879 resultados para Skinfold thicknesses


Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work reports on the preparation of erbium and ytterbium co-doped SiO2:HfO2 single mode planar waveguides using the sol-gel method. Silica nanoparticles were prepared from tetraethylorthosilicate in basic media and the films were characterized by transmission electron microscopy, scanning electron microscopy, mechanical profilometry, M-lines spectroscopy based on prism coupling technique, X-ray diffractometry, infrared spectroscopy and photoluminescence spectroscopy. The film thicknesses and the refractive indexes were adjusted in order to satisfy a future efficient coupling to single mode optical fiber. Films suitable for both weak and strong light confinement were prepared varying hafnia concentration into the silica matrix. The lifetime values of erbium I-4(13/2) state were measured in order to investigate the influence of clustering and hydroxyl groups on the fluorescence quantum efficiency of the I-4(13/2) level, responsible for the emission at 1.55 mu m attributed to the I-4(13/2) -> I-4(15/2) transition. The high lifetime values suggest the absence of erbium clusters and the elimination of hydroxyl groups by rapid thermal process. (c) 2007 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Hybrid reflections (HRs) involving substrate and layer planes (SL type) [Morelhao et al., Appl. Phys. Len. 73 (15), 2194 (1998)] observed in Chemical Beam Epitaxy (CBE) grown InGaP/GaAs(001) structures were used as a three-dimensional probe to analyze structural properties of epitaxial layers. A set of (002) rocking curves (omega-scan) measured for each 15 degrees in the azimuthal plane was arranged in a pole diagram in phi for two samples with different layer thicknesses (#A -58 nm and #B - 370 nm) and this allowed us to infer the azimuthal epilayer homogeneity in both samples. Also, it was shown the occurrence of (1 (1) over bar3) HR detected even in the thinner layer sample. Mappings of the HR diffraction condition (omega:phi) allowed to observe the crystal truncation rod through the elongation of HR shape along the substrate secondary reflection streak which can indicate in-plane match of layer/substrate lattice parameters. (C) 2009 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O objetivo deste estudo foi comparar os níveis de adiposidade subcutânea dos hemicorpos direito e esquerdo e, posteriormente, analisar o impacto dessas informações para o estudo da composição corporal. Setenta e seis indivíduos fisicamente ativos, 47 homens (21,6 ± 4,3 anos) e 29 mulheres (21,0 ± 2,6 anos), fizeram parte da amostra. As espessuras das dobras cutâneas abdominal, suprailíaca, subescapular, tricipital, bicipital, axilar média e perna medial foram mensuradas com um compasso Lange. Em valores médios absolutos, as maiores diferenças verificadas foram de 0,9mm (6,9%) e 0,8mm (6,8%), na dobra cutânea suprailíaca de homens e mulheres, respectivamente. Entretanto, nenhuma diferença estatisticamente significante foi encontrada na comparação entre os lados, em ambos os sexos, nas sete dobras cutâneas analisadas (P > 0,05). Similarmente, quando os valores medidos foram aplicados em equações preditivas para a determinação da gordura corporal relativa, de acordo com o sexo, nenhuma diferença significante foi encontrada (P > 0,05). Os resultados sugerem que fatores como o erro técnico de medida do avaliador, o tipo de compasso e a escolha da equação preditiva a ser utilizada, provavelmente tenham maior impacto para a estimativa da composição corporal pelo método de espessura de dobras cutâneas do que o lado a ser adotado como referência para a obtenção das medidas.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We have studied the effects of niobium beam filtration on absorbed doses, on image density and contrast, and on photon spectra with conventional and high-frequency dental x-ray generators. Added niobium reduced entry and superficial absorbed doses in periapical radiography by 9% to 40% with film and digital image receptors, decreased the radiation necessary to produce a given image density on E-speed film and reduced image contrast on D- and E-speed films. As shown by increased half-value layers for aluminum, titanium, and copper and by pulse-height analyses of beam spectra, niobium increased average beam energy by 6% to 19%. Despite the benefits of adding niobium on patient dose reduction and on narrowing the beams' energy spectra, the beam can be overhardened. Adding niobium, therefore, strikes the best balance between radiation dose reduction and beam attenuation, with its risks of increased exposure times, motion blur, and diminished image contrast, when it is used at modest thicknesses (30 μm) and at lower kVp (70) settings. © 1995 Mosby-Year Book, Inc.