytesarjoja, jotka mitattiin nykymenetelmin ja kiiltomittalaitteella. Tulostenkorreloituvuutta tutkittiin ja taloudellista merkitystä arvioitiin investointilaskelmin. Paperin kuituorientaation, paperin pinnan kuituorientaation ja telapinnoitteiden mittaaminen kiiltomittalaitteella osoittautui taloudellisesti erittäin merkittäväksi. Ennen mahdollista kiiltomittalaitteen käyttöönottoa prototyyppiä on kehitettävä, kiillon korreloituvuutta tulee tutkia edelleen ja aiheesta on tehtävä lisätutkimuksia.
Resumo:
Tässä työssä simuloitiin Valkealassa sijaitsevaa Tirvan pienvesivoimalaitosta ja sen vaikutusta sähkönjakeluverkkoon. Pienvesivoimalaitos mallinnettiin PSCAD-ympäristöön verkko- ja voimalaitostietojen perusteella. Sähköverkko kuvattiin malliin koko 110 kV:n siirtävän verkon ja Tirvan pienjänniteverkon väliltä. Mallin avulla tehtiin sarja hajautettua sähköntuotantoa koskevia tarkasteluita. Tarkasteluissa huomattiin voimalaitoksen verkkoonliitynnän aiheuttavan standardien ylärajoilla olevan transienttisen muutoksen voimalaitoksen jännitteisiin. Työssä tehtiin yksityiskohtaisempi jännitehäviöiden mittaus voimalaitoksen pullonkaulana toimivalle pienitehoiselle jakelumuuntajalle. Tuotannon lisäämisen yhteydessä näkyvän yllättävän jännitteen laskun syyt paikannettiin muuntajalla tapahtuviin loistehon siirrosta johtuviin ylimääräisiin jännitehäviöihin. Voimalaitoksella ei ole merkittävää vaikutusta vikatilanteiden virtoihin.
Resumo:
This thesis gives an overview of the validation process for thermal hydraulic system codes and it presents in more detail the assessment and validation of the French code CATHARE for VVER calculations. Three assessment cases are presented: loop seal clearing, core reflooding and flow in a horizontal steam generator. The experience gained during these assessment and validation calculations has been used to analyze the behavior of the horizontal steam generator and the natural circulation in the geometry of the Loviisa nuclear power plant. The cases presented are not exhaustive, but they give a good overview of the work performed by the personnel of Lappeenranta University of Technology (LUT). Large part of the work has been performed in co-operation with the CATHARE-team in Grenoble, France. The design of a Russian type pressurized water reactor, VVER, differs from that of a Western-type PWR. Most of thermal-hydraulic system codes are validated only for the Western-type PWRs. Thus, the codes should be assessed and validated also for VVER design in order to establish any weaknesses in the models. This information is needed before codes can be used for the safety analysis. Theresults of the assessment and validation calculations presented here show that the CATHARE code can be used also for the thermal-hydraulic safety studies for VVER type plants. However, some areas have been indicated which need to be reassessed after further experimental data become available. These areas are mostly connected to the horizontal stem generators, like condensation and phase separation in primary side tubes. The work presented in this thesis covers a large numberof the phenomena included in the CSNI code validation matrices for small and intermediate leaks and for transients. Also some of the phenomena included in the matrix for large break LOCAs are covered. The matrices for code validation for VVER applications should be used when future experimental programs are planned for code validation.
