792 resultados para biased measurement
Resumo:
In this paper we provide a formal account for underapplication of vowel reduction to schwa in Majorcan Catalan loanwords and learned words. On the basis of the comparison of these data with those concerning productive derivation and verbal inflection, which show analogous patterns, in this paper we also explore the existing and not yet acknowledged correlation between those processes that exhibit a particular behaviour in the loanword phonology with respect to the native phonology of the language, those processes that show lexical exceptions and those processes that underapply due to morphological reasons. In light of the analysis of the very same data and taking into account the aforementioned correlation, we show how there might exist a natural diachronic relation between two kinds of Optimality Theory constraints which are commonly used but, in principle, mutually exclusive: positional faithfulness and contextual markedness constraints. Overall, phonological productivity is proven to be crucial in three respects: first, as a context of the grammar, given that «underapplication» is systematically found in what we call the productive phonology of the dialect (including loanwords, learned words, productive derivation and verbal inflection); second, as a trigger or blocker of processes, in that the productivity or the lack of productivity of a specific process or constraint in the language is what explains whether it is challenged or not in any of the depicted situations, and, third, as a guiding principle which can explain the transition from the historical to the synchronic phonology of a linguistic variety.
Resumo:
Tämän diplomityön tarkoituksena oli asentaa ja kehittää UPM-Kymmene Rauman tehtaiden PK2:lle luotettava ja toimiva ilmanläpäisyprofiilin mittaus. Työn tarkoituksena oli myös kartoittaa tietoja ilmanläpäisyprofiiliin vaikuttavista seikoista sekä mahdollisuuksista säätää ilmanläpäisyprofiilia. Lisäksi työn tavoitteena oli löytää toimiva menetelmä verrata online mitattua ilmanläpäisyprofiilia laboratoriossa mitattuun ilmanläpäisyprofiiliin online mittauksen luotettavuuden näkökulmasta. Työn aikana selvitettiin myös ilmanläpäisyprofiilin mittauksen mahdollisuutta superkalanteroidusta SC paperista. Työn kirjallisessa osassa käsiteltiin paperin huokoisuutta ja ilmanläpäisyä, huokoisuustasoon ja huokoisuus profiiliin vaikuttavia tekijöitä, ilmanläpäisevyyden merkitystä SC paperin valmistukselle ja SC paperin painettavuudelle sekä ilmanläpäisevyyden laboratorio- sekä online mittausta. Kirjallisessa osassa käsiteltiin myös Honeywellin uutta Poros ilmanläpäisysensoria. Työn kokeellisessa osassa tutkittiin ilmanläpäisyprofiilimittauksen luotettavuutta CD ja MD suunnassa sekä laboratorio- ja online-mittausten välisiä eroavaisuuksia ennen PK2 uusintaa. PK2 uusinnan jälkeen kokeellisessa osassa keskityttiin luotettavuuden varmentamiseen CD ja MD suunnassa sekä kartoittamaan tekijöitä, jotka aiheuttivat pieniä tasoeroja mittausten välillä. Mittaukset todettiin luotettaviksi ja niiden pohjalta suoritettiin mitattujen online profiilien välisiä vertailuja. Ilmanläpäisyprofiililla todettiin olevan positiivinen korrelaatio neliömassaprofiilin ja kosteusprofiilin kanssa sekä negatiivinen korrelaatio tuhkaprofiilin kanssa. PK2 uusinnan yhteydessä tehtiin koeajoja, jotka liittyivät laadunoptimointiin viira- ja puristinosalla. Koeajoissa tutkittujen asioiden lisäksi tutkittiin muutettujen parametrien vaikutusta ilmanläpäisyprofiiliin. Höyrylaatikon vaikutusta ilmanläpäisyprofiiliin tutkittiin säätöjen virityksen yhteydessä.
