946 resultados para Sewage Effluent
Resumo:
This paper evaluate the performance of a Wastewater Treatment Plant (WWTP) in sequential batch activated sludge modality with tertiary treatment step, located in high temperature region. It also presents the analysis of organic matter’s removal and the evaluation of sludge sedimentation conditions through reactors in bench scale, fed with different substrate’s and biomass’ concentrations, from the WWTP in study. The results showed high efficiency and stability of the treatment process using Sequential Batch Reactors for domestic sewage, even with sudden changes of organic and hydraulic load, reaching more than 90% of efficiency in the removal of biodegradable organic matter. The removal of organic matter and sedimentation tests in bench reactors showed the good performance in respect of the organic matter’s removal, however, the high concentration of micro-organism results in a lower sludge sedimentation rate, which can compromise the quality of the final effluent. The relation Food/Microorganism in the conditions of the WWTP’s current operation showed a value of 0.06 gCOD/gVSS.d. and zonal sedimentation velocity of 0.59 m/h, the great ratio of the concentration of the substrate by biomass concentration, which obtained the maximum operational efficiency, showed a value of 0.09 gCOD/gVSS.d. and zonal sedimentation velocity of 1.4 m/h.
Resumo:
Mémoire numérisé par la Direction des bibliothèques de l'Université de Montréal.
Resumo:
Mémoire numérisé par la Direction des bibliothèques de l'Université de Montréal.
Resumo:
In Canada, increases in rural development has led to a growing need to effectively manage the resulting municipal and city sewage without the addition of significant cost- and energy- expending infrastructure. Storring Septic Service Limited is a family-owned, licensed wastewater treatment facility located in eastern Ontario. It makes use of a passive waste stabilization pond system to treat and dispose of waste and wastewater in an environmentally responsible manner. Storring Septic, like many other similar small-scale wastewater treatment facilities across Canada, has the potential to act as a sustainable eco-engineered facility that municipalities and service providers could utilize to manage and dispose of their wastewater. However, it is of concern that the substantial inclusion of third party material could be detrimental to the stability and robustness of the pond system. In order to augment the capacity of the current facility, and ensure it remains a self-sustaining system with the capacity to safely accept septage from other sewage haulers, it was hypothesized that pond effluent treatment could be further enhanced through the incorporation of one of three different technology solutions, which would allow the reduction of wastewater quality parameters below existing regulatory effluent discharge limits put in place by Ontario’s Ministry of the Environment and Climate Change (MOECC). Two of these solutions make use of biofilm technologies in order to enhance the removal of wastewater parameters of interest, and the third utilizes the natural water filtration capabilities of zebra mussels. Pilot-scale testing investigated the effects of each of these technologies on treatment performance under both cold and warm weather operation. This research aimed to understand the important mechanisms behind biological filtration methods in order to choose and optimize the best treatment strategy for full-scale testing and implementation. In doing so, a recommendation matrix was elaborated provided with the potential to be used as a universal operational strategy for wastewater treatment facilities located in environments of similar climate and ecology.
Resumo:
The amounts of farm dairy effluent stored in ponds and irrigated to land have steadily increased with the steady growth of New Zealand's dairy industry. About 80% of dairy farms now operate with effluent storage ponds allowing deferred irrigation. These storage and irrigation practices cause emissions of greenhouse gases (GHG) and ammonia. The current knowledge of the processes causing these emissions and the amounts emitted is reviewed here. Methane emissions from ponds are the largest contributor to the total GHG emissions from effluent in managed manure systems in New Zealand. Nitrous oxide emissions from anaerobic ponds are negligible, while ammonia emissions vary widely between different studies, probably because they depend strongly on pH and manure composition. The second-largest contribution to GHG emissions from farm dairy effluent comes from nitrous oxide emissions from land application. Ammonia emissions from land application of effluent in New Zealand were found to be less than those reported elsewhere from the application of slurries. Recent studies have suggested that New Zealand's current GHG inventory method to estimate methane emissions from effluent ponds should be revised. The increasing importance of emissions from ponds, while being a challenge for the inventory, also provides an opportunity to achieve mitigation of emissions due to the confined location of where these emissions occur. © 2015 © 2015 The Royal Society of New Zealand.
