983 resultados para URBAN AIR
Resumo:
A set of radiation measurements were carried out in several public and private institutions. These were selected with basis on the people affluence and passage to these sites. These measurements were registration formed either indoor, outdoor or underground and were compiled in three Case Studies. Radiation doses measurements were also made, surface and underground locations, and compiled in other two Case Studies. There were sampled, at the same time, humidity, temperature, atmospheric pressure and relevant construction materials at sampling locations. They were collected and registration formed to analyse if there is any relation or contribution for the measured value in each specific place. Geostatistical models were used to elaborate maps of the results both for radiation values and for doses. Preliminary relations were established among the measured parameters.
Resumo:
Bancroftian filariasis is spreading in towns of endemic areas as in Recife, northeastern Brazil, where it is a major public health problem. This paper deals with the prevalence of microfilaraemia and filarial disease in two urban areas of Recife, studying their association with individual characteristics and variables related to the exposure to the vectors. The parasitologic survey was performed through a "door-to-door" census and microfilaraemia was examined by the thick-drop technique using 45µl of peripheral blood collected between 20:00 and 24:00 o' clock. 2,863 individuals aged between 5 and 65 years were interviewed and submitted to clinical examination. Males aged between 15 and 44 years old presented the greatest risk of being microfilaraemic. Microfilaraemia was also significantly associated with no use of bednet to sleep. The risk of being microfilaraemic was greater among those who had lived in the studied areas for more than 5 years. The overall disease prevalence was 6.3%. Males presented the greatest risk of developing acute disease. The risk of developing chronic manifestations was also greater among males and increased with age. We found no association between time of residence, bednet use, microfilaraemia and acute and chronic disease. We may conclude that in endemic areas there are subgroups of individuals who has a higher risk of being microfilariae carriers due to different behaviours in relation to vector contact.
Resumo:
Dissertation submitted in partial fulfilment of the requirements for the Degree of Master of Science in Geospatial Technologies.
Resumo:
A 39-year old male patient was admitted to the University Hospital of the Faculty of Medicine of Ribeirão Preto with signs and symptoms of sudden dyspnea, generalized myalgia and behavioral disorders. The initial suspicion was alcohol abstinence syndrome and the patient was referred for psychiatric and neurologic care. The evolution of the patient with a worsening of signs and symptoms, presence of crises of tachypnea, agitation, difficulty to swallow, irritability and hydrophobia, and his report of having been bitten by a suspected dog raised the hypothesis of rabies. The diagnosis was confirmed by examination of a corneal impression, biological tests in the cerebrospinal fluid (CSF) and saliva and visualization of Negri bodies in nervous tissue (direct immunofluorescence). The patient evolved with agitation, aggressiveness, and worsening tachypnea intercalating with apnea, and died on the 4th day after admission
Consumption Management of Air Conditioning Devices for the Participation in Demand Response Programs
Resumo:
Demand Response has been taking over the years an extreme importance. There’s a lot of demand response programs, one of them proposed in this paper, using air conditioners that could increase the power quality and decrease the spent money in many ways like: infrastructures and customers energy bill reduction. This paper proposes a method and a study on how air conditioners could integrate demand response programs. The proposed method has been modelled as an energy resources management optimization problem. This paper presents two case studies, the first one with all costumers participating and second one with some of costumers. The results obtained for both case studies have been analyzed.
Resumo:
A population-based case-control design was used to investigate the association between migration, urbanisation and schistosomiasis in the Metropolitan Region of Recife, Northeast of Brazil. 1022 cases and 994 controls, aged 10 to 25, were selected. The natives and the migrants who come from endemic areas have a similar risk of infection. On the other hand, the risk of infection of migrants from nonendemic areas seems to be related with the time elapsed since their arrival in São Lourenço da Mata; those who have been living in that urban area for 5 or more years have a risk of infection similar to that of the natives. Those arriving in the metropolitan region of Recife mostly emigrate from "zona da mata" and "zona do agreste" in the state of Pernambuco. Due to the changes in the sugar agro-industry and to the increase in the area used for cattle grazing these workers were driven to villages and cities. The pattern of urbanisation created the conditions for the establishment of foci of transmission in São Lourenço da Mata.
