962 resultados para SPIRAL GALAXY NGC-2403
Resumo:
Building on our discovery that mutations in the transmembrane serine protease, TMPRSS3, cause nonsyndromic deafness, we have investigated the contribution of other TMPRSS family members to the auditory function. To identify which of the 16 known TMPRSS genes had a strong likelihood of involvement in hearing function, three types of biological evidence were examined: 1) expression in inner ear tissues; 2) location in a genomic interval that contains a yet unidentified gene for deafness; and 3) evaluation of hearing status of any available Tmprss knockout mouse strains. This analysis demonstrated that, besides TMPRSS3, another TMPRSS gene was essential for hearing and, indeed, mice deficient for Hepsin (Hpn) also known as Tmprss1 exhibited profound hearing loss. In addition, TMPRSS2, TMPRSS5, and CORIN, also named TMPRSS10, showed strong likelihood of involvement based on their inner ear expression and mapping position within deafness loci PKSR7, DFNB24, and DFNB25, respectively. These four TMPRSS genes were then screened for mutations in affected members of the DFNB24 and DFNB25 deafness families, and in a cohort of 362 sporadic deaf cases. This large mutation screen revealed numerous novel sequence variations including three potential pathogenic mutations in the TMPRSS5 gene. The mutant forms of TMPRSS5 showed reduced or absent proteolytic activity. Subsequently, TMPRSS genes with evidence of involvement in deafness were further characterized, and their sites of expression were determined. Tmprss1, 3, and 5 proteins were detected in spiral ganglion neurons. Tmprss3 was also present in the organ of Corti. TMPRSS1 and 3 proteins appeared stably anchored to the endoplasmic reticulum membranes, whereas TMPRSS5 was also detected at the plasma membrane. Collectively, these results provide evidence that TMPRSS1 and TMPRSS3 play and TMPRSS5 may play important and specific roles in hearing.
Resumo:
L’experiència de crear, en format televisiu, un programa de difusió històrica per part d’una televisió local resulta altament interessant, perquè ofereix continguts d’àmbit més proper a un públic que difícilment té accés a la seva història des del sector audiovisual. Tots els principis continguts en la proposta científica d’utilitzar les imatges com a transmissores de coneixements i de cultura, convergeixen en el projecte de creació, per part de Televisió de Girona, del programa L’espiral de la història, atès que resulta una excel·lent mostra de la conjunció de diverses tipologies documentals posades al servei d’un objectiu: la difusió de la història de la ciutat de Girona a través del llenguatge audiovisual
Resumo:
Black-blood MR coronary vessel wall imaging may become a powerful tool for the quantitative and noninvasive assessment of atherosclerosis and positive arterial remodeling. Although dual-inversion recovery is currently the gold standard, optimal lumen-to-vessel wall contrast is sometimes difficult to obtain, and the time window available for imaging is limited due to competing requirements between blood signal nulling time and period of minimal myocardial motion. Further, atherosclerosis is a spatially heterogeneous disease, and imaging at multiple anatomic levels of the coronary circulation is mandatory. However, this requirement of enhanced volumetric coverage comes at the expense of scanning time. Phase-sensitive inversion recovery has shown to be very valuable for enhancing tissue-tissue contrast and for making inversion recovery imaging less sensitive to tissue signal nulling time. This work enables multislice black-blood coronary vessel wall imaging in a single breath hold by extending phase-sensitive inversion recovery to phase-sensitive dual-inversion recovery, by combining it with spiral imaging and yet relaxing constraints related to blood signal nulling time and period of minimal myocardial motion.
Resumo:
The growth history of two populations of snowball garnet from the Lukmanier Pass area (central Swiss Alps) was examined through a detailed analysis of three-dimensional geometry, chemical zoning and crystallographic orientation. The first population, collected in the hinge of a chevron-type fold, shows an apparent rotation of 360 degrees. The first 270 degrees are characterized by spiral-shaped inclusion trails, gradual and concentric Mn zoning and a single crystallographic orientation, whereas in the last 90 degrees, crenulated inclusion trails and secondary Mn maxima centred on distinct crystallographic garnet domains are observed. Microstructural, geochemical and textural data indicate a radical change in growth regime between the two growth sequences. In the first 270 degrees, growth occurred under rotational non-coaxial flow, whereas in the last 90 degrees, garnet grew under a non-rotational shortening regime. The second population, collected in the limb of the same chevron-type fold structure, is characterized by a spiral geometry that does not exceed 270 degrees of apparent rotation. These garnet microstructures do not record any evidence for a modification of the stress field during garnet growth. Concentric Mn zoning as well as a single crystallographic orientation are observed for the entire spiral. Electron backscatter diffraction data indicate that nearly all central domains in the snowball garnet are characterized by one [001] axis oriented (sub-)parallel to the symmetry axis and by another [001] axis oriented (sub-)parallel to the orientation of the internal foliation. These features suggest that the crystallographic orientation across the garnet spiral is not random and that a relation exists among the symmetry axis, the internal foliation and the crystallographic orientation.
