982 resultados para UMBILICAL VEIN


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of radial artery conduits in coronary artery bypass grafting (CABG) surgery is associated with improved long-term patency and patient survival rates as compared with saphenous vein conduits. Despite increasing popularity, relative incidence of local harvest-site complications and subjective perception of adverse long-term sequelae remain poorly described.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Reconstruction of the right ventricular outflow tract plays a major role in congenital cardiac surgery. With the advent of the Contegra bovine jugular vein graft and the Shelhigh pulmonic xenograft, hopes were high that the lack of availability of homografts would be overcome. The present study evaluated both grafts and investigated the influence of known risk factors for premature graft failure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Evaluation of a novel non-invasive tool for postoperative follow-up of patients postelective saphenous vein coronary artery bypass graft (CABG) was performed. Ten patients were included. Their bypass grafts supplied the right coronary artery (7), marginal branches (1), diagonal branches (2), and the circumflex artery (n=1). Each bypass was examined intraoperatively using Doppler flow measurement. Patients were examined with a 3-Tesla magnetic resonance imaging (MRI) scanner (MAGNETOM Verio, Siemens, Erlangen, Germany) within one week postsurgery using MR-angiography with an intravasal contrast agent and velocity encoded phase-contrast flow measurements. Intraoperative Doppler flow measurements revealed regular flow patterns in all vascular territories supplied. The median intraoperative flow rate was 50 ml/min with an inter-quartile range (IQR) of 42-70 ml/min. The clinical postoperative course was uneventful. MRI showed all grafts to be patent. The median postoperative flow rate was 50 ml/min (IQR: 32-65 ml/min). MRI flow rates agreed well with intraoperative Doppler flow measurements (mean difference: -2.8±20.1 ml/min). This initial study demonstrates that 3-Tesla MRI flow measurements correlated well with Doppler thus reconfirming the graft patency postCABG. Further refinement and broader application of this technique may facilitate follow-up postCABG potentially replacing empiric clinical judgment by reliable non-invasive imaging.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Treatment of dialysis access-related hand ischaemia with preservation of the access remains an issue. We report the case of a patient presenting critical hand ischaemia 2 years after proximalisation of a distal radio-cephalic fistula with preservation of the original access. After valvulotomy, the distal cephalic vein was used as in situ bypass and directly anastomosed to the distal brachial artery, providing a direct flow to the hand. This procedure relieved the hand ischaemia without sacrificing the functioning fistula. Six months later, the fistula and bypass were still patent, showing that flow reversal of a previous fistula can be an efficient strategy to correct dialysis access-related hand ischaemia in selected cases.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background—Pulmonary vein stenosis (PVST) is a well-known complication of pulmonary vein isolation (PVI). Specific anatomically designed ablation catheters for antral PVI have not been evaluated with regard to the incidence of PVST. We investigated the incidence, severity, and characteristics of PVST after PVI with the Pulmonary Vein Ablation Catheter (PVAC) and phased radiofrequency technology. Methods and Results A total of 100 patients (55 men) underwent PVI for atrial fibrillation using the PVAC. PVI was guided by selective angiography of each pulmonary vein (PV) in 70 (70%) patients and by reconstructed 3D atriography (ATG) in 30 (30%) patients. Gadolinium-enhanced MRI or multidetector CT was performed in all patients before treatment and 93±78 days after PVI. PVST was classified as follows: insignificant (<25%), mild (25%–50%), moderate (50%–75%), or severe (>75%). A total of 410 PVs were analyzed. Cardiac imaging demonstrated a detectable narrowing of the PV diameter in 23 (23%) patients and in 28 (7%) PVs. In detail, insignificant PVST was observed in 12 (2.9%) PVs, mild PVST in 15 (3.7%), and moderate PVST in 1 (0.2%). No instances of severe PVST were observed. The use of 3D-ATG was associated with a lower incidence of PVST (0.8% [95% CI, 0.0%–2.2%] versus 5.4% [95% CI, 2.7%–8.1%], P=0.027). Conclusions To our knowledge, this study is the first to report the incidence of PVST using the PVAC. In this regard, the PVAC seems to be safe if used in an experienced center. In addition, the use of 3D-ATG may decrease the risk of PVST.