911 resultados para Receiving Mutual Impedance


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Sustainable natural resource use requires that multiple actors reassess their situation in a systemic perspective. This can be conceptualised as a social learning process between actors from rural communities and the experts from outside organisations. A specifically designed workshop oriented towards a systemic view of natural resource use and the enhancement of mutual learning between local and external actors, provided the background for evaluating the potentials and constraints of intensified social learning processes. Case studies in rural communities in India, Bolivia, Peru and Mali showed that changes in the narratives of the participants of the workshop followed a similar temporal sequence relatively independently from their specific contexts. Social learning processes were found to be more likely to be successful if they 1) opened new space for communicative action, allowing for an intersubjective re-definition of the present situation, 2) contributed to rebalance the relationships between social capital and social, emotional and cognitive competencies within and between local and external actors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: The beneficial effects of beta-blockers and aldosterone receptor antagonists are now well established in patients with severe systolic chronic heart failure (CHF). However, it is unclear whether beta-blockers are able to provide additional benefit in patients already receiving aldosterone antagonists. We therefore examined this question in the COPERNICUS study of 2289 patients with severe CHF receiving the beta1-beta2/alpha1 blocker carvedilol compared with placebo. METHODS: Patients were divided post hoc into subgroups according to whether they were receiving spironolactone (n = 445) or not (n = 1844) at baseline. Consistency of the effect of carvedilol versus placebo was examined for these subgroups with respect to the predefined end points of all-cause mortality, death or CHF-related hospitalizations, death or cardiovascular hospitalizations, and death or all-cause hospitalizations. RESULTS: The beneficial effect of carvedilol was similar among patients who were or were not receiving spironolactone for each of the 4 efficacy measures. For all-cause mortality, the Cox model hazard ratio for carvedilol compared with placebo was 0.65 (95% CI 0.36-1.15) in patients receiving spironolactone and 0.65 (0.51-0.83) in patients not receiving spironolactone. Hazard ratios for death or all-cause hospitalization were 0.76 (0.55-1.05) versus 0.76 (0.66-0.88); for death or cardiovascular hospitalization, 0.61 (0.42-0.89) versus 0.75 (0.64-0.88); and for death or CHF hospitalization, 0.63 (0.43-0.94) versus 0.70 (0.59-0.84), in patients receiving and not receiving spironolactone, respectively. The safety and tolerability of treatment with carvedilol were also similar, regardless of background spironolactone. CONCLUSION: Carvedilol remained clinically efficacious in the COPERNICUS study of patients with severe CHF when added to background spironolactone in patients who were practically all receiving angiotensin-converting enzyme inhibitor (or angiotensin II antagonist) therapy. Therefore, the use of spironolactone in patients with severe CHF does not obviate the necessity of additional treatment that interferes with the adverse effects of sympathetic activation, specifically beta-blockade.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Similarity measure is one of the main factors that affect the accuracy of intensity-based 2D/3D registration of X-ray fluoroscopy to CT images. Information theory has been used to derive similarity measure for image registration leading to the introduction of mutual information, an accurate similarity measure for multi-modal and mono-modal image registration tasks. However, it is known that the standard mutual information measure only takes intensity values into account without considering spatial information and its robustness is questionable. Previous attempt to incorporate spatial information into mutual information either requires computing the entropy of higher dimensional probability distributions, or is not robust to outliers. In this paper, we show how to incorporate spatial information into mutual information without suffering from these problems. Using a variational approximation derived from the Kullback-Leibler bound, spatial information can be effectively incorporated into mutual information via energy minimization. The resulting similarity measure has a least-squares form and can be effectively minimized by a multi-resolution Levenberg-Marquardt optimizer. Experimental results are presented on datasets of two applications: (a) intra-operative patient pose estimation from a few (e.g. 2) calibrated fluoroscopic images, and (b) post-operative cup alignment estimation from single X-ray radiograph with gonadal shielding.