970 resultados para body measurements


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective was to evaluate the influence of dental metallic artefacts on implant sites using multislice and cone-beam computed tomography techniques. Ten dried human mandibles were scanned twice by each technique, with and without dental metallic artefacts. Metallic restorations were placed at the top of the alveolar ridge adjacent to the mental foramen region for the second scanning. Linear measurements (thickness and height) for each cross-section were performed by a single examiner using computer software. All mandibles were analysed at both the right and the left mental foramen regions. For the multislice technique, dental metallic artefact produced an increase of 5% in bone thickness and a reduction of 6% in bone height; no significant differences (p > 0.05) were detected when comparing measurements performed with and without metallic artefacts. With respect to the cone-beam technique, dental metallic artefact produced an increase of 6% in bone thickness and a reduction of 0.68% in bone height. No significant differences (p > 0.05) were observed when comparing measurements performed with and without metallic artefacts. The presence of dental metallic artefacts did not alter the linear measurements obtained with both techniques, although its presence made the location of the alveolar bone crest more difficult.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective. The purpose of this research was to provide further evidence to demonstrate the precision and accuracy of maxillofacial linear and angular measurements obtained by cone-beam computed tomography (CBCT) images. Study design. The study population consisted of 15 dry human skulls that were submitted to CBCT, and 3-dimensional (3D) images were generated. Linear and angular measurements based on conventional craniometric anatomical landmarks, and were identified in 3D-CBCT images by 2 radiologists twice each independently. Subsequently, physical measurements were made by a third examiner using a digital caliper and a digital goniometer. Results. The results demonstrated no statistically significant difference between inter-and intra-examiner analysis. Regarding accuracy test, no statistically significant differences were found of the comparison between the physical and CBCT-based linear and angular measurements for both examiners (P = .968 and .915, P = .844 and .700, respectively). Conclusions. 3D-CBCT images can be used to obtain dimensionally accurate linear and angular measurements from bony maxillofacial structures and landmarks. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2009; 108: 430-436)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Evidence indicates that endogenous opioids play a role in body temperature (Tb) regulation in mammals but no data exist about the involvement of the specific opioid receptors, mu, kappa and delta, in the reduction of Tb induced by hypoxia. Thus, we investigated the participation of these opioid receptors in the anteroventral preoptic region (AVPO) in hypoxic decrease of Th. To this end, Th of unanesthetized Wistar rats was monitored by temperature data loggers before and after intra-AVPO microinjection of the selective kappa-opioid receptor antagonist nor-binaltorphimine dihydrochloride (nor-BNI; 0.1 and 1.0 mu g/100 nL/animal), the selective mu-opioid receptor antagonist D-Phe-Cys-Tyr-D-Trp-Arg-Thr-Pen-Thr-NH(2) cyclic (CTAP; 0.1 and 1.0 mu g/100 nL/animal), and the selective delta-opioid receptor antagonist Naltrindole (0.06 and 0.6 mu g/100 nL/animal) or saline (vehicle, 100 nu animal), during normoxia and hypoxia (7% inspired O(2)). Under normoxia, no effect of opioid antagonists on Th was observed. Hypoxia induced Th to reduce in vehicle group, a response that was inhibited by the microinjection intra-AVPO of nor-BNI. In contrast, CTAP and Naltrindole did not change Th during hypoxia but caused a longer latency for the return of Th to the normoxic values just after low O(2) exposure. Our results indicate the kappa-opioid receptor in the AVPO is important for the reduction of Th during hypoxia while the mu and delta receptors are involved in the increase of Th during normoxia post-hypoxia. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this study was to evaluate the bone repair along a mandibular body osteotomy after using a 2.0 miniplate system. Nine adult mongrel dogs were subjected to unilateral continuous defect through an osteotomy between the mandibular 3rd and 4th premolars. Two four-hole miniplates were placed in accordance with the Arbeitgeimeinschaft fur Osteosynthesefragen Manual. Miniplates adapted to the alveolar processes were fixed monocortically with 6.0-mm-length titanium alloy self-tapping screws, whereas miniplates placed near the mandible bases were fixed bicortically. At 2, 6 and 12 weeks, three dogs were sacrificed per period, and the osteotomy sites were removed, divided into three thirds (Tension Third, TT; Intermediary Third, IT; Compression Third, CT) and prepared for conventional and polarized light microscopy. At 6 weeks, while the CT repaired faster and showed bone union by woven bone formation, the TT and IT exhibited a ligament-like fibrous connective tissue inserted in, and connecting, newly formed woven bone overlying the parent lamellar bone edges. At 12 weeks, bone repair took place at all thirds. Histometrically, proportions of newly formed bone did not alter at TT, IT and CT, whereas significantly enhanced bone formation was observed for the 12-week group, irrespective of the third. The results demonstrated that although the method used to stabilize the mandibular osteotomy allowed bone repair to occur, differences in the dynamics of bone healing may take place along the osteotomy site, depending on the action of tension and compression forces generated by masticatory muscles.