994 resultados para external flow
Resumo:
Magdeburg, Univ., Fak. für Verfahrens- und Systemtechnik, Diss., 2013
Resumo:
Magdeburg, Univ., Fak. für Informatik, Diss., 2013
Resumo:
Magdeburg, Univ., Fak. für Verfahrens- und Systemtechnik, Diss., 2015
Resumo:
Otto-von-Guericke-Universität Magdeburg, Fakultät für Mathematik, Univ., Dissertation, 2015
Resumo:
v.31:no.33(1949)
Resumo:
v.24:no.25(1943)
Resumo:
n.s. no.73(1993)
Resumo:
ABSTRACT The biology and morphology of the immature stages of Heliconius sara apseudes (Hübner, [1813]) are still little known. External features of the egg, larvae and pupa of H. sara apseudes are described and illustrated, based upon light and scanning electron microscopy. Eggs with smooth carina, first instar larva with scaly setae, and body of second to fifth instars covered with scattered pinnacles distinguish H. sara apseudes from other heliconiine species.
Resumo:
An analysis is carried out in a sample of 738 industrial plants of the determining factors in the use of internal promotion of blue-collar workers to middle managers and skilled technicians as against their external recruitment. The use of internal promotion is positively correlated with variables indicative of the efforts made by plants to measure employees' skills, and to a lesser extent, with the level of specificity of investments in human capital made by blue-collar workers. Contrary to what was expected, variables related with the use and efficiency of other incentive systems have no significant influence on the increased or decreased use of internal promotion. These results are initial evidence that internal promotions are used to protect and favour specific investments, especially those made by firms in order to discover their workers' skills.
Resumo:
This paper is about the firm innovation process and the cooperation of the innovative firms with other firms and public institutions. A special attention is paid to the cooperation with universities. We use the Technological Innovation Survey (TIS) from the Instituto Nacional de Estadística (Spain) in order to obtain data for 4,159 innovative firms. Our results show that firm's cooperation activities are closely linked to the characteristics of the industry and the firm as well as to the origin of public funds for R&D activities. Key words: Innovation, universities, Spanish economy. JEL code: O31, I20, L60
Resumo:
This technical background paper describes the methods applied and data sources used in the compilation of the 1980-2003 data set for material flow accounts of the Mexican economy and presents the data set. It is organised in four parts: the first part gives an overview of the Material Flow Accounting (MFA) methodology. The second part presents the main material flows of the Mexican economy including biomass, fossil fuels, metal ores, industrial minerals and, construction minerals. The aim of this part is to explain the procedures and methods followed, the data sources used as well as providing a brief evaluation of the quality and reliability of the information used and the accounts established. Finally, some conclusions will be provided.
Resumo:
In this paper we compare the resource flows of Chile, Ecuador, Mexico and Peru between 1980 and 2000. In this time span, the domestic extraction of materials increased in the four countries, mainly due to the mining sector in Chile and Peru, biomass and oil in Ecuador and construction minerals in Mexico. Imports and exports increased too, due to the increasing integration in the international markets, prompted by the liberalization policies undertaken by the four countries between the late 1970s and the late 1990s. The four countries had a negative physical trade balance for most of the period analyzed, meaning that their exports exceeded their imports in terms of weight. However, the increase of imports reduced the physical deficit in Chile, Mexico and Peru. Ecuador’s physical deficit was the highest and did not decrease in the period analyzed. Also, a diversification of exports away from bulk commodities could be observed in Chile and Mexico, and to a lesser extent in Peru, whereas in Ecuador the export sector remained mainly based on oil and biomass. More research is needed to explore the environmental effects of this phenomenon. Also, the indirect flows associated to the direct physical flows deserve to be subject to further analysis.
