958 resultados para consensus methods
Resumo:
Sequence-structure correlation studies are important in deciphering the relationships between various structural aspects, which may shed light on the protein-folding problem. The first step of this process is the prediction of secondary structure for a protein sequence of unknown three-dimensional structure. To this end, a web server has been created to predict the consensus secondary structure using well known algorithms from the literature. Furthermore, the server allows users to see the occurrence of predicted secondary structural elements in other structure and sequence databases and to visualize predicted helices as a helical wheel plot. The web server is accessible at http://bioserver1.physics.iisc.ernet.in/cssp/.
Resumo:
Background: Haemodialysis nurses form long term relationships with patients in a technologically complex work environment. Previous studies have highlighted that haemodialysis nurses face stressors related to the nature of their work and also their work environments leading to reported high levels of burnout. Using Kanters (1997) Structural Empowerment Theory as a guiding framework, the aim of this study was to explore the factors contributing to satisfaction with the work environment, job satisfaction, job stress and burnout in haemodialysis nurses. Methods: Using a sequential mixed-methods design, the first phase involved an on-line survey comprising demographic and work characteristics, Brisbane Practice Environment Measure (B-PEM), Index of Work Satisfaction(IWS), Nursing Stress Scale (NSS) and the Maslach Burnout Inventory (MBI). The second phase involved conducting eight semi-structured interviews with data thematically analyzed. Results: From the 417 nurses surveyed the majority were female (90.9 %), aged over 41 years of age (74.3 %), and 47.4 % had worked in haemodialysis for more than 10 years. Overall the work environment was perceived positively and there was a moderate level of job satisfaction. However levels of stress and emotional exhaustion (burnout) were high. Two themes, ability to care and feeling successful as a nurse, provided clarity to the level of job satisfaction found in phase 1. While two further themes, patients as quasi-family and intense working teams, explained why working as a haemodialysis nurse was both satisfying and stressful. Conclusions: Nurse managers can use these results to identify issues being experienced by haemodialysis nurses working in the unit they are supervising.
Resumo:
Interaction of tetrathiafulvalene (TTF) and tetracyanoethylene (TCNE) with few-layer graphene samples prepared by the exfoliation of graphite oxide (EG), conversion of nanodiamond (DG) and arc-evaporation of graphite in hydrogen (HG) has been investigated by Raman spectroscopy to understand the role of the graphene surface. The position and full-width at half maximum of the Raman G-band are affected on interaction with TTF and TCNE and the effect is highest with EG and least with HG. The effect of TTF and TCNE on the 2D-band is also maximum with EG. The magnitude of interaction between the donor/acceptor molecules varies in the same order as the surface areas of the graphenes. (C) 2009 Published by Elsevier B. V.
Resumo:
Background and purpose: To prospectively evaluate differences in carotid plaque characteristics in symptomatic and asymptomatic patients using high resolution MRI. Methods: 20 symptomatic and 20 asymptomatic patients, with at least 50% carotid stenosis as determined by Doppler ultrasound, underwent preoperative in vivo multispectral MRI of the carotid arteries. Studies were analysed both qualitatively and quantitatively in a randomised manner by two experienced readers in consensus, blinded to clinical status, and plaques were classified according to the modified American Heart Association (AHA) criteria. Results: After exclusion of poor quality images, 109 MRI sections in 18 symptomatic and 19 asymptomatic patients were available for analysis. There were no significant differences in mean luminal stenosis severity (72.9% vs 67.6%; p = 0.09) or plaque burden (median plaque areas 50 mm2 vs 50 mm 2; p = 0.858) between the symptomatic and asymptomatic groups. However, symptomatic lesions had a higher incidence of ruptured fibrous caps (36.5% vs 8.7%; p = 0.004), haemorrhage or thrombus (46.5% vs 14.0%; p<0.001), large necrotic lipid cores (63.8% vs 28.0%; p = 0.002) and complicated type VI AHA lesions (61.5% vs 28.1%; p = 0.001) compared with asymptomatic lesions. The MRI findings of plaque haemorrhage or thrombus had an odds ratio of 5.25 (95% CI 2.08 to 13.24) while thin or ruptured fibrous cap (as opposed to a thick fibrous cap) had an odds ratio of 7.94 (95% CI 2.93 to 21.51) for prediction of symptomatic clinical status. Conclusions: There are significant differences in plaque characteristics between symptomatic and asymptomatic carotid atheroma and these can be detected in vivo by high resolution MRI.
Resumo:
In analysis of longitudinal data, the variance matrix of the parameter estimates is usually estimated by the 'sandwich' method, in which the variance for each subject is estimated by its residual products. We propose smooth bootstrap methods by perturbing the estimating functions to obtain 'bootstrapped' realizations of the parameter estimates for statistical inference. Our extensive simulation studies indicate that the variance estimators by our proposed methods can not only correct the bias of the sandwich estimator but also improve the confidence interval coverage. We applied the proposed method to a data set from a clinical trial of antibiotics for leprosy.