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: Although increased body mass is an established risk factor for a variety of cancers, its relation with cancer of the ovary is unclear. We therefore investigated the association between measures of body mass index (BMI) and ovarian cancer risk. Methods: Data from an Australian case-control study of 775 ovarian cancer cases and 846 controls were used to examine the association with BMI. We have also summarized the results from a number of other studies that have examined this association. Results: There was a significant increased risk of ovarian cancer with increasing BMI, with women in the top 15% of the BMI range having an odds ratio (OR) of 1.9 (95% confidence interval (CI), 1.3-2.6) compared with those in the middle 30%. Stratifying by physical activity showed a stronger effect among inactive women (OR = 3.0, 95% CI 1.3-6.9). The overall effect was consistent with the findings of most prior population-based case-control studies, while cohort studies reported positive effects closer to the null. Hospital-based studies gave variable results. Conclusions: Taken together, the evidence is in favor of a small to moderate positive relation between high BMI and occurrence of ovarian cancer.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Statement of purpose: Increased resting energy expenditure following head injury is well documented, but whether this increase extends into rehabilitation and whether this is affected by changes in body composition have not been studied. The aim of this study was to determine whether children attending a rehabilitation program following head injury had altered energy expenditure and body composition. Methods: Measurements of resting energy expenditure by indirect calorimetry were performed in 21 head injured children (mean age 10.2±3.8 years). Measurement of body composition was performed using total body potassium. Results: Measured resting energy expenditure values were widely distributed, ranging from 52.3-156.4% of predicted values, yet the mean percentage predicted using Schofield weight, Schofield weight and height and World Health Organization predictive equations were 97.5%, 97.4% and 98.6%, respectively. Mean percentage of expected total body potassium for weight, height and age for head injured children were 85.1 ± 15.5%, 89.1 ± 14.1% and 86.9 ± 15.9%, thus all showed significant depletion. Conclusions: During rehabilitation, using predictive equations to estimate resting energy expenditure in this group revealed a small bias on average but very large bias at the individual level. Head injured children had altered resting energy expenditure and body composition.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective was to investigate the genetic epidemiology of figural stimuli. Standard figural stimuli were available from 5,325 complete twin pairs: 1,751 (32.9%) were monozygotic females, 1,068 (20.1%) were dizygotic females, 752 (14.1%) were monozygotic males, 495 (9.3%) were dizygotic males, and 1,259 (23.6%) were dizygotic male-female pairs. Univariate twin analyses were used to examine the influences on the individual variation in current body size and ideal body size. These data were analysed separately for men and women in each of five age groups. A factorial analysis of variance, with polychoric correlations between twin pairs as the dependent variable, and age, sex, zygosity, and the three interaction terms (age x sex, age x zygosity, sex x zygosity) as independent variables, was used to examine trends across the whole data set. Results showed genetic influences had the largest impact on the individual variation in current body size measures, whereas non-shared environmental influences were associated with the majority of individual variation in ideal body size. There was a significant main effect of zygosity (heritability) in predicting polychoric correlations for current body size and body dissatisfaction. There was a significant main effect of gender and zygosity in predicting ideal body size, with a gender x zygosity interaction. In common with BMI, heritability is important in influencing the estimation of current body size. Selection of desired body size for both men and women is more strongly influenced by environmental factors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Birthweight affects neonatal mortality and morbidity and has been used as a marker of foetal undernutrition in studies of prenatal effects on adult characteristics. It is potentially influenced by genetic and environmental influences on the mother, and effects of foetal genotype, which is partially derived from the maternal genotype. Interpretations of variation in birthweight and associated characteristics as being due to prenatal environment ignore other possible modes of materno-foetal transmission. Subjects were adult twins recruited through the Australian Twin Registry, aged 17 to 87 years, and the sample comprised 1820 men and 4048 women. Twins reported their own birthweight as part of a health questionnaire. Body Mass Index (BMI) was calculated from self-reports of height and weight. Correlations between co-twins' birthweights were high for both monozygotic (r = 0.77) and dizygotic (r = 0.67) pairs, leading to substantial estimates of shared environmental effects (56% of variance) with significant additive genetic (23%) and non-shared environmental (21%) components. Adult BMI was mainly influenced by genetic factors, both additive (36% of variance) and nonadditive (35%). The correlation between birthweight and BMI was positive, in that heavier babies became on average more obese adults. A bivariate model of birthweight and adult BMI showed significant positive genetic (rg = 0.16, p = 0.005) and environmental (re = 0.08, p = 0.000011) correlations. Intra-uterine environmental or perinatal influences shared by cotwins exercise a strong influence on birthweight, but the factors which affect both birthweight and adult BMI are partly genetic and partly non-shared environmental.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Shock-tunnel experiments have been performed to measure the effect on skin-friction drag in a supersonic combustor of flow disturbances induced by hydrogen fuel injection transverse to the airstream. Constant-area, circular cross section combustors of lengths varying up to 0.52 m were employed. The experiments were done at a stagnation enthalpy of 7.2 MJ . kg(-1) and a Mach number of 4.3, with a boundary layer that was turbulent downstream of the 0.14-m station in the combustors. Combustor skin-friction drag was measured by a method based on the stress wave force balance, the method being validated by agreement between fuel-off skin-friction drag measurements and predictions using existing skin-friction theories. When fuel was injected, it was found that the drag remained at fuel-off values. Thus, the streamwise vortices and other flow disturbances induced by the fuel injection, mixing, and combustion, which are expected to be present in a scramjet combustor, did not influence the skin-friction drag of the combustors.