Resumo:
The release of nitrogen compounds in water bodies can result in many environmental problems, so treat wastewater, such as sewage in order to remove not only organic matter but also nitrogen has been studied a few decades. From the above, the objective of this study was to evaluate the performance of a structured bed reactor, continuous flow, with recirculation, in removing organic matter and nitrogen present in wastewater under different cycles of intermittent aeration (AI) and to evaluate the influence of these cycles in the development of nitrifying bacteria (Oxidizing Bacteria Ammonia - BOA and Bacteria Oxidizing Nitrite - BON) and denitrifying (DESN) adhered (Support Material - MS) and suspension (Effluent - EF and sludge - LD). The reactor used has usable volume of 9.4 L. As support materials (MS) polyurethane foam was used, cut and fixed in PVC rods. 3 were worked aeration phases (AE) and non-aeration (AN) at different stage: Stage 1 (4 h EA / AN 2H); Stage 2 (2H EA / AN 1 h) and Phase 3 (2H EA / AN 2 h). During all hydraulic detention time phases was kept at 16 h and the effluent recirculated at a rate of 3 times the inflow. Were analyzed: pH, total alkalinity, temperature, chemical oxygen demand (COD), Biochemical Oxygen Demand (BOD), nitrogen Kjeldhl Total (NKT), ammonia-N-N-NH4+, nitrito-N-NO2+andnitrato-NO3-. The concentration of BOA, BON and DESN was determined using the number More Provável.gSSV-1 (NMP.gSSV-1). In phase 1 the percentage removal NTK N-NH4+ and NT was 76±10%, 70±21% and 67±10% respectively. In Phase 2 80±15% of removel NKT, 86±15% of N-NH4+ e 68±9% of removel NT e na Fase 3 de 58±20%, 72±28% and 41±6% of NKT, N-NH4+ of NT, respectively. The denitrification efficiency in stage 3 was over 70%, indicating that occurred in the reactor the process of simultaneous nitrification and denitrification (NDS). DQOT the removal percentages were 88 ± 4% in Phase 1, 94 ± 7 in Phase 2 and 90± 11% in Phase 3. The multivariate ANOVA applied to NMP.gSSV-1, it indicated that there was significant (F: 20,2, p <0,01) between the analyzed concentration of organisms AI in different cycles, but the differences between NMP.gSSV-1 depends not only isolated factors but of which means, and phase groups being analysis. From the results it is concluded that the working system is efficient in terms of nitrogen removal and organic matter, and that the stage with the highest availability of Dissolved Oxygen (DO) and C/N ratio (Step 2), was the one obtained the lower concentrations of organic matter effluents and N-NH4+. Hinted that there was a significant difference between the concentration (NMP.100mL-1) of the analyzed organizations (BOA, BON and DESN), but this difference does not depend on factors alone but of which means (MS, EF or LD), stages (1, 2 or 3) and groups (BOA, BON and DESN) is being considered.
