917 resultados para corneal thickness


Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE:

To explore the potential association between adverse corneal events and the use of topical nonsteroidal antiinflammatory drugs (NSAIDs).

SETTING:

Practice-based reports.

METHODS:

A detailed case-reporting form and request for medical records were sent to all practices reporting cases of corneal or conjunctival pathology in association with the use of topical NSAIDs to the American Society of Cataract and Refractive Surgery. Cases were classified as "mild," "moderate," or "severe" according to predetermined clinical criteria.

RESULTS:

Records of 140 eyes (129 patients) were reviewed; 51 cases (36.4%) were mild, 55 (39.3%) moderate, and 34 (24.3%) severe. An association with a specific topical NSAID was confirmed in 117 cases (81.8%). Most confirmed cases (53.8%) involved generic diclofenac (Falcon). Cases associated with brand diclofenac (Voltaren, CIBA Vision) and ketorolac (Acular, Allergan) were more likely to have ocular comorbidity and to have received significantly higher total doses of NSAIDs. Neither "off-label" use nor use of any specific agent was associated with severe compared to mild or moderate disease. However, patients with more severe adverse events were more likely to have a history of diabetes, previous surgery in the affected eye, and surgery other than cataract. Cases not occurring in the perioperative period had significantly worse outcomes, had significantly more ocular comorbidities, and received nearly 3 times the dose of NSAIDs.

CONCLUSIONS:

While topical NSAIDs as a class may be associated with severe adverse events, such events appeared to require potentiation in the form of high total doses, ocular comorbidities, or both with Acular and Voltaren. Severe adverse events might have been more likely to occur at lower doses and in routine postoperative settings with generic diclofenac.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE:

To compare the outcomes of cataract surgery performed with 3 incision size-dependent phacoemulsification groups (1.8, 2.2, and 3.0 mm).

DESIGN:

Prospective randomized comparative study.

METHODS:

One hundred twenty eyes of 120 patients with age-related cataract (grades 2 to 4) were categorized according to the Lens Opacities Classification System III. Eligible subjects were randomly assigned to 3 surgical groups using coaxial phacoemulsification through 3 clear corneal incision sizes (1.8, 2.2, and 3.0 mm). Different intraoperative and postoperative outcome measures were obtained, with corneal incision size and surgically induced astigmatism as the main clinical outcomes.

RESULTS:

There were no statistically significant differences in most of the intraoperative and postoperative outcome measures among the 3 groups. However, the mean cord length of the clear corneal incision was increased in each group after surgery. The mean maximal clear corneal incision thickness in the 1.8-mm group was significantly greater than for the other groups at 1 month. The mean surgically induced astigmatism in the 1.8- and 2.2-mm groups was significantly less than that in the 3.0-mm group after 1 month, without significant difference between the 1.8- and 2.2-mm groups.

CONCLUSIONS:

With appropriate equipment, smaller incisions may result in less astigmatism, but the particular system used will influence incision stress and wound integrity, and may thus limit the reduction in incision size and astigmatism that is achievable.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE:

This study investigated the heritability of lens thickness (LT) and relative lens thickness (LT/axial length, rLT) measured by Lenstar among Chinese children and adolescents in the Guangzhou Twin Eye study.

METHODS:

Twins aged 8 to 22 years were enrolled from the Guangzhou Twin Registry. A series of LT and axial length (AL) measurements using the Lenstar were taken for each twin. Zygosity was confirmed by genotyping in all same-sex twin pairs. Heritability was assessed by structural variance component genetic modeling, after adjustment for age and sex with the Mx program.

RESULTS:

Seven hundred sixty-eight twin pairs (482 monozygotic [MZ] and 286 dizygotic [DZ] twins) were available for data analysis. The mean (standard deviation) LT and rLT were 3.45 (0.18) mm and 0.142 (0.01), respectively. The intraclass correlation coefficients (ICCs) for LT were 0.90 for the MZ and 0.39 for the DZ twins; and those for rLT were 0.90 for the MZ and 0.40 for the DZ twins, respectively. The best-fitting model yielded 89.5% (95% CI: 87.8%-91.0%) of additive genetic effects and 10.5% (95% CI: 9.0%-12.2%) of unique environmental effects for LT, and 89.3% (95% CI: 89.2%-89.3%) of additive genetic effects and 10.7% (95% CI: 10.7%-11.4%) of unique environmental effects for rLT.