Resumo:
BACKGROUND: The presence of intraspecific color polymorphism can have multiple impacts on the ecology of a species; as a consequence, particular color morphs may be strongly selected for in a given habitat type. For example, the asp viper (Vipera aspis) shows a high level of color polymorphism. A blotched morph (cryptic) is common throughout its range (central and western Europe), while a melanistic morph is frequently found in montane populations, presumably for thermoregulatory reasons. Besides, rare atypical uniformly colored individuals are known here and there. Nevertheless, we found in a restricted treeless area of the French Alps, a population containing a high proportion (>50%) of such specimens. The aim of the study is to bring insight into the presence and function of this color morph by (i) studying the genetic structure of these populations using nine microsatellite markers, and testing for (ii) a potential local diversifying selection and (iii) differences in dispersal capacity between blotched and non-blotched vipers. RESULTS: Our genetic analyses support the occurrence of local diversifying selection for the non-blotched phenotype. In addition, we found significant color-biased dispersal, blotched individuals dispersing more than atypical individuals. CONCLUSION: We hypothesize that, in this population, the non-blotched phenotype possess an advantage over the typical one, a phenomenon possibly due to a better background matching ability in a more open habitat. In addition, color-biased dispersal might be partly associated with the observed local diversifying selection, as it can affect the genetic structure of populations, and hence the distribution of color morphs.
Resumo:
BACKGROUND: Left atrial (LA) dilatation is associated with a large variety of cardiac diseases. Current cardiovascular magnetic resonance (CMR) strategies to measure LA volumes are based on multi-breath-hold multi-slice acquisitions, which are time-consuming and susceptible to misregistration. AIM: To develop a time-efficient single breath-hold 3D CMR acquisition and reconstruction method to precisely measure LA volumes and function. METHODS: A highly accelerated compressed-sensing multi-slice cine sequence (CS-cineCMR) was combined with a non-model-based 3D reconstruction method to measure LA volumes with high temporal and spatial resolution during a single breath-hold. This approach was validated in LA phantoms of different shapes and applied in 3 patients. In addition, the influence of slice orientations on accuracy was evaluated in the LA phantoms for the new approach in comparison with a conventional model-based biplane area-length reconstruction. As a reference in patients, a self-navigated high-resolution whole-heart 3D dataset (3D-HR-CMR) was acquired during mid-diastole to yield accurate LA volumes. RESULTS: Phantom studies. LA volumes were accurately measured by CS-cineCMR with a mean difference of -4.73 ± 1.75 ml (-8.67 ± 3.54%, r2 = 0.94). For the new method the calculated volumes were not significantly different when different orientations of the CS-cineCMR slices were applied to cover the LA phantoms. Long-axis "aligned" vs "not aligned" with the phantom long-axis yielded similar differences vs the reference volume (-4.87 ± 1.73 ml vs. -4.45 ± 1.97 ml, p = 0.67) and short-axis "perpendicular" vs. "not-perpendicular" with the LA long-axis (-4.72 ± 1.66 ml vs. -4.75 ± 2.13 ml; p = 0.98). The conventional bi-plane area-length method was susceptible for slice orientations (p = 0.0085 for the interaction of "slice orientation" and "reconstruction technique", 2-way ANOVA for repeated measures). To use the 3D-HR-CMR as the reference for LA volumes in patients, it was validated in the LA phantoms (mean difference: -1.37 ± 1.35 ml, -2.38 ± 2.44%, r2 = 0.97). Patient study: The CS-cineCMR LA volumes of the mid-diastolic frame matched closely with the reference LA volume (measured by 3D-HR-CMR) with a difference of -2.66 ± 6.5 ml (3.0% underestimation; true LA volumes: 63 ml, 62 ml, and 395 ml). Finally, a high intra- and inter-observer agreement for maximal and minimal LA volume measurement is also shown. CONCLUSIONS: The proposed method combines a highly accelerated single-breathhold compressed-sensing multi-slice CMR technique with a non-model-based 3D reconstruction to accurately and reproducibly measure LA volumes and function.