Resumo:
The present study focuses on two effects of the presence of a noncondensable gas on the thermal-hydraulic behavior of thecoolant of the primary circuit of a nuclear reactor in the VVER-440 geometry inabnormal situations. First, steam condensation with the presence of air was studied in the horizontal tubes of the steam generator (SG) of the PACTEL test facility. The French thermal-hydraulic CATHARE code was used to study the heat transfer between the primary and secondary side in conditions derived from preliminary experiments performed by VTT using PACTEL. In natural circulation and single-phase vapor conditions, the injection of a volume of air, equivalent to the totalvolume of the primary side of the SG at the entrance of the hot collector, did not stop the heat transfer from the primary to the secondary side. The calculated results indicate that air is located in the second half-length (from the mid-length of the tubes to the cold collector) in all the tubes of the steam generator The hot collector remained full of steam during the transient. Secondly, the potential release of the nitrogen gas dissolved in the water of the accumulators of the emergency core coolant system of the Loviisa nuclear power plant (NPP) was investigated. The author implemented a model of the dissolution and release ofnitrogen gas in the CATHARE code; the model created by the CATHARE developers. In collaboration with VTT, an analytical experiment was performed with some components of PACTEL to determine, in particular, the value of the release time constant of the nitrogen gas in the depressurization conditions representative of the small and intermediate break transients postulated for the Loviisa NPP. Such transients, with simplified operating procedures, were calculated using the modified CATHARE code for various values of the release time constant used in the dissolution and release model. For the small breaks, nitrogen gas is trapped in thecollectors of the SGs in rather large proportions. There, the levels oscillate until the actuation of the low-pressure injection pumps (LPIS) that refill the primary circuit. In the case of the intermediate breaks, most of the nitrogen gas is expelled at the break and almost no nitrogen gas is trapped in the SGs. In comparison with the cases calculated without taking into account the release of nitrogen gas, the start of the LPIS is delayed by between 1 and 1.75 h. Applicability of the obtained results to the real safety conditions must take into accountthe real operating procedures used in the nuclear power plant.
Resumo:
Työn tarkoituksena oli kehittää mittauselektroniikka puutislepinnoitusprosessin ohjaukseen. Mittauselektroniikalla on tarkoitus mitata pikoampeeriluokan virtoja mittaanturilta, jossa virtaa kuuma, noin 250 ºC asteinen kaasu. Mitta-anturin toiminta perustuu ioniliikkuvuusspektrometriaan. Työssä tutkitaan pikoampeeriluokan virtojen mittaamista sekä mittauskytkennöissä käytetyn virta-jännitemuuntimen ominaisuuksia ja mitoittamista. Työ tarkastelee myös T-kytkennän käyttöä vahvistimen takaisinkytkennässä. Jännitekertojakytkentöjä käsitellään teoreettisesti mitta-anturin biasjännitteiden luomiseksi vähäisellä piirilevypinta-alalla. Työssä suunniteltiin mittauselektroniikan esivahvistinprototyypit sekä mitta-anturin biasjännitekytkentä. Mitta-anturin kuumien olosuhteiden vuoksi on mittauselektroniikka siirrettävä etäämmäksi mitta-anturista. Prototyyppikytkennöillä sekä laboratoriomittauksilla selvitettiin mittauselektroniikan esivahvistimien siirtämiseen liittyviä ongelmia. Biasjännitekytkennän suunnittelussa pyrittiin kytkentä toteuttamaan mahdollisimman vähällä piirilevypinta-alalla. Mittauselektroniikka todettiin laboratoriomittausten perusteella toimivaksi puutislepinnoitusprosessissa suoritettavia koemittauksia varten.
Resumo:
La stimulation cérébrale profonde (SCP) nécessite l'implantation chirurgicale d'un système comprenant électrodes cérébrales et boîtier(s) de stimulation. Les noyaux cérébraux visés par la méthodologie stéréotaxique d'implantation doivent être visualisés au mieux par une imagerie à haute résolution. La procédure chirurgicale d'implantation des électrodes se fait si possible en anesthésie locale pour faire des mesures électro-physiologiques et tester en peropératoire l'effet de la stimulation, afin d'optimiser la position de l'électrode définitive. Dans un deuxième temps, le ou les générateur(s) d'impulsions sont implantés en anesthésie générale. La SCP pour les mouvements anormaux a une très bonne efficacité et un risque de complications graves faible quoique non nul. Les complications liées au matériel sont les plus fréquentes. Deep brain stimulation (DBS) requires the surgical implantation of a system including brain electrodes and impulsion generator(s). The nuclei targeted by the stereotaxic implantation methodology have to be visualized at best by high resolution imaging. The surgical procedure for implanting the electrodes is performed if possible under local anaesthesia to make electro-physiological measurements and to test intra-operatively the effect of the stimulation, in order to optimize the position of the definitive electrode. In a second step, the impulsion generator(s) are implanted under general anaesthesia. DBS for movement disorders has a very good efficacy and a low albeit non-zero risk of serious complications. Complications related to the material are the most common.
