577 resultados para Valves


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Mode of access: Internet.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Editor: July 1912- J. W. McEachren.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Thesis (Master's)--University of Washington, 2016-06

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: Cardiac impairment is frequently found in babies of diabetic mothers. It is still controversial whether this is due to poor glucose control. The aim of this study is to compare the cardiac function in fetuses of well- and poorly-controlled pre-gestational diabetic pregnancy in third trimester. Methods:Women with type 1 pre-gestational diabetes were enrolled at 30-32 weeks. Cardiac size and interventricular septal wall thickness were measured by M-mode at end-diastolic phase. The right and left ventricular ejection fractions were calculated. At the mitral and tricuspid valves inflow, the ratio between early ventricular filling and active atrial filling (E/A) at both atrioventricular valves were measured by Doppler echocardiography. Peak velocities of ascending aorta and pulmonary artery were assessed. The angle of isonation was kept at 6.5%) were compared with those with satisfactorily controlled diabetes (HbA1c less than or equal to 6.5%). Results: A total of 21 women with pre-gestational diabetes were recruited for this study. Eight women with well-controlled diabetes were compared with 9 women who had poorly-controlled diabetes. HbA1c in the poorly-controlled group was 7.3% and in the well-controlled group it was 5.4% (p < 0.001). There was no difference between the two groups in cardiac size, interventricular septal wall thickness, ejection fraction, aorta and pulmonary artery peak flow velocities. The right atrioventricular E/A ratio was significantly lower among the poorly-controlled diabetic pregnancies (0.71 vs. 0.54; p < 0.05). Conclusion: Fetuses of poorly-controlled diabetic mothers had a lower right atrioventricular E/A ratio. This may be due to metabolic acidosis, non-hypertrophic cardiac dysfunction or fetal polycythemia. Copyright (C) 2003 S. Karger AG, Basel.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background. The development of therapeutic interventions to prevent progressive valve damage is more likely to limit the progression of structural damage to the aortic valve with normal function (aortic sclerosis [ASC]) than clinically apparent aortic stenosis. Currently, the ability to appreciate the progression of ASC is compromised by the subjective and qualitative evaluation of sclerosis severity. Methods: We sought to reveal whether the intensity of ultrasonic backscatter could be used to quantify sclerosis severity in 26 patients with ASC and 23 healthy young adults. images of the aortic valve were obtained in the parasternal long-axis view and saved in raw data format. Six square-shaped 11 X 11 pixel regions of interest were placed on the anterior and posterior leaflets, and calibrated backscatter values were obtained by subtracting the regions of interest in the blood pool from the averaged backscatter values obtained from the leaflets. Results. Mean ultrasonic backscatter values for sclerotic valves exceeded the results in normal valve tissue (16.3 +/- 4.4 dB vs 9.8 +/- 3.3 dB, P < .0001). Backscatter values were greater (22.0 +/- 3.5 dB) in a group of 6 patients with aortic stenosis. Within the sclerosis group, the magnitude of backscatter was directly correlated (P < .05) with a subjective sclerosis score, and with transvalvular pressure gradient. mean reproducibility was 2.4 +/- 1.8 dB (SD) between observers, and 2.3 +/- 1.7 dB (SD) between examinations. Conclusion: Measurement of backscatter from the valve leaflets of patients with ASC may be a feasible means of following the progression and treatment response of aortic sclerosis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective To determine the range of various cardiac parameters using echocardiography in apparently normal, healthy English Bull Terriers. Design Fourteen English Bull Terriers were selected for study. Cardiac auscultation of the parents of these dogs was normal. Echocardiographic examination of one parent of each animal showed: no mitral or aortic valve abnormalities; no myocardial lesions; no two dimensional evidence of fixed or dynamic left ventricular outflow tract obstruction; and no systolic aortic or left ventricular outflow tract turbulence on colour flow Doppler examination. The 14 selected dogs did not have arrhythmias or murmurs, and on echocardiographic examination had similar findings to their parents. Systolic blood pressure was measured in all dogs and they had no clinical evidence of Bull Terrier polycystic kidney disease or Bull Terrier hereditary nephritis. Procedure All dogs were auscultated and subjected to a sequential global echocardiographic assessment of the heart, including two dimensional long and short axis, and colour flow Doppler interrogation of the mitral and aortic valves. Dimensional measurements, including those from the left atrium, aortic annulus and left ventricle, were taken from a right parasternal window, and derived values such as fractional shortening, stroke volume and left atrial to aortic annulus ratio were calculated. Peak systolic aortic velocity was measured from the left parasternal window using two dimensional-guided pulsed wave Doppler with angle correction. Systolic blood pressure was measured using a Doppler monitor. The absence of Bull Terrier polycystic kidney disease was determined using renal ultrasonography, and of Bull Terrier hereditary nephritis using urinary protein to creatinine ratio. Results These 14 dogs had greater left ventricular wall thickness and smaller aortic root diameters than those reported as normal for other breeds of comparable body size. Left atrial dimensions were also larger, however this may have been due to the maximising method of measurement. These apparently normal English Bull Terriers also had higher aortic velocities than those reported for other breeds, possibly due to a smaller aortic root diameter or other anatomic substrate of the left ventricular outflow tract, lower systemic vascular resistance, or breed-specific normal left ventricular hypertrophy. While these dogs were selected to be as close to normal as possible, the breed may have a particular anatomy that produces abnormal left ventricular echocardiographic parameters. Conclusion These echocardiographic parameters may be used to diagnose left ventricular outflow tract obstruction and left ventricular hypertrophy, and inaccurate diagnoses may result if breed-specific values are not used.