Resumo:
White micas in carbonate-rich tectonites and a few other rock types of large thrusts in the Swiss Helvetic fold-and-thrust belt have been analyzed by Ar-40/Ar-39 and Rb/Sr techniques to better constrain the timing of Alpine deformation for this region. Incremental Ar-40/Ar-39 heating experiments of 25 weakly metamorphosed (anchizone to low greenschist) samples yield plateau and staircase spectra. We interpret most of the staircase release spectra result from variable mixtures of syntectonic (neoformed) and detrital micas. The range in dates obtained within individual spectra depends primarily on the duration of mica nucleation and growth, and relative proportions of neoformed and detrital mica. Rb/Sr analyses of 12 samples yield dates of ca. 10-39 Ma (excluding one anomalously young sample). These dates are slightly younger than the Ar-40/Ar-39 total gas dates obtained for the same samples. The Rb/ Sr dates were calculated using initial Sr-87/Sr-86 ratios obtained from the carbonate-dominated host rocks, which are higher than normal Mesozoic carbonate values due to exchange with fluids of higher Sr-87/Sr-86 ratios (and lower O-18/O-16 ratios). Model dates calculated using Sr-87/Sr-86 values typical of Mesozoic marine carbonates more closely approximate the Ar-40/Ar-39 total gas dates for most of the samples. The similarities of Rb/Sr and Ar-40/Ar-39 total gas dates are consistent with limited amounts of detrital mica in the samples. The delta(18)O values range from 24-15%. (VSMOW) for 2-6 mum micas and 27-16parts per thousand for the carbonate host rocks. The carbonate values are significantly lower than their protolith values due to localized fluid-rock interaction and fluid flow along most thrust surfaces. Although most calcite-mica pairs are not in oxygen isotope equilibrium at temperatures of ca. 200-400 degreesC, their isotopic fractionations are indicative of either 1) partial exchange between the minerals and a common external fluid, or 2) growth or isotopic exchange of the mica with the carbonate after the carbonate had isotopically exchanged with an external fluid. The geological significance of these results is not easily or uniquely determined, and exemplifies the difficulties inherent in dating very fine-grained micas of highly deformed tectonites in low-grade metamorphic terranes. Two generalizations can be made regarding the dates obtained from the Helvetic thrusts: 1) samples from the two highest thrusts (Mt. Gond and Sublage) have all of their Ar-40/Ar-39 steps above 20 Ma, and 2) most samples from the deepest Helvetic thrusts have steps (often accounting for more than 80% of Ar-39 release) between 15 and 25 Ma. These dates are consistent with the order of thrusting in the foreland-imbricating system and increase proportions of neoformed to detrital mica in the more metamorphosed hinterland and deeply buried portions of the nappe pile. Individual thrusts accommodated the majority of their displacement during their initial incorporation into the foreland-imbricating system, and some thrusts remained active or were reactivated down to 15 Ma.
Resumo:
The PulseCath iVAC 3L? left ventricular assist device is an option to treat transitory left heart failure or dysfunction post-cardiac surgery. Assisted blood flow should reach up to 3 l/min. In the present in vitro model exact pump flow, depending on various frequencies and afterload was examined. Optimal flow was achieved with inflation/deflation frequencies of about 70-80/min. The maximal flow rate was achieved at about 2.5 l/min with a minimal afterload of 22 mmHg. Handling of the device was easy due to the connection to a standard intra-aortic balloon pump console. With increasing afterload (up to a simulated mean systemic pressure of 66 mmHg) flow rate and cardiac support are in some extent limited.
Resumo:
BACKGROUND AND PURPOSE: Accurate placement of an external ventricular drain (EVD) for the treatment of hydrocephalus is of paramount importance for its functionality and in order to minimize morbidity and complications. The aim of this study was to compare two different drain insertion assistance tools with the traditional free-hand anatomical landmark method, and to measure efficacy, safety and precision. METHODS: Ten cadaver heads were prepared by opening large bone windows centered on Kocher's points on both sides. Nineteen physicians, divided in two groups (trainees and board certified neurosurgeons) performed EVD insertions. The target for the ventricular drain tip was the ipsilateral foramen of Monro. Each participant inserted the external ventricular catheter in three different ways: 1) free-hand by anatomical landmarks, 2) neuronavigation-assisted (NN), and 3) XperCT-guided (XCT). The number of ventricular hits and dangerous trajectories; time to proceed; radiation exposure of patients and physicians; distance of the catheter tip to target and size of deviations projected in the orthogonal plans were measured and compared. RESULTS: Insertion using XCT increased the probability of ventricular puncture from 69.2 to 90.2 % (p = 0.02). Non-assisted placements were significantly less precise (catheter tip to target distance 14.3 ± 7.4 mm versus 9.6 ± 7.2 mm, p = 0.0003). The insertion time to proceed increased from 3.04 ± 2.06 min. to 7.3 ± 3.6 min. (p < 0.001). The X-ray exposure for XCT was 32.23 mSv, but could be reduced to 13.9 mSv if patients were initially imaged in the hybrid-operating suite. No supplementary radiation exposure is needed for NN if patients are imaged according to a navigation protocol initially. CONCLUSION: This ex vivo study demonstrates a significantly improved accuracy and safety using either NN or XCT-assisted methods. Therefore, efforts should be undertaken to implement these new technologies into daily clinical practice. However, the accuracy versus urgency of an EVD placement has to be balanced, as the image-guided insertion technique will implicate a longer preparation time due to a specific image acquisition and trajectory planning.