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recently we demonstrated higher galectin-3 in portal venous serum (PVS) compared to hepatic venous serum (HVS) in a small cohort of patients with normal liver function suggesting hepatic removal of galectin-3. Here, galectin-3 was measured by ELISA in PVS, HVS and systemic venous blood (SVS) of 33 patients with alcoholic liver cirrhosis and a larger cohort of 11 patients with normal liver function. Galectin-3 was cleared by the healthy but not the cirrhotic liver, and subsequently HVS and SVS galectin-3 levels were significantly increased in the patients with liver cirrhosis compared to controls. In healthy liver galectin-3 was produced by cholangiocytes and synthesis by hepatocytes was only observed in cirrhotic liver. Hepatic venous pressure gradient did not correlate with galectin-3 levels excluding hepatic shunting as the principal cause of higher SVS galectin-3. Galectin-3 was elevated in all blood compartments of patients with CHILD-PUGH stage C compared to patients with CHILD-PUGH stage A, and was higher in patients with ascites than patients without this complication. Galectin-3 was negatively associated with antithrombin-3 whose synthesis is reduced with worse liver function. Galectin-3 positively correlated with urea and creatinine, and PVS galectin-3 showed a negative association with creatinine clearance as an accepted measure of kidney function. To summarize in the current study systemic, portal and hepatic levels of galectin-3 were found to be negatively associated with liver function in patients with alcoholic liver cirrhosis and this may in part be related to impaired hepatic removal and/or increased synthesis in cirrhotic liver.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The cause of orthostatic proteinuria is not clear but may often relate to obstruction of the left renal vein in the fork between the aorta and the superior mesenteric artery (=renal nutcracker). However, reports dealing with proteinuria only marginally refer to this possible cause of orthostatic proteinuria. We analysed the corresponding literature.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Our purpose was to evaluate the antenatal incidence of single umbilical artery (SUA) in twin pregnancies according to chorionicity and to assess its relationship with outcome.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate the isoflurane-sparing effects of lidocaine administered by constant rate infusion (CRI) during umbilical surgery in calves. STUDY DESIGN: Randomized 'blinded' prospective clinical study. ANIMALS: Thirty calves (mean 4.7 +/- SD 2.5 weeks old) undergoing umbilical surgery. METHODS: After premedication with xylazine (0.1 mg kg(-1) , IM), anaesthesia was induced with ketamine (4 mg kg(-1) , IV) and maintained with isoflurane in O(2) administered through a circle breathing system. The calves were assigned randomly to receive a bolus of 2 mg kg(-1) lidocaine IV after induction of anaesthesia, followed by CRI of 50 mug kg(-1) minute(-1) (group L, n=15) or a bolus and CRI of 0.9% sodium chloride (NaCl, group S, n=15). End-tidal isoflurane was adjusted to achieve adequate depth of anaesthesia. Heart rate, direct arterial blood pressure and body temperature were measured intraoperatively. Groups were compared by t- tests, anova or Mann-Whitney rank sum test as appropriate. RESULTS: The end-tidal concentration of isoflurane (median, IQR) was significantly lower in group L [1.0% (0.94-1.1)] compared to group S [1.2% (1.1-1.5)], indicating a 16.7% reduction in anaesthetic requirement during lidocaine CRI. Cardiopulmonary parameters and recovery times did not differ significantly between groups. CONCLUSION AND CLINICAL RELEVANCE: Lidocaine CRI may be used as a supplement to inhalation anaesthesia during umbilical surgery in calves in countries where such a protocol would be within the legal requirements for veterinary use in food animals. This study did not show any measurable benefit to the calves other than a reduction in isoflurane requirement.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report the clinical outcome of a 46-year-old man referred for percutaneous closure of an atrial septal defect under transthoracic echocardiographic and fluoroscopic guidance, whose upper left pulmonary vein was erroneously obliterated using an Amplatzer atrial septal defect occluder. Various medical conditions have been associated with pulmonary vein stenosis including dyspnea on exertion or at rest, cough, and hemoptysis. However, there were no short- or long-term symptoms in this patient.