Resumo:
No âmbito do desenvolvimento da dissertação do Mestrado de Engenharia Eletrotécnica – Sistemas Elétricos de Energia, surgiu a oportunidade de participar no desenvolvimento de um projeto integrante numa subestação de energia. O presente caso de estudo tem em vista a resolução de condicionantes na conceção desta subestação, tais como cumprir requisitos estéticos projetando todo o tipo de equipamentos dentro de edifícios, a ventilação das salas de transformação assim como insonorização de todo o ruído produzido de forma a cumprir os limites legais e não perturbar a vizinhança. A presente subestação de energia está situada numa zona urbana da cidade de Leiria, localidade de Parceiros, dando origem ao nome Subestação de Energia de Parceiros. Esta subestação pertence ao cliente Energias de Portugal, conhecida como EDP, e visa o melhoramento da distribuição do serviço eléctrico. As tradicionais subestações de energia, com aparência bastante desenquadrada dos meios urbanos, representam um entrave ao nível da aproximação destes centros de produção energética às zonas urbanas, comprometendo a melhoria da rede elétrica. Desta forma, foi implementada a tecnologia Gas-Insolated Switchgear e permite o enquadramento destes centros energéticos em zonas urbanas, constituindo mais um edifício urbano na zona onde se insere. Esta substitui os convencionais barramentos existentes nos Parques Exteriores de Aparelhagem das subestações e apresenta-se com dimensões muito reduzidas quando comparadas com as estruturas instaladas nestes parques. Dado que esta tecnologia é desenvolvida no sentido de permitir a construção destes centros energéticos em zonas urbanas, podem ser alojadas dentro de edifícios produzindo assim vantagens ao nível estético, não perturbando a paisagem. Dado que os principais equipamentos de funcionamento na subestação de Parceiros, nomeadamente o Transformador de Potência, se encontram instalados num edifício completamente fechado, foram construídas duas salas de ventilação, na parte superior deste edifício, cada uma adjacente a uma sala de transformação. O transformador instalado possui elevadas dimensões, pesando 53000 kg e contendo 11000 kg de óleo que em estado normal de funcionamento circula por quase todo o interior da máquina a elevadas temperaturas, provocando um aquecimento elevado no interior do edifício o que condiciona o bom funcionamento do transformador. Para ultrapassar esta condicionante foi realizado um estudo de um sistema de ventilação capaz de avaliar e controlar os valores térmicos existentes e proceder à circulação de ar, que será movimentado ou bloqueado, recorrendo a um sistema autónomo, mantendo a temperatura ideal nas salas de transformação. Este autómato é o cérebro de toda a cadeia lógica que, mediante as leituras efetuadas irá dar ordens de atuação aos diversos equipamentos. Apesar dos TP estarem protegidos dentro do edifício, estes produzem um maior ruído. A necessidade da existência do referido sistema de ventilação das divisões de funcionamento destas máquinas, implica a utilização de aparelhos que, apesar da sua evolução tecnológica os torna cada vez menos ruidosos, mas geram sempre alguma perturbação, o que pode representar um problema no cumprimento do regulamento geral do ruído.
Resumo:
As patients with chronic Chagas disease exhibit morphological and functional changes of the stomach (hypomotility and hypochlorhydria), malnutrition, immunological deficiency and high prevalence of peptic disease associated to Helicobater pylori infection, the purpose of this study was to evaluate if the prevalence of H. pylori infection in chronic chagasic is higher than in non-chagasic individuals in the urban and rural population from Uberlândia, MG, Brazil. Serological determination of IgG antibodies to H. pylori was performed using a second-generation ELISA. Thus, 598 people were evaluated: 128 chagasic (CG), 222 non-chagasic living in urban area (U-NCG) and 248 non-chagasic living in rural area (R-NCG). Regarding the age range from 21 to 50 years, the prevalence of H. pylori infection in the CG (85.1%) was significantly higher than in the U-NCG (56.3%, p < 0.01) and the R-NCG (67.4%, p < 0.05). In the patients over 50 years, the prevalence in the CG (86.4%) was similar to the U-NCG (78.8%) and R-NCG (86.1%). Similar results were also found between the U-NCG and R-NCG for all age ranges, with prevalence rates of 29.1% and 35.3% for the age range from 5 to 13 years, and 47.2% and 40% for that from 14 to 20 years, respectively. We conclude that chagasic patients showed a higher seroprevalence of H. pylori infection than non-chagasic individuals, in the age range from 21 to 50 years, and that the prevalence of this infection was similar in the studied urban and rural non-chagasic population.