CONCLUSIONS:

This study confirms that the LT in young healthy subjects may be mainly affected by additive genetic factors. High heritability remains even when the data are corrected for the influence of AL with the use of rLT.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Three different lubricating greases and their bleed and base oils were compared in terms of film thickness in a ball-on-disc test rig through optical interferometry. The theoretical values calculated according to Hamrock's equation are in close agreement with the base oil film thickness measurements, which validates the selected experimental methodology. The grease and bleed oil film thickness under fully flooded lubrication conditions presented quite similar behaviour and levels. Therefore, the grease film thickness under full film conditions might be predicted using their bleed oil properties, namely the viscosity and pressure-viscosity coefficient. The base and bleed oil lubricant parameter LP are proportional to the measured film thickness. A relationship between grease and the corresponding bleed oil film thickness was evidenced.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Adhesive bonding is nowadays a serious candidate to replace methods such as fastening or riveting, because of attractive mechanical properties. As a result, adhesives are being increasingly used in industries such as the automotive, aerospace and construction. Thus, it is highly important to predict the strength of bonded joints to assess the feasibility of joining during the fabrication process of components (e.g. due to complex geometries) or for repairing purposes. This work studies the tensile behaviour of adhesive joints between aluminium adherends considering different values of adherend thickness (h) and the double-cantilever beam (DCB) test. The experimental work consists of the definition of the tensile fracture toughness (GIC) for the different joint configurations. A conventional fracture characterization method was used, together with a J-integral approach, that take into account the plasticity effects occurring in the adhesive layer. An optical measurement method is used for the evaluation of crack tip opening and adherends rotation at the crack tip during the test, supported by a Matlab® sub-routine for the automated extraction of these quantities. As output of this work, a comparative evaluation between bonded systems with different values of adherend thickness is carried out and complete fracture data is provided in tension for the subsequent strength prediction of joints with identical conditions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BIGH3 is a secreted protein, part of the extracellular matrix where it interacts with collagen and integrins on the cell surface. BIGH3 can play opposing roles in cancer, acting as either tumor suppressor or promoter, and its mutations lead to different forms of corneal dystrophy. Although many studies have been carried out, little is known about the physiological role of BIGH3. Using the cre-loxP system, we generated a mouse model with disruption of the Bigh3 genomic locus. Bigh3 silencing did not result in any apparent phenotype modifications, the mice remained viable and fertile. We were able to determine the presence of BIGH3 in the retinal pigment epithelium (RPE). In the absence of BIGH3, a transient decrease in the apoptotic process involved in retina maturation was observed, leading to a transient increase in the INL thickness at P15. This phenomenon was accompanied by an increased activity of the pro-survival ERK pathway.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The interior layered deposit (ILD) in Ganges Chasma, Valles Marineris, is a 4.25 km high mound that extends approximately 110 km from west to east. The deposition, deformation, and erosion history of the Ganges ILD records aids in identifying the processes that formed and shaped the Chasma. To interpret structural and geomorphic processes acting on the ILD, multiple layer attitudes and layer thickness transects were conducted on the Ganges ILD. Mineralogical data was analyzed to determine correlations between materials and landforms. Layer thickness measurements indicate that the majority of layers are between 0.5 m and 4 m throughout the ILD. Three major benches dominate the Ganges ILD. Layer thicknesses increase at the ILD benches, suggesting that the benches are formed from the gradual thickening of layers. This indicates that the benches are depositional features draping over basement topography. Layer attitudes indicate overall shallow dips generally confined to a North-South direction that locally appear to follow bench topography. Layering is disrupted on a scale of 40 m to 150 m in 12 separate locations throughout the ILD. In all locations, underlying layering is disturbed by overlying folded layers in a trough-like geometry. These features are interpreted to have formed as submarine channels in a lacustrine setting, subsequently infilled by sediments. Subsequently, the channels were eroded to the present topography, resulting in the thin, curved layering observed. Data cannot conclusively support one ILD formation hypothesis, but does indicate that the Ganges ILD postdates Chasma formation. The presence of water altered minerals, consistently thin layering, and layer orientations provide strong evidence that the ILD formed in a lacustrine setting.