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: The CD4 T cell count recovery in human immunodeficiency virus type 1 (HIV-1)-infected individuals receiving potent antiretroviral therapy (ART) shows high variability. We studied the determinants and the clinical relevance of incomplete CD4 T cell restoration. METHODS: Longitudinal CD4 T cell count was analyzed in 293 participants of the Swiss HIV Cohort Study who had had a plasma HIV-1 RNA load <1000 copies/mL for > or =5 years. CD4 T cell recovery was stratified by CD4 T cell count 5 years after initiation of ART (> or =500 cells/microL was defined as a complete response, and <500 cells/microL was defined as an incomplete response). Determinants of incomplete responses and clinical events were evaluated using logistic regression and survival analyses. RESULTS: The median CD4 T cell count increased from 180 cells/microL at baseline to 576 cells/microL 5 years after ART initiation. A total of 35.8% of patients were incomplete responders, of whom 47.6% reached a CD4 T cell plateau <500 cells/microL. Centers for Disease Control and Prevention HIV-1 disease category B and/or C events occurred in 21% of incomplete responders and in 14.4% of complete responders (P>.05). Older age (adjusted odds ratio [aOR], 1.71 per 10-year increase; 95% confidence interval [CI], 1.21-2.43), lower baseline CD4 T cell count (aOR, 0.37 per 100-cell increase; 95% CI, 0.28-0.49), and longer duration of HIV infection (aOR, 2.39 per 10-year increase; 95% CI, 1.19-4.81) were significantly associated with a CD4 T cell count <500 cells/microL at 5 years. The median increases in CD4 T cell count after 3-6 months of ART were smaller in incomplete responders (P<.001) and predicted, in conjunction with baseline CD4 T cell count and age, incomplete response with 80% sensitivity and 72% specificity. CONCLUSION: Individuals with incomplete CD4 T cell recovery to <500 cells/microL had more advanced HIV-1 infection at baseline. CD4 T cell changes during the first 3-6 months of ART already reflect the capacity of the immune system to replenish depleted CD4 T lymphocytes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Steam pops are a risk of irrigated radiofrequency catheter ablation (RFA) and may cause cardiac perforation. Data to guide radiofrequency (RF) energy titration to avoid steam pops are limited. OBJECTIVE: This study sought to assess the frequency and consequence of audible pops and to determine the feasibility of using the magnitude of impedance change to predict pops. METHODS: We reviewed consecutive endocardial open-irrigated RFA for ventricular tachycardia (VT) with continuously recorded ablation data in 142 patients with structural heart disease. Steam pops were defined as an audible pop associated with a sudden spike in impedance. Ablation lesions before or after pops served as controls. RESULTS: From a total of 4,107 ablation lesions, 62 (1.5%) steam pops occurred in 42 procedures in 38 patients. Perforation with tamponade occurred with 1 of 62 (2%) pops. Applications with pops had a greater impedance decrease (22 +/- 7 Omega vs. 18 +/- 8 Omega, P = .001) and a higher maximum power (45 +/- 5 W vs. 43 +/- 6 W, P = .011), but did not differ in maximum catheter tip temperature (40 degrees C +/- 4 degrees C vs. 40 degrees C +/- 4 degrees C, P = .180) from applications without pops. Eighty percent of pops occurred after impedance decreased by at least 18 Omega. CONCLUSION: During VT ablation with open irrigation, audible pops are infrequent and do not usually cause perforation. Limiting RF power to achieve an impedance decrease of <18 Omega is a feasible method of reducing the likelihood of a pop when perforation risk is of concern.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Quality of life (QL) is an important consideration when comparing adjuvant therapies for early breast cancer, especially if they differ substantially in toxicity. We evaluated QL and Q-TWiST among patients randomised to adjuvant dose-intensive epirubicin and cyclophosphamide administered with filgrastim and progenitor cell support (DI-EC) or standard-dose anthracycline-based chemotherapy (SD-CT). We estimated the duration of chemotherapy toxicity (TOX), time without disease symptoms and toxicity (TWiST), and time following relapse (REL). Patients scored QL indicators. Mean durations for the three transition times were weighted with patient reported utilities to obtain mean Q-TWiST. Patients receiving DI-EC reported worse QL during TOX, especially treatment burden (month 3: P<0.01), but a faster recovery 3 months following chemotherapy than patients receiving SD-CT, for example, less