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Body builders have as their training goals the maximum muscle hypertrophy with minimum adiposity. However, the scarcity of specific standards implies often in framing wrongly those athletes either as overweight (by their BMI) or energy malnourished (by their fat stores). The objective of this study was to compare the body composition of body builders with population standards. Thirty-six adults, 26 male (27.2 ± 7.2 years) and 10 female (30 ± 6.1 years) nationwide competitive body builders, were assessed considering weight, height, body mass index, adiposity, arm and leg circumferences and skinfolds. The data were referred either as percentile or standard deviations (Z score) of population standards. Body weight and height were among the closest values from the populational mean whereas upper arm muscle circumference (for men) and body adiposity (for women) were the farterest. By using fat parameters as indicators of their protein-energy status, the undernourishment was found in 88.5% of men and 100.0% of women. Thus, it seems that body builders deserve their own anthropometric standards to avoid nutritional status misplacements.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: The aim of the present study was to evaluate zygomatic bone thickness considering a possible relationship between this parameter and cephalic index (Cl) for better use of Cl in the implant placement technique. Materials and Methods: Cl was calculated for 60 dry Brazilian skulls. The zygo matic bones of the skulls were divided into 13 standardized sections for measurement. Bilateral measurements of zygomatic bone thickness were made on dry skulls. Results: Sections 5, 6, 8, and 9 were appropriate for implant anchorage in terms of location. The mean thicknesses of these sections were 6.05 mm for section 5, 3.15 mm for section 6, 6.13 mm for section 8, and 4.75 mm for section 9. In only 1 section, section 8, did mean thickness on 1 side of of the skull differ significantly from mean thickness on the other side (P <.001). Discussion: For the relationship between quadrant thick ness and Cl, sections 6 and 8 varied independently of Cl. Section 5 associated with brachycephaly, and section 9 associated with subbrachycephaly, presented variations in the corresponding thickness. Conclusion: Based on the results, implants should be placed in sections 5 and 8, since they presented the greatest thickness, except in brachycephalic subjects, where thickness was greatest in section 5, and in subbrachycephalic subjects, where thickness was greatest in section 9. Cl did not prove to be an appropriate parameter for evaluating zygomatic bone thickness for this sampling.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to examine the agreement between the results of body fat (BF and BF%), fat-free mass (FFM) and FFM index (FFMI= FFM/height2) as estimated by skinfold anthropometry (ANT), bioelectrical impedance (BIA) and dual-energy X-ray absorptiometry (DXA) in two groups of men (> or = 50 y), one comprising healthy individuals (n=23) and the other, patients with chronic obstructive pulmonary disease (COPD) (n=24). Comparisons between body composition techniques were done by repeated measures ANOVA; the Bland & Altman procedure was used to analyse agreement. RESULTS AND CONCLUSIONS: 1) comparison between healthy and COPD groups showed significant differences between all studied variables; 2) in the healthy group, values for BF, BF%, FFM and FFMI were not significantly different when BIA or ANT was compared to DXA; however, in COPD, values for BF and BF% were significantly higher and for FFM and FFMI significantly lower when BIA was compared to DXA; in contrast, no differences were shown between values for these variables when ANT was compared with DXA; 3) Bland & Altman test, in both groups, showed no agreement between BIA and DXA and between ANT and DXA; it was also shown that body fat was overestimated and fat free mass underestimated by BIA in relation to DXA.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: To verify the prevalence of overweight and obesity in 7 to 10 year old schoolchildren of both sexes and high socioeconomic level. Methods: Five hundred and eleven schoolchildren (274 boys and 237 girls) were submitted to anthropometrical measurements of body mass, stature and subscapular and triceps skin-fold thickness. Body mass indexes ≥85th percentile and <95th percentile were used to determine overweight, whereas body mass indexes ≥95th percentile were adopted as indicators of obesity. The socioeconomic level was established based on information obtained from a questionnaire, considering the degree of education of the parents and the familiar consumables. Results: The total prevalence for overweight was 19.7% for the boys and 17.3% for the girls, with