Resumo:
OBJECTIVE: Ultrasounds are a useful tool when looking for indirect evidence in favor of pulmonary embolism. The aim of this study was to determine the incidence of acute cor pulmonale and deep venous thrombosis revealed by ultrasonographic techniques in a population of patients presenting with pulmonary embolism. METHODS: 96 consecutive patients with a mean (+/- SD) age of 65 +/- 15 years, admitted to our hospital for pulmonary embolism were included in this study. The diagnosis of pulmonary embolism was made either by spiral computed tomography or selective pulmonary angiography. Each patient subsequently underwent both trans-thoracic echocardiography and venous ultrasonography. The diagnostic criterion used for defining acute cor pulmonale by echocardiography was the right to left ventricular end-diastolic area ratio over (or equal to) 0.6. Diagnosis of deep venous thrombosis was supported by the visualization of thrombi or vein incompressibility and/or the absence of venous flow or loss of flow variability by venous ultrasonography. RESULTS: Using ultrasounds, an acute cor pulmonale was found in 63% of our patients while 79% were found to have deep venous thrombosis and 92% of the patients had either acute cor pulmonale or deep venous thrombosis or both. All of the patients with proximal pulmonary embolism had acute cor pulmonale and/or deep venous thrombosis. The presence of acute cor pulmonale on echocardiography was significantly higher in patients with proximal pulmonary embolism (p < 0.0001). CONCLUSION: This study emphasizes the potential value of ultrasonographic techniques in the diagnosis of acute pulmonary embolism.
Resumo:
BACKGROUND: The usual treatment of blunt aortic injury (BAI) is prompt surgery. Frequently severe injuries to the brain or lungs exclude further surgical treatment. The purpose of this study is to assess the feasibility of placing endovascular stent-grafts. METHODS: From 1992 through 1999, in our primary and referral trauma center, 26 acute BAI, 21 males and 5 females, mean age 40.2+/-16.3 yrs were diagnosed. The last 4 patients underwent prospectively endovascular repair with Talent endograft. Endoprosthesis parameters were measured on three-dimensional spiral CT reconstruction. While waiting for devices, blood pressure was aggressively lowered and aortic lesions were monitored by transesophageal echography. RESULTS: Stent-graft deployment was successful in all 4 patients. There were no complications of endoleak, stent migration, paraplegia or death. Angiographic exclusion was complete in all 4 patients. CT scans at a mean follow-up of 11+/-5 months showed complete healing of the aortic wall in all patients. CONCLUSIONS: For stable acute BAI, endovascular stent-graft repair is feasible and safe, and is an effective therapeutic alternative to open surgery. Because of the normal proximal and distal wall in aortic injuries, endoluminal treatment might be the therapy of choice in the near future.
Resumo:
PURPOSE: To analyze outcomes after right portal vein embolization extended to segment IV (right PVE + IV) before extended right hepatectomy, including liver hypertrophy, resection rates, and complications after embolization and resection, and to assess differences in outcomes with two different particulate embolic agents. MATERIALS AND METHODS: Between 1998 and 2004, transhepatic ipsilateral right PVE + IV with particles and coils was performed in 44 patients with malignant hepatobiliary disease, including metastases (n = 24), biliary cancer (n = 14), and hepatocellular carcinoma (n = 6). Right PVE + IV was considered if the future liver remnant (FLR; segments II/III with or without I) was less than 25% of the total estimated liver volume (TELV). Tris-acryl microspheres (100-700 microm; n = 21) or polyvinyl alcohol (PVA) particles (355-1,000 microm; n = 23) were administered in a stepwise fashion. Smaller particles were used to occlude distal branches, followed by larger particles to occlude proximal branches until near-complete stasis. Coils were then placed in secondary portal branches. Computed tomographic volumetry was performed before and 3-4 weeks after right PVE + IV to assess FLR hypertrophy. Liver volumes and postembolization and postoperative outcomes were measured. RESULTS: After right PVE + IV with PVA particles, FLR volume increased 45.5% +/- 40.9% and FLR/TELV ratio increased 6.9% +/- 5.6%. After right PVE + IV with tris-acryl microspheres, FLR volume increased 69.0% +/- 30.7% and FLR/TELV ratio increased 9.7% +/- 3.3%. Differences in FLR volume (P = .0011), FLR/TELV ratio (P = .027), and resection rates (P = .02) were statistically significant. Seventy-one percent of patients underwent extended right hepatectomy (86% after receiving tris-acryl microspheres, 57% after receiving PVA). Thirteen patients (29%) did not undergo resection (extrahepatic spread [n = 9], inadequate hypertrophy [n = 3], other reasons [n = 1]). No patient developed postembolization syndrome or progressive liver insufficiency after embolization or resection. One death after resection occurred as a result of sepsis and hemorrhage. Median hospital stays were 1 day after right PVE + IV and 7 days after resection. CONCLUSION: Transhepatic ipsilateral right PVE + IV with use of particles and coils is a safe, effective method for inducing contralateral hypertrophy before extended right hepatectomy. Embolization with small spherical particles provides improved hypertrophy and resection rates compared with larger, nonspherical particles.