coping effort (P<0.01). Average Q-TWiST was 1.8 months longer for patients receiving DI-EC (95% CI, -2.5 to 6.1). Q-TWiST favoured DI-EC for most values of utilities attached to TOX and REL. Despite greater initial toxicity, quality-adjusted survival was similar or better with dose-intensive treatment as compared to standard treatment. Thus, QL considerations should not be prohibitive if future intensive therapies show superior efficacy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To evaluate the effects of palliative chemotherapy with gemcitabine plus capecitabine (GemCap) on patient-reported outcomes measured using clinical benefit response (CBR) and quality-of-life (QOL) measures in patients with advanced biliary tract cancer. PATIENTS AND METHODS: Patients had to manifest symptoms of advanced biliary tract cancer and have at least one of the following: impaired Karnofsky performance score (60 to 80), average analgesic consumption >or= 10 mg of morphine equivalents per day, and average pain intensity score of >or= 20 mm out of 100 mm. Treatment consisted of oral capecitabine 650 mg/m(2) twice daily on days 1 through 14 plus gemcitabine 1,000 mg/m(2) as a 30-minute infusion on days 1 and 8 every 3 weeks until progression. The primary end point was the number of patients categorized as having a CBR or stable CBR (SCBR) during the first three treatment cycles. RESULTS: Forty-four patients were enrolled (bile duct cancer, n = 36; gallbladder cancers, n = 8). The main grade 3 or 4 adverse events included hematologic toxicity and fatigue. After three cycles, 36% of patients achieved a CBR, and 34% achieved an SCBR. Over the full course of treatment, 57% of patients achieved a CBR, and 18% achieved an SCBR. Improved QOL was observed in patients with a CBR or SCBR. The objective response rate was 25%. Median time to progression and overall survival times were 7.2 months and 13.2 months, respectively. CONCLUSION: Chemotherapy with GemCap is well tolerated and effective and leads to a high CBR rate. Patient-reported outcomes are useful for evaluating the effects of palliative chemotherapy in patients with biliary tract cancer.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The noseclip is conventionally used in lung function testing to prevent leakage via the nasal compartments. However, some subjects exhibit a velum-opening reflex which may affect results. We performed forced oscillation measurements at frequencies (8-256 Hz) that include the first antiresonance, comparing the noseclip with a cotton wool nose plug to eliminate upper airway contribution. Three sets of measurements were made in 18 adults: with and without noseclip, and with cotton wool. Velum opening during noseclip measurements was monitored using a nasal pressure transducer. A significantly greater proportion of subjects produced a characteristic distortion to the first antiresonance with the noseclip than with either no noseclip or with cotton wool. Distortion of the spectrum coincided with the transmission of oscillations into the nasal cavity. Thus, the noseclip cannot be used in high-frequency forced oscillation measurements because of the velum reflex. The cotton wool plug offers a simple alternative. This effect has unknown impact in other lung function tests.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: Many flow-cytometric cell characterization methods require costly markers and colour reagents. We present here a novel device for cell discrimination based on impedance measurement of electrical cell properties in a microfluidic chip, without the need of extensive sample preparation steps and the requirement of labelling dyes. MATERIALS AND METHODS, RESULTS: We demonstrate that in-flow single cell measurements in our microchip allow for discrimination of various cell line types, such as undifferentiated mouse fibroblasts 3T3-L1 and adipocytes on the one hand, or human monocytes and in vitro differentiated dendritic cells and macrophages on the other hand. In addition, viability and apoptosis analyses were carried out successfully for Jurkat cell models. Studies on several species, including bacteria or fungi, demonstrate not only the capability to enumerate these cells, but also show that even other microbiological life cycle phases can be visualized. CONCLUSIONS: These results underline the potential of impedance spectroscopy flow cytometry as a valuable complement to other known cytometers and cell detection systems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Traditional methods of measuring sound absorption coefficient and sound transmission loss of a material are time consuming. To overcome this limitation, normal incidence sound absorption and transmission loss measurement technique was developed. Unfortunately the equipment required for this