Resumo:
Tämä työ käsittelee puutukkien tilavuuden mittaamista värikonenäön avulla. Värikuvat on saatu Simpeleellä olevan metsäteollisuusyrityksen hiomosta. Työssä esitetään perusteellisesti matemaattinen teoria, joka liittyy käytettyihin kuvankäsittelymenetelmiin, kuten luokitteluun, kohinan poistoon ja tukkien segmentointiin. Esitetyt menetelmät implementointiin käytännössä ja eri menetelmillä saatuja tuloksia vertailtiin keskenään. Kuvankäsittelyalgoritmit on implementoitu Matlab 6.0:n avulla. Pääasiassa käytettiin uusinta Image Processing Toolboxia, joka on versio 3.0. Tämä työn näkökulma on pääasiassa käytäntöön soveltava, koska metsäteollsuus on korkealla tasolla Suomessa ja siellä on paljon alan yrityksiä, joissa tässä työssä kehitettyä menetelmää voidaan hyödyntää.
Resumo:
Tässä tutkimuksessa kehitettiin prototyyppi betonielementin dimension mittaus järjestelmästä. Tämä järjestelmä mahdollistaa kolmiulotteisen kappaleen mittauksen. Tutkimuksessa kehitettiin myös stereonäköön perustuva kappaleen mittaus. Prototyyppiä testailin ja tulokset osoittautuivat luotettaviksi. Tutkimuksessa selvitetään ja vertaillaan myös muita lähestymistapoja ja olemassa olevia järjestelmiä kappaleen kolmiuloitteiseen mittaukseen, joita Suomalaiset yhtiöt käyttävät tällä alalla.
Resumo:
Electrical impedance tomography (EIT) allows the measurement of intra-thoracic impedance changes related to cardiovascular activity. As a safe and low-cost imaging modality, EIT is an appealing candidate for non-invasive and continuous haemodynamic monitoring. EIT has recently been shown to allow the assessment of aortic blood pressure via the estimation of the aortic pulse arrival time (PAT). However, finding the aortic signal within EIT image sequences is a challenging task: the signal has a small amplitude and is difficult to locate due to the small size of the aorta and the inherent low spatial resolution of EIT. In order to most reliably detect the aortic signal, our objective was to understand the effect of EIT measurement settings (electrode belt placement, reconstruction algorithm). This paper investigates the influence of three transversal belt placements and two commonly-used difference reconstruction algorithms (Gauss-Newton and GREIT) on the measurement of aortic signals in view of aortic blood pressure estimation via EIT. A magnetic resonance imaging based three-dimensional finite element model of the haemodynamic bio-impedance properties of the human thorax was created. Two simulation experiments were performed with the aim to (1) evaluate the timing error in aortic PAT estimation and (2) quantify the strength of the aortic signal in each pixel of the EIT image sequences. Both experiments reveal better performance for images reconstructed with Gauss-Newton (with a noise figure of 0.5 or above) and a belt placement at the height of the heart or higher. According to the noise-free scenarios simulated, the uncertainty in the analysis of the aortic EIT signal is expected to induce blood pressure errors of at least ± 1.4 mmHg.
Resumo:
Issue ownership means that some parties are considered by the public at large as being more able to deal with, or more attentive to, certain issues. The theory has been used to explain both party behaviour - parties are expected to focus on owned issues - and voter behaviour - when a voter considers a party to own an issue, this affects the odds of voting for that party. The purpose of this article is, first, to provide a look backward at the existing research through a literature review of the studies that were conducted in the past decade-and-a-half. Secondly, it takes stock of the current conceptualisation and argues that issue ownership is a multidimensional concept. Thereafter the article discusses how this multidimensionality affects both the role of issue ownership in voter and in party behaviour. Finally, the article outlines a number of shortcomings of the extant literature and discusses potential avenues for future research.