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cette thèse porte sur l’étude de l’anatomie de la cornée après 3 techniques de greffe soient, la greffe totale traditionnelle (GTT) et des techniques de greffe lamellaire postérieur (GLP) telles que la greffe lamellaire endothéliale profonde (DLEK) et la greffe endothélium/membrane de Descemet (EDMG) pour le traitement des maladies de l’endothélium, telles que la dystrophie de Fuchs et de la kératopathie de l’aphaque et du pseudophaque. Dans ce contexte, cette thèse contribue également à démontrer l’utilité de la tomographie de cohérence optique (OCT) pour l’étude de l’anatomie des plaies chirurgicales la cornée post transplantation. Au cours de ce travail nous avons étudié l'anatomie de la DLEK, avant et 1, 6, 12 et 24 mois après la chirurgie. Nous avons utilisé le Stratus OCT (Version 3, Carl Zeiss, Meditec Inc.) pour documenter l’anatomie de la plaie. L'acquisition et la manipulation des images du Stratus OCT, instrument qui à été conçu originalement pour l’étude de la rétine et du nerf optique, ont été adaptées pour l'analyse du segment antérieur de l’oeil. Des images cornéennes centrales verticales et horizontales, ainsi que 4 mesures radiaires perpendiculaires à la plaie à 12, 3, 6 et 9 heures ont été obtenues. Les paramètres suivants ont été étudiés: (1) Les espaces (gap) entre les rebords du disque donneur et ceux du receveur, (2) les dénivelés de surface postérieure (step) entre le les rebords du disque donneur et ceux du receveur, (3) la compression tissulaire, (4) le décollement du greffon, 6) les élévations de la surface antérieure de la cornée et 7) la pachymétrie centrale de la cornée. Les mesures d’épaisseur totale de la cornée ont été comparées et corrélées avec celles obtenues avec un pachymètre à ultra-sons. Des mesures d’acuité visuelle, de réfraction manifeste et de topographie ont aussi été acquises afin d’évaluer les résultats fonctionnels. Enfin, nous avons comparé les données de DLEK à celles obtenues de l’EDMG et de la GTT, afin de caractériser les plaies et de cerner les avantages et inconvénients relatifs à chaque technique chirurgicale. Nos résultats anatomiques ont montré des différences importantes entre les trois techniques chirurgicales. Certains des paramètres étudiés, comme le sep et le gap, ont été plus prononcés dans la GTT que dans la DLEK et complètement absents dans l’EDMG. D’autres, comme la compression tissulaire et le décollement du greffon n’ont été observés que dans la DLEK. Ceci laisse entrevoir que la distorsion de la plaie varie proportionnellement à la profondeur de la découpe stromale du receveur, à partir de la face postérieure de la cornée. Moins la découpe s’avance vers la face antérieure (comme dans l’EDMG), moins elle affecte l’intégrité anatomique de la cornée, le pire cas étant la découpe totale comme dans la GTT. Cependant, tous les paramètres d’apposition postérieure sous-optimale et d’élévation de la surface antérieure (ce dernier observé uniquement dans la GTT) finissent par diminuer avec le temps, évoluant à des degrés variables vers un profil topographique plus semblable à celui d’une cornée normale. Ce processus paraît plus long et plus incomplet dans les cas de GTT à cause du type de plaie, de la présence de sutures et de la durée de la cicatrisation. Les valeurs moyennes d’épaisseur centrale se sont normalisées après la chirurgie. De plus, ces valeurs moyennes obtenues par OCT étaient fortement corrélées à celles obtenues par la pachymétrie à ultra-sons et nous n’avons remarqué aucune différence significative entre les valeurs moyennes des deux techniques de mesure. L’OCT s’est avéré un outil utile pour l’étude de l’anatomie microscopique des plaies chirurgicales. Les résultats d’acuité visuelle, de réfraction et de topographie des techniques de GLP ont montré qu’il existe une récupération visuelle rapide et sans changements significatifs de l’astigmatisme, contrairement à la GTT avec et sans suture. La GLP a permis une meilleure conservation de la morphologie de la cornée, et par conséquence des meilleurs résultats fonctionnels que la greffe de pleine épaisseur. Ceci nous permet d’avancer que la GLP pourrait être la technique chirurgicale à adopter comme traitement pour les maladies de l’endothélium cornéen.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background/aims: Scant consideration has been given to the variation in structure of the human amniotic membrane (AM) at source or to the significance such differences might have on its clinical transparency. Therefore, we applied our experience of quantifying corneal transparency to AM. Methods: Following elective caesarean, AM from areas of the fetal sac distal and proximal (ie, adjacent) to the placenta was compared with freeze-dried AM. The transmission of light through the AM samples was quantified spectrophotometrically; also, tissue thickness was measured by light microscopy and refractive index by refractometry. Results: Freeze-dried and freeze-thawed AM samples distal and proximal to the placenta differed significantly in thickness, percentage transmission of visible light and refractive index. The thinnest tissue (freeze-dried AM) had the highest transmission spectra. The thickest tissue (freeze-thawed AM proximal to the placenta) had the highest refractive index. Using the direct summation of fields method to predict transparency from an equivalent thickness of corneal tissue, AM was found to be up to 85% as transparent as human cornea. Conclusion: When preparing AM for ocular surface reconstruction within the visual field, consideration should be given to its original location from within the fetal sac and its method of preservation, as either can influence corneal transparency.