task is equally expensive. Hence efforts are taken to develop a cost-effective equipment for measuring normal incidence sound absorption coefficient and transmission loss. An impedance tube capable of measure absorption coefficient and transmission loss is designed and built under a budget of $1500 for educational institutes. A background study is performed to gain knowledge and understanding of the normal incidence measurements technique. Based on the literature review, parameters involved such as tube material, source and microphone properties, sample holders, etc. are discussed in depth. Based on these parameters, design options are generated to meet the cost and functionality targets pre-assigned. After selection of materials and components, an impedance tube is built and tested using three fibrous absorption materials for absorption and a barrier for transmission loss performance. These measured results then compared with those obtained with the help of industry recognized Brüel & Kjær impedance tube. The results show performances are comparable, hence validation the new built tube.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

During locomotion, turning is a common and recurring event which is largely neglected in the current state-of-the-art ankle-foot prostheses, forcing amputees to use different steering mechanisms for turning, compared to non-amputees. A better understanding of the complexities surrounding lower limb prostheses will lead to increased health and well-being of amputees. The aim of this research is to develop a steerable ankle-foot prosthesis that mimics the human ankle mechanical properties. Experiments were developed to estimate the mechanical impedance of the ankle and the ankles angles during straight walk and step turn. Next, this information was used in the design of a prototype, powered steerable ankle-foot prosthesis with two controllable degrees of freedom. One of the possible approaches in design of the prosthetic robots is to use the human joints’ parameters, especially their impedance. A series of experiments were conducted to estimate the stochastic mechanical impedance of the human ankle when muscles were fully relaxed and co-contracting antagonistically. A rehabilitation robot for the ankle, Anklebot, was employed to provide torque perturbations to the ankle. The experiments were performed in two different configurations, one with relaxed muscles, and one with 10% of maximum voluntary contraction (MVC). Surface electromyography (sEMG) was used to monitor muscle activation levels and these sEMG signals were displayed to subjects who attempted to maintain them constant. Time histories of ankle torques and angles in the lateral/medial (LM) directions, inversion-eversion (IE), and dorsiflexionplantarflexion (DP) were recorded. Linear time-invariant transfer functions between the measured torques and angles were estimated providing an estimate of ankle mechanical impedance. High coherence was observed over a frequency range up to 30 Hz. The main effect of muscle activation was to increase the magnitude of ankle mechanical impedance in all degrees of freedom of the ankle. Another experiment compared the three-dimensional angles of the ankle during step turn and straight walking. These angles were measured to be used for developing the control strategy of the ankle-foot prosthesis. An infrared camera system was used to track the trajectories and angles of the foot and leg. The combined phases of heel strike and loading response, mid stance, and terminal stance and pre-swing were determined and used to measure the average angles at each combined phase. The Range of motion (ROM) in IE increased during turning while ML rotation decreased and DP changed the least. During the turning step, ankle displacement in DP started with similar angles to straight walk and progressively showed less plantarflexion. In IE, the ankle showed increased inversion leaning the body toward the inside of the turn. ML rotation initiated with an increased medial rotation during the step turn relative to the straight walk transitioning to increased lateral rotation at the toe off. A prototype ankle-foot prosthesis capable of controlling both DP and IE using a cable driven mechanism was developed and assessed as part of a feasibility study. The design is capable of reproducing the angles required for straight walk and step turn; generates 712N of lifting force in plantarflexion, and shows passive stiffness comparable to a nonload bearing ankle impedance. To evaluate the performance of the ankle-foot prosthesis, a circular treadmill was developed to mimic human gait during steering. Preliminary results show that the device can appropriately simulate human gait with loading and unloading the ankle joint during the gait in circular paths.