Resumo:
Tässä diplomityössä on kehitetty kustannustehokas lämmöntalteenottokattila savukaasun virtaukselle alle 150 kg/s. Kehitettävä kattila on luonnonkiertoinen ja pystyrakenteinen. Valitun kattilatyypin etuja muihin kattilatyyppeihin nähden on tarkasteltu. Erityistä huomiota kattilassa on kiinnitetty vedenkäsittelyn yksinkertaistamiseen. Tämä on saavutettu tulistinratkaisulla, jonka säätötarve on vähäinen. Tuorehöyryn lämpötilan säätöön käytettyjä säätömenetelmiä on tarkasteltu ja eri tulistinratkaisuja käyttämällä saavutettavia tuorehöyrymääriä ja säätötarvetta on tutkittu simulointiohjelmaa hyväksi käyttäen. Tulistinratkaisun lisäksi työssä on tarkasteltu syöttöveden käyttöä ulkoiseen lämmitykseen sekä lämmönsiirrinpakettien tuentaa. Lisäpolton toteutusta sekä syöttövesiventtiilin sijoittamista ja syöttövesipumpun valintaa on myös tarkasteltu. Osana työtä on lisäksi tehty kehitettyä kattilaa varten mitoitusohjelma ja mitoitettu sitä käyttäen esimerkkilaitos.
Resumo:
Kaksifaasivirtauksen kuvaamiseen käytettävät mallit, ja menetelmät kaksifaasivirtauksen painehäviön määrittämiseksi kehittyvät yhä monimutkaisimmiksi. Höyrystinputkissa tapahtuvien painehäviöiden arvioinnin vaatiman laskennan suorittamiseksi tietokoneohjelman kehittäminen on välttämätöntä. Tässä työssä on kehitetty itsenäinen PC-ohjelma painehäviöiden arvioimiseksi pakotetulle konvektiovirtaukselle pystysuorissa höyrykattilan höyrystinputkissa. Veden ja vesihöyryn aineominaisuuksien laskentaan käytetään IAPWS-IF97 –yhtälökokoelmaa sekä muita tarvittavia IAPWS:n suosittelemia yhtälöitä. Höyrystinputkessa kulloinkin vallitsevan virtausmuodon määrittämiseen käytetään sovelluskelpoisia virtausmuotojen välisiä rajoja kuvaavia yhtälöitä. Ohjelmassa käytetään painehäviön määritykseen kirjallisuudessa julkaistuja yhtälöitä, virtausmuodosta riippuen, alijäähtyneelle virtaukselle, kupla-, tulppa- ja rengasvirtaukselle sekä tulistetun höyryn virtaukselle. Ohjelman laskemia painehäviöarvioita verrattiin kirjallisuudesta valittuihin mittaustuloksiin. Laskettujen painehäviöiden virhe vaihteli välillä –19.5 ja +23.9 %. Virheiden itseisarvojen keskiarvo oli 12.8 %.
Resumo:
Työssä mallinnettiin kombivoimalaitoksen lämmöntalteenottokattila Apros-simulointiohjelmalla. Simulointimalli valmistettiin vastaamaan Helsingin Energian Vuosaari B:n voimalaitoksen lämmöntalteenottokattilaa, joka toimii kahdella painetasolla. Kattila on Foster Wheelerin valmistama. Ennen mallinnuksen aloittamista tutustuttiin laitoksen termodynamiikkaan, jolloin saatiin riittävä teoreettinen tieto koko laitoksen toiminnasta. Kattilan reunaehtoina ovat kaasuturbiiniprosessi ja laitoksen höyrykierto. Kaasuturbiini korvattiin laskentayhtälöillä, jotka antavat alkuarvot mm. savukaasun massavirralle ja lämpötilalle ennen kattilaa kaasuturbiinin tehon funktiona. Kattila liitetään höyrykiertoon tuorehöyry- ja syöttövesilinjasta, jolloin reunaehtoina annetaan lämpötilat ja paineet massavirroille. Valmistettua mallia testattiin ylösajo- ja kuormanmuutostilanteessa. Ylösajotilanteessa saatuja laskentatuloksia verrattiin todellisen laitoksen mittaustuloksiin, jolloin varmistuttiin simulointimallin oikeasta fysikaalisesta toiminnasta. Kuormanmuutostilanteissa kaasuturbiinin tehoa muutettiin ja samalla seurattiin kattilan reagointia muutostilanteessa. Kuormanmuutosmittauksessa varmistettiin vielä, että kattila reagoi kuormanmuutokseen oikealla tavalla, eikä muutos aiheuta kattilan toiminnalle haitallista värähtelyä.