Resumo:
The feasibility of different modern analytical techniques for the mass spectrometric detection of anabolic androgenic steroids (AAS) in human urine was examined in order to enhance the prevalent analytics and to find reasonable strategies for effective sports drug testing. A comparative study of the sensitivity and specificity between gas chromatography (GC) combined with low (LRMS) and high resolution mass spectrometry (HRMS) in screening of AAS was carried out with four metabolites of methandienone. Measurements were done in selected ion monitoring mode with HRMS using a mass resolution of 5000. With HRMS the detection limits were considerably lower than with LRMS, enabling detection of steroids at low 0.2-0.5 ng/ml levels. However, also with HRMS, the biological background hampered the detection of some steroids. The applicability of liquid-phase microextraction (LPME) was studied with metabolites of fluoxymesterone, 4-chlorodehydromethyltestosterone, stanozolol and danazol. Factors affecting the extraction process were studied and a novel LPME method with in-fiber silylation was developed and validated for GC/MS analysis of the danazol metabolite. The method allowed precise, selective and sensitive analysis of the metabolite and enabled simultaneous filtration, extraction, enrichment and derivatization of the analyte from urine without any other steps in sample preparation. Liquid chromatographic/tandem mass spectrometric (LC/MS/MS) methods utilizing electrospray ionization (ESI), atmospheric pressure chemical ionization (APCI) and atmospheric pressure photoionization (APPI) were developed and applied for detection of oxandrolone and metabolites of stanozolol and 4-chlorodehydromethyltestosterone in urine. All methods exhibited high sensitivity and specificity. ESI showed, however, the best applicability, and a LC/ESI-MS/MS method for routine screening of nine 17-alkyl-substituted AAS was thus developed enabling fast and precise measurement of all analytes with detection limits below 2 ng/ml. The potential of chemometrics to resolve complex GC/MS data was demonstrated with samples prepared for AAS screening. Acquired full scan spectral data (m/z 40-700) were processed by the OSCAR algorithm (Optimization by Stepwise Constraints of Alternating Regression). The deconvolution process was able to dig out from a GC/MS run more than the double number of components as compared with the number of visible chromatographic peaks. Severely overlapping components, as well as components hidden in the chromatographic background could be isolated successfully. All studied techniques proved to be useful analytical tools to improve detection of AAS in urine. Superiority of different procedures is, however, compound-dependent and different techniques complement each other.
Resumo:
Conformational preferences of thiocarbonohydrazide (H2NNHCSNHNH2) in its basic and N,N′-diprotonated forms are examined by calculating the barrier to internal rotation around the C---N bonds, using the theoretical LCAO—MO (ab initio and semiempirical CNDO and EHT) methods. The calculated and experimental results are compared with each other and also with values for N,N′-dimethylthiourea which is isoelectronic with thiocarbonohydrazide. The suitability of these methods for studying rotational isomerism seems suspect when lone pair interactions are present.
Resumo:
One difficulty in summarising biological survivorship data is that the hazard rates are often neither constant nor increasing with time or decreasing with time in the entire life span. The promising Weibull model does not work here. The paper demonstrates how bath tub shaped quadratic models may be used in such a case. Further, sometimes due to a paucity of data actual lifetimes are not as certainable. It is shown how a concept from queuing theory namely first in first out (FIFO) can be profitably used here. Another nonstandard situation considered is one in which lifespan of the individual entity is too long compared to duration of the experiment. This situation is dealt with, by using ancilliary information. In each case the methodology is illustrated with numerical examples.
Resumo:
The Macroscopic Fundamental Diagram (MFD) relates space-mean density and flow. Since the MFD represents the area-wide network traffic performance, studies on perimeter control strategies and network-wide traffic state estimation utilising the MFD concept have been reported. Most previous works have utilised data from fixed sensors, such as inductive loops, to estimate the MFD, which can cause biased estimation in urban networks due to queue spillovers at intersections. To overcome the limitation, recent literature reports the use of trajectory data obtained from probe vehicles. However, these studies have been conducted using simulated datasets; limited works have discussed the limitations of real datasets and their impact on the variable estimation. This study compares two methods for estimating traffic state variables of signalised arterial sections: a method based on cumulative vehicle counts (CUPRITE), and one based on vehicles’ trajectory from taxi Global Positioning System (GPS) log. The comparisons reveal some characteristics of taxi trajectory data available in Brisbane, Australia. The current trajectory data have limitations in quantity (i.e., the penetration rate), due to which the traffic state variables tend to be underestimated. Nevertheless, the trajectory-based method successfully captures the features of traffic states, which suggests that the trajectories from taxis can be a good estimator for the network-wide traffic states.
Resumo:
One of the major impediments for the use of UAVs in civilian environment is the capability to replicate some of the functionality of safe manned aircraft operations. One critical aspect is emergency landing. Once the possible landing sites have been rated, a decision on the most suitable choice to land is required. This is a multi-criteria decision making (MCDM) problem which needs to take into account various factors in its selection of landing site. This report summarises relevant literature in MCDM in the context of emergency forced landing and proposes and compares two algorithms and methods for this task.
Resumo:
This thesis explores the feasibility of donor-receiver concept for joint replacement where cartilage-bone tissues can be taken from either human or other mammals and prepared scientifically for repairing focal joint defects in knees, hips and shoulders. The manufactured construct is immunologically inert and is capable of acting as a scaffold for engineering new cartilage-bone laminates when placed in the joint. Innovative manufacturing procedures and assessment techniques were developed for appraising this tissue-based scaffold. This research has demonstrated that tissue replacement technology can be applied in situations where blood vessels are absent such as in articular cartilage.