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Stem cells, either from embryonic or adult sources, have demonstrated the potential to differentiate into a wide range of tissues depending on culture conditions. This makes them prime candidates for use in tissue engineering applications. Current technology allows us to process biocompatible and biodegradable polymers into three-dimensional (3D) configurations, either as solid porous scaffolds or hydrogels, with controlled macro and/or micro spatial geometry and surface chemistry. Such control provides us with the ability to present highly controlled microenvironments to a chosen cell type. However, the precise microenvironments required for optimal expansion and/or differentiation of stem cells are only now being elucidated, and hence the controlled use of stem cells in tissue engineering remains a very young field. We present here a brief review of the current literature detailing interactions between stem cells and 3D scaffolds of varying morphology and chemical properties, concluding with remaining challenges for those interested in tissue engineering using tailored scaffolds and stem cells.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We evaluated the hydrodynamic performance of kangaroo aortic valve matrices (KMs) (19, 21, and 23 mm), as potential scaffolds in tissue valve engineering using a pulsatile left heart model at low and high cardiac outputs (COs) and heart rates (HRs) of 60 and 90 beats/min. Data were measured in two samples of each type, pooled in two CO levels (2.1 +/- 0.7 and 4.2 +/- 0.6 L/min; mean +/- standard errors on the mean), and analyzed using analysis of variance with CO level, HR, and valve type as fixed factors and compared to similar porcine matrices (PMs). Transvalvular pressure gradient (Delta P) was a function of HR (P < 0.001) and CO (P < 0.001) but not of valve type (P = 0.39). Delta P was consistently lower in KMs but not significantly different from PMs. The effective orifice area and performance index of kangaroo matrices was statistically larger for all sizes at both COs and HRs.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Kudoa monodactyli n. sp. is described from the somatic musculature of Monodactylus argenteus from several localities in southern Queensland, Australia. This is the first record of a myxozoan parasite from the family Monodactylidae. The spores typically have five polar capsules, making this species similar to the four other five-valved Kudoa species (K. neurophila, K. muscularis, K. shulmani, K. cutanea) that have been described to date. However, morphometric measurements particularly of spore length and width make the species from M. argenteus distinct from the other species. Comparison of the small subunit ribosomal DNA sequence of this species with its congeners for which sequence data are available, provides further evidence of novelty. Kudoa monodactyli n. sp. displays 38 (of 1,554) nucleotide differences compared with rDNA sequence of Kudoa neurophila, which on phylogenetic analysis places these species in clades exclusive of each other. Phylogenetic analyses also provide evidence that the number of valves per spore in this genus is an imperfect indicator of relatedness.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A 52-year-old male with idiopathic hypereosinophilic syndrome (HES) was transferred to our institution following the development of acute respiratory failure and shock. He had previously undergone tricuspid valve replacement with bioprosthetic valves on two occasions: the initial surgery for severe native tricuspid valve stenosis and the redo surgery for severe prosthetic valve stenosis and regurgitation. Conventional imaging assessment using transoesophageal echocardiography was suboptimal and comprehensive assessment of prosthetic valve function was aided by the use of intracardiac echocardiography (ICE). ICE provided high quality 2D imaging of the prosthesis demonstrating thrombus-like material coating the inner surfaces of the prosthetic valve stents effectively forming a tunnel-like obstruction. Unusual hemodynamics secondary to severe tricuspid stenosis were demonstrated by CW Doppler with intermittent signal fusion resulting from blunted respiratory variation in the markedly elevated right atrial pressure relative to right ventricular pressure. Successful balloon valvuloplasty was performed with ICE proving highly valuable in guiding balloon position as well as monitoring the efficacy of the subsequent inflations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Staphylococcus epidermidis causes infections associated with medical devices including central venous catheters, orthopaedic prosthetic joints and artificial heart valves. This coagulase-negative Staphylococcus produces a conventional cellular lipoteichoic acid (LTA) and also releases a short-glycerophosphate-chain-length form of LTA (previously termed lipid S) into the medium during growth. The relative pro-inflammatory activities of cellular and short-chain-length exocellular LTA were investigated in comparison with peptidoglycan and wall teichoic acid from S. epidermidis and LPS from Escherichia coli O111. The ability of these components to stimulate the production of proinflammatory cytokines [interleukin (IL)-1β, IL-6 and tumour necrosis factor (TNF)-α] and nitric oxide was investigated in a murine macrophage-like cell line (J774.2), and in peritoneal and splenic macrophages. On a weight-for-weight basis the short-chain-length exocellular LTA was the most active of the S. epidermidis products, stimulating significant amounts of each of the inflammatory cytokines and nitric oxide, although it was approximately 100-fold less active than LPS from E. coli. By comparison the full-chain-length cellular LTA and peptidoglycan were less active and the wall teichoic acid had no activity. As an exocellular product potentially released from S. epidermidis biofilms, the short-chain-length exocellular LTA may act as the prime mediator of the host inflammatory response to device-related infection by this organism and act as the Gram-positive equivalent of LPS in Gram-negative sepsis. The understanding of the role of short-chain-length exocellular LTA in Gram-positive sepsis may lead to improved treatment strategies. © 2005 SGM.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PCR with broad-range primers for prokaryotic 16S rRNA genes was used to identify bacterial DNA in tissue from patients undergoing valve replacements following a previous episode of infective endocarditis (IF). Of eight valves investigated, bacterial DNA was detected in three from patients for whom IE had been treated by antibiotic therapy 5, 12 and 18 months previously. The demonstration of bacterial DNA within resected heart valves suggests either recurrence of infection, treatment failure or the persistence of bacterial debris within the cardiac vegetation. There may also be implications for routine use of PCR in the diagnosis of infection. © 2004 Copyright by the European Society of Clinical Microbiology and Infectious Diseases.