Resumo:
This study presents two novel methods for treating important environmental contaminants from two different wastewater streams. One process utilizes the kinetic advantages and reliability of ion exchanging clinoptilolite in combination with biological treatment to remove ammonium from municipal sewage. A second process, HAMBgR (Hybrid Adsorption Membrane Biological Reactor), combines both ion exchange resin and bacteria into a single reactor to treat perchlorate contaminated waters. Combining physicochemical adsorptive treatment with biological treatment can provide synergistic benefits to the overall removal processes. Ion exchange removal solves some of the common operational reliability limitations of biological treatment, like slow response to environmental changes and leaching. Biological activity can in turn help reduce the economic and environmental challenges of ion exchange processes, like regenerant cost and brine disposal. The second section of this study presents continuous flow column experiments, used to demonstrate the ability of clinoptilolite to remove wastewater ammonium, as well as the effectiveness of salt regeneration using highly concentrated sea salt solutions. The working capacity of clinoptilolite more than doubled over the first few loading cycles, while regeneration recovered more than 98% of ammonium. Using the regenerant brine for subsequent halotolerant algae growth allowed for its repeated use, which could lead to cost savings and production of valuable algal biomass. The algae were able to uptake all ammonium in solution, and the brine was able to be used again with no loss in regeneration efficiency. This process has significant advantages over conventional biological nitrification; shorter retention times, wider range of operational conditions, and higher quality effluent free of nitrate. Also, since the clinoptilolite is continually regenerated and the regenerant is rejuvenated by algae, overall input costs are expected to be low. The third section of this study introduces the HAMBgR process for the elimination of perchlorate and presents batch isotherm experiments and pilot reactor tests. Results showed that a variety of ion-exchange resins can be effectively and repeatedly regenerated biologically, and maintain an acceptable working capacity. The presence of an adsorbent in the HAMBgR process improved bioreactor performance during operational fluctuations by providing a physicochemical backup to the biological process. Pilot reactor tests showed that the HAMBgR process reduced effluent perchlorate spikes by up to 97% in comparison to a conventional membrane bio-reactor (MBR) that was subject to sudden changes in influent conditions. Also, the HAMBgR process stimulated biological activity and lead to higher biomass concentrations during increased contaminant loading conditions. Conventional MBR systems can be converted into HAMBgR’s at a low cost, easily justifiable by the realized benefits. The concepts employed in the HAMBgR process can be adapted to treat other target contaminants, not just perchlorate.
Resumo:
Untreated effluents that reach surface water affect the aquatic life and humans. This study aimed to evaluate the wastewater s toxicity (municipal, industrial and shrimp pond effluents) released in the Estuarine Complex of Jundiaí- Potengi, Natal/RN, through chronic quantitative e qualitative toxicity tests using the test organism Mysidopsis Juniae, CRUSTACEA, MYSIDACEA (Silva, 1979). For this, a new methodology for viewing chronic effects on organisms of M. juniae was used (only renewal), based on another existing methodology to another testorganism very similar to M. Juniae, the M. Bahia (daily renewal).Toxicity tests 7 days duration were used for detecting effects on the survival and fecundity in M. juniae. Lethal Concentration 50% (LC50%) was determined by the Trimmed Spearman-Karber; Inhibition Concentration 50% (IC50%) in fecundity was determined by Linear Interpolation. ANOVA (One Way) tests (p = 0.05) were used to determinate the No Observed Effect Concentration (NOEC) and Low Observed Effect Concentration (LOEC). Effluents flows were measured and the toxic load of the effluents was estimated. Multivariate analysis - Principal Component Analysis (PCA) and Correspondence Analysis (CA) - identified the physic-chemical parameters better explain the patterns of toxicity found in survival and fecundity of M. juniae. We verified the feasibility of applying the only renewal system in chronic tests with M. Juniae. Most efluentes proved toxic on the survival and fecundity of M. Juniae, except for some shrimp pond effluents. The most toxic effluent was ETE Lagoa Aerada (LC50, 6.24%; IC50, 4.82%), ETE Quintas (LC50, 5.85%), Giselda Trigueiro Hospital (LC50, 2.05%), CLAN (LC50, 2.14%) and COTEMINAS (LC50, IC50 and 38.51%, 6.94%). The greatest toxic load was originated from ETE inefficient high flow effluents, textile effluents and CLAN. The organic load was related to the toxic effects of wastewater and hospital effluents in survival of M. Juniae, as well as heavy metals, total residual chlorine and phenols. In industrial effluents was found relationship between toxicity and organic load, phenols, oils and greases and benzene. The effects on fertility were related, in turn, with chlorine and heavy metals. Toxicity tests using other organisms of different trophic levels, as well as analysis of sediment toxicity are recommended to confirm the patterns found with M. Juniae. However, the results indicate the necessity for implementation and improvement of sewage treatment systems affluent to the Potengi s estuary