no significant differences amongst ages and sexes (p>0.05). On the other hand, the prevalence for obesity in the boys and girls was 17.5% and 9.3%, respectively, with significant differences between the sexes at 9 years (p<0.01) and 10 years (p<0.05) of age, as well as amongst the entire group of ages (p<0.01). Conclusion: The results indicated a high prevalence ratio for overweight (∼19%) and obesity (∼14%), much greater than the average for the 7-10 year old Brazilian population. Therefore, different from that observed in developed countries, a high socioeconomic level seems to negatively affect the prevalence for overweight and obesity, increasing the risk of the precocious development of metabolic dysfunctions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The objective of the present study was to estimate the allele and genotype frequencies of the CSN3/Hinfl and LGB/HaeIII gene polymorphisms in beef cattle belonging to different genetic groups, and to determine the effects of these polymorphisms on growth and carcass traits in these animals, which are submitted to an intensive production model. Genotyping was performed on 79 Nelore, 30 Canchim (5/8 Charolais + 3/8 Zebu) and 275 crossbred cattle originating from the crosses of Simmental (n = 30) and Angus (n = 245) sires with Nelore females. Body weight, weight gain, dressing percentage, longissimus dorsi area and backfat thickness were fitted using the GLM procedure, and least square means of the genotypes were compared by the F test. The results showed that the CSN3/Hinfl and LGB/HaeIII polymorphisms did not have any effect on growth or carcass traits (p > 0.05). Copyright by the Brazilian Society of genetics.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

It is well known that fatigue behaviour is an important parameter to be considered in mechanical components subjected to constant and variable amplitude loadings. In combination with corrosion phenomenon, fatigue effects were responsible for proximally 64% of fails that occur in metallic parts of aeronautical accidents in the last 30 years. Recovered substrates have been extensively used in the aerospace field. Cadmium electroplating has been widely applied to promote protective coatings in aeronautical components, resulting in excellent corrosion protection combined with a good performance in cyclic loading. Ecological considerations allied to the increasing demands for corrosion resistance, resulted in the search for possible alternatives. Zinc-nickel alloys received considerable interest recently, since these coatings showed some advantages such as a good resistance to white and red rust, high plating rates and acceptation in the market. In this study the effects of zinc-nickel coatings electroplated on AISI 4340 high strength steel were analysed on rotating bending and axial fatigue strength, corrosion and adhesion resistance. Compressive residual stress field was measured by a X-ray tensometry prior to fatigue tests. Optical microscopy images showed coating thicknesses, adhesion and the existence of an uniform coverage of nearly all substrates. The fractured fatigue specimens were investigated using a scanning electron microscope. Three different zinc-nickel coating thicknesses were tested and comparison with rotating bending fatigue data from specimens cadmium electroplated and heat treated at 190°C for 3, 8 and 24 hours to avoid the diffusion of hydrogen in the substrate, was performed. Experimental results showed effect of coatings on the AISI 4340 steel behaviour when submitted to fatigue testing and the existence of coating thickness influence on the fatigue strength.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study aimed to evaluate the influence of cement thickness on the bond strength of a fiber-reinforced composite (FRC) post system to the root dentin. Eighteen single-rooted human teeth were decoronated (length: 16 mm), the canals were prepared, and the specimens were randomly allocated to 2 groups (n = 9): group 1 (low cement thickness), in which size 3 FRC posts were cemented using adhesive plus resin cement; and group 2 (high cement thickness), in which size 1 FRC posts were cemented as in group 1. Specimens were sectioned, producing 5 samples (thickness: 1.5 mm). For cement thickness evaluation, photographs of the samples were taken using an optical microscope, and the images were analyzed. Each sample was tested in push-out, and data were statistically analyzed. Bond strengths of groups 1 and 2 did not show significant differences (P = .558), but the cement thicknesses for these groups were significantly different (P < .0001). The increase in cement thickness did not significantly affect the bond strength (r2 = 0.1389, P = .936). Increased cement thickness surrounding the FRC post did not impair the bond strength.