Resumo:
Voimalaitoksen sisäisellä optimoinnilla pyritään parantamaan prosessia ja lisäämään voimalaitoskonseptin kilpailukykyä energiamarkkinoilla. Tässä työssä optimoitiin lisäpoltolla varustettua, sähköteholtaan noin 125 MW:n maakaasukompivoimalaitosta. Työ on osa Fortum Engineering Oy:n konseptikehitysohjelmaa. Kaasuturbiinin savukaasun sisältämää happea voidaan hyödyntää lämmöntal-teenottokattilan savukaasukanavaan sijoitetussa lisäpoltossa. Lisäpoltolla saadaan nostettua savukaasun lämpötilaa ja lisättyä tuotetun tuorehöyryn määrää. Työssä tutkittiin lisäpolton kannattavuutta ja sen vaikutusta voimalaitoksen mitoitukseen. Lisäpolton lämpötila valitaan teknisten rajoitusten perusteella, jolloin siitä aiheutuvat investointikustannukset eivät nouse merkittäviksi. Optimointimenetelmä pohjautuu Fortum Oyj:ssä kehitetyllä voimalaitossimulaattori Solvolla laskettujen lämpötaseiden ja asiantuntija-arvioihin perustuvien investointikustannuskaavojen käyttöön. Taloudelliset lähtöarvot on valittu Itä-Euroopan markkinatilanteen mukaisiksi. Kannattavuuslaskelmat perustuvat nykyarvomenetelmään, jossa investointikustannuksille ja sähkön ja kaukolämmön myynnistä saaduille tuotoille lasketaan nykyarvo. Teknisten rajoitusten puitteissa suurimman nykyarvon antava tapaus on aina kunkin tutkittavan prosessisuureen optimitapaus. Tutkittavia prosessisuureita voivat olla esimerkiksi tuorehöyryn tila-arvot. Eräs työn tavoitteista oli selvittää lämmöntalteenottokattilan painetasojen optimaalinen lukumäärä. Lisäpoltto todettiin lämmitysvoimalaitoksella kannattavaksi ratkaisuksi kun nyt optimoitua laitosta verrattiin ilman lisäpolttoa mitoitettuun vastaavanlaiseen laitokseen. Kannattavuuslaskelmille tehtiin herkkyystarkastelut, joiden avulla tutkittiin mitoitetun konseptin herkkyyttä taloudellisten lähtöarvojen muutoksille. Herkkyysanalyysin avulla optimoitua voimalaitoskonseptia voidaan hyödyntää suuremmalla taloudellisten lähtöarvojen vaihteluvälillä.
Resumo:
Diplomityössä kerrotaan sähkökoneiden on-line kunnonvalvontaan käytettävistä mittauksista ja analyyseistä sekä antureista, joilla näitä mittauksia voidaan suorittaa. Työssä pohditaan anturielektroniikan suunnittelua ja rakentamista vaativiin ympäristöolosuhteisiin, joita ovat muun muassa korkea lämpötila, kosteus, paine ja voimakkaat magneettikentät. Testataan analogisen lämpötila-anturin toimivuutta taajuusmuuttajakäytön läheisyydessä. Häiriöpiikkien suodattamista varten tehdään mediaanisuodatusohjelma. Lisäksi työssä suunnitellaan kunnonvalvontapilotit pumppuun sellutehtaalle sekä generaattorikäyttöön vesivoimalaan. Pilotit muodostuvat anturoinnista, anturitason tiedonsiirrosta ja mittaustiedon keruusta. Järjestelmää testataan lievästi sisäkehävaurioisella laakerilla. Työssä kerrotaan myös kunnonvalvontajärjestelmän pilotoinnista sellutehtaalle ja analysoidaan sieltä saatuja tuloksia.