Resumo:
Background In an agreement assay, it is of interest to evaluate the degree of agreement between the different methods (devices, instruments or observers) used to measure the same characteristic. We propose in this study a technical simplification for inference about the total deviation index (TDI) estimate to assess agreement between two devices of normally-distributed measurements and describe its utility to evaluate inter- and intra-rater agreement if more than one reading per subject is available for each device. Methods We propose to estimate the TDI by constructing a probability interval of the difference in paired measurements between devices, and thereafter, we derive a tolerance interval (TI) procedure as a natural way to make inferences about probability limit estimates. We also describe how the proposed method can be used to compute bounds of the coverage probability. Results The approach is illustrated in a real case example where the agreement between two instruments, a handle mercury sphygmomanometer device and an OMRON 711 automatic device, is assessed in a sample of 384 subjects where measures of systolic blood pressure were taken twice by each device. A simulation study procedure is implemented to evaluate and compare the accuracy of the approach to two already established methods, showing that the TI approximation produces accurate empirical confidence levels which are reasonably close to the nominal confidence level. Conclusions The method proposed is straightforward since the TDI estimate is derived directly from a probability interval of a normally-distributed variable in its original scale, without further transformations. Thereafter, a natural way of making inferences about this estimate is to derive the appropriate TI. Constructions of TI based on normal populations are implemented in most standard statistical packages, thus making it simpler for any practitioner to implement our proposal to assess agreement.
Resumo:
Reaching a consensus in terms of interchangeability and utility (i.e., disease detection/monitoring) of a medical device is the eventual aim of repeatability and agreement studies. The aim of the tolerance and relative utility indices described in this report is to provide a methodology to compare change in clinical measurement noise between different populations (repeatability) or measurement methods (agreement), so as to highlight problematic areas. No longitudinal data are required to calculate these indices. Both indices establish a metric of least to most effected across all parameters to facilitate comparison. If validated, these indices may prove useful tools when combining reports and forming the consensus required in the validation process for software updates and new medical devices.
Resumo:
Jatkuva laadunmittaus osana ohjelmistoprosessia on yleistynyt ohjelmistoyritysten keskuudessa viime vuosien aikana. ISO 9001:2000 -laatustandardi vaatii yrityksiltä tuotteiden ja prosessien laadun mittaamista ja seuraamista. Laadun mittareiden valinta on haastava tehtävä. Yritykset luulevat usein mittaavansa laatua, vaikka ne todellisuudessa mittaavatkin ohjelmistojen eri ominaisuuksia kuten kokoa tai monimutkaisuutta. Tässä diplomityössä kehitetään ohjelmistojen validointiprosessiin vertailuun perustuva laadunmittausprosessi ohjelmistotuotteiden laadun arviointiin, mittaamiseen ja seurantaan. Laatumittarit valitaan ennalta määriteltyjen kriteereiden mukaisesti, ja niille asetetaan tavoitearvot vertailuanalyysistä saatujen tulosten perusteella. Laadunmittausprosessin lisäksi työssä annetaan suositus prosessin käyttöönotosta ja käytöstä osana yrityksen toimintaa, mikä mahdollistaa jatkuvan seurannan sekä kehityksen tulevaisuudessa.