Resumo:
Trinitrotoluene in the purification step (TNT) produced in industries, are carried out two washes at the end of the process. The first wash is done with vaporized water, which originates from the first effluent called yellow water, then the second washing with the use of sodium sulfite is performed (Na2SO3), generating a second effluent red water. This study aimed to study the individual effects, as well as the association of heterogeneous photocatalysis using TiO2 and biological treatment in air lift reactor using activated sludge (bacterial biomass) for the remediation of wastewater contaminated with nitroaromatic compounds in order to reduce toxicity and adjust the legal parameters according to regulatory agencies for disposal in waterways. The photocatalytic treatment was conducted by factorial design obtaining the best reaction conditions (pH 6.5 and concentration of TiO2 0.1 gL-1), with best results obtained at 360 minutes of reaction, reducing the absorbance 97.00%, 94.20% of the chemical oxygen demand (COD), 67.70% of total phenols, as well as a total reduction of observed peaks and assigned to nitroaromatic compounds by high-performance liquid chromatography. In the biological treatment, there was a 53.40% reduction in absorbance at 275 nm 10.00% 36.00% COD and total phenols in a short time (3 days), while for extended periods (48 days) there was an antagonistic influence on the results so that was the elevation of these parameters (COD and total phenols) instead of reducing. Chromatographic analysis confirmed the effectiveness of the biological degradation by reducing the peaks corresponding to compounds DNT and TNT. The Association of photocatalytic and biological treatments decreased results in the order of 91.10% absorbance, 70.26% of total phenols and 88.87% of COD. While the combination of biological and photocatalytic treatments generated relatively lower efficiencies, with 77.30% of absorbance reduction, 62.10% reduction of total phenols and a decrease of 87.00% of COD. In general, when comparing the chemical and biological processes in isolation, the photocatalytic treatment showed the best results. However, comparing the results of isolation and established associations, the association biological x photocatalysis showed more promising results in the treatment of red water effluent.
Resumo:
The levels of some heavy metals in soil samples and tubers of cocoyam ( Colocasia esculentum ) grown on soil receiving paint wastes (PWS) has been investigated using Atomic Absorption spectrophotometer (Unicam 939/959 model). Similar analyses were carried out for the same plant from a control area. The studies revealed that although the P.W.S contained abnormally high levels of Pb (474.14mgkg-1) and Cu (137.85mgkg-1). The paint waste tuber (PWT) recorded low levels of these metals: Pb (2.13mgkg-1) and Cu (13.85mgkg-1) respectively. Correlation analysis tested at 0.05 level of significance show that no significant correlation existed between the metals levels in the soil and the level in the tuber. In all cases the levels of the metals in the tubers were well below the upper limit documented for unpolluted plant. The results however suggest the ineffectiveness of the use of Colocasia esculentum as a bioindicator for heavy metal pollution in soil.
Resumo:
The processing of industry and domestic effluents in wastewater treatment plants reduces the amount of polluted material and forms reusable water and dehydrated sludge. the generation of hazardous municipal sludge can be decreased, as well as the impact on surface and underground water and the risk to human health. The aim this study is to verify the possibility to use sintered sewage sludge as support material after thermal treatment in the production of a filtering material to water supply systems. After thermal treatment the sewage sludge ash was characterized by X-ray fluorescence (XRF), leaching test and water solubilization. Dehydration of sludge was performed by controlled heating at temperatures of 180 degrees C, 350 degrees C, 600 degrees C, 850 degrees C and 1000 degrees C for 3 hours.
Resumo:
The submarine sewage outfall of Santos (SSOS) is situated in the Santos Bay (São Paulo, Brazil) and is potentially a significant source of contaminants to the adjacent marine ecosystem. The present study aimed to assess the influence of SSOS on the sediment toxicity and contamination at Santos Bay. At the disposal site, sediments tended to be finer, organically richer and exhibited higher levels of surfactants and metals, sometimes exceeding the Threshold Effect Level values. The SSOS influence was more evident toward the East, where the sediments exhibited higher levels of TOC, total S and metals during the summer 2000 sampling campaign. Sediment toxicity to amphipods was consistently detected in four of the five stations studied. Amphipod survival tended to correlate negatively to Hg, total N and % mud. This work provides evidence that the SSOS discharge affects the quality of sediments from Santos Bay, and that control procedures are warranted. (c) 2005 Elsevier Ltd. All rights reserved.