Resumo:
Toxocara species are most common roundworms of Canidae and Felidae. Human toxocariasis develops by ingesting of embryonated eggs in contaminated soil. There is no previous report of Toxocara contamination in the soil samples from the public areas in Bangkok. For this reason our study have been carried out to examine the frequency of Toxocara eggs in public yards in Bangkok, Thailand. A total of 175 sand and clay samples were collected and examined for parasite eggs. According to this study, Toxocara eggs were detected from 10 (5.71%) of 175 soil samples. The high rate of contamination in this study implies the importance of the control of this possible zoonotic disease: control of abandon of dogs and cats, is still necessary.
Resumo:
The colony of urban stray cats living in the Rio de Janeiro zoological garden was studied in order to develop a population and health control program. As many cats as possible were captured during two months (47 animals) and were classified according to gender, age, weight and coat markings. They were submitted to a general health evaluation, examined for the presence of ectoparasites and sent to a surgical neutering program. All animals had a blood sample drawn for CBC, platelet count, heartworm and retroviruses detection. Capillary blood smears were made for hemoparasites detection. Coat marking and colors were tabby (59.7%), followed by solid black (17%); torbie (10.6%); bicolor (10.6%) and harlequin (2.1%). The only ectoparasites found were fleas, which infested 28% of the animals. The hemoparasites found were Haemobartonella felis (38%) and piroplasmas that could not be differentiated between Cytauxzoon spp. and Babesia spp. (47%). No cat was found infected by Dirofilaria immitis or FeLV (Feline Leukemia Virus), although FIV (Feline Immunodeficiency Virus) antibodies could be detected (21%). There was no correlation between hemoparasites and FIV infections. The estimated total cat population (mark-recapture method) was 59; 68% female and 32% male, suggesting that a neutering program is in fact needed.
Resumo:
The objective of this report is to describe the first record of Desmodus rotundus in urban area from the city of Olinda, Pernambuco State, Northeastern Brazil, and to draw attention to the possible risk of rabies transmission in this place. After the complaint of a dog owner who observed three bats attacking his dog, images registering attacks of D. rotundus were captured with a video camera. From 09:00 p.m. on 13 February 2004 to 04:00 a.m. of the next day, a high frequency of haematophagic activity and the presence of several bites on the dog's body were observed. This finding represents a serious risk to public health. Thus, it is necessary to further study the bat fauna, with special attention to their feeding behaviour in this place, in order to better know their biology and to adopt pertinent control measures. This is, to our knowledge, the first record of D. rotundus in urban area of Olinda.
Resumo:
Cryptococcus neoformans is an opportunistic fungal pathogen that causes meningoencephalitis as the most frequent clinical presentation in immunocompromised patients, mainly in people infected by HIV. This fungus is an environmental encapsulated yeast, commonly found in soil enriched with avian droppings and plant material. A total of 290 samples of pigeon and the other avian droppings, soil, ornamental trees and vegetable material associated with Eucalyptus trees were collected to study environmental sources of Cryptococcus species in Goiânia, Goiás State. The determination of varieties, serotypes and the susceptibility in vitro to fluconazole, itraconazole and amphotericin B of C. neoformans isolates were performed. C. neoformans var. grubii (serotype A) was found in 20.3% (36/177) of pigeon dropping samples and in 14.3% (5/35) of samples of Eucalyptus. None of the environmental isolates of C. neoformans showed in vitro resistance to three antifungal agents. The knowledge of major route for human cryptococcal infection (inhalation of infectious particles from saprophytic sources) and a total of 60 C. neoformans isolates obtained from AIDS patients with cryptococcal meningitis between October 2001 and April 2002 justify the study of the habitats of these yeasts as probable sources of cryptococcosis in this city.