Resumo:
Tämän työn tarkoituksena on koota yhteen selluprosessin mittausongelmat ja mahdolliset mittaustekniikat ongelmien ratkaisemiseksi. Pääpaino on online-mittaustekniikoissa. Työ koostuu kolmesta osasta. Ensimmäinen osa on kirjallisuustyö, jossa esitellään nykyaikaisen selluprosessin perusmittaukset ja säätötarpeet. Mukana on koko kuitulinja puunkäsittelystä valkaisuun ja kemikaalikierto: haihduttamo, soodakattila, kaustistamo ja meesauuni. Toisessa osassa mittausongelmat ja mahdolliset mittaustekniikat on koottu yhteen ”tiekartaksi”. Tiedot on koottu vierailemalla kolmella suomalaisella sellutehtaalla ja haastattelemalla laitetekniikka- ja mittaustekniikka-asiantuntijoita. Prosessikemian paremmalle ymmärtämiselle näyttää haastattelun perusteella olevan tarvetta, minkä vuoksi konsentraatiomittaukset on valittu jatkotutkimuskohteeksi. Viimeisessä osassa esitellään mahdollisia mittaustekniikoita konsentraatiomittausten ratkaisemiseksi. Valitut tekniikat ovat lähi-infrapunatekniikka (NIR), fourier-muunnosinfrapunatekniikka (FTIR), online-kapillaarielektroforeesi (CE) ja laserindusoitu plasmaemissiospektroskopia (LIPS). Kaikkia tekniikoita voi käyttää online-kytkettyinä prosessikehitystyökaluina. Kehityskustannukset on arvioitu säätöön kytketylle online-laitteelle. Kehityskustannukset vaihtelevat nollasta miestyövuodesta FTIR-tekniikalle viiteen miestyövuoteen CE-laitteelle; kehityskustannukset riippuvat tekniikan kehitysasteesta ja valmiusasteesta tietyn ongelman ratkaisuun. Työn viimeisessä osassa arvioidaan myös yhden mittausongelman – pesuhäviömittauksen – ratkaisemisen teknis-taloudellista kannattavuutta. Ligniinipitoisuus kuvaisi nykyisiä mittauksia paremmin todellista pesuhäviötä. Nykyään mitataan joko natrium- tai COD-pesuhäviötä. Ligniinipitoisuutta voidaan mitata UV-absorptiotekniikalla. Myös CE-laitetta voitaisiin käyttää pesuhäviön mittauksessa ainakin prosessikehitysvaiheessa. Taloudellinen tarkastelu pohjautuu moniin yksinkertaistuksiin ja se ei sovellu suoraan investointipäätösten tueksi. Parempi mittaus- ja säätöjärjestelmä voisi vakauttaa pesemön ajoa. Investointi ajoa vakauttavaan järjestelmään on kannattavaa, jos todellinen ajotilanne on tarpeeksi kaukana kustannusminimistä tai jos pesurin ajo heilahtelee eli pesuhäviön keskihajonta on suuri. 50 000 € maksavalle mittaus- ja säätöjärjestelmälle saadaan alle 0,5 vuoden takaisinmaksuaika epävakaassa ajossa, jos COD-pesuhäviön vaihteluväli on 5,2 – 11,6 kg/odt asetusarvon ollessa 8,4 kg/odt. Laimennuskerroin vaihtelee tällöin välillä 1,7 – 3,6 m3/odt asetusarvon ollessa 2,5 m3/odt.
Resumo:
Asiakastyytyväisyys on läheisesti yhteydessä yrityksen taloudelliseen menestykseen ja yrityksen yleisen laadun määrittämiseen. Asiakastyytyväisyyden mittaamista vaaditaan tällä hetkellä myös ISO 9001 laatujärjestelmästandardissa. Tämän vuoksi tarve tutkia ja mitata asiakastyytyväisyyttä on kasvanut yritysten ja yhteisöjen joukossa. Kokonaisvaltainen asiakastyytyväisyyden tutkiminen sisältää sekä asiakastyytyväisyyden mittaamista ja järjestelmällistä asiakaspalautteen tutkimista ja analysointia. Asiakastyytyväisyysmittaamisessa käytetään menettelytapoja ja tekniikoita, jotka ovat yleisesti käytössä markkinointitutkimuksessa. Menetelmiä on kuitenkin mukautettava, jotta ne sopivat asiakastyytyväisyyden mittaamiseksi. Asiakastyytyväisyysmittaustulosten perusanalyysit ovat helppo toteuttaa mutta tulokset voidaan helposti tulkita väärin ilman syvällisempiä tilastomatemaattisia analyysejä. Asiakastyytyväisyyden mittaaminen on helppo toteuttaa mutta tutkimussuunnitelma ja tulostenkeräysmenetelmä pitää suunnitella huolellisesti, jotta mittaustulosten luotettavuus ja validiteetti voidaan taata. Jotta asiakastyytyväisyyden tutkimisesta saataisiin maksimaalinen hyöty, pitäisi tutkimuksen myös tarkastella kuinka asiakastyytyväisyys, yrityksen sisäinen ja ulkoinen laatu sekä asiakaslojaalisuus ovat yhteydessä toisiinsa.