Resumo:
AIMS: We sought to evaluate the utility of contrast-enhanced coronary magnetic resonance imaging (CE-MRI) for selective visualization and non-invasive differentiation of atherosclerotic coronary plaque in humans. METHODS AND RESULTS: Nine patients with coronary artery disease (CAD) as confirmed by X-ray angiography and multidetector computed tomography (MDCT) were studied by T1-weighted black blood inversion recovery coronary MRI before (N-IR) and after administration of Gd-DTPA (CE-IR). Plaques were categorized as calcified, non-calcified, and mixed based on their Hounsfield number derived from MDCT. With MDCT, a total of 29 plaques were identified, including calcified (n=6), non-calcified (n=6), and mixed calcified/non-calcified (n=17). On N-IR MRI, 26 plaques (90%) were dark, whereas three plaques (two non-calcified and one mixed) appeared bright. On CE-MRI, 13/29 (45%) plaques, 11 of which were mixed, one non-calcified, and one calcified showed contrast uptake. All others remained dark. CONCLUSION: In this preliminary study, we demonstrate the potential utility of CE-IR MRI for selective plaque visualization and differentiation of plaque types. The observed contrast uptake may be associated with endothelial dysfunction, neovascularization, inflammation, and/or fibrosis.
Resumo:
A precise knowledge of arterial, portal, hepatic and biliary anatomical variations is mandatory when a liver intervention is planned. However, only certain variations must be searched when a precise intervention is planned. The basic liver anatomy as well as the most relevant malformations will be precised.
Resumo:
We present the case of a young man with compression of both renal arteries by the crura of the diaphragm. Correct diagnosis of renal artery entrapment is difficult but crucial. The investigations rely on an high index of suspicion and include Doppler ultrasound and spiral computed tomography angiography, which permits visualization of the diaphragm and its relationships with the aorta. This pathology, unlike common renal artery stenoses, requires surgical decompression and sometimes aortorenal bypass graft.
Resumo:
Due to their relatively small size and central location within the thorax, improvement in signal-to-noise (SNR) is of paramount importance for in vivo coronary vessel wall imaging. Thus, with higher field strengths, coronary vessel wall imaging is likely to benefit from the expected "near linear" proportional gain in SNR. In this study, we demonstrate the feasibility of in vivo human high field (3 T) coronary vessel wall imaging using a free-breathing black blood fast gradient echo technique with respiratory navigator gating and real-time motion correction. With the broader availability of more SNR efficient fast spin echo and spiral techniques, further improvements can be expected.
Resumo:
The use of self-calibrating techniques in parallel magnetic resonance imaging eliminates the need for coil sensitivity calibration scans and avoids potential mismatches between calibration scans and subsequent accelerated acquisitions (e.g., as a result of patient motion). Most examples of self-calibrating Cartesian parallel imaging techniques have required the use of modified k-space trajectories that are densely sampled at the center and more sparsely sampled in the periphery. However, spiral and radial trajectories offer inherent self-calibrating characteristics because of their densely sampled center. At no additional cost in acquisition time and with no modification in scanning protocols, in vivo coil sensitivity maps may be extracted from the densely sampled central region of k-space. This work demonstrates the feasibility of self-calibrated spiral and radial parallel imaging using a previously described iterative non-Cartesian sensitivity encoding algorithm.