Resumo:
Smart Cities are designed to be living systems and turn urban dwellers life more comfortable and interactive by keeping them aware of what surrounds them, while leaving a greener footprint. The Future Cities Project [1] aims to create infrastructures for research in smart cities including a vehicular network, the BusNet, and an environmental sensor platform, the Urban Sense. Vehicles within the BusNet are equipped with On Board Units (OBUs) that offer free Wi-Fi to passengers and devices near the street. The Urban Sense platform is composed by a set of Data Collection Units (DCUs) that include a set of sensors measuring environmental parameters such as air pollution, meteorology and noise. The Urban Sense platform is expanding and receptive to add new sensors to the platform. The parnership with companies like TNL were made and the need to monitor garbage street containers emerged as air pollution prevention. If refuse collection companies know prior to the refuse collection which route is the best to collect the maximum amount of garbage with the shortest path, they can reduce costs and pollution levels are lower, leaving behind a greener footprint. This dissertation work arises in the need to monitor the garbage street containers and integrate these sensors into an Urban Sense DCU. Due to the remote locations of the garbage street containers, a network extension to the vehicular network had to be created. This dissertation work also focus on the Multi-hop network designed to extend the vehicular network coverage area to the remote garbage street containers. In locations where garbage street containers have access to the vehicular network, Roadside Units (RSUs) or Access Points (APs), the Multi-hop network serves has a redundant path to send the data collected from DCUs to the Urban Sense cloud database. To plan this highly dynamic network, the Wi-Fi Planner Tool was developed. This tool allowed taking measurements on the field that led to an optimized location of the Multi-hop network nodes with the use of radio propagation models. This tool also allowed rendering a temperature-map style overlay for Google Earth [2] application. For the DCU for garbage street containers the parner company provided the access to a HUB (device that communicates with the sensor inside the garbage containers). The Future Cities use the Raspberry pi as a platform for the DCUs. To collect the data from the HUB a RS485 to RS232 converter was used at the physical level and the Modbus protocol at the application level. To determine the location and status of the vehicles whinin the vehicular network a TCP Server was developed. This application was developed for the OBUs providing the vehicle Global Positioning System (GPS) location as well as information of when the vehicle is stopped, moving, on idle or even its slope. To implement the Multi-hop network on the field some scripts were developed such as pingLED and “shark”. These scripts helped upon node deployment on the field as well as to perform all the tests on the network. Two setups were implemented on the field, an urban setup was implemented for a Multi-hop network coverage survey and a sub-urban setup was implemented to test the Multi-hop network routing protocols, Optimized Link State Routing Protocol (OLSR) and Babel.
Resumo:
The excessive use of pesticides and fertilisers in agriculture has generated a decrease in groundwater and surface water quality in many regions of the EU, constituting a hazard for human health and the environment. Besides, on-site sewage disposal is an important source of groundwater contamination in urban and peri-urban areas. The assessment of groundwater vulnerability to contamination is an important tool to fulfil the demands of EU Directives. The purpose of this study is to assess the groundwater vulnerability to contamination related mainly to agricultural activities in a peri-urban area (Vila do Conde, NW Portugal). The hydrogeological framework is characterised mainly by fissured granitic basement and sedimentary cover. Water samples were collected and analysed for temperature, pH, electrical conductivity, chloride, phosphate, nitrate and nitrite. An evaluation of groundwater vulnerability to contamination was applied (GOD-S, Pesticide DRASTIC-Fm, SINTACS and SI) and the potential nitrate contamination risk was assessed, both on a hydrogeological GIS-based mapping. A principal component analysis was performed to characterised patterns of relationship among groundwater contamination, vulnerability, and the hydrogeological setting assessed. Levels of nitrate above legislation limits were detected in 75 % of the samples analysed. Alluvia units showed the highest nitrate concentrations and also the highest vulnerability and risk. Nitrate contamination is a serious problem affecting groundwater, particularly shallow aquifers, especially due to agriculture activities, livestock and cesspools. GIS-based cartography provided an accurate way to improve knowledge on water circulation models and global functioning of local aquifer systems. Finally, this study highlights the adequacy of an integrated approach, combining hydrogeochemical data, vulnerability assessments and multivariate analysis, to